DATE: AAppril 17, 1973
On April 6, 1973, the BPA's "Bationai:Emissions Standards tor Hazardous Air Pollutants" became effective with the publication of these regulations in the Federal Begister. These regulations affect the continued use of MX3-
Effective 90 days fro* date of publication - July 1, 1973 sprayed aateriala used to insulate or fireproof buildings, structures, pipes, and conduits will be limited to those materials which contain less than one percent asbestos on a dry-weight basis. Therefore, MK3 spray operations now in process or about to begin will be permitted, subject to a changeover to conforming materials by July U, 1973-
Fj4.
TPF/rv
Thomas P. Feit - Manager Fire Protection Products
15171040
W R. ORACE A CO.
ZONOLITE
CONSTRUCTION PRODUCTS DIVISION
CONSTRUCTION PRODUCTS DIVISION
03635459
.TO: - 1
T. P. Pelt
November 5, 1973 .
. FROM:.j. ;'Bourke./;:^u:y ;y-;J^yv-t:CC:
/' -go
:V,V
SUBJECT: ; Fitzgerald Letter o$Q/V73
,;
/ -- on Sprayed Fireproofing
M V
FOEgan
'
R. 0. deBastian W. J. Sir.acore
fa I had a meeting with Joe Fitzgerald on 10/18/73 at his " office In City Eall In regard to;?this letter.
We vent over our. new physical properties, report which :v you sent out to us as Bulletin i#31- I left copies
with him for future reference./ The city Is net outlawing Kono-Kote for use In plenums. They; are only concerned .with using sprayed fireproofIng.where It can be knocked off by workman at some-future time. He is thinking of .the elevator repair man walking on sene beans
in a shaft while repairing the elevator. He is also
concerned with fireproofing left exposed in stairwells where ordinary use of these stairs leads people to try to rub off or knock off the Mono-Kote for kicks.
V.'ha: night have brought this on is when the employee cf the John Hancock Center- tried to burn down, tre building. Jce went to inspect the damage and found In the mechanical rooms that the fireproofing had either fallen off cr ceer. .'nocked off the steel tv the employees and not the fire. hie mentioned thin t: resite: it happened abc^t a y-: an ago.
r-.o r.c objections if we seal the "or.o-Kc:-.-
r.ent i tned that a new fire prevent ior. code is coring cut shortly tc be put into ordinance form ty the City Council. I will try to get you a copy if possible in advance to see how it may relate to is In the sprayed fir-o proofing
-s Ar. J. Bourke
WJ3:dd
1 51 7104 i
M'iyy i
r -i s-rt&wttmi
October 4, 1973
Q363S460
Memorandum:
To: Mr. George Wienold , Chief Plan Examiner
Architectural Plan Examiners
Fire Prevention Plan Examiners
Patrick Noonan Chief Code Enforcement Officer
Austin Sullivan Chief Iron Inspector
From:
Joseph Fitzgerald Commissioner of Buildings
Re: Sprayed Fire Proofing
Section 81-14 of the Municipal Ordinance requires that all
ducts be made of sheet metal or other approved materials.
Various materials have been approved as a substitute material such as concrete, concrete block, etc.
Sprayed fire proofed steel however is not one of those materiallss7
approved and is not to be used as an exposed- surface in a duct
Please see to it ,that the mechanical and architectural plans , correspond one to the other in this regard and that no sprayed fire proofing be allowed in the ducting systems.
Because of the erosion that can be expected over the many years
of a building's expected life span sprayed fire proofing is not to
be allowed in any areas where it may be subject to erosion factors;
examples would be in stairwells, elevator shafts, mechanical
shafts and in mechanical or equipment rooms at locations frequented {
by maintenance personnel.
JF:sg