Document 3Nv0DZwBjqMbaybx373qaVeGO

1.^PLAINTIFF'S 1| EXHIBIT | E-182 1 I I ROCXBESTOS FIREWALLSIS High Performance Switchboard Wire RBB 02930 Rockbestos Firewall SIS Switchboard Wire 600 Volt - 90 C. (194 F.) UL Listed For those customers who require more than the UL minimum Utilities, industrials and other users of switchboard wires are becoming increasingly concerned with quality and performance. To satisfy these demands, Rockbestos offers its superior quality Firewall SIS Switchboard Wire, which is a specially compounded cross-iinked polyolefin insulation that incorporates long-term moisture stability, radiation resistance, flame resistance and excellent aging properties. Passes UL Vertical Test (Not required bv UL for Type SIS) Radiation Resistance Dielectric Breakdown On Single Conductors : >:; n.l:qi sample'' were tv.m >t ~ >r~ t- mariorels cf tne diameters shown and the u-sr>apeo sec tion then immersed in water. A.C. voltage was then ap plied until dielectric breakdown occurred. Values are shown only for the two severest bends, since less severe bends generally produced higher values. Exposure Level Mandrel Diameters 3X1.45") 1X1.15") Unexposed 5 x 107 108 2 x 10 23KV 35KV 30KV 27KV 23KV 34KV 29KV 27KV Serviceable After 2x10 Excellent Aging Long Term Stability in Water (Not Required by UL for Type SIS) (two years in 75% water) 7S 90 121 134 ISO I7S Tmp*fturt C. RBB 02931 Dimensional Data Construction: Solid, stranded or flexible stranded tinned copper insulated with heat, moisture and flameresistant cross-linked polyolefin. Surface printed with size and UL listing. Application: Recommended as a general purpose heat, moisture and flame resistant wire for use in wiring switchboards, panel boards or other electrical apparatus where superior performance is required. Advantages: Resistant to moisture, abrasion, cut through, In addition to meeting all UL requirements, t also passes UL 83 vertical flame test as a superior flameresistant wire. Stranded Conductor Table SISS Size 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 Stranding 7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0772 7/.0994 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 Insulation Mils 30 30 30 45 60 60 60 80 80 80 80 80 Nominal O.D. .140 .160 .180 .240 .320 .370 .430 .470 .545 .590 .640 .690 M Ft. Net Weight 20 28 42 70 113 167 251 310 398 489 604 750 `Ampacity based on 3 conductors m conduit, or enclosed cabinet, 30*C. ambient, at 90*C. conductor temperatures. Ampacity* 25 30 40 50 70 90 120 140 155 185 210 235 Flexible Stranded Conductor ,, Table SISF Size 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 Stranding 41/.010 65/.010 105/.010 133/.0111 133/.0140 133/.0177 133/.0223 259/.01 SO 259/.0202 259/.0227 259/.0255 259/.0286 Insulation Mils 30 30 30 45 60 60 60 80 80 80 80 80 Nominal 0.0. .140 .160 .190 .270 .340 .400 .470 .516 .595 .650 .710 .770 M Ft. Net Weight 20 28 43 75 119 170 254 326 412 508 630 780 `Ampacity based on 3 conductors in conduit, or enclosed cabinet, 30 C. ambient, at 909C. conductor temperatures. Ampacity* 25 30 40 50 70 90 120 140 155 185 210 235 NOTE: Also available in solid conductor (Table SIS). RBB 02932 Copy: ight SW-6/77 -- 2M-11/83 Printed in U S.A. ROCKBESTOS, PRODUCTS 'THE ROCKBESTOS COMPANY Division ot Cerock Wire & Cable Group. Inc. New Haven. Connecticut 06504 USA RBB 02933 Solid Tinned Cooper PVC I Cotton Braid I WIRES TYPE TBS 600 VOLTS $W 3-2-78 Solid Switchboard Wire (NEC Type TBS) Table SPB, 600 Volts, Max. Operating Temp. 90C CONSTRUCTION: Solid stranded or flexible stranded tinned copper insulated with an extrusion of PVC and covered with a flame-proof cotton braid APPLICATION: General purpose 600 voit switcn-ng board wires UL listed ADVANTAGES: Small diameter light weignt and mm: mum cost Size AWG 14 12 10 8 6 Stranding Sohd Solid Solid Solid Solid Insulation Mils 30 30 30 45 . 60 Braid Mils 16 16 16 17 17 Nominal Finished Diameter Inches 16 18 20 22 32 Approx. Net Wgt. in Lbs. per 1000' 26 36 50 81 124 Ampacