Document 3Q6b968J3eq7jE5aZYyjvLZQ0
EXECUTIVE OFFICES: 730 Third Avenue, New York 17, N. Y.
PLANTS: Baltimore, Md. Bayonne, N. J. Bonham, Texas Cass City, Mich. Chappaqua, N. Y. Clifton Springs, N. Y. * Concord,
N. H. Elkton, Md. Emeryville, Caiif. Hamilton, Ontario Los Angeles, Calif. Memphis, Tenn. Monticello, III. Muncie, Ind. New Brunswick, N. J. * North Adams, Mass. Paiatka, Fla. Perth Amboy, N. J. Providence, R. 1. Quincy, Mich. Rome, N. Y. Roselle, N. J. St. Louis, Mo. St. Petersburg, Fla. Sanger, Calif. Tampa, Fla. Williamstown, Mass.
SALES OFFICES:
Albuquerque, N. M. --2100 Zearing Avenue. N. W.
Minneapolis 20, Minn. --404 W. 79th Street
Amariilo, Texas --323 N. Nelson Street
Newark, N. J. --1071 Hudson Street, Union, N. J.
Atlanta 18, Ga. -- 1401 Ellsworth industrial Drive, N. W.
New Haven, Conn. -- 463 Boston Post Road, Orange, Conn.
Baltimore 18, Md. - 1130 East 30th Street
New Orleans 25, La. -- 3923 Euphrosine Street
Birmingham 5, Ala. --3508 Fourth Avenue South
New York 17, N. Y. -- 420 Lexington Avenue
Boston, Mass. --120 V.F.W. Parkway, Revere 51, Mass.
Philadelphia, Pa. -- 95 South Eagle Rd., Havertown, Pa.
Bristol, Tenn.-- 21 Spruce Street
Phoenix 34, Ariz. --3316 E. Washington Street
Buffalo 2, N. Y. -- 17 Court Street
Pine Bluff, Ark.--National Bldg., 2nd and Pine Sts.
Cape Canaveral, Fia.--5505 N. Atlantic Ave., Coca Beach, Fla. Pittsburgh 33, Pa. --2001 Preble Ave.
Chicago 31, HI. -- 4820 N. Harlem Avenue
Plainview, L I., N. Y. -- Ames Court
Chicago 40, Hi. -- 5447 N. Wolcott Avenue
Portland 10, Oregon -- 2215 N. W. Quimby Street
Cincinnati 37, Ohio -- 7650 Production Drive
Quincy, Mich.-U.S. 112 East
Cleveland 14, Ohio --2875 Superior Avenue
Raieigh, N. C. -- 2323 Campbell Street
Columbus 12, Ohio -- 1140 Chambers Road
Richmond 30, Va. -- 2315 Westwood Avenue
Dallas 7, Texas -- 1620 Oak Lawn
Rochester 23, N. Y. -- 50 Telco Road
Dayton 4, Ohio -- 1256 Stanley Avenue
Rome, N. Y. -- 400 Railroad Street
Denver 16, Colo. --4201 E. 48th Avenue
Sacramento, Calif. -- 915 Fee Drive. No. Sacramento 15, Calif.
Des Moines 17. Iowa --2050 Delaware Avenue
St Louis 39, Mo.-- 4983 Fyler Avenue
Des Plaines, III. --1800 Busse Highway
Salt Lake City 4, Utah -- 22 Jeremy Street
Detroit, Mich. -- 12811 Capital Avenue, Oak Park 37, Mich. San Antonio 10, Texas -- 311 Eads Avenue
El Paso, Texas -- 1042 East Side Bivd.
San Diego 1, Calif. - 520 E Street, Room 811
Emeryville, Calif.-- 6221 Hollis Street
San Francisco 24, Calif. -- 185 Industrial Street
Great Falls, Mont.-1311 3rd. N.W.
Sanger, Calif. --1075 North Avenue
Honolulu 17, Hawaii -- 1035 Kikowaena Place
Santa Monica, Calif. -- 1230 Fourth Street
Houston 20, Texas -- 1340 Hahlo Street
Savannah, Ga. -- Savannah Industrial Park, Ross Road
Huntsville, Ala. -- 212 Gallatin Street, S. W.
Seattle 8, Wash. -- 5210 First Avenue, South
Indianapolis 7, Ind. -- 1735 West 18th Street
Spokane 1, Wash.-- 204 Nelson Bldg., West 106 Mission Ave.
Jackson, Miss.-- 218 Lorenz Blvd.
Springfield, HI. -- 920 N. MacArthur Blvd.
Jacksonville 5, Fla. --455 Roberts Street
Syracuse, N. Y. -- Wave! Street, East Syracuse 6, N. Y.
Kansas City 16, Mo. -- 920 Cable Road
Tacoma 2, Wash. -- 801 East 26th Street
Lincoln, Nebraska -- 5615 Seward Street
Tampa 10, Fla. -- 2515 E. Hanna Avenue
Los Angeles 22, Calif. -- 2933 South Supply Avenue
Tucson, Arlz. -- 2020 E. 13th Street
Louisville 13, Kentucky--4262 Poplar Level Road
Tulsa 5, Okie. -- 6848 E. 41st Street
.
Miami 42, Fla. - 3501 N. W. 60th Street
Washington 1, D. C. -- 261 Constitution Avenue. N. W.
Milwaukee 13, Wise. -- 6520 W. State Street
"Denote* Dirtrlbutin* Center* and Sele* Offices
3
A-1-62
GC 01352
ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC
INSULATED WIRES AND CABLES
Users of all-asbestos and asbestos-var-
mshed cambric wires and cables in all
branches of industry have found the General
Cable Corporation to be a reliable source
of supply not only because of prompt deliv
ery but primarily because of uniformly high
quality of products.
Asbestos, being a mineral fibre, is prac
tically incombustible and indestructible.
The name "asbestos" meaning "uncon
sumed" was coined from the use of this
material for the wicks of the perpetual
lamps in the ancient Greek temples. In
fact, an ancient method of cleaning fabrics
made from asbestos was to place them in a
flame and burn out the materials soiling
the fabric.
Asfcesios provides a truly heat-resisting
insulation suitable for use at temperatures
beyond the limits allowable for other stand
ard forms of insulation.
In most cable applications the asbestos
is used in combination with varnished
cloth. Varnished cloth provides a flexible
insulation of high dielectric strength to
reinforce the normal heat-resisting charac
teristics of asbestos.
As a rule, the varnished cloth tapes are
applied as o layer between saturated lay
ers of felted asbestos.
'
All-asbestos and asbestos-varnished cam-
brie insulated wires and cables manufac
tured by General Cable comply with the
Standards of the National Electrical Manu
facturers Association for such cables.
The following maximum operating tem
peratures are recommended for this class
of insulation, in accordance with these
Standards:
-
GENERAI
All-Asbestos (Unimpregnated, Type A) where no moisture is present..................................... 20QC.
All-Asbestos (Impregnated, Type AI) where moisture is present........................................ I25C.
Asbestos-Varnished Cambric: (a) with Asbestos Braid (Type AVA) or Lead . Sheath (Type AVL) . . IIO^C.
(b) with Cotton Braid (Type AVB)..................................... 90C.
Synthetic-Asbestos with Cotton Braid (Type SNA) .... 90C.
Where operating potential exceeds 600 volts, the permissible temperature should be reduced by 3E degrees, where E equals the operating voltage between conductors ir. kilovolts.
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
GC 02918
revised
PAGE 3
STANDARD TYPES and
USES
ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC WIRES AND CABLES
General Clarification
Tvpe Designation
Construction
Application
Rote: Voltage
Volis
For Complete Descriptions Reter toPooes Listed Below
Power Cables
Asbestos-Varnished
Cambric Boiler Room Wire
Solid conductors of soft an nealed copper, insulated with saturated felted asbestos and varnished cambric, saturated outer asbestos braid.
For general lighting and control circuits, open wiring and con duit work subjected to heat, corrosive fumes, oil. grease, etc.
600
7 to 9,13
Asbestos-Varnished
Cambric Insulated Power Cable
Coarse stranded conductors of soft annealed copper, in sulated with saturated felted
asbestos and varnished cam bric, saturated outer asbestos braid. 600-volt cable also supplied with lead sheath in place of braid.
For general power
wiring inboilerrooms, power plants, steel
mills, industrial plants, etc.
10C0
to 5000
10 to 12
All-Asbestos Power Cable and
All-Asbestos Rheostat Wire
Solid or coarse stranded con For rheostat wiring,
ductors of soft annealed cop ranges, hot plates
per, insulated with saturated and general open
felted asbestos, saturated wiring where exposed
outer asbestos braid.
to heat, fumes,
greases, etc.
600
14. IS
Apparatus Cables
Asbestos-Varnished Flexible stranded conductors
Cambric Apparatus . of tinned, soft annealed cop
Cable
per, insulated with saturated
felted asbestos and varnished
cambric, saturated outer as
bestos braid.
For motor leads, coil connections, trans
former leads, interna! wiring of mining ma chinery, etc.
600
16, 17
All-Asbestos Apparatus Cable
Flexible stranded conductors of tinned, soft annealed cop per. insulated with saturated
felted asbestos, saturated outer asbestos braid.
Where flexible leads must be installed un
der high temperature conditions and where no great amount of moisture is present.
600
16, 17
All-Asbestos Extra-Flexible Motion Picture or Arc Lamp
Cable
Extra-flexible stranded con ductors of soft annealed cop
per. insulated with saturated felted asbestos, saturated outer asbestos braid.
For motion picture projectors, arc lamps, spot lights, etc., re
quiring exceptional flexibility.
300
18
Switchboard Wires and Bus Cables
Gencaseal-Asbestos Switchboard Wire
and Cable
Solid or coarse stranded con ductors of tinned, soft an nealed copper, insulated with Gencaseal and ieited asbes tos, and enclosed m a satu rated outer cotton braid.
For wiring of switch boards.
600
19
Asbestos-Varnished Cambric
Switchboard Wire and Cable
Solid or stranded conductors of tinned, soft annealed cop per, insulated with varnished cambric and saturated felted asbestos, and enclosed in a saturated outer cotton braid.
For wiring of switch boards.
600
20
Asbestos-Varnished Cambric
Switchboard Bus Cable
Coarse stranded conductors of soft annealed copper, insu lated with saturated felted
asbestos and varnished cam bric, and enclosed sr. a sate rated outer cotton braid.
For switchboard bus wiring.
600
21
REVISED
PAGE 4
Junt. 1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
GC 02919
General Claeiiiication
ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC WIRES AND CABLES-- (Continued)
Type Designation
Construction
Appl
Rated
Vohaoe Voits
Fat Co.r.cieie
Descr:c:;cr.s Re:er :c Faaef
Listec Selew
STANDAF TYPES
and
USES-
Switchboard Wires and Bus Cables (Cont'd)
Gencaseal-Asbestos Hinge Cable
Flexible stranded conductors of tinned, soft annealed copper insulated with Gencaseal
and saturated felted asbestos and enclosed in o saturated outer cctton braid.
For hinge or jumper connections or. swing ing panels, etc.
600
Asbestos-Varnished Cambric
Hinge Cable
Flexible stranded conductors of tinned, soft annealed copper, insulated with saturated felted asbestos and varnished cambric, and enclosed in a saturated outer cotton braid.
For hinge or jumper
connectionsonswinging panels, etc.
600
Appliance
Plain Felted
Lead Wires. Asbestos Appliance
Range Wires,
Lead Wire
and
Stove Wires
Solid, coarse, or flexible For wiring ranges, 300
stranded conductors of soft stoves, hot plates, and
annealed copper, insulated other electric heating
with saturated felted asbes- appliances.
__
tos. Also available in three-
conductor twisted assembly.
All-Asbestos Stove Wire
Solid or coarse stranded con ductors of soft annealed cop per, insulated with saturated felted asbestos and saturated outer asbestos braid.
For wiring stoves, ranges, hot plates and other heating appliances.
300
Control Cables
Flexible Cords
Asbestos-Varnished Cambric
Control Cable
Flexible stranded conductors of either size 9 or 12 A.W.G. tinned, soft annealed cop
per. insulated with satu rated felted asbestos and var nished cambric, and enclosed in a dry color-coded cotton braid. For multi-conductor cables the required number of insulated and braided con ductors are assembled by twisting and covered by a tape and a saturated asbes tos braid.
For boiler rooms, power stations, and other locations where
control or signal wir ing is subject to tem
peratures beyond the operating limits of other insulations.
600
Asbestos-Varnished
Cambric Headlight Wire (Single Conductor
Only)
Flexible stranded conductors of tinned, soft annealed cop per, insulated with varnished cambric and saturated felted asbestos and enclosed in a saturated outer cotton braid.
For cab and gauge light wiring on loco
motives, and as ex tension cord in steel
mills, kiln rooms, etc.
603
All-Asbestos Two Conductor
Cord
(Light Duty Cab Cord)
Flexible stranded conductors of soft annealed copper, insu lated with saturated felted asbestos, assembled by twist ing, and covered by a satu rated asbestos braid.
For cab and gauge light wiring on loco motives, and as ex tension cord in steel mills, kiln rooms, etc.
300
Asbestos-Varnished Cambric
Two Conductor Cord
(Heavy Duty Cab Cord)
Flexible stranded, conductors of tinned, soft annealed cop per. insulated with saturated
felted asbestos and varnished cambric, assembled by twist ing, anc covered oy a satu
rated asoestos braid.
For cab and gauge light wiring on loco
motives, and as ex tension cord in steel
mills, kiln rooms, etc., especially where there is exposure to oti, grease, moisture, etc.
600
23 24 25 26. 27
28,29 28. 29 28. 29
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
Cctoloa 37
GC 02920
revised
PAGE 5
2942
revised
PAGE 6
Asbestos--Asbes:o$-Vc:r.:shed Co.-r.crtc Caoies Syracuse Fasseaae: S:ct;cr.. N. V. C. R. R.
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
GC 02921
These constructions are recommended for either open wiring or general conduit work, where operating temperatures are above the limits of other standard insulations-- particularly where subject to heat, flame, oil, grease or corrosive vapors.
Stranded conductors (Power Cables) are normally used as circuit wiring in ash pits and ash pit alleys, around soaking pits, for furnaces, ovens, lehrs, tenter frames, steam tunnels, major boiler room circuits and similar high temperature applications. Braid finished constructions are suitable for general conduit wiring, except where condensation or infiltration provides a moisture hazard. Lead sheaths should be specified for moist conditions.
Solid conductors (Boiler Room Wires) ore normally used in general lighting and con trol circuits, around ovens, furnaces, lehrs, tenter frames, boiler rooms, soaking pits and as elevator and locomotive control panel wiring. This type is also used as switchboard wire, where an overall as bestos braid is required.
