Document 3QB49jkOO8zBL457Yd8MyXvQx
-f Tl/Jo/W MEMCRA|\ DUM
To: Mr. Fred .'il!iams 791 -25
September 13, 1972
From:
Industrial Hygiene
Subject: Air Sampling During "Cutting and rifting of "Kaylo 20"
SUMMARY
Six "personal" air samples were collected during the
application of insulating material containing a percentage
of asbestos. Three samples show results in excess of the Threshold Limit Value
of 5 fibers per milliliter greater than 5 u in length. The operation was performed
at Building 770 by two Construction Department employees.
DISCUSSION
On August 23, 1972, the industrial Hygiene group monitored
asbestos fiber that became airborne during the application
of insulating material containing approximately 15% asbestos at Building 777.
The materia! being used was "Kaylo 20," a dobas^MunvUie product.
The operation included sc wing, shaping, and fitting material 2 inches in thickness.
Each phase of the insulating procedure was carried out during each of the sampling
periods, therefore, each result is a composite of the airborne fibers incident to
individual phases. A portion of the operation was monitored between approximately
9:45 a .m. and 11 :00 a .m. During this time period a considerable amount of waste
"Kaylo 20" accumulated In the work area. In ari area "downwind" of the operation
small airborne particles were visible in the sunlight fora period of time. During
the time of monitoring, insulation was "cut and fitted" to 2 sides of a "pre-heater,"
project Item No. 111. The "pre-heater" was Insulated while outside of the
building and subsequently moved to a permanent position in Cell No, 1 . The
operation was performed by^^m^fc and
The samples were collected by the use of "personal" air sampling equipment. The sample collecting device was suspended around the neck of the insulator as close to the breathing zone as was practical . The airborne fibers wore collected using membrane filter media. Typo AA, 0.8 a pore diameter, whits, 37 mm in size, at 2 Ipm flow rate.
The samples were delivered fa the R&D Pnvircnmental
for analysis.
4 .. ^PLAINTIFF'S
.5 EXHIBIT I I, EXHIBIT
\^h II isivioc)
'ir.nl 0 0 0 R 1
WV-17793
2
RESULTS AND CONCLUSIONS
The attached data sheet shows asbestos fiber*
to be airborne in concentrations and size
greater than the Threshoid Limit Value of 5 fibers per milliliter of air greater than
5u In length as a result of the use of "Kayfo 20."
A review of the application techniques involved in this type operation may be advisable and a clean-up procedure should be initiated.
R.O.M./ebc Att.
uccj.0008
APPLICATION OF "KAYLC 20" BUILDING 777
Date: August 23, 1972
Sampled by: R. G. MidkJff
Sample No.
1 2 3 4 5 6
Sampling Time-Min.
15 15 15 15 15 15
Flow Rate LPM 2 2 2 2 2 2
Flbers/ml >5u In length Insulator
7.0 3.8 4.1 5.9 3.8 5.6
Each sample covered periods of sawing, shaping and fitting pieces of "Kayio 20" Insulation.
. r\f\C\C.C,