Document 3QGEqRXzzgv7kZ9R4pYjvnq7x

co: C, L, Bradford P. L. Slayton - 1650 October 12, 1971 Mlaa Eleanor Olbson Varlan Vacuum Division NBC Operation 160 Charlemont Newton, Massachusetts 02161 Dear Miss 01bson: mis letter confirms your telecon of October 11 with Mr. Moore concerning your use of santovac 2 vacuum pump fluid. As Indicated on their labels, Santovac 1 and Santovac 2 contain polychlorinated biphenyls (PCBc) of various types. Aa you are aware, PCBs have Increasingly cone under the scrutiny of various governmental agencies and aclentlflc laboratories. In some studies, certain PCBs have been found to be persistent, an environmental contaminant and possibly injurious to certain forms of bird, aquatic and animal life. Accordingly, It Is Important that PCBs be kept out of the food chain. We want to remind your firm of the extreme care that must be taken by users of Santovac 1 and Santovac 2 fluids to prevent any entry Into the environment through spills, leakage, use, disposal, vaporization or otherwise. Some specific applications where these fluids should definitely not be used are In vacuum systems Involving food or food-related products, animal feeds, pharmaceutical products, packaging materials involving any of such items and buildings where any of these items are manu factured or atored. If your vacuum ayatem Involves any of the mentioned applications, or If your system Is such that entry Into the environment can not bo prevented, you should replace Santovac 1 and 2 with nonPCD nulds Immediately. Please contact your pump supplier for his recommended replacement product. Used Santovac 1 and 2 should be returned to Monsanto Company, W. 0. Krummrlch Plant, Sauget, Illinois 62201, Attention: Supervisor Dept. 246 for proper disposal. This service la per formed at cost, which Is $0.03 per pound. Very truly yours. MONS 092180 /oen R. E. Hatton Technical Manager Hydraulics and Lubricants