Document 3Q7OZwXVpXXvnkZKXMwxYQ8E6

Monsanto Chemical, Company Anniston, Alabama Plnt Lkwtry STANDARD ANALYTICAL METHOD Method No., 014 k.ed... AROCLORS AND PTBAHOLS Teat Initial and Corroalon Chlorides - Potentlometrlc OAT| IISUIO 2/V60 RITTtN BY WeW.K, RAt l or 2 W.H.K. Thl Methed I 1 Supertaxes n Rpvitpt Itittfvctlsm It.ued Op W ism- This method quantitatively detaralnea tha amount of Inorganic chlorldaa praaant In Aroclors and Pyranols. IWgiMI' 1. 200-ml tall fora baakara (Barrellua type), 8. Magnetic ttlrrer (flabor Scientific Company, Cat. Ho. 14-511*1). 3. Teflon magnetic atlrrlng ber. Thla ber ahould be cylindrical and of one place molded construction, one Inch long (Flaher Scientific Company, Cat. No. 9-311-9). 4. Microburet, 1 ml capacity, graduated la 0.01 ml dlvlelone. 5. Silver electrode (Beckman Cat. Mo. 39261). *6. Glaaa electrode (IAN Cat. Ho. 1199-30). 7. UN pH aaeambly (IAN Cat. No. 7664-A1). B. Uaual laboratory glassware. 074536 MA0WT8: l. Ill Sulfuric Acid - prepared by a 50:50 volumetric dilution of ACS grade HqSO^ with chloride free dlatlllad water. Alwaya pour tha acid Into the water with eonatant eltrrlng. 8. ' --. v 3. 0.0085N AgROg - Dlaaolva 0.4847g. of ACS Grade AgN09 In 1 liter of chloride free dlatlllad water containing 3.0 ml of concentrated HN09. Acetone (chloride free) - 5 Utere of acetone are refluxed with 0.5g. of ACS Grade AgN03 for 1/2 hour. The acetone la than dlatlllad from the AgN03 dlacardlng the flrat 100 ml, to flush the apparatua. 901 Of tha charge la dlatlllad from tha flask and tha contanta of tha flask discarded. Standard Analytical Method Mo. 014 Pas* 2 of 2 BAFETY: Aroclora and Pyranola axa Irritating to tha akin. Tha vapora of hot natarlala ara Irritating to tha ayaa and upper reeplratory eyetam. If accidental contact la node with tha ayaa, flueh Immediately with large quantltlea of water for at leaat IS lnutaa and gat Immediate medical attention. PETgRMIMATIOMt 1. Tara a 200-nl baakar on a beam balance to tha nearaat O.lg. 2. Mia the agnple wall and pour a avail aaount out to rlnae tha l'lp. (Mote: Be aura tha temperature of tha aample la below 50*C.). J. Add 100 l.Og. of aampla to the baakar. Rawelgh to obtain tha weight of (ample. 4. Oalng dean, dry tonga place a magnetic atlrring bar Into the baakar. 5. Add 100 ml of chloride free acetone. 6. Add 2 drope of 1:1 HaSO^. - 7. Stir for S nlnuteo with a magnetic atlrrar. Longer atlrring may be naceeaary for tha higher Aroclora. S. Tha aampla la titrated to tha blggaat potential break with 0.0025 H AgN09, uelng the allvar-glaaa electrode ayatam. ~ Mote: Normal aamplea require extremely email maounta of AgNO,. For thla reaaon the titration la run ualng 0.01 ml additlona and allowing aufflclent time for equilibrium to be eatabllahed before recording the amf change. If a change of 1 ov or leaa la obeerved per 0.01 ml Increment for 5 or 4 additlona, Inereaae the additlona to about 0.05 ml until a largar change la obeerved. Then proceed with 0.01 ml additlona. After corroelon chlorldea on Pyranol 1470 and latartaan PFO will require larger tltratlone. I. kun a reagent blank exactly ae above, omitting the aampla. CALCULATION: Free Chlorldea aa ppm Cl (anla tlter-blk titer') x H AaNO. x 55.46 x 103 i> aampla wt. Report to tha nearaat 0.01 ppm. RRFSREMC1: . .* c Ceneral Electric'a method No. CLTM-1 leaned 1V10/59. HONS 074537