Both constructions are approved by Underwriters' Laboratories as Type AVA. or AVL wires. Both types may be handled and pulled into conduit by methods similar to those used with other standard wire and cable constructions. Multi-conductor con structions are also available, as required.
The maximum recommended operating temperature is 1100C.
ASBESTO VARNISH] CAMBRIC POWER CABLES and BOILER ROOM WIRES
Types AV/ and AVL 600 Volts
CONSTRUCTION
< Rfr to pagt 30 and 31 '
Conductors:
Solid (Boiler Room Wires) or coarse stranded (Power Cobles), soft anneaiea copper.
roving, saturated with heat and moistureresisting compound.
Outer Coverings:
Insulation:
(a) Wall of felted asbestos, or asbestos roving, saturated with heat and moistureresistmg compound (excepting for solid con ductor sizes No. 8 A.W.G. and smaller).
(b) Wall of varnished cloth tapes applied as a series of helical wraps and
(c) Wail of felted asbestos, or asbestos
(a) Type AVA: Asbestos braid, satu rated and finished with flame, heat and moisture-resisting compound (standard color --black).
(b) Type AVA: Also available with white heat and flame-resisting finish--on special order, or
(c) Type AVL: Sheath of commercially pure ieaa or special alloy--if so specified.
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength
Resistance to Flame .
.
Dielectric Strength--following Flame Tes
Dielectric Strength--Corine immersicr.
Refer to page 31 Refer to page 32 Refer to page 32 Refer to page 32
Ns: =
t; 7vr, AVL Csni*.-
GENERAL CABLt CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED
revised
CAMBRIC INSULATED WIRES AND CABLES
PAGE 7
C a o J o 3 37
\>ty
Jun*. 1942
GC 02922
ASBESTOSVARNISHED CAMBRIC POWER CABLES and BOILER ROOM WIRES
Types AVA and AVL 600 Volts
Six* C.M. or A.W.C.
1.000.000 900.000 800.000 750.000 700.000
650.000 600.000 550.000 500.000 <50.000
400.000
350,000 300.000
250.000 4/0
3/0
2/0 1/0
l
2
3
5
6 e
10 12 14 16 18
CONDUCTORS ............ .. ' ............
--------
.
Diameter Incnss
61 x . 128C" 61 x .1215" 61 x 1145" 61 x H09" 61 x . 1C71"
61 x .1032'' 61 x .0992" 61 x .0950" 37 x .1162'' 37 x .1103"
37 x .1040" 37 x .-0973" 37 x .0900" 37 x .0522" 19 x .1055"
19 x .0940" 19 x .0637" 19 x .0745" 19 x .0664" 7 x .0974"
7 x .0867" 7 x .0772" 7 x .0688" 7 x .0612" 7 x .0486"
7 x .0385" 7 x .0305" 7 x .0242" 7 x .0192" 7 x .0152"
1.152 1.094 1.03!
.998 .964
.929 .893 .855 .813 .772
.728 .68! .630 .575 .528
.470 .419 .373 .332 .292
.260 .232 .206 .184 .146
.116 .092 .073 .058 .045
STANDARD SIZES, DIMENSIONS
INSULATION THICKNESS
BRAID FINISHED CAB _ES
First Mils
Mils
Mils
Mils
,,
Overol. Diameter
incrtes
Weioh: per
1000 Ft. Net Lbs
ASBESTOS-VARNISHED CAMBRIC
30
<0
40
45
1.465
351C
30
40
40
45
1.405
3162
30
40
40
45
1.345
2854
30
40
40
45
1.310
268?
30
4*
40
45
1.275
2524
30
40
40
45
1.240
2359
30
40
40
45
1.205
2193
30
40
40
45
1.165
2027
25
40
40
45
1.115
1855
25
40
40
45
1.075
1687
25
40
40
45
1.030
1505
25
40
40
4S
.965 '
1353
25
40 40
45
.930
1184
25
40
40
45
.875
1014
20
30
30 -- 45
.780
839
20
30
30
4S
.720
69C
20
30
30
45
.670
S7I
20
30
30
45
.625
476
20
30
30
45
.555
371
15
30
20* 45
.515
290
15
30
20* 45
.480
240
15
30
20* 45
.455
200
15
30
20* 45
.430
168
IS
30
20* 45
.405
143
10
30
IS* 45
.350
10C
10
30
IS* 45
.320
77
10
30
IS* 45
,295
61
10
30
15* 45
.275
49
10
30
IS* 45
.260
43
50
30
15* 45
.245
37
ASBESTOS-VARNISHED CAMBRIC
4/0 3/0 2/0 1/0
2 4 $ 8 10
12 14 16 18
Solid Solid Solid Solid Solid
Solid Solid Solid Solid Solid
Solid Solid Solid Solid
.460
20
30
30
45
.710
803
.410
20
30
30
45
.660
660
.365
20
30
30
45
.615
S46
.325
20
30
30
45
.575
425
.289
20
30
30
45
.540
350
.258
15
30
20
45
.480
279
.204
55
30
20
45
.425
193
.162
15
30
20
45
.385
138
.128
3C
20
45
.320
90
.102
30
20
45
.295
7C
.081 .064 .05! .040
30
2C
45
.275
55
30
20
45
.255
47
3: 20 45 .245 40
30
20
45
.230
3c
These thicknesses apply to braid iinnhed cables: lead sheothed cobles hove second asbestos wall of 25 mils minimum average thickness.
Sucieci id = 5Cf tolerance in overall dimensions.
Tne ooove data are approximate ond
revised
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
PAGE 8
CAMBRIC INSULATED WIRES AND CABLES
June. 19*2
'>$'
Catalog 37
GC 02923
WEIGHTS AND PACKAGES
LEAD SHEATHED CABLES
Minimum Avercge
Sheath Thicuness
inches
Overall Diameter
Inches
Weight
per 1000 F:
Net Lbs.
POWER CABLES
STANDARD PACKAGES
BRAID FINISHED
Fee:
Weia.v. per 1000 Ft Gross Les
LEAD SHEATHED
Fee:
Weigh: pe- : X0 Ft
Gross Los
Dielectric
,, Test Voltooe
Volts
6/64 6/64 6/64 6/64 6/64
6/64 6/64 6/64 S/64 S/64
5/64 S/64 S/64 S/64 4/64
4/64 4/64 4/64 4/64 4/64
3/64 3/64 3/64 3/64 3/64
3/64 3/64 -- 3/64 -- 3/64 -- 3/64
1.560 1.505 1.440 1 4i* 1.375
1.340 1 3CS 1.265 i. 180 t.140
1.095 1.050 1.000
.945 .615
.755 .705 .660 .620 .560
.495 .470 440 42C .370
.340 .320 .300 .283 .270
, 5613 5201 4783 4S7-7 4356
4140 3923 3766 3062 2848
2632 2413 2183 1965 1516
1313 1144 1005 890 730
532 477 425 385 289
281 247 222 206 192
500 {Reel' 500 (Reel' 500 (Reel 500 (Reel 507 (Ree:
S00 iReel' 500 (Reel' 500 (Reel' 500 (Reel. 500 'Reel!
SCO .'Reel) S0C (Reel 500 (Reel! 500 (Reel: 1000 (Reel-
1000 (Reel) 1000 (Reel1 1000 (Reel) 1000 (Reel) 100C (Reel)
1000 (Reel) 1000 (Reel1000 (Reei) 1000 (Reel 5oc (Cod;
S0C (Coil) 100C (Coil) ICOC (Coil? 1000 (Coil) 1000 (Coil:
3912 3534 3256 3019 2926
2761 2523 2357 2185 2C17
1835 1683 1514 1344 10C4
855 736 576 471 390
340 300 268 243 105
81 66 55 49 44
500 (Reel) 5X (Reel' 502 .Ree. 5-00 (Reel1 50C -Reel'
500 iReeO 5X `.Reel'500 (ReelSOT (Ree.500 (Reel'
500 (Reel) 500 (Reel: 500 (Reel? 500 (Reel) 1000 (Reel'
1000 (Ree!) 1000 (Reel) 1000 (Reel! 1000 (Reel' 1000 (Reel'
1000 (Reel) 1000 (Ree!) 1000 (Reel) 1000 (Reel1000 (Reel)
1000 (Reel1000 (Reel' 10X (Reel1000 (Reel. ICOC 'Reel
6363 771 5353 4972 4758
4542 4325 4188 3462 3248
2962 2743 2513 2286 1717
1478 1309 1170 1055
830
632 577 525 485 347
325 291 261 245 23!
4000 4002 4*:: 4x: 4X2
4000 4000 4000 4X0 4002
4X0 49OT 4000 4000 3000
3COO 3000 3000 3000 SOX
3000 3000 3000 300C 2500
25OT 2500 2SX 250C 2SX
Sts* C.M. or A.W.G.
1.000.000 900.000 600.000 750.000 700.000
650.000 600.000 550.000 500.000 450.000
400.000 350.000 300.000 250.000
4/0
ASBESTOS VARNISHE] CAMBRIC POWERCABLES and BOILER ROOM WIRES
Types AVA and AVL 600 Volts
3/0 2/0 1/0
1 2
3 4 S 6 6
10 12 14 16 18
BOILER ROOM WIRE
SUPPLIED ON SPECIAL ORDER
ONLY
500 (Reel) 500 (Reel) SOT (Reel) 500 (Reel! 1000 (Reel)
1000 (Reel) 1000 (Reel) 1000 (Ree!)
SOT (Coil) 1000 (Coil)
1000 (Coilr iOOC (Coil) 1000 (Ceil) 1000 (Coil)
953 760 646 525 <50
379 293 236
Oft 7C
61 -- 45 41
.... .......... ... ............... ..................
.................. .... .................
....
............... .. .............
"*Si:e No. 12 A.W.G. ana smaller can be supplied with alternate 2/64" lead sheoths. subiect to normal manufacturing tolerances.
... . .... ____ .. .
. ... .... ____ ....
.... . ..
.. . ..
3000 3000 3000 3000 3000
3000 3000 3000 2OX 2OTC
2000 20X 2000 2OX
4/0 3/0 2/0 1/0
i
2 4 6 8 10
12 14 16 18
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED
CAMBRIC INSULATED WIRES AND CABLES
r-
\y
GC 02924
revised
PAGE 9
jun. 1M2
ASBESTOSVARNISHED CAMBRIC POWER CABLES
Types AVA and AVL 1000-5000 Volts
These cables are recommended, either for open wiring or in conduits, for general power circuits in boiler rooms, power plants, steel mills, industrial plants and other locations where the operating temper atures are above the normal limits of other standard insulations. The maximum recom mended operating temperature for these constructions is (110--3E)6C., where E rep resents the operating voltage between con ductors in kilovolts.
Standard braid finished constructions are recommended for all applications where cables are not subject to either continuous
immersion or severe moisture hazards. For such locations as tidewater level installa tions or in conduits subject to pocket con densation, Type AVL lead sheathed cables are recommended.
Interlocking armor jacketed types are also available for indoor rack installations, to replace conduit. Metallic shielding tapes can be furnished, and are especially rec ommended for those locations where there may be shock hazards.
All types can be furnished in either single or multi-conductor constructions, as desired.
CONSTRUCTION
(Refer to page* 30 and 3l!
Conductors:
Coarse stranded conductors of soft an nealed copper.
(c) Wall of felted asbestos, saturated with flame, heat and moisture-resisting com pound.
Insulation: (a) Wall of felted asbestos, saturated with
flame, heat and moisture-resisting com pound.
(b) Wall of varnished cloth tapes applied as a series of helical wraps.
Outer Covering: Asbestos braid, saturated and finished
with flame, heat and moisture-resisting com pound (standard color--black).
NOTE: Also available with white heat and flame-resisting finish--on special order, or lead sheath.
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength............................................... Refer to page 31
-Dielectric Strength--while Immersed .... Refer to page 32
-Resistance to Flame.........................................
. Refer to page 32
-Dielectric Strength--following Flame Test .
. Refer to page 32
* Ns: applicable :o Type AVI Copies
revised
PAGE 10
Jun. 19*2
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
CAMBRIC INSULATED WIRES AND CABLES
Cotoioo 27
GC 02925
ANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
ASBESTOS-
,'haM Volt*
CONDUCTORS
INSULATION THICKNESS Minimum Average
Sis* C.M. or A.W.G.
Construc Diameter First Varnished Second
tion
Inches Asbestos Catr.rr:: Asoestos
Mils
Braid Thick
ness Miis
Weigh:
Overall
per
Diameter 1000 Ft.
Inches Net Los.
STANDARD PACKAG ES
Fee:
Wt. per
lOOOFt. Gross
Lds
DieiectriTest
Voltage Volts
VARNISHEE CAMBRIC POWER-
1000 1.000.000 61 i .1280" 1.152 900.000 61 * .1215" 1.094
30 30
CABLES40
45
1.475
352:
500 (Reel!
391 i
4500
40
45
1.415
3187
SCO (Reel)
357?
4500
800.000 oi x .) 145" 1.031 750.000 6! x .nw .998
30 30
Types AVA40
45
1.355
2853
500 (Reel)
3243
45X
40
45
1.320
2687
SCO (Reel:
2967
4500
700.000 61 x .1071" 650.000 61 x .1032"
.964 .929
30 30
40
45
1.285
2521
500 (Reel)
262!
4500
and AVL40
45
1.250
2355
500 (Reel)
2655
4500
600.000 61 x .0992" . S50.000 61 x .0950"
.893 .855
30 30
100040
45
1.215
2189
500 (Reel!
2489
4500
40
45
1.175
2023
500 (Reel)
2323
4509
500,000 37 x .1162" .813
ox
40
45
1.12S
1847
SCO (Reel'
2087
4500
and450,000 37 x .1103" .772
-1C
45
40
45
1.085
1681
500 (Reel)
192!
4500
2000400.000 37 x .1040" .723
25
45
40
45
1.040
1515
500 (Reel)
1711
4500
3SO.OOO 37 x .0373" .681
05
45
40
45
.995
1349
500 (Reel)
1498
4500
Volts300.000 37 x .0900" .630
25
45
40
4S
.940
1183
500 (Reel)
1333
4S0C
250.000 37 x .0622" .575
25
45
40
45
.885
1014
SOD (Reel)
1164
45X
4/0 19 x .1055" .528
20
45
30
45
.810
8S7 1000 (Reel)
977 4SOO
3/0 19 x .0940" .470
20
45
30
45
.750
708
1000 (Reel!
82S 4500
2/0 19 x .0837" .419
20
45
30
4S
.700
SS8 1000 (Reel)
708 4500
1/0 19 x .0745" .373
20
45
30
45
.655
491 1000 (Reel)-- 591 4500
1 19 x .0664" .332
20
45
30
45
.615
413 1000 (Reel)
513
4500
2 7 x .0974" .292
15
45
25
45
.555
310 (000 (Reel)
410
4500
3 7 x .0867" .260
15
45
25
45
.520
260 1000 (Reel)
360 4500
2S4 7 x .0772" .232
15
45
45
.495
219 1000 (Reel)
319
4590
5 7 x .0688" .206
15
45
25
45
.470
185 1000 (Reel)
285 4500
6 7 x .0612" .184
15
45
25
45
.445
159 1000 (Reel)
259 4500
8 7 x .0486" .146
15
45
25
4S
.405
115 500 (Coil)
120 3590
10 7 x .0385" .116
IS
45
25
45
.375
90 S00 (Coil)
94 3500
12 7 x .030S" .092
IS
45
25 45 -3S0 72 1000 (Coil) 75 3500
14 7 x .0242" .073
IS
45
25
45
.33S
57 1CCO (Coil)
60 3500
2000 1.000.000 61 x .1280" 1.152
30
60
40
45
1.505
3558
500 (Reel)
900.000 61 x .1215" 1.094
30
60
40
45
1.445
3230
500 (Reel)
$00,000 61 x .1145" 1.031
30
60
40
45
1.385
2907
500 (Reel)
750.000 61 x .1109" .998
30
60
40
45
1.3S0
2738
S00 (Reel)
700.000 61 x .1071" .964
30
60
40
45
1.315
2569
S00 (Reel)
650.000 61 x .1032" .929
30
60
40
45
1.280
2403
500 (Reel)
600.000 61 x .0992" .893
30
60
40
45
1.245
2236
S00 (Reel)
5SO.OOO 61 x .O9S0" .855
30
60
40
45
1.205
2066
S00 (Reel)
SOO.OOO 37 x .1162" .813
25
60
40
45
1.155
1866
500 (Reel)
450.000 37 x .1103" .772
25
60
40
45
1.115
1702
SCO (Reel)
400.000 37 x 1040" .723
25
60
40
45
1.070
1537
500 (Reel)
350,000 37 x .0973" .681
25
60
40
45
1.025
1362
SOO (Reel)
0300.000 37 x .0900" .630
25
40
45
.970
1190
SOO (Reel)
250,000 37 x .0822" .575
25
60
40
4S
.915
1018
500 (Reel)
4/0 19 x .1055" .528
20
60
30
45
.840
878 1000 (Reel)
3/0 19 x .0940" .470
20
60
30
45
.780
715 1000 (Reel)
2/0 19 x .0837" .419
20
60
30
45
.730
S94 1000 (Reel)
1/0 19 x .074S" .373
20
60
30
45
.685
492 1000 (Reel)
1 19 x .0664" .332
20
60
30 45
645 412 1000 (Reel)
2 7 x .0974" .292
15
60
25 45
555 324 1000 (Reel)
3 7 x .0867" .260
15
60
45
.550
269 1000 (Reel)
2S4 7 i .0772" .232
15
60
45
.525
233 1000 (Reel)
S 7 x .0698" .206
15
60
25
45
.500
197 1000 (Reel)
6 7 x .0612" .184
15
60
25 45 475 172 1000 (Reel)
8 7 x .0486" .146
15
60
25
45
.440
130 ICOO (Reel)
10 7 x .0385" .116
15
60
25
4S
.410
104 1000 (Reel)
12 7 x C3C5" .092
15
60
25
45
.385
85 1093 (Rel:
14 7 x .0242" .073
15
60
45
.365
70 ICOO 'Reel'
:eran?e *n
dimensions
The ooove data ore approximate and suoject to normal manufacturing tolerances.
3960 3632 3309 3140 2971
2805 2638 2468 2266 2102
1777 1602 1430 1258 998
835 714 612 532 424
359 333 297 272 230
204 185 I/O
6000 6000 6990 6000 6000
6000 6000 6000 6090 6CCO
6000 6000 6000 6000 6000
6090 6CCC 6CC0 6000 5500
55CC 5500 5000 5CC0 4500
4 SCO1 4 so: 4>X
GtNERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
Crnolae 37'
GC 02926
revised
PAGE 11
June. 1942
ASBESTOS-
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
VARNISHED CAMBRIC POWER
Rated Voltag* PhaB#
to Pha>e
Veit*
Sice C.M. or A.W.G.
non
Inches
INS'-TATION THICKNESS .
Minimum Average
Braid
Thicx-
First Varnished Second Asoestes Corr.c::c Ascestos
ness Mils
Mil s
Mils
Mils
Weigh:
Overall
per
Diometer 1000 ft.
STANDARD PACKA
Feet
Wt.per 1000 Ft
Gross Los
Dieiecir: Test
Voltage Volts
CABLES
Type AVA 3000
and
5000 Volts
3000 1.000.000 61 z .1280" 1.152
30
67
40
45
1.545
3597
500 'Reel.-
3992
9000
900.000 61 x .1215" 1.094
30
87
40
45
1.485
3257
S00 iReei;
36S7
9000
800.000 61 x .1145" 1.031
30
80
40
45
1 425
2974
SCO (Reel)
3326
9000
750.000 61 x .iice" .996
30
87
40 45 1.390
500 (Reeii
3157
900C
700.000 65 x .1C71" .964
30
80
40 45 *
2585
SCO (Reel!
2967
90CC
650.000 61 x .1032" .929
30
87
40
45
1.3-7
2417
SCO (Reel)
2814
9000
600.000 61 x .0952" .893
30
80
4C
45
1.265
2284
SCO (Reel-
2647
9000
550,000 61 x .0550" ,855
3C
60
4C
4S
1.245
2074
SCO (Reel)
2476
9COO
500.000 37 x .1162" .613
25
67
40
45
1.195
19C5
SCO (Reel)
2375
9000
<50,000 37 x -l 103" .772
25
60
4C
45
1.155
1736
500 (Reel)
2136
9070
400.000 37 x .1040" .728
25
80
40
45
i.ttc
1567
500 (Reel)
1962
9CCC
350.000 37 x .0573" .601
25
80
40
45
1.065
1392
500 (Reel)
1633
9000
300.000 37 x .09CC" ;630
25
80
40
45
1.0.7
1219
500 (Reel)
1459
9000
250.000 37 x .0522" .575
25
60
40
45
.95S
1044
SCO (Reel)
1284
9000
4/0 19 x .1055" .528
20
89
30
45
.680
907
1000 (Reel*
HOC
6503
3/0 19 x .0940" .470
20
80
30
4S
.820
746 1000 (Reel)
866
8500
2/0 19 x .0637" .419
20
80
30 45
770
625
1000 (Reel)
745 8500
1/0 19 x .0745" .373
20
80
30
45
.725
525
1000 (Reel)
647
8500
1 19 x .0664" .332
20
80
30
45
.685
445
1000 (Reel:
565
8SCO
2 7 x .0974" .292
IS
80
25
45
625
368 1000 (Reel)
536
8000
.*
3 7 x .0667" .260
IS
60
25
45
.S97
315 10CO (Reel)
415
8000
4 7 x .0772" .232
IS
SO
25
45
.565
245 1CC0 (Reel)
345
8700
S 7 x .0688" .206
15
80
25
45
-5<0
21C 1000 (Reel)
310
7500
6 7 x .0612" .184
15
80
25
45
.515
187 1000 (Reel; 262 7500
8 7 x .0486" .146
IS
80
25
45
.480
143 10CO (Reel) 243 7000
10 7 x .0385" .116
15
80
25
45
.450
115 10C0 (Reel) 21S 7000
12 7 x .0305" .092
15
80
25 45 .425 95 1000 (Reel; 195 7CCO
14 7 x .0242" .073
15
80
25 45 .405 80 1000 (Reel; 180 7000
revised
PAGE 12
Jur... !9<2
5000
i.000.000 61 x .1260" 900.000 61 x .1215" 800.000 61 x .1145" 750.000 61 x .uce" 700.000 61 x .1071"
1.152 1.094 1.031
.998 .964
650.000 61 x .1032" 600.000 61 x .0992" 550.000 61 x .0950" soo.ooo 37 x 1162" 450.000 37 x .1103"
.929 .893 .855 .813 .772
400.000 37 x .1040" 350.000 37 * .0973" 300.000 37 x .0900" 250.000 37 x .0822"
4/0 19 x .1055"
.728 .681 .630 .575 .528
3/0 19 x .0940" .470 2/0 19 x .063?" .419 1/0 19* .074S" .373
l 19 x .0664" .332 2 7 x .0974" .292
3 7 x .0667" .260 4 7 x .0772" .232 S 7 x .0686" .206 6 7 x .0612" .184 8 7 x .0486" .146
10 7 x .0385" .116 12 7 x .0305" .092 14 7 x .0242" .073
30 30 30 30 30
30 30 30 25 25
25 25 25 25 20
20 20 20 20 IS
IS IS 15 15 IS
15 15 IS
12C 120 120 120 12C
120 120 12C 120 120
120 120 120 120 120
120 120 120 120 120
120 120 120 120 120
120 120 120
40
45
1.625
3721
530 (Reel!
4C
45
1.565
3379
SCO (Reel:
40
4S
1.505
3040
SCO IReei)
40
45
1.470
2876
500 (Reel)
40
45
1.435
2701
500 (Reel'
40
45
1.403
2532
500 (Reel)
40
45
1.365
2362
SCO (Reel)
40
<5
1.325
2190
500 (Reel)
40
4S
1.275
1993
500 (Reel'
40
45
1.235
1821
SCO (Reel)
40
4S
1.190
1653
500 (Reel)
40
45
1.145
1482
500 (Reel)
4C
45
1 090
1307
570 (Reel)
40
45
1.035
1137
500 (Reel)
30
45
.960
967 1000 (Reel!
30 45
900
812 1000 (Reel)
30
45
.850
687 1000 (Reel)
30
45
.80S
582 ICCO (Reel'
30
4S
.765
497 1000 (Reel!
2S
45
.705
402 1000 (Reel!
25
4S
.670
363 1070 (Reel)
2S
45
.645
319 10C0 (Reel)
25
4S
.620
285 ICCO (Reel)
25
45
.595
2S1 ICCO (Reel)
25
45
.560
182 1000 (Reel:
25
45
.530
152 1000 (Reel;
25
45
.505
132 ICCO (Reel:
25
45
,4es
1 17 ICCO (Reel
Subieci :c z 5*^ toleronce :n overall dimensions. The aoove doto ore opprcximote ond subject to normol manufacturing tolerances.
4291 3949 3442 3278 3103
2934 2764 2592 2393 2221
2053 1882 1S47 1377 1167
1012 887 702 617 522
483 433 405 351 282
252 232 217
12000 12000 12000 12000 12000
12070 12000 12070 12070 12000
12000 12000 12000 12000 12000
12000 12070 12000 12000 12000
12000 12CC0 12000 12000 12000
12000 12000 12000
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
CAMBRIC INSULATED WIRES AND CABLES
Catalog 37
GC 02927
Where multi-conductor cable is required, three single conductor cables minus their outer braids, cabled together with jute tillers, taped and covered with a heavy
asbestos braid, is recommended. Asbestos ASBESTOS
fillers, lead sheathing or armoring can be furnished.
VARNISHEI
CAMBRIC
POWER"
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES;
CABLES
... Six* C.M. or A.W.G.
SOO.QOO 450,000 400,000 350.000 300.000
CONDUCTORS
Construction
37 x .no: 37 x .110337 x .104037 x .097337 x .0900
Diameter Inches
.813
.728 .63; .632
Overall Diameter
Inches
2.35C 2.265 2.170 2.070 1.955
Weight ir.v- c. Net Los
6076 5527 4979 4426 3869
STANDARD PA CKAGS5
feet
V,*- p*r Gross Lz:
500 .Reel500 'Reel' 500 'Reel) 500 (Reel' 500 `Reel
759: 690? 6224 5533 4336
Type AVMA Three Conductor 600 Volts f
250.000 4/0 3/0 2/0 1/0
37 x .0822\9 x .105519 x .094019 x .083719 x .0745"
.575 S25 .473 .419 .373
1.83S 1.610 1.480 1.370 1.275
3298 2680 2ie9 1806 i486
S00 (Reel! 500 (Reel500 'Reel! 1000 (Reel' 1000 (Reel
4123 3350 2736 2358 1358
1
IS x .0664"
.332
1.190
1238
1000 (Reel:
1543
2
7 x .0974"
292
1.015
952
1000 (Reeh
1190
s
7 x .0867"
.260
.940
793
1000 (Reel!
991
4
7 x .0772"
.232
.885
661
1000 (Reel!
826
5
7 x .0688"
.206
.835
560
1000 (Reel!
700
$ 7 x .0610"
.780 474 1000 -Reel'
593
8
7 x .0486"
.146
.705
352
1000 iReel!
440
10
7 x .0385"
.116
64C
270
1000 (Reel!
338
12
7 x .030S-
.092
.535
217
1000 (Reel-
271
TMulti-conductor power cables for higher rated voltages, with individual conductors as shown ,n preceding pages ore olso ovailaole. 2600-volt multi-conductor power cable assembled with stngie conauctor cables descnoed or. pages 7 to 9. Subject to i5% tolerance in overall dimensions.
The coove data are approximate one subiect to normol manufacturing tolerances
typical Multi-Conaucior Asbestos-V'arr.ished Cambric: Power Cable
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES GC 02928
revised
PAGE 13
ALL
ASBESTOS
POWER
CABLES and
All-Asbestos Power Cable
RHEOSTAT
WIRES Type AI
All-Asbestos Rheostat Wire
600 Volts
Recommended for open wiring applica tions, subject to extreme heat or fire hazards, such as rheostats, furnaces and oven con nections. Also applicable to switchboard wiring or elevator and control panel wir ing--rated at 00 volts or less. These con structions have adequate electrical and moisture-resisting properties to allow bunchwired installations with perfect safety as
grid jumper connections, connections be tween grids and faceplates, etc.
The following maximum operating tem peratures are recommended:
Where no. moisture is present........................... 200C.
Where moisture is present, 125C.
CONSTRUCTION
(Rfr to pag 30 and 31 )
Conductors:
Outer Covering:
Solid (Rheostat Wires) or coarse stranded (Power Cables) of soft annealed copper.
Asbestos braid, saturated anc finished with flame, heat and moisture-resisting compound (standard color--black).
Insulation:
Wall of felted asbestos, or asbestos rov ing, saturated with flame, heat and mois ture-resisting compound.
NOTE: These types are also available with the insulation and outer braic saturated and coated with special heat and flame-resisting compound (stand ard color--white).
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength........................... Resistance to Flame........................................ Dielectric Strength--following Flame Test. Dielectric Strength--during Immersion .
Refer to page 31 Refer to page 32 Refer to page 32 Refer to page 32
REVISED
PAGE 14
Ju r>. ]943
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORP^0*'1'"'"'
CAMBRIC INSULATED WIRES AND CABLES Cotoiog 37
GC 02929
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
Size _
C.M. or Construction Diameter
A.W.C.
Incnes
Asbestos
Insuicuon Thickness Minimum.
