Document 3QNjER5bLexkoR5Q0eXNOreY3

Bnvironnental Protection Agency V); .-i!/ Vy ;^v- ? -.. DATE: AAppril 17, 1973 On April 6, 1973, the BPA's "Bationai:Emissions Standards tor Hazardous Air Pollutants" became effective with the publication of these regulations in the Federal Begister. These regulations affect the continued use of MX3- Effective 90 days fro* date of publication - July 1, 1973 sprayed aateriala used to insulate or fireproof buildings, structures, pipes, and conduits will be limited to those materials which contain less than one percent asbestos on a dry-weight basis. Therefore, MK3 spray operations now in process or about to begin will be permitted, subject to a changeover to conforming materials by July U, 1973- Fj4. TPF/rv Thomas P. Feit - Manager Fire Protection Products 15171040 W R. ORACE A CO. ZONOLITE CONSTRUCTION PRODUCTS DIVISION CONSTRUCTION PRODUCTS DIVISION 03635459 .TO: - 1 T. P. Pelt November 5, 1973 . . FROM:.j. ;'Bourke./;:^u:y ;y-;J^yv-t:CC: /' -go :V,V SUBJECT: ; Fitzgerald Letter o$Q/V73 ,; / -- on Sprayed Fireproofing M V FOEgan ' R. 0. deBastian W. J. Sir.acore fa I had a meeting with Joe Fitzgerald on 10/18/73 at his " office In City Eall In regard to;?this letter. We vent over our. new physical properties, report which :v you sent out to us as Bulletin i#31- I left copies with him for future reference./ The city Is net outlawing Kono-Kote for use In plenums. They; are only concerned .with using sprayed fireproofIng.where It can be knocked off by workman at some-future time. He is thinking of .the elevator repair man walking on sene beans in a shaft while repairing the elevator. He is also concerned with fireproofing left exposed in stairwells where ordinary use of these stairs leads people to try to rub off or knock off the Mono-Kote for kicks. V.'ha: night have brought this on is when the employee cf the John Hancock Center- tried to burn down, tre building. Jce went to inspect the damage and found In the mechanical rooms that the fireproofing had either fallen off cr ceer. .'nocked off the steel tv the employees and not the fire. hie mentioned thin t: resite: it happened abc^t a y-: an ago. r-.o r.c objections if we seal the "or.o-Kc:-.- r.ent i tned that a new fire prevent ior. code is coring cut shortly tc be put into ordinance form ty the City Council. I will try to get you a copy if possible in advance to see how it may relate to is In the sprayed fir-o proofing -s Ar. J. Bourke WJ3:dd 1 51 7104 i M'iyy i r -i s-rt&wttmi October 4, 1973 Q363S460 Memorandum: To: Mr. George Wienold , Chief Plan Examiner Architectural Plan Examiners Fire Prevention Plan Examiners Patrick Noonan Chief Code Enforcement Officer Austin Sullivan Chief Iron Inspector From: Joseph Fitzgerald Commissioner of Buildings Re: Sprayed Fire Proofing Section 81-14 of the Municipal Ordinance requires that all ducts be made of sheet metal or other approved materials. Various materials have been approved as a substitute material such as concrete, concrete block, etc. Sprayed fire proofed steel however is not one of those materiallss7 approved and is not to be used as an exposed- surface in a duct Please see to it ,that the mechanical and architectural plans , correspond one to the other in this regard and that no sprayed fire proofing be allowed in the ducting systems. Because of the erosion that can be expected over the many years of a building's expected life span sprayed fire proofing is not to be allowed in any areas where it may be subject to erosion factors; examples would be in stairwells, elevator shafts, mechanical shafts and in mechanical or equipment rooms at locations frequented { by maintenance personnel. JF:sg 15171042