Fig 33-3 -- Isolation-type ground fault interrupter An isolating transformer provides an inductive coupling between load and line, both hot and neutral wires connect to the isolating transformer There is no con tinuous wire between
should be placed m a special room or be made inaccessible to other than authorized
personnel by screen enclosures Doors to the enclosure should be kept locked
Good illumination should be provided for the front and rear of switchboards and main tained ready for use at all times An emer gency source of illumination should also be provided
Switch and fuse cabinets should have closefitting doors, and the doors should be kept locked To warn employees that electrical parts are exposed and to remind them to close all doors of equipment, the inside of the doors may be painted orange
The switchboard framework and metal parts of guards should be grounded in accord ance with code regulations
Connections, wiring, and equipment of switchboards and panel boards should be ar ranged in an orderly manner Switches, fuses, and automatic circuit breakers should be plainly marked and arranged to afford ready identification of circuits or equipment supplied through them
It is good practice to keep a diagram of switchboard connections and devices posted near the equipment
Protection against accidental shock from live electrical parts, such as switchboards, fuse panels, and control equipment, can be minimized by insulating the floor area within range of the live parts For low-voltage ex
posures, special insulating mats or dry wood floors with no metal parts are used These insulating mats should be made of material having proper moisture resistance and nonconductive properties, and should withstand mechanical abuses which may be encountered in such service See American Standard J6 senes, "Specifications for Rubber Protective Equipment for Electncal Workers "
Circuits initiated by pushbuttons should be low voltage However, pushbutton controls may be used for a high-voltage circuit if stepdown transformers are provided to prevent the voltage m the control part of the circuit from exceeding 250 volts
Motors
For maximum safety each motor should be of the type and size required for the load and for the conditions under which it must op erate Excessive overloading for long penods, use of nonapproved motors in areas contain ing flammable vapors or dusts, and defective wiring are typical of the unsafe practices that should be avoided
The following are common motor problems in industry dust, stray oil, moisture, misalign ment, vibration, overload, and friction
In plant operations, dust is constantly set tling on motors, housings, windings, slip rings, and commutators, and trying to work its way to the bearings The problem of dust