Average Miis
Asbestos Braid Thick
ness Miis
Overall Diameter
Incnes
Weight
per 1000 Ft
Net -cs
STANDARD PACKAGES
Fee:
Number o! Coiis
per Canon
Weigh: oer
!COC F:. Gross Lcs
Die.ectr::
Ter
Voitooe Voits
ALL-ASBESTOS POWER CABLES
1.000.000 900.000 800.000 7S0.000 700.000
6! x .1280" 6! x .1215" 61 x .1145" 61 x .1108" 61 x .1071"
650.000 600,000 550.000 SOO.OOO 450.000
61 x .1032" 61 x .0992" 61 x .0950" 37 x .1162" 37 x .1103"
1.152 i .094 1.031
.998 .964
.929 .893 .855 .813 .772
75 10S 175 1C5 i.r-e
105 105 105 90 90
45
1.455
353C
500 (Ree:;
45
1.395
3198
507 (Reel!
45
1.335
2866
SCO (Ree!)
45
1.377
2699
500 (Reel)
45
1.265
2536
SCO tReell
45
1.237
2371
$00 (Reel)
45
1.195
227-4
500 (Reel)
45
1.155
2037
SCO (Reel)
45
1.085
1814
SCO (Reel)
45
1.045
1658
S00 (Reel)
3937 367-7 3366 3101 2938
2773 2606 2367 2144 1986
150C iscc 1SCC 150C 150C
1500 1507 1507 I5CO 1S0C
ALL ASBESTOS POWER CABLES and RHEOSTAT WIRES
Type AI 600 Volts
400.000 37 x .1040"
.728
90
45
1.007
1505
500 (Reel)
350.000 37 x .0973"
.681
90 45
.955
1329
SCO (Reel)
300.000 37 x .0900"
.630
90
45
.900
1151
500 (Reel)
250.000 37 x .0822"
.575
9C 45
.645
989
SCO (Reel)
4/0
19 x .1055"
.S28
75
45
.770
831 1000 (Reel)
1835 1659 i4Sl 1167 -- 996
ISCC 1500 ISCC 1570 1500
3/0 19 x ,0940"
.470
75 45
.710
679
1CCO (Reel)
2/0
19 x .0837"
.419
75 45
.660
555 1CC0 (Reel!
1/0 19 x .0745"
.373
75
45
615
467 1000 (Reel)
I 19 x .0664"
.332
75 45
.575
379 1C00 (Reel)
2 7 x .0974" .292
60 45
.505
274 1000 (Reel)
844 724 629 479 374
ISCC 15CC ISCC 1500 I50C
3 7 x .0867" .260
4
7 x .0772"
.232
S 7 x .0688" .205
6 7 x .06J2" .184
8 7 x .0486" .146
60 45 60 4S 60 45 60 45 40 45
.470 .445 .427 .395 .320
227 10CO (Reel) 188 1000 (Ree!) 157 I0CO (Reel) 132 ICOO (Reel) 98 SCO (Coil)
327 150C 288 15CC 257 ISO-' 232 1507 171 ISCC
10 7 x .0385" .116
12
7 x .0305"
.092
U 7 x .0242" .073
16 7 x .0193" .058
ie 7 x .0151" .045
40 45 40 45 30 45 3C 45 30 45
.290 .265 .225 .217 .195
75 500 (Coil) 60 1000 (Coil) 44 ICOO (Coil) 36 10CC (Coil) 34 1000 (Coil)
1 4 4 5 5
78 1500 63 1500
4? ISCC41 1500 27 1500
ALL-ASBESTOS RHEOSTAT WIRE
4/0 3/0 2/0 1/0
1
2 4 6 8 10
12 14 16 18
Solid Solid Solid Solid Solid
Solid Solid Solid Solid Soiic
Solid Solid Solid Solid
.460 .410 .365 .325 .289
.253 .204 .162 .128 .102
.081 .064 .051 .040
6C 45 60 45 60 45 60 45 60 45
40 45 40 45 40 45 3C 45 30 45
30 45 27 45 30 45 30 45
.670 .620 .575 .535 .500
.432 375 .335 .267
.235 .2:5 275 .19:
765 624 46! 392 322
25C 170 IIS
86 66
7 45 37
500 (Reel) SCO (Reel! 500 (Reel) 507 (Reel) 1000 (Reel)
1CCO (Reel.1000 (Reel)
S00 (Coil) 500 (Coil) 1000 (Coil)
ICOO (Coi)' 10CO (Coil) IOCO(CoiI) ICOO (Co-1)
.. .. .. .. ..
.
.. 1
4 4 5
Sobiect to s 5^ toleronce if) over oil dimen ions. The coove oaio are opprcxitr.cte cr.c suoiet: :c normal manufacturing tolerances.
965 1500 824 1500 681 1500 S92 ISCC 422 ISCC
350 1500 270 1507 12! 1SCO
Q; ISCC 69 ISCC
5 1507 46 1507 47 1507 36 iso:
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED <pp2|}> revised
CAMBRIC INSULATED WIRES AND CABLES
PAGE 15
Ccioicc ^7
Vxv
*r*n. 1942
GC 02930
ALL
ASBESTOS and
All-As'oesics Appcratus Cabie
ASBESTOS-
VARNISHED
CAMBRIC
APPARATUS
Asbesros-Vamished Cambric Appara:cs Caoie
and
MOTOR LEAD
Flexible stranded constructions, recom mended for wiring of all low-voltage appa ratus in power plants, steel mills, foundries,
cambric types may be used tor either open wiring or in conduits.
Maximum recommended operating tem
CABLES
Types AI and AVA
boiler rooms, ash pits, cranes or other ap plications where operating temperatures are above the limits of other standard in sulations.
All-asbestos constructions are recom
peratures:
1 --All-Asbestos Types: Where no moisture is present. 200C. Where moisture is present. . 125C.
600 Volts
mended only for open wiring (such as jumper leads) while asbestos-varnished
2--Asbestos-Varnished Cambric Types.................................... 110C.
CONSTRUCTION
l Refer to page* 30 and 31 1
Conductors: Flexible stranded conductors of tinned,
soft annealed copper.
Insulation: 1-- All-Asbestos Type: Wall of felted as
bestos, saturated with flame, heat and moisture-resisting compound.
2-- Asbestos-Varnished Cambric Type:
(b) Wallof varnished cloth tapes applied as a series of helical wraps. (c) Wall of felted asbestos, saturated with flame, heat and moisture-resisting compound.
Outer Covering: Asbestos braid, saturated ana finished
with flame, heat and moisture-resisting compound (standard color--black).
(a) Wall of felted asbestos, saturated with flame, heat and moisture-resisting compound.
NOTE: Both types also available with flame and heat-resisting finish {standard color--white).
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength............................................... Reler to page 31 Resistance to Flame.............................................................Refer to page 32 Dielectric Strength--following Flame Test. . . . Refer to page 32 Dielectric Strength--curing Immersion .... Refer to page 32
REVISED
PAGE 16
Jan., 1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPOPA^N
CAMBRIC INSULATED WIRES AND CABLES
Coiolog 37
qQ 02931
\ J
CONDUCTORS
Sis* C.M. or
A.W.G.
Construction
INSULATION THICKNESS Minimum Average
- -
First Varnished Second
Diameter Asbestos Cambric Asbestos
Inches
Mils
Mils
Mils
Asbestos _
,, Weight
Braid Overall
per
Thickness Diameter ICOOFt.
Mils
incnes Ne: Los
STANDARD PACKAGES
Fee:
Weight per
ICOO Ft. Gross Los.
Dieiectri: Test
Voltage Volts
ALL-ASBESTOS INSULATED
SOO.OOO <50,000 <00.000 1S0.000 300.000
427 x .0342" <27 x .0325427 x .0306" 427 x .0286" 427 x .0265"
2S0.003 </0 3/0 2/0 1/0
427 x .0242" 2S9 x .0286" 259 x .0255" 259 x .022?" 259 x .0202"
.923 .878 826 .772 .716
.653 .600 .536 .477 .424
90 90 90 90 90
90 75 75 75 75
45
1.195
1919
500 (Reel)
2321
1SCC
45
1.150
1775
SCO (Reel -
*: /1
isce
45
1.100
1589
SCO (Reel
1915
1 soc
45
1.045
1412
500 IReel'
, ?<;
1500
45
.990
1233
500 (Reel-
15c?
ISX
45
.925
1053
1000 (Reel;
1383
1500
45
.840
884
1000 (Reel'
1085
ISOO
45
.780 721 ICOO (Reel;
366
1SCC
45
,720
S93 1000 (Reel)
758
ISOO
45
.665
488 1000 (Reel1
653 ISOO
ALL
ASBESTOS and ASBESTOS VARNISHE. CAMBRIC APPARATU and MOTOR LEAD
2S9 x .0)80"
.378
2
133 x .0223"
.336
3
133 x .0199"
.299
133 x .0177"
.266
5
133 x .0153"
.237
75 60 60 60 60
6
133 x .0140"
.212
60
8
133 x .0111"
.168
40
10 104 x .010"
.120
40
12
65 x .010"
.MS
- 40
14
41 x .010"
.075
30
CABLES45
.620
405 1000 (Reel)
570 1500
45
.550
290 1000 (Reel)
390 1500
Types AI45
.510
240
ICOO (Reel!
340 ISOO
45
.480
203 1000 (Reel)
303 1500
45
.450
166 1000 (Reel)
266 1S00
and AVA
45
.425
140
ICOO (Reel) ..
240
1SC0
600 Volts4$
.340
92 500 (Coil)
95 1500
45
.290
65 500 (Coil)
68 ISOO
45
.265
49 ICOO (Coil)
52 1SCC
45
.225
44 1000 (Coil)
47 1500
16
26 x .010"
.059
30
18
16 x .0)0"
.045
30
45
.210
38 1000 (Coil)
41 1500
45
.195
33 1000 (Coil)
36 1S0C
ASBESTOS-VARNISHED CAMBRIC INSULATED
1.000.000 427 x .0484"
1.295
30
40
40
45
1.605
3719
SCO (Reel)
900.000 427 x .0459"
1.222
30
40
40
45
1.S35
3373
500 (Reel)
800.000 427 x .0433"
1.153
30
40
40
45
1.465
3038
SCO (Reel)
7SO.OOO 427 x .0414"
1.134
30
40
40
45
1.445
2865
SCO IReel)
700.000 427 x .0405"
1.088
30
40
40
45
1.400
2693
SCO (Reel)
600.000 427 x .0395"
1.027
30
40
40
45
1.340
2330
SCO (Reel)
SOO.OOO 42? x .0342"
.923
2S
40
40
45
1.22S
1953
500 (Reel)
450.000 427 x .0325"
.878
25
40
40
45
1.180
1781
500 (Reel)
400.000 42? x .0305"
.826
25
40
40
45
1.130
1601
500 (Reel)
350.000 427 x .0286"
.772
25
40
40
45
1.075
1417
SCO (Reel)
300.000 427 x .0265"
.716
25
40
40
45
1.020
1244
S00 (Reel)
2SO.OOO 427 x .0242"
.653
2S
40
40
45
955
1064
500 (Reel)
4/0 259 x .0285" .600
20
30
30
45 .850 884 1000 (Reel)
3/0 259 x .0255" .S36
20
30
30
45
.785
726 ICOO (Reel)
2/0
259 x 0227"
.477
20
30
30
45
.730
S93 1000 (Reel)
1/0 259 x .0202" 424
20
30
30
45
.67S
490 1000 (Reel)
1
259 x .0180"
.378
20
30
30
45
.630
406 1000 (Reel)
2
133 x .0223"
.335
15
30
20
45
560 318 1000 (Reel)
3
133 x 0199"
.299
IS
30
20
45
.520
264 1CCO (Reel>
4
133 x .0177"
.266
IS
30
20
45
490
225 ICOO (Reel)
S
133 x .0158"
.237
15
30
20
45
.460
185 ICOO (Reel!
133 x 0140"
.212
15
30
20
45
.435
1S8 1000 (Reel'
8
133 x .0111"
.168
10
30
IS
45 .370 104 500 (Coil)
10 104 x .010"
.120
10
30
15
45
.320
76 500 'Coil)
12 65 x 010" .095 1C
33
15
45 296 S9 1CC0 tCoil)
14 41 x 010" .075 10
16 26 x 010" .059 10
18
16 x .010"
.045
10
30 30 30
15
45
.275
45 ICOO (Coil!
15
45
.260
38 ICOO (Coil!
15
45
.245
32 10X tCoil.
Suoiest tc - 552 loloranae m overall dimensions. The above dalo are opproximoie and subiect lo normal manufacturing tolerances.
4119 3773 3438 3263 3093
2730 2353 2021 1841 1657
1484 1304 1084 S4S
713
610 506 <:s 364 325
2S2 255 1C7
79 62
48 41 nx
4COO 4000 4000 4CC0 4000
4COO 4000 4000 40CO 4000
4CC0 4000 3000 3CC0 3CCC
3CCC 3000 3000 3000 3000
3000 3000 2SCO 2500 2SCO
2SCO 2500 25X
.
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED
revised
CAMBRIC INSULATED WIRES AND CABLES 's^7 PAGE 17
GC 02932
ALL ASBESTOS EXTRAFLEXIBLE MOTION PICTURE or ARC LAMP CABLES
Type AI 300 Volts
Recommended for the wiring of motion picture projectors, searchlights, floodlights, spot lights, stage lights, electric cranes, controllers or other similar apparatus sub
ject to exceptionally high temperatures, where a wire or cable of extreme flexibility is required and operating potentials do not exceed 300 volts.
CONSTRUCTION
Refer to pages 30 and 31':
Conductors:
.
Extra-flexible stranded conductors of soft annealed copper.
Insulation:
Wall of felted asbestos, saturated with flame and heat-resisting compound.
Outer Covering: Asbestos braid, saturated and finished
with flame and heat-resisting compound (standard color--white).
NOTE: Also available with moistureresisting saturation and finish.
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength................................................Refer to page 31 Resistance to Flame............................................................. Refer to page 32 Dielectric Strength--following Flame Test.... Refer to page 32
revised
PAGE 18
Jun.. 1942
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
Nominal Sis
A.W.G.
Construction
Diameter Inches
Asbestos Insulotion Thickness Minimum Ave rage
Miis
Asbestos Braid
Thickness Mils
Overall Diameter
Inches
Weight per
10CC Ft. Net Lbs.
STANDARD PACKAGES
Weight per 1000 ft. ' Gross
Lbs.
