Document 3Q9Y6zqjbn0wdpqawNYZp7050
u^
\
\ .a ^il> ^
INTEROFFICE
\0 /
date MARCH 2, 1976
^ECEIV tL)
';hr : 1976 i
W. W. MADDEN
10 MR. C. J. KLEIN2RT
FROM F. F. HOY/X. H. GARNER
REFERRING TO LETTER OF
SUBJECT
VINYL CHLORIDE SAFETY ASSOCIATION MEETING AlLAIvirr GA. 2/277%
Firestone Representatives: X. H. Garner and F. F. Hoy
The meeting was mostly devoted to the OSHA-VCM standard and the proposed EFA-VCM standard. This report is divided into two parts, the general report and an appendix. The first part covers the highlights of the meeting, significant comments or new devel opments ancl a general impression of the status of the various PVC producers in their compliance efforts. The second part outlines the specific comments as each company representative spoke on his company's progress. This latter sect!on is for reference rather than general information.
All but a few of the producers were represented and each V.:ttb allowed five to ten minutes for a presentation. The presenta tions therefore were brief summaries. Not sufficient time was ava.i lab! e to pursue all topics ncr to discuss any .issue in great depth. The meeting was helpful, however, in updating our assessmenu of the problems and successes the industry is encountering in its drive for compliance.
1. The representative from Ethyl reported that a deputy director
of 171031! told their medi cs.1 director in a telephone conver
sation that there is a. cartridge mask under development that
will
V O''! on inhalation and release it on exhalation
giving tne cartridge a 12 hour life. More significantly, in
the same conversation no told their medical director there
is a good chance for a nine month extension of the optional
use of masks while mask improvement continues. No one else
reported any knowledge of this possibility.
Nearly all companies reported they are making regular physics! examinations mandatory as a condition of continued employment with no disagreement from their employees even though 08HA
says the standard does net require it. We got the impression that any who received a militant objection from their em ployees gave up the mandatory stance, however.
OCC 2855
2- -
3. Reported average readings were low, in the range of 0.5 PPM to 2.0 PPM with a few companies reporting averages up to 3.0 PPM. The range for personnel monitoring was about the same. Firestone reported higher readings and specified them for the poly buildings. We believe from comments that these low aver ages included essentially all areas of their plants, even areas we would not list as regulated. Averages such as this are, of course, meaningless except for publicity releases. Nearly all companies, even the monomer producers, admitted numerous ex cursions well above these levels. One company counted 400 excursions above 10 PPM in a month of 50,000 readings.
There were some inconsistent comments in this area. A monomer producer said their whole plant was deregulated but noted the use of self contained air masks for certain specified operations or for all exposures over 100 PPM. On all subjects except ex posure readings, however, the reporting appeared to be frank and open.
4. We concluded that a fev/ plants, notably the new ones, are better off than the Perryville Plant, a number about the same and some worse off. None appeared to have as great a problem as the Pottstown Plant, but we may have been misled. Companies with both older and newer plants may have discussed primarily the newer ones. We concluded also that some plants were farther along with their programs than Firestone and some not so far. We seem to be about at the middle of the pack.
5. The position of most companies on outside contractors is similar to Firestone's. Information is provided and the burden of com pliance is placed on the contractor. Whether this position would satisfy OSHA, no one was sure. Some companies provide equipment and lab service, others provide nothing. A few excluded out side contractors from regulated areas. One had an arrangement for a complement of regular contractor employees and provided the full program as for their own employees. All who mentioned contract maintenance treated them as their own employees.
The most remarkable sitxiation was described by Goodrich. They claimed Kentucky state OSHA officials approved a plant whereby they would evacuate outside contractors if an exposure over 5 PPM occurred and on this basis exclude these people entirely from coverage by the standard. Therefore no physicals, masks or even training are provided.
6. Bendix and Areas chromatographic systems appeared to be preferred for area monitoring. Most either had these systems tied to a computer to calculate averages or were heading in that direction. A few have Hiran systems. One said it was not sensitive enough for their purpose. Number of points monitored per plant ranged from 12 to 80 with the majority using 20 to 30 points.
OCC 2856
-3-
6. Two comranies, Pan to sot e and Georgia Pacific, have previously said they will tie their operators to the area monitors via the computer and avoid monthly checks on individuals. There does not seem to be any groat move in this direction. Host companies who discussed individual personnel sampling take six to eight hour checks with slow, intermittent pumps and tubes rather than the 10 minute samples we take. One com pany used a Jacket with a pouch in the back to hold a Tedlar bag for eight hour samples. No data v/as given for typical TV/A readings for individual operations by any company. All personnel were averaged together to get the 0.5 to 5.0 PPH discussed elsewhere in this summary.
7. The preferred mask is the half face piece, air line mask. Some feed the air line from bottles. Methods to avoid exhaust ing the bottles mostly involved inventory checks. This might not pass an OSHA inspection. . Two companies had nose bleed problems with bottled air. Rust in pipe systems with humidified air can be a real problem. One company is considering a change to plastic pipe. A number of companies use masks in reactors regardless of VCH level. All use some self contained air masks and canister masks along with the air line masks. Some companxes anticipate using canister masks to 25 PPH. Others in tend to use air line masks above 1.0 PPH and minimize canister mask use. In general few employees willingly used any kind of mask in the 1-25 PPH optional range.
A number have held trial mask runs which came to be 'described as "April 1 weeks"./' No one admitted to the resentment of m'atiks which firestone experiences. In answer to a specific question whether mask use haK^to be enforced by reminders during_aue;i a trial run, one reorient ative claimed no riin^vhplTTrewas used and little reminding was necessary. We accepted this without obriras disbelief. Companies with URW organized employees described slight militance in some areas but nothing on the scale of the aggravation at Pottstown.
Rumors we have heard of approved, cartridge masks are not true. No company nad any approval to use cartridge masks at any VCH level. However, Henry Waltemate, a safety manager at B. B. Goodrich said they have federal OSHA approval to use a half mask with a canister for exposures to 10 PPH. Grover Wrenn was involved in the approval. He said they have simply connected a half face mask from a supplied air system to a canister. We have been told a switch of equipment pieces alone would void NIOSH approval. We should check further into this.
Two companies reported OSHA inspectors equipped with cartridge masks. At one plant these inspectors accepted canister masks-, at another, they wore the cartridge masks to inspect regulated areas. MSA and Scott were said to be working on a "transfer" or "combination" mask for use with air or charcoal. Most com panies are eager for this approval. The problem of how to get to an air line mask in a regulated area was discussed but not solved.
OCC 2857
-4-
8. We did not get much, discussion going regarding females in regulated areas. Apparently only a few companies re strict them. Stauffer, one of the companies which did not use females, has now located sex^eral whose application indicated they could not bear children. We were told they had passed an EEQ compliance audit.
PPG reported that at their Lake Charles VCM plant they do
not accept females capable of becoming pregnant for VCM areas. They involved 03HA and EEO in a discussion over this and EEC backed off.
9. John Barr of Air Products described an incident whereby an accidental vent of approximately one and one half pounds of VCM at their laboratory at Piscutaway, N. J. caused a great uproar with air quality people and may adversely affect the industry request to exclude laboratories from the EPA standard. Anyone who needs details can get them from K. Garner or F. HoyC
10. John Barr reported on the EPA standard. Ve already have most
of this information. He felt the situation is too political
for EPA to give much ground. He also noted that because of
the rule-making procedure EPA cannot legally grant any exten
sions beyond two years. It was mentioned that since the rules
are promulgated under section 112, the standard will be ad
ministered by the federal agency rather than turned over to the
individual states. This since the over burdening
was expected by attitude of th.
him to
-FV'p-l
be A~helypf^ u, -lI
4-^-r
Board an'Dears not be be unusual for the state agencies. Ed
Bielil of Atlantic TMTuubbiinng discussed requirements placed, on their
new plant by state aii' quality people that were far reaching
and complex nearly beyond belief. Ke said they had a con
sultant company working for three months to gather the necessary
data.
It was suggested that EPA would eventually get aro -d to comparing the 2 oak monitoring plans submitted by the ' rious pi".Queers and require that all adopt the most vigorous plant sub
mitted. One well received suggestion was that two consecutive 25 FPH readings on an area monitor be regarded as an indication of a leak. Segarding regular checking for small leaks, it was felt by some that 3n acceptable plan would have to include at least a couple hours of checking every day. One attendee felt the leak check could ignor flanges and valves not normally opened and any systems which were pressure checked. Another man said his plant had begun to catalogue and number flanges, valves, etc., but gave up at 4000.
V //-; ( J/1 >7(. K. H. GART1ER
laiG/FFH: Iss
P. P. HOY
OCC 2858