Dielectric Test
Voltoge Volts
4/0 3/0 2/0 1/0
8464 x -36 6713 x .'36 5292 x f36 4214 x 436 3332 x .36
.620 .555 .490 44C .360
6C 6C 60 60 60
45
.630
847
iso (Coin
45 765 690
'.50 (Coil'
45
.700
ex- - 150 (Coil'
45
.650
465
200 (Coil)
45
.570
372
200 (Ceil)
860 10X 70S 100C 565 icoc 480 1000 385 1000
2
2646 x *36
.325
40
4
1666 x *36
.255
40
6
1050 x *36
.205
40
8
661 x .36
.165
30
10
413 x -36
.130
30
45
.495
233
45
.425
195
45
.375
135
45 .315
94
45 .267
75
200 (Coil) 2S0 fCc.il> 500 (Coil1 500 iCoi!' 500 (Co.;
30C 210 ISO
99 73
10-00 100-0 1000 iCOO ioc:
12 259 x -36 102 30 45 .255 S3 10-00 <Co.r.
14
105 x *34
.077
30
45 .230
44
1000 (Co:!-
16
65 x -34
.06!
3:
45 .215 37 i:o; (Co.:-
18
41 x -34
.047
j"
45 .205
rr
:::c iCc;;
* s-jb'ef. -o - S'vc tolerance n overall d mens.or.; Tne ocove ac:c ere accrcs. rote and susjec: t; nor.-tit n-.cnuta: urine tolerance.'
58 lo-o: 47 oo* 40 io:; 36 1007
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
CAMBRIC INSULATED WIRES AND CABLES
Calolo, 37
GC 02933
Recommended for wiring of switchboards and all other types of control apparatus, where the operating temperature does not exceed 90C. The basic Gencaseal insu lation is a solid wall of synthetic compound,
impervious to moisture, oil, acid or similar solutions and therefore provides a main tained high dielectric strength under all conditions ot operation. Approved by the Underwriters' Laboratories as Type SNA.
CONSTRUCTION
(Refer to page! 30 and 31'
Conductors: Solid or stranded conductors of tinned,
soft annealed copper.
Insulation: (a) Wall of Gencaseal compound, so ap
plied as to allow removal by commercial stripping machines. Can be supplied with a separator under the insulation, to
provide exceptional free-stripping proper ties and
(b) Wall of felted asbestos, saturated with flame, heat and moisture-resisting compound.
Outer Covering: Cotton braid with a flame and heat-
resisting finish (standard- color--gray).
GENCASEALASBESTO SWITCH BOARD/ WIRES
Type SNA 600 Volts
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength............................................... Refer to page 31 Resistance to Flame.............................................................Refer to page 32 Dielectric Failure.............................................................Refer to page 33 Leakage Resistance.............................................................Refer to page 33 Bend--Dielectric .............................................................Refer to page 33
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
A.W.G
CONDUCTORS
Construction Diameter Inches
THICKNESS Minimum Average
Gencaseal Asbestos
Compound
Miis
Cotton Braid Thickness Mils
%
Overall Dicrr.eter
4 0 Soiid 3 0 Sons
2'C Soho 1 <0 Solid
l Solid
.460 .412 .365 .325
43 40 40 40 40
2 Solid .25e
3 Solid
225
4
Soiia -
.204
S Solid .182
6 Solid .162
30 33 30 30 30
8
Soho
.128
Sol.d
Ob
12 Soi-.c .081 Soho
SctiG
.051
28
Souc
.040
20 20 20 20 20 20
4 '0 30 20
!
2 3
6
19 x .ICS?" !? x .0940"
19 x .0664
7 x 0974" ? X .086?" ? x .07. -
x 05oc ? x 06.:"
.S2S .470 .419 .373 .332
.292 .26C
.206 .184
40 40 40 40 43
33 33 32 30
8 7 x 0486' 146
10
? x .038:"
115
X . .092
]4
X .'J/i,
,C/2
2$ -
18
74:
rl
jT 2'
Su.ve *> JO " t^ :oi*rar "<? \r. ove 3)1 c;mens:c
40 4C 4C 40 43
33
30 30 33
20 20 20
23 23
40 43 4? a2 43
23
n c
V' '*
2- 66? IS 60s 8 56C tc 52: 18 4S5
16 /.: ^ 16 .383 16 .363 c 16 .315
16 257 * <5
Sc 16
;6> 16
-'.S ccf iC e:s
2 :e 5."
18 .x? ;e A -1 !c 3c5 ;x :C.
it
:6 0z
.c
r ~* .6 .5:
Weight per
1000 Ft. Net Lbs.
759 615 SOI 409 336
259 204 173 141 117
67 46 32 23 18 14
636 -2" 426 OAr
269 ": 183 \A.
' c. 14
STANDARD PACKAGES Dieiectr Test
Feet
per lOOOFt. Gross Lbs.
Volts
503 (Reel) 500 (Reel: 500 (Reel) S00 (Reel-
500 (Reel:
715 631 SO? 436
3037 3000 3000 303-0 3000
S00 (Reel) S00 (Reel) 500 (Reel) 500 (Coil) 500 (Coilj
359 304 270
120
3003 303? 3C03
3377
500 (Coil) 73 30-00
S00 (Coil: 49 3000
500 (Coil' 35 303?
500 (Coil) 25 3007
1300 (Cos!'
21
30C7
1003 (Coil' 17 303?
500 (Reel) 500 (Reel' 503 (Reel* 500 (Reel) 503 (Reel
865 738
627 S26 449
3000 3-003 3007
30?:
533 (Reel1
500 (Reel' 530 (Co;:500 (Coil'
533 fOoi j " 577 (Co,.
537 iCo-.o
232 'Co:;'
369 321 262
'.22 7;
ng
;"
3??: so?: 3?:: V'-'* so?:
??::
307'
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
REVISED
PAGE 19
ASBESTOS-
VARNISHED
CAMBRIC SWITCH
Recommended for wiring switchboards and all other types of control apparatus. Will resist heat, flame, oil and corrosive
BOARD WIRES
vapors. Outer cotton braid especially de signed to accommodate sharp bends asso ciated with these types of installation. Ap
and
proved by Underwriters' Laboratories as
Type AVB. Maximum recommended operating tem
perature is 90C. For wiring of boards where temperatures exceed this limit, the use of All-Asbestos Rheostat Wire (refer to page 14) is recommended.
CABLES
Type AVB 600 Volts
CONSTRUCTION
{Refer to pages 30 and 31)
Conductors:
Solid or coarse stranded conductors of tinned, soft annealed copper.
(b) Wall of felted asbestos, saturated with flame, heat and moisture-resistmg com pound.
Insulation:
(a) Wall of varnished cloth tapes applied as a series of helical wraps.
Outer Covering: Cotton braid with a flame and heat-
resisting finish (standard color--gray).
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength................................................Refer to page 31
Resistance to Flame ...................................
... Refer to page 32
Dielectric Failure............................................................. Refer to page 33
Leakage Resistance............................................................. Refer to page 33
Bend--Dielectric ............................................................. RefeT to page 33
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
Six* A.W.G.
Construction
__
Diameter Inches
INSULATION THICKNESS Minimum Average
Varnished Cambric
Mils
Asbestos M,u
4/0 3/0 2/0 1/0
1
Solid
Solid
Solid Solid Soiid
.460 .410 .365 .325 .289
40 40 40 40
40
40 40
40 40 40
2 Solid
4 Solid
6 Solid e Solid 10 Solid
.258 .204 .162 .128 .102
40 40 40 30 30
30 30 30 20 20
12 Solid 14 Solid 16 Solid 18 Solid
.081 .064 .0S1 .040
30 30 30 30
20 20 20 20
4/0 19 x .1055" 3/0 19 x .0940" 2/0 19 x .0837" 1/0 19 x .074S"
1 19 x .0664"
.S28 .470
.4ie .373 .332
40 40 40 40 <0
40 40 40 40 40
2
7 x .0974"
.292
4
7 x .0772"
.232
6 7 x .0612" .184
8 7 x .0486" .146
10 7 x .0385" .116
40 40 40 30 30
30 30 30 20 20
12 7 i .0305" .092
14
7 x .0242"
.073
16
7 x .0193"
.058
18 7 x .0151" .045
30 30 30
30
20 20 20 20
Colton Braid Thickness Mils
Overall Diameter
Inches
_______ .
____
20 .665 20 .61S 20 .S70 20 .530 20 .495
20 ' ` .440 17 .380 17 .340 17 .265 17 .240
16 .215 16 .200 16 .185 16 .175
20 .735 20 .675 20 62S
20 .580 20 .540
20 .475
20 .415 17 .360 17 .285 17 .25$
16 225 16 .205 16 .190 16 .180
Weight per
1000 Ft. Net Lbs.
800 650 S30 435 365
300 210 155
74 52
38 28 22 17
83S 675 S55 460 380
315 225 163
77 55
40 30 23 18
STANDARD PACKAGES
Fee: .. .. ________
Weight per 1000 Ft. Gross Lbs.
Dielectric Test
Voltage Volts
500 (Reel? 500 (Reel?
500 (Reel) 500 (Reel? 1000 (Reel)
900 750 630
535 46S
4000 4000 4000
4000 4000
1000 (Reel) 1000 (Reel) 1000 (Reel?
500 (Coil) 500 (Coil)
400 310 255
77 55
4000 4000 4000 2500 2500
500 (Coil) 500 (Coil) 1000 (Coil) 1000 (Coil)
41 2500 31 2500
25 2000 20 2000
500 (Reel) 500 (Reel)
500 (Reel) 500 (Reel) 1000 (Reeb
985 825 655 S60 480
4000 4000 4000 4000
4000
1000 (Reel) 1000 (Reel) 1000 (Reel,
500 (Coil500 (Coii:
415 325 263
80 56
4000 4002 4000 2503 2500
500 (Coil: 500 (Co:!. 1000 (Co,;1000 (Coil
43 2500 33 2500 26 2000 2i 2000
The aoove dots are approximate ond subiec: :c normal mor.,i!a:tu.'ing tolerances.
revised
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
PAGE 20
CAMBRIC INSULATED WIRES AND CABLES
1942
\)<!/
Catalog 37
GC 02935
Recommended lor wiring of switchboards
Maximum recommended operating tem
and all other types of control apparatus
perature is 90C. Approved by Under
where a coarse stranded conductor is de
writers' Laboratories as Type AVB.
sired and an overall cotton braid is per
missible.
CONSTRUCTION
(Refer to pages 30 and 31'
Conductors: Coarse stranded conductors of soft an
nealed copper.
Insulation: (a) Wall of felted asbestos, saturated with
flame, heat and moisture-resisting com pound.
(b) Wall of varnished cloth tapes applied as a series of helical wraps.
(c) Wall of felted asbestos, saturated with flame, heat and moisture-resisting com pound.
Outer Covering:
Cotton braid with a flame and heatresisting finish (standard color--gray).
ASBESTO varnish: CAMBRIC SWITCH BOARD BUS CABLES
Type AVB 600 Volts
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
INSULATION THICKNESS Mintinw. Average
Six* C.M. or
A.W.G.
Diameter First Vormshed Second
Construction Inches Asbestos Combric Asoestos
Mils
Mils
Mils
1.000.000 900.000 800.000 750.000 700.000
61 x .1280" 61 x .1215" 61 x .1145" 51 x .IK" 61 x .1071"
1.152 1.094 1.03:
.998 .964
30 30 X X 30
40 40 40 40 40
40 40 40 40 40
Cotton
Thick ness Mils
26 26 26 26 2c
Overall Weight Diameter per
Inches 1000 Ft. Net Lbs.
STANDARD PACKAGES
Feet
Wt. per
lOCOft. Gross Lbs.
435 1.375 1.315 1.280 1.245
3524 3190 2856 2695 2522
500 (Reel' 500 (ReelSCO (Reel,1 500 (Reel) SCO (Reel)
3924 3590 3256 3095 2922
Dielectric Test
Voltage Voits
400C 4000 4COO 4CC0 4CCC
650.000 61 x .1032"
.929
X
40
40
26
1.210
2355
SCO (Reel)
27S5
4CC0
600.000 61 x .0992"
.893
30
40
40
26
1.175
2188
SCO (Reel)
2428
4000
550.000 61 x 0950"
.855
X
40
40
26
1.135
2021
500 (Reel '
226!
4CCO
500.000 37 x . 1162"
S'. 2 25
40
40
26
1.085
1779
500 (Reel!
2019
4000
450.000 37 x .1102"
772 2S
40
40
26
1.04$
1614
500 (Reel)
1854
4COO
400.000 37 x .1040"
.725
25
40
40
26
1.000
1451
SCO (Reel)
1691
4CCC
350.000 37 x .0973"
.681
25
40
40
26
.9S5
1281
500 (Reel)
1521
4000
300.000 37 x .0900"
.630
25
40
40
26
.900
1119
SCO (Reel)
1316
4COO
850.000 37 x .0822"
.57$
25
40
40
20
.845
926
SCO (Reel)
1152
4CC0
4/0
19 x .1253"
,S2S
20
30
30
20
.735 820 10CO (Reel)
940
3000
3/0 19 x .0940" 470 20
30
30
20
.675 67C 1000 (Reel)
790 3000
2/0
19 x .0937"
.419
20
30
30
20
.625
556 10X (Reel)
675
3000
1/0
IS x 0745"
.373
20
30
30
20 .580 455 1000 (Reel) 555 3000
1 IS x .0664" 332 20
30
30
20
.540
350 1000 (Reel)
450
3000
2
7 x 0974"
.292
IS
30
20
7
4?C 265 1CC0 (Reel)
366 3oo:
3
7 x 0567"
.260
15
X
20
: .433
1000 (Reel)
317 3000
4
7 x .0772"
.232
IS
30
;7
.405
i/9 1CCO (Reel)
279 3COO
s
7 x 0688"
.206
15
30
i? 330 is: 1000 (Reel; 250 3000
6
7 x .0612"
.164
15
30
77
!7
.355
125 1000 (Reel)
225
3000
8
7 x .0486"
.146
10
X
15
.300
S3 SCO (Coil;
86 2SCC
10
7 x 0385"
.116
1C
3C
15
.2SC
12
7 x .0305"
.092
10
30
lJ
17
14
7 x .0242"
.073
i:
30
15
16 .221
16
7 x .0192"
CSr i:
30
13
\f .205
16
7 x .01 SC"
.043
i:
30
lv
\i
S-cer: tc r 5'~ tc5er d:*. re :r. overall c:rp*;r.sicr.c
Tne cccve acts ore opprax:rr.G te ana ter er r.or rrc: mane:
6; SCO (Coil; ni 10X (Co:!) r_ 1000 (Co-"
1CCO (Co-! '.9 1000 'Co.U
rcterartges
6C 2SCC 4$ 25CC 34 2SCO 26 2500 22 2502
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
GC 02936
REVISED
PAGE 21
1942
GENCASEALASBESTOS HINGE CABLES
Type SNA 600 Volts
Recommended for swinging panel con nections and other general panel work where an extra-flexible construction is re quired, and the operating temperature does
not exceed 90C. This construction is com parable to Gencaseal-asbestos switchboard wire. Approved by Underwriters' Labora tories as Type SNA.
CONSTRUCTION
(Refer to pages 30 and 31)
Conductors:
Flexible stranded conductors of tinned, soft annealed copper.
(b) Wall of felted asbestos, saturated with flame, heat and moisture-resisting compound.
Insulation:
(a) Wall of Gencaseal compound, so ap plied as to allow removal by commercial stripping machines.
Outer Covering:
Cotton braid with a flame, heat and
moisture-resisting finish (standard color--
gray).
~
RTVISED
PAGE 22
Juft., 1942
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength................................................Refer to page 31 Resistance to Flame............................................................. Refer to page 32 Dielectric Failure............................................................. Refer to page 33 Leakage Resistance.............................................................Refer to page 33 Bend--Dielectric.................................................................... Refer to page 33
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
INSULATION THICKNESS Minimum A veroge
Six* A.W.G.
Construction
Diameter Inches
Gencaseo! Compound
Mils
Felted
Asbestos Mils
Cotton Braid Thick ness
Mils
Overall Diameter
inches
. weight
per 1000 Ft. Net Lbs
STANDARD PACKAGES
. Feet
Wt. per
1000 Ft Gross lbs.
Dielectric Test
Voltage Volts
4/0 3/0 2/0 1/0
2 3
S 6
8 10 12 14 16 18
259 x .0286" 259 x .0255" 259 x .0227" 259 x .0202" 259 x .0)80"
133 x .0223" 133 x .0199" 133 x .0177" 133 x .0158" 133 x .0140"
133 x .0111" 104 x .010"
65 x .010" 41 x 010" 26 x .010" 16 i .010"
.600 .536 .477 .424 .378
.336 .299 .266 .237 .212
.168 .120 .095 075 .059 .045
40 40 40 40 40
30 30 30 30 30
:: 20 o: 07 :: ::
40
22
.805
843
S00 (Reel)
1008
3000
40
22
.740
683
S00 (Reel)
848
3000
40
22 .680 SS8 500 (Reel: 723
3000
40
18 .620 457 500 (Reel' 622
3000
40
18
.575
377
S00 (Reel)
542
3000
30
18 .495 289 500 (Reel' 389
3000
30
13 4S5 237 500 (Reel' 337
3000
30!
16
.420
196
500 (Reel
296
3000
30
16 .390 164 $00 (Reel
264
3000
30
16 .365 132 500 (Reel'
135
3000
20
16 .285
83 500 (Coil!
86 3000
20
16 .235
58 500 iCoil'
61
3000
16 .210
41 S00 Co.l'
44 3000
20
16 .190
31 S00 iCoil
34 3000
12
16 .175
25 1030 (Co;!.
23 3000
22
16 160 20 1000 'Cc.l
^ *2 3009
* Subiec ta
tolerance in over a!! dimer.s.or.s Tne ooove = s:a are accra x:rr.
c r.s sue ect io norma; m artuiaciuring tolerances
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
CAMBRIC INSULATED WIRES AND CABLES
Catalog 37
02937
Recommended for swinging panei con nections and other general panel work where an extra-flexible construction is re quired. Approved by Underwriters' Labo
ratories as Type AVE. Maximum recommended operating tem
perature is 90C.
ASBESTOS VARNISHE CAMBRIC HINGET CABLES
CONSTRUCTION
(Refer to pages 30 and 31'
Conductors:
Flexible stranded conductors of tinned, soft annealed copper.
(c) Wall of felted asbestos, saturated with flame, heat and moisture-resisting com pound.
Type AVB 600 Volts
Insulation:
(a) Wall of felted asbestos, saturated with flame and heat-resisting compound.
(b) Wall of varnished cloth tapes applied as a series of helical wraps.
Outer Covering:
Cotton braid with a flame and heat resisting finish (standard color--gray).
PERFORMANCE CHARACTERISTICS
Initial Dielectric Strength............................................... Refer to page 31 Resistance to Flame.............................................................Refer to page 32 Dielectric Failure.............................................................Refer to page 33 Leakage Resistance.............................................................Refer to page 33
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
INSULATION THICKNESS Minimum Average
Six* A.W.G.
Construction
Diameter First Varnished Second
Inches Asbestos Cambric Asbestos
Mils
Mils
Mils
Cotton Braid Thick ness Mils
* Overall Weight Diameter per Inches 1CC0 Ft.
Net Lbs.
STANDARD PACKAGES
' "" -
' Wt.lir
1090 Ft. Gross
Lbs.
Dielectric Test
Voltage Volts
8 133 x .011" .168
10 104 x .010" .120
12
6S x 010"
.03$
14
41 x .010"
.075
16
26 x .010"
.0S9
18
16 x .010"
.045
10 10 10 1C 10 10
32 30 30 30 30 3:
15
17
.315
84
SCO (Coil)
87
300
15
17
.265
56
5C0 :Cot!)
6:
300
15
16
.240
43
500
46 300
15
16
.220
32
50) (Coil!
3S
300
15
16
.205
25
100 (Coil;
28
3000
15
16 .190 19 ioc (Coin 22
300
* Surif:'. to ; 5' c toieronce in overall dimensions The obove data or approximate and subject to normal manufacturing tolerances.
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
GC 02938
revised
PAGE 23
ALL
ASBESTOS APPLIANCE LEAD WIRES (RANGE WIRES)
Type AI 300 Volts
Recommended ior wiring or small port able electric appliances such as waffle irons, hot plates, grills, stoves, Hat irons, toasters, percolators, etc., as well .as small motors, water heaters, small switchboards, battery control panels, blue print machines and radio and medical apparatus, particu larly where severe heat conditions exist. Can be supplied with either copper, monel or nickel conductors.
Available in two types: (a) Heat-resist ing--having a special high temperature saturant. which is also especially flameresisting, but not suitable where moisture hazards exist, and
ue.
(b) Moisture-resisting--having c mois ture and heat-resisting impregnant of a character which is somewhat more sus ceptible to smoking at elevated tempera tures. Both types available in either black, white, red or green colors--with other colors on special order.
Also available in three conductor twisted form, for use on all heating devices and appliances using a three-heat switch tor controlling current flow.
Maximum recommended operating tem peratures:
Where no moisture is present . 200C. Where moisture is present . . . 125C.
CONSTRUCTION
(Refer to page* 30 and 311
Conductors:
Solid, coarse or flexible stranded conduc tors of soft annealed copper.
ture-resisting compound (standard colors-- black or white) or with alternate color fin ishes as specified by the purchaser.
Insulation:
Wall of felted asbestos, saturated with flame and heat-resisting compound (stand ard color--white) or flame, heat and mois
Cable Assembly:
Also available as a three conductor assembly of three single conductor types, as outlined above, assembled by twisting.
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
Si A.W.C.
CONDUCTORS
DiometeInch?-
Asbestos Insulation Thickness Minimum Averaoe
Overall Diameter
--
.....
Weiaht per 1000 Ft.
Single Cor.c. Inches
Three Cond. inches
pinole Three Cond. Cond.
Net Net Lbs
STANDARD PACKAGES
Sinale Condudor . .. Wi. per 100C Ft
Lbs.
Three Conductor
_ Fee:
per 1030 FGross
Lcs
8
Solid
.126 40 .21C
70
1000 (Coil'
73
ioo:
10
Sc!::
.102 40 .165
49
1000 (Coil1
52
ix:
12
Soi.c
.os:
4?
.165
.350
34 105 1000 (Coil1 37 ioo: -Cot': (75
1
14
Soho
.064
30
.125
.270
o:
64 1000 (Coil! 24 1000 'Coil
67
1000
16 Solid
30
.:: s
.240
15
46 1000 (Coil* 16 1009-.CmI'
4?
10X
17
Solid
.045
30
.105
.230
13
40 looo (Coil; 16 1090 (Coil' 4 3
1X0
18
Soi.d
047
30
.100
.220
11
35 1000 ICoiV' 14 1000 (Coih
3c
1 Vl*'
20
Solid
.030
3C
095 .200
9
27 1000 (Coil)
12 1000 (Coil'
30
! 000
10 7 x 0385" i:e
4:
210 405 * 15S I00C (Co.lt 54 1000 'Co.i. 155 1007
12
7 x .0305"
r.0`
4?
|
370 36 110 10C0 (Co'U 3S looo Co-.'.'
1X0
U
7 x 0242"
.0.-3
30
.135
.290
67 looo (Coil; 25 looo Go.;-
1X7
16
0 r O! 0"*"
OSS
3:
i
.255
!_
49 1000 'Co.!
15 1000 Co.:
52
100*
18
7 x .0152"
.045
30
105
.230
10
37 1CO0 (Coil
15 ICOOCoil.
47
1007
8
165 x *30
.IS:
40
233
sc:
62
20c 1900 iCoil:
71
1000 (Coil. 210
1X0
10
1C5x -37
. * X.
40
.435
46 140 1000 (Coil: 49 1000 :Co: 144
10X
12
65 x -37
095
4'
*"e .387 "
ST 1000 (Coil' 25 ix* -Coi:- :ot
100C
M
41 x -30
0. 5
30
.135
.29-0
A-
67 1000 (Coil
23 iOOO-Co.!'
77
10X
16
26 x -37
05?
.267 16 4? 1CCC
1? 1002 Cc.t
52
ioo:
17 20 x -30
* ( 2
14
40 1002 (Coil: J ? 1000 iCo7
45
iox
18 16 x
.04:
V
;
;-
36 :xo (Cow L5 :oo: iCo:'.
35
I0X
20
io -o:
.03:
3"
: or .210
9 26 ) QCO (Got) - 12 !202 'Co.' 3)
1X0
$.:r-er! tc z 50 tolerance :r r-.-e.-al: cirr.e.-.sicr:T-.e crave ac-.i ore oocrox n.o-.e or.c S'jcie:: to r.crrr.o: mar.uiccuirins loieror.ces
REVISED
PAGE 24
J uni . 1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
GC 02939
mmaammmuammum'
ALL ASBESTOS
Recommended for the wirinq of electric
and is therefore applicable to similar ap ELECTRIC
STOVE-it
ranges, space heaters, electric water
plications where moderate moisture hcz-
heaters, bake ovens, cookers, hot plates anc similar apparatus. Available with
arcs are encountered. However, at ele
WIRESvated temperatures these impregnating
either copper, nickel or monel conductors.
Available m two finishes. Recommended type dependent upon moisture hazards.
Type AIcompounds are subject to some smoking.
Maximum recommended operating temper
ature is 125C. (if moisture is present).
300 Volts
The heat-resistinc type is preferably used where heat conditions are severe, but little or no moisture is encountered. Maximum recommended operating temperature is 200C.
The moisture-resisting type is treated with moisture and heat-resisting compounds
NOTE: Stove wires are considered to have a materially higher abrasion re sistance than range wires and are there fore recommended for use when subject to intermittent flexure as in armored leads between grids of domestic appli ances.
CONSTRUCTION
(Refer to page* 30 and 31'
Conductors: Solid or coarse stranded conductors of
soft annealed copper.
Insulation: Wall of felted asbestos, saturated with
either a flame and heat-resisting compound or a flame, heat and moisture-resisting
compound as specified by the purchaser.
Outer Covering: Asbestos braid saturated and finished
with either a flame and heat-resisting com pound (standard color--white) or a flame, heat and moisture-resisting compound (standard color--black) or with alternate color finishes as specified by the purchaser.
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
SlZ A.W.G.
4 6 8 10
12 14 16 18
4/0 3'0 20 10
1
2 3 4 s 6
8 10 12 14 16 18
CONDUCTORS
Oons* ' * *
Solid Sell'S Soiic Solid
Solid SoiiC Solid Solid
19 .1035' 19 x .0940" 19 x 0S37" 19 x .C745" 19 x 0664"
7 x 097<" 7 x 0867" 7 x 0772" 7 x .0588" 7 x 0612"
7 x 0486"
7 x 7353"
7 x .0302" 7 x 0.'47" 7 r C. 92 7 x 3133"
Diameter incnes
Asbestos Insulctior. Thickness Miriitri-jm Averooe
Mils
Asbestos Braid
Thickness
.
Overci: D.QTrieter
lncr.es
.204 .162 .128 ,!02
.GS1 064 .051 040
528 470 .419 373 '22
2C3 .260 .232 206 .164
146 '6
097 073 056 045
40 401 3C 3C
30 30 30 30
60 60 60
ec
63
4' 43 40 40 40
30 30 37 3: 3? 37
45 .375
Al .375 <5 2s: 45 .255
45 235 45 2' z 45 205 45 ; c*
4455
45
7^-
64 3y'
4f 55:
45 34;
4r ' 4f 4 y
4?
4f 3?
<-
4 f E" *
4; *4*
24 ~ EE:
47 , *
:**.
Weigh: per
1000 Ft Net Lbs.
177 124 89 6?
33 43 37 33
807 632 643 44's/ 362
2-.735-
1 55! 2i
9: 6? 54 44 35
STANDARD PACKAGES
tee.
Wetort:
Per 100: F: Gross Lcs
Dielect.-i Test
Volioge Volts
S0C rCoil' 500 -Coi! 500 Cml 50\_ iCoii
500 'Con 500 'Coil 500 Cot1 500 ;Coi.
1000 'Re*: 100C Reel ;00: tree' 1007 'Reei 1000 -Reei
1003 'Reel .'000 'Reel 1000 :Re* 1007 -Ree'
503 Cc.:
500 -Cc:! 500 Cc-! 500 ;Co.: 200 Ccii
507 tCs.:
21. 1000 j " 1003 9: 1000 72 1030
5c 1000 46 100c 40 1000 c 100:
9C? 1000 75J 1000 64 5 100: 54C I0OC 4cE !COO
57c l~y 5 : iooo
2S3 1023.
2:1 ] oo*'
5 3: 100:
9: "E ibof 57 100. 47 1 n'-; 4. 10' ` 35
S-: : = to.erarce - oxera.r d.r-.e.-.f.tr.' Ti-.c oro-.e co: = are necrox - c:* cr ; . - - , r:-
ittg iotercnee
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
Cotclcg 2?
XL#
revised
PAGE 25
Jun, 19-42
GC 02940
ASBESTOS-
VARNISHED
CAMBRIC
CONTROL
CABLES 600 Volts
For control wiring in boiler rooms, power stations, and other locations where subject to temperatures beyond the limits of other standard insulations.
Maximum recommended operating ternperature is 100C.
CONSTRUCTION
(Refer to page* 30 and 311
Conductors:
Flexible stranded conductors of either size 9 or 12 A.W.G. (nominal size) tinned, soft annealed copper.
Insulation:
(a) Wall of felted asbestos, saturated with flame, heat and moisture-resisting com pound.
(b) Wall of standard varnished cloth tapes applied as a series of helical wraps.
(c) Wall of felted asbestos, saturated with flame, heat and moisture-resisting com pound.
Covering:
Dry cotton braid, color-coded for ready conductor identification.
Assembly: _
(Multi-conductor) Required number of insulated and braid covered conductors are assembled by twisting.
Outer Coverings:
(Multi-conductor) Tape and asbestos braid, saturated and finished with flame, heat and moisture-resisting compound (standard color--black).
STANDARD NEMA COLOR SCHEME FOR CONTROL CABLES
ictor No.
1 2 3 4 5
6 1
e
e 10
n 12 13 14 IS
16 17 18 19
Bate Braid
Black White Red Green Orange
Blue White Red Green Orange
Blue Biacc Red Green Blue
Block White Orange Blue
Tracer
None None None None None
None Black Black Black Black
Block White White White White
Red Rec Red Red
revised
PAGE 26
19<2
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
Catalog 3?
GC 02941
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
ASBESTOS'
Nom
inal Sis* A.W.G.
CONDUCTORS
Number
Con
struc tion
INSULATION THICKNESS
Minimum Average
Cotton
Braid
Diameter Inches
First
Asoestos Mils
Var nished
Ccntunc Mils
Thick Second ness Asbestos Mils
Mils
Thickness of Overall
Coverings
Tope Mils
* per
Overall 1002 Diameter c-
Asbestos Inches Net
Braid
Lbs.
Mils
STANDARD PACKAGES
Feet
Dielectric
Wt.
pet 10CO
Test Voltage
Volts
_F:
Gross
Lrss.
9
1 19* *22 .127
10
30
15
45
.327
86 500 .Reel: 140
2002
9 2 19* 422
0 30 15 17 15 45 .665 229 SCO (Reel: 34? 2000
9
3 19 x #22 .127
10
30
15 17 15 45
.705 286 500 (Reel- 406 2020
9
4 19 x <22 .127
10
30
IS IT IS 45
.782 3S9 500 iReeli 4S7 2020
9
s 19 x *22 .127
10
30
15
17 15
45
.857 433 S00 (Reel! S6i
2000
9
6 19x/22 .127
10
30
15 17 IS 45
.933 526 SCO (Reel; 716 2000
VARNISHEI CAMBRIC CONTROL CABLES
600 Volts
9
7 19 x /22 .127
10
30
15 17 15 45
.938 561 SCO (Reel: 751
2020
9
8 19* #22 .127
ID
30
IS 17 IS 45 1.021 640 SCO (Reel' 830 2CC0
9
9 19* #22 .127
10
30
15 17 15 45 1.104 741 500 (Reel! 959 2000
9
10 19* #22 .127
10
30
IS
17 IS
45
1.209 823 500 (Reel* 1041
2000
9
11 19* #22 .127
10
30
15
17 15
45
1.209 883 500 (Reel: 1101
2000
9
12 19* #22 .127
10
30
IS
17 15
45
1.251 913 500 (Reel) 1131
2000
9
13 19* #22 .127
10
30
IS
17 15
4S
1.320 996 SCO (Reel) 1352
2COO
9
14 19* #22 .127 - 10
30
15
17 15
45
1.320 10S2 50C (Reel) 1413
2003
9
15 19* #22 .127
10
30
IS
17 15
45
1.358 1117 500 (Reel! 1483
2000
9
16 19* #22 .127
10
30
IS
17 IS
45
1.399 1200 500 (Reel) 1566
2000
9
17 19* #22 .127
10
30
15 !7 IS 45 1.480 1291 500 (Reel) 1657 2000
9
18 19* #22 .127
10
30
15
17 IS
45
1.480 1338 SCO (Reel) 1704
2000
9
19 19* #22 .127
10
30
15
17 15
45
1.480 1385 500 (Reel) 17S1
2020
12
1 19* *25 .090
10
30
15
45
.293
61 500 (Reel) 115 2000
12
2 19* <25 .090
10
30
15 15 15 45
.58!
162 SCO (Reel) 224
2000
12
3 19* #25 .cm
10
30
IS IS IS 45
.616 198 500 (Reel) 268
2003
12
4 19* #25 .cm
10
3D
15 15 15 45
.675 244 SCO (Reel) 364
2000
12
c 19* #25 .cm
1C
30
IS 15 15 45
.743 292 503 (Reel) 412
2030
12
6 19* #25 .cm
10
30
15 15 IS 45
.809 346 503 (Reel) 474 2000
12
7 19* #25 .cm
10
30
15 15 IS 4S
.809 366 SCO (Reel) 494 2003
12
8 19* #25 .090
10
30
15 IS 15 45
.878 4)6 SCO (Reel) 606 2CC0
12
9 19* #25 .090
10
30
15 15 15 4S
.94? 483 SOD (Reel) 673 2000
12
10 19* #25 .090
10
30
15 15 IS 45 1.036 535 SCO (Reel! 725 2030
12
li 19* #25 .090
10
30
IS IS IS 45 1.036 S72 500 (Reel) 762 2000
12
12 19* #25 .090
10
30
IS IS IS 45 1.071 583 500 (Reel) 806 2000
12
13 19* #25 .090
10
30
IS
15 IS
45
1.129 638 SCO (Reel) 8S6
2CC0
12
14 19* #2S .090
10
30
13 15 15 4S 1.129 678 500 (Reel) 896 2000
12
15 19 z #2S .090
50
30
15 15 IS 45 1.161 717 500 (Reel) 935 2000
12
16 !9*/2S .030
10
30
13
15 15
45
1 195 763 S00 (Reel: 981
2000
12
17 19* #25 .030
10
30
15 15 15 45 1 264 822 500 `Reel: 1040
12
IS 19* #25 .om
10
30
15 IS 15 45 1.264 849 SCO (Reel' 1067
12
19 19 x #25 .030
10
30
15 15 IS 45 1.264 876 SCO (Reel) 1C94
Subiect to
tolerance in overall dimensions.
NOTE' AIjo ovailabie with lead sheath in place oi standard braid finish (recommended for moist locations!.
Tne above data ore approximate and subiect to normal manufacturing tolerances
2000 2030 2CC0
GENERAL CABLE CORPORATION . , ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES rr --
Vis>>
GC 02942
revised
PAGE 27
-i..-. 1042
FLEXIBLE CORDS
300 and 600 Volts
HEADLIGHT WIRE -- Single Conductor -- Asbestos-Varnished Cambric and CAB CORD--Two Conductor --All-Asbestos (300 Volts) Light Duty
and Asbestos-Varnished Cambric (600 Volts) Heavy Duty
CONSTRUCTION
<Rfr to pa?** 30 and 3}1
SINGLE CONDUCTOR HEADLIGHT WIRE (600 Volts)
Conductors:
Flexible stranded tinned, soft annealed copper.
flame, heat and moisture-resisting com pound.
Insulation: (a) Wall of varnished cloth tapes applied
as a series of helical wraps. (b) Wall of felted asbestos, saturated with
Outer Covering: Cotton braid, saturated and finished with
flame, heat and moisture-resisting com pound (standard color--black).
TWO CONDUCTOR LIGHT DUTY CAB CORD (300 Volts)
Conductors: Flexible stranded conductors of soft an
nealed copper.
Assembly: Insulated conductors assembled by
twisting.
Insulation: Wall of felted asbestos, saturated with
flame, heat and moisture-resisting com pound.
Outer Covering: Asbestos braid, saturated and finished
with flame, heat and moisture-resisting compound (standard color--black).
TWO CONDUCTOR HEAVY DUTY CAB CORD (600 Volts)
Conductors:
flame, heat and moisture-resisting com
Flexible stranded conductors of tinned,
pound.
soft annealed copper.
Insulation: (o) Wall of felted asbestos, saturated
with flame, heat and moisture-resisting
Assembly: Insulated conductors are assembled by
twisting.
compound.
Outer Covering:
(b) Wall of varnished cloth tapes applied as a series of helical wraps.
(c) Wall of felted asbestos, saturated with
Asbestos braid, saturated and finished with flame, heat and moisture-resisting compound (standard color--black).
USE
Single Conductor Headlight Wire (600 Volts).
Two Conductor Heavy Duty Cab Cord (600 Volts).
For use as cab and gauge-light wiring on locomotives, and as extension cord m steel mills, kiln rooms, etc,
For use similar to Light Duty Cab Cord, but especially where there is exposure to oil, grease, moisture, etc.
Maximum recommended operating tem peratures:
Two Conductor Light Duty Cab Cord (300 Volts).
All-Asbestos Insulated, 200C. where no moisture ts present. Asbestos-Varnished Cambric Insulated--
For use as cab and gauge-light wiring on
(ICO--3 E)C. where E represents the
locomotives, and as extension cord in steel mills, kiln rooms, etc.
operating voltage between conductors in
kilovolts.
.
revised
PAGE 28
June. 1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
Coioiog 3?
GC 02943
ASBESTOS-VARNISHED CAMBRIC, COTTON BRAIDED HEADLIGHT WIRE (600 VOLTS)
Nominal
Sice A.W.G.
STANDARD SIZES, DIMENSIONS. WEIGHTS AND PACKAGES
CONDUCTORS Construction
Diameter Inches
INSULATION
THICKNESS Minimum Average
Varnished Compric
Mils
Asbestos Mils
Cation Overall
Bra la Diameter
Thicxness inches
Mils
`
Weigr.:
per 100C Ft Net Lbs.
STANDARD PACKAGES
Feet
Weigh:
per
!OX Ft.
Grass Los
Dielectric Test
Voltage Volts
FLEXIBLE CORDS
300 and 600 Vohs
12
19 x #25
.090
3C
2C 16 .225 39 S00 ICoil: 42 2500
14
19 x *2?
.071
30
20 16 .205 29 SCO (Coil) 32 2500
16
19 x 429
.056
30
20
16
.190
23 1000 (Coil'
26
2500
The above data are approximate and subiect to normal manufacturing tolerances.
ALL-ASBESTOS AND ASBESTOS-VARNISHED
CAMBRIC CAB CORDS
_
Lioht Du`v Ai!-Asbes:cs Insulated (SCO Volts:
Heavy Duty Asbestos-Varnished Cambric Insulated (600 Volts!
STANDARD SIZES, DIMENSIONS, WEIGHTS AND PACKAGES
CONDUCTORS
INSULATION THICKNESS Minimum Average
Nomina ' Six*
Construction Diameter Firs! Varnished Second Inches Asbestos Cambric Asbestos
A.W.G.
Mils
Mils
Mils
Asbestos Bra ic Thick ness Mils
Overall Weight Diameter per
Inches 1CC0 Ft. Net Lbs.
STANDARD PACKAGES
Feet
Weight per
1COO Ft. Gross Lbs.
Dielectric Test
Voltage Volts
LIGHT DUTY ALL-ASBESTOS INSULATED (300 Volts)
10
105 x #30
.120
40
12
65 x #30
..095
40
14
41 x #30
.075
30
16
26 x #30
.059
30
18
16 x #30
.045
30
45 .486 93 250 (Coil) 45 .435 66 500 (Coil) 45 .357 43 SCO (Coil) 45 .327 36 500 (Coil) 45 302 30 500 (Coil)
96 1000 69 1000 46 1CCC 39 10X 33 1000
HEAVY DUTY ASBESTOS-VARNISHED CAMBRIC INSULATED (600 Volts)
10
105 x #30
.120
10
30
IS
45
.54c 93 250 (Coil!
Id
2000
12
65 x .30
.095
10
30
15
45 .49S e: 500 (Coil;
64 2CC0
11
41 X .30
075
10
30
15
45
.457
60 500 (Coil!
63 2CC0
16
26 x #3C
059
1C
30
<5 .40? 51 SX 'Coil)
54 2CC0
16
16 x .30
.045
10
30
15
45 .402 45 SX (Coil1
4S 2000
The obo^e to ore OppTX5TDC\e one SVC ec* ic norjt.qIi rr,onuicc`.ur:ng tolerances
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED
CAMBRIC INSULATED WIRES AND CABLES
Co- '
"
GC 02944
REVISED
PAGE 29
1942
ASBESTOS
STANDARDS
and
FOR ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC
ASBESTOS-
INSULATED WIRES AND CABLES
VARNISHED
CAMBRIC SPECIFI CATIONS
GENERAL
1--Scope: These standards cover elec trical conductors insulated with asbestos or combinations o{ asbestos and varnished cambric and finished with cotton braids, asbestos braids, or lead sheaths, the pur pose, use and constructional dimensions of which are shown in the tables following the text. The rated voltages specified on these tables are phase to phase voltages for either grounded or ungrounded systems.
These standards do not cover multi conductor power cable or other special constructions.
The asbestos insulation after extraction of impregnating compound shall contain not less than 80 per cent by weight of as bestos. The total iron content shall not ex ceed 4 per cent by weight of the asbestos and the magnetic iron content shall not exceed 2 per cent by weight of the asbestos.
The wall of felted asbestos insulation shall be applied to form a smooth wall of uniform thickness as specified in the tables, with the conductor well centered. It shall be thoroughly dried and completely satu rated with a flame-resisting and heatresisting or moisture-resisting compound as specified in the tables. This compound
CONSTRUCTION
2-- Conductors: Unless otherwise spec ified, solid conductors and wires making up stranded conductors shall be of soft copper having, before stranding, physical charac
shall consist of suitable high-grade in gredients and shall retain its initial quali ties during the normal life of the cable. The compound shall develop no injurious chemical action within itself or with any component parts of the completed cable.
teristics in accordance with the following
specifications:
4--Varnished Cloth: The varnished
(a) ASA "Specifications for Soft or An nealed Copper Wire" C8b2, or latest revi sion (for bare copper), or
cambric insulation where used in these wires and cables shall consist of a highgrade varnished cloth substantially free from blisters or other imperfections, applied
(b) ASA "Specifications for Tinned Soft or Annealed Copper Wire" for Rubber In sulation C8bl, or latest revision (for tinned wire).
The conductor shall be solid or stranded as indicated in each table for the particular
with a lubricating compound between layers.
It shall comply in all respects with the requirements for varnished cloth outlined in existing NEMA standards for Varnished Cambric Insulated Cables.
type of wire involved--or as specified on
order.
5--Synthetic Insulation : Synthetic
insulation where used shall be a thermo
INSULATION
plastic compound of the polyvinyl chloride type, or a copolymer of vinyl chloride and
3-- Asbestos: The asbestos insulation vinyl acetate, or a compound of similar
shall consist of best quality, long-fibre,
characteristics. It shall be applied so as to
chrysotile asbestos commercially free from
provide a continuous solid wall of insula
foreign particles of dirt, cotton seed and
tion. General requirements are such that
metallic oxides. It shall be well carded to
the finished wire or cable shall meet all c!
prevent lumps and irregularities in the finished cable.
the performance tests specified herein for
that type.
.
REVISED
PAGE 30
Jun.. 1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
GC 02945
BRAIDS
6-- Cotton Marker Braids for Multi conductor Control Cables: Cotton braids tor this use shall conform tc the Code Braid (commonly known as NEMA Class A Braid) requirements o! ASA Specifications for Cotton Braid for Insulated Wires and Cables, C8.12. Unless otherwise specified, tr.e colors shall conform to the NEMA Color Code for control cable.
7-- Cotton Braids for Outer Cover ings : Cotton Braids for this use shall com ply with the Standard Braid (commonly known as NEMA Class B Braids) require ments of ASA Specifications for Cotton Braid for Insulated Wires and Cables, C8.12.
Cotton outside braids shall be finished with either a suitable flame and heatresisting compound or saturated and fin ished with a flame, heat and moistureresisting compound, as specified in the tables.
8--Asbestos Braids: Asbestos braids shall be closely woven from a good quality, long-fibre chrysotile yarn containing not less than 80 per cent by weight of asbestos. The total iron content shall not exceed 6 per cent by weight of the asbestos. The magnetic iron content shall not exceed 2 per cent by weight of the asbestos.
Asbestos outside braid shall be saturated with either a suitable flame and heatresisting, or flame, heat and moistureresisting compound, as specified in the tables.
LEAD SHEATH
9--The lead sheath shall consist of com mercially pure lead (unless an alloyed sheath is specified by the customer) and shall be tightly formed around the core. It shall comply in all respects with the requirements for lead sheath appearing in existing NEMA standards for Varnished Cambric Cables. The thickness shall be in conformity v/ith that required for varnished cambric cables of corresponding core di
ameter--unless other dimensions are speci fied.
FILLERS 10--Fillers, when used in multi-conductor
control cable shall be of dry jute, unless otherwise specified.
ASBESTOS
and
ASBESTOS VARNISHE CAMBRIC SPECIFI
CABLING
11--In multi-conductor control cables, the individual control wires shall be con centrically cabled together. The lay of con ductors in each layer shall not exceed 16 times the diameter over that particular layer. The lay of conductors in successive layers shall be reversed.
CATIONS
(Continued)
TAPE
12--Multi-conductor control cables shall have the cabled conductors wrapped with a protective tape lapped at least 10 per cent of its width. This tape shall be heli cally applied and shall be under the outer braid.
ELECTRICAL AND PHYSICAL TESTS
13--Unless otherwise specified in the tables, electrical and physical tests shall be made in conformance with the follow ing paragraphs.
ELECTRICAL
14--Initial Dielectric Strength Tests:
(a) All wires and cables specified herein and rated at 600 volts or more: Test voltages as specified in the tables; test to be made on five-foot lengths of finished cable wrapped in tinfoil; voltage to be applied five minutes.
(b) 300-volt rated wires and cables: One thousand volts applied for one min ute; test to be made on five-foot lengths of finished cable wrapped in tinfoil.
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
revised
PAGE 31
GC 02946
ASBESTOS
15--Dielectric Strength After Flame
and
Tests: Samples of cables having beer, previously subjected to the Flame Test (Sec
ASBESTOS- tion 18} shall be prepared with the charred
VARNISHED area of size 6 A.W.G. and larger wrapped in tinfoil, and sizes smaller than 6 A.W.G.
CAMBRIC
buried m iron filings or fine shot and tested
SPECIFI
for one mmute as follows:
CATIONS
(Continued)
(a) All-asbestos insulated wires and
cables rated at 600 volts:
times
the rated voltaae.
(b) Asbestos-varnished cambric insulated wires and cables rated at 600 volts or more: 1times rated voltage.
(c) 300-volt rated wires and cables: 1000 volts.
16--Dielectric Strength While Im mersed: A five-foot sample of finished cables (having flame and moisture-resisting finish) shall be immersed except ends, for one hour in tap water at room temperature and while still immersed, shall withstand a dielectric test of twice the rated voltage be tween conductor and water for one minute.
PHYSICAL
17--Measurement of Dimensional Requirements: Inspection for dimen sional requirements shall consist of four measurements, two tc be made near each end of the sample, of which the average shall comply with the requirements given below. The measurements of cable % in. O.D. and smaller shall be made with a ratchet micrometer having % in. diameter faces. For cable larger than % in. O.D. the measurement shall be made with a circumference tape. Diameter determina tions when made with the micrometer shall be the average of 2 measurements made at right angles to each other. The average diameter over any component layer of the insulation and braid shall not vary more than i 5 per cent from the theoretical diam eter over that layer based on the nominal wall thicknesses shown m the tables.
18-- Resistance to Flame : All of these wires and cables shall have such ::reresisting properties that the test specimens will not convey flame, nor continue to burn for more than one minute after five fifteensecond applications of a standard test flame, the period between applications of the flame being fifteen seconds.
NOTE: Compliance of the wire with the requirements of the preceding paragraph shall be determined with the apparatus and according to the method described in Sections 19 and 20. For dielectric test after flame test see Section 15.
19-- Apparatus for Testing Flame-
retarding Properties: The apparatus for
this test consists of a test chamber of sheet
metal 12 inches wide, 14 inches deep, and
24 inches highTopen at top and front and
provided with means for supporting the test
sample in a vertical position; a Tirrill
burner having a bore of
inch and a
length of 4 inches above the primary air
inlets; a 20-degree angle block for support
ing the bur.'.er; a supply of ordinary illumi
nating gas at normal pressure; a watch or
clock with a hand which makes one com
plete revolution each minute; and flame
indicators consisting of strips of gummed
Kraft paper, 5 mils in nominal thickness
and )4 inch width.
20-- Method of Testing Flameretarding Properties: The test is made in a room from which all drafts are ex cluded. An 18-inch sample of wire is sup ported from the upper end in the test chamber and is held in a vertical position by a four-pound weight attached to the lower end of the wire. A paper indicator is applied to the sample so that the lower edge is 10 inches above the point to which the flame is to be applied. The indicator is wrapped once around the sample with the gummed side toward the conductor and the ends pasted evenly together and pro jecting % inch away from the wire on the opposite side of the wire to that to which the flame is to be applied.
The height of the llame with the burner vertical is adjusted to 5 inches with an
revised
PAGE 32
1942
ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION CAMBRIC INSULATED WIRES AND CABLES
Cotolo? 2?
GC 02947
inner blue cone 1 ^ inches high. The burner is then tilted to an angle oi 20 degrees from vertical and the flame ap plied to the sample so that the tip of the inner blue cone touches the sample at a point approximately 3 inches above its lower end. The side of the flame is brought up to the sample in such a manner that the
vertical plane through the axis o: the burner is perpendicular to the line o: ap proach. The flame is applied for 15 seconds and then removed for 15 seconds. This process is repeated four times.
If more than 25 per cent of the extended portion of the indicator is burned, the wire is considered to have conveyed flame.
SPECIAL TESTS FOR ASBESTOS-VARNISHED CLOTH AND GENCASEAL-ASBESTOS SWITCHBOARD WIRES AND HINGE CABLES
ASBESTOi
and
ASBESTOS VARNISHE CAMBRIC SPECIFI CATIONS
(Continued)
21-- Dielectric Failure Test: A dielec tric failure test of not less than 15,000 volts, 60 cycles, applied between conductors and metal foil, at least 5 inches wide, wrapped tightly around the braid of an unbent sample of wire at least 10 inches long. The voltage shall be raised from initial applica tion of 3000 volts at a rate of approxi mately 1000 volts per second.
22-- Leakage Resistance Test: The leakage resistance between metal foil bands placed two inches apart as measured with a voltage of approximately 200 volts d-c on a sample immediately after exposure for 16 hours at a temperature of not less than 25C. to an atmosphere of moisture in a bell jar in which is placed an open vessel of water, shall not be less than one megohm per inch length per inch of circumference.
23-- Bend--Dielectric Test: On sizes 8 A.W.G.and smaller a 15-mch sample shall be bent 90 degrees around a mandrel hav ing the same diameter as the wire. Two bends in the same plane shall be made 2 inches apart, only sufficient pressure being applied to prevent the sample from slip ping due to its own weight.
A sample subjected to this test shall show no rupture of the covering and it shall not break down at less than 5000 volts, 60 cycles, applied between the conductor and foil wrapped tightly around the braid of the bent sample at the point of the bend (fine filings or shot may be-used in place of wrapping the sample in metal foil). The voltage shall be raised from initial appli cation of 3000 volts at a rate of approxi mately 1000 per second.
SAMPLING
24--Each of the required tests shall be made on one sample of each size and type of wire from each lot of 10,000 feet or frac tion thereof unless otherwise specified in the tables.
If a sample fails to meet any of the pre scribed requirements, two additional sam ples shall be taken from the same length. If either of these samples fail, the length may be rejected. If any of the lengths foil to meet any of the requirements, samples shall be taken from each length or reel of the lot and tested for this particular require ment to determine acceptance oi each reel.
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND GABLES
Coiolog 3?
GC 02948
revised
PAGE 33
Jun. 1942
ALLOWABLE CURRENT
CARRYING CAPACI TIES (National Electrical Code, 1940)
C.M. or A.W.C.
1.000.000 900.000 800.000 750.000 700.000
600,000 500.000 400.000 350.000 300,000
250.000 4/0 3/0 2/0 1/0
1 2 3 4 S
6 8 10 12 14
... .
Three Conductor Cable or Thres Conductors m Conduit
in Ftee A:
Types SNA
AVB
Types AVA
AVi.
Type Ai
Type A
types SNA
Type AVA
Type Al
COPPER TEMPERATURE C.
90 110 125 200 9C no 125
583 556 514 S02 488
681 650 600 582 562
730 665 641 621 598
AMPERES PER CONDUCTOR
811 760 720 690 668
1001 941 879 846 813
1163 1090 1020 981 942
1238 1110 1085 1044 1003
453 404 361 325 299
S2S 468 418 392 347
543 498 450 419 380
612 SS4 488 462 415
738 660 575 529 480
857 765 665 -612 555
912 814 710 653 S92
272 315 334 372 237 275 308 340 209 243 265 284 184 217 230 249 157 190 202 223
427 383 330 284 245
495 446 384 331 287
528 476 410 354 306
138 161 172 188 116 137 147 163 104 121 131 145
88 107 114 122 78 94 99 no
211 247 264
179 211
226
155 182 194
133 158 169
115 136 145
68 80 85 95 SO 60 3 71 38 47 49 54 29 36 38 42 23 28 29 32
99 119 126 71 8S 91 S4 65 69 40 51 52 30 39 40
Type A
290
1332 1240 1150 1118 1065
970 870 7S5 698 632
562 510 429 372 325
280 241 211 180 158
134 100 75 S? 43
CORRECTION FACTOR FOR ROOM TEMPERATURES OVER 30 C.
405C. 104F.
.90
.94
.95
.90 .94 .95
50C. mF.
.80
.87
.89
.80 .87 .89
60C. 140F.
.67
.79
.83
.97
.67
.79
.83
.97
70C. 1S8T.
.52
.71
.76 .93
.S2
.71
.76 .93
eoc. 176F.
.30
.6!
.69
.89
.30
.61
.69
.89
90C. 194F.
IOO*C. 120C. 140C.
212r.
248r. 284r.
.50 61 .86 .SI .82 .72 .63
.50 .61
.86
.51 .82
.72
.62
revised
PAGE 34
1942
NOTE: For copper conductors only one cooies rated at not over 600 volts.
Jh ALL-ASBESTOS AND ASBESTOS-VARNISHED . . GENERAL CABLE CORPORATION
%4/ CAMBRIC INSULATED WIRES AND CABLES
Catalog 3?
GC 02949
A.W.G.
HEAT AND MOISTURE-RESISTING INSULATION
Ms ximurr. Concocts: Temp;rater*
-- -.......... 12SC.
-----------
'-
12SC.
125C
HEAT- RESISTING INSULATION
Msximurr. Condocto: Temperature
2CCC.
300C
300C.
COPPER
NICKEL
MONEL
COPPER
NICKEL.
MONEL
AMPERES
i 172 / A. J 42.C 188 88.2 53.7
2 147 62.0 36.0
163
77.4
46.6
3
131
55.0
32.0
145
68.8 41.5
4
114 48.0
27.9
122
57.9
35.0
6 es 36.3 20.7 95 45.0 27.2
8 63 26.4
15.4
71
33.7
20.3
10
49 20.6
12.0
54
25.6
15.5
12
38 16.0
9.3
42 20.0 12.0
14
29 12.1
7.1
32 15.2
9.1
16 22 9.2 5.4 23 10.9 6.6
18
17 7.1
4.1
18 8.5 5.2
NOTE: Use 80% o: these current ratings when 4 to 6 conductors are laid close together, and 70% lor 7 to 9 conductors.
ALL-
ASBESTOS INSULATED COPPER, NICKEL and MONEL CONDUCTORS
Relative Current Carrying Capacity*
TEMPERATURE CORRECTION FACTORS
Temp. Dag. C.
30 40 SO 60 70
TYPE A!
1.00
.95 .89 .83 .76
TYPE A
Copper
Nickei ond Monel
1.00 1.0C
.97 .98 .93 .96
80 .69 .89 .94
90 .61 .86 .92 100 51 .82 .92 120 .72 .85
140 .63 .30
NOTE. Use 80% oi these current ratings wner. 4 to 6 conductors ere laid close together, and 70% to: 7 to S conductors.
' Sasec on installation eauivalent to three stngie conductor wires in conduit
GENERAL CABLE CORPORATION . . ALL-ASBESTOS AND ASBESTOS-VARNISHED CAMBRIC INSULATED WIRES AND CABLES
Cctolsg 37
GC 02950
revised
PAGE 35
Jun*. 1942
GENERAL CABLE CORPORATION
BARE AND INSULATED CONDUCTORS FOR TRANSMISSION AND DISTRIBUTION
PAPER VARNISHED CAMBRIC RUBBER BRAIDED * LEADED ARMORED AERIAL SUBMARINE UNDERGROUND
CABLE TERMINALS AND ACCESSORIES
All Sizes and Types for Any Condition of Service
"A Standard of Quality for Over Half a Century"
ATLANTA, GA. BOSTON, MASS. BUFFALO, N.Y. CHICAGO. ILL. CINCINNATI, OHIO CLEVELAND, OHIO
SALES OFFICES
DALLAS, TEXAS DETROIT, MICH. HOUSTON. TEXAS KANSAS CITY, MO. LOS ANGELES, CALIF. NEW YORK. N. Y. PHILADELPHIA, PENNA.
PITTSBURGH, PENNA. ROME, N. Y. ST. LOUIS, MO. SAN FRANCISCO, CALIF. SEATTLE. WASH. WASHINGTON, D. C.
PLANTS
BAYONNE, N. I.
EMERYVILLE, CALIF.
PAWTUCKET. R. I.
BUFFALO, N. Y.
LOS ANGELES. CALIF.
PERTH AMBOY. N. J.
ROME, N. Y.
ST. LOUIS, MO.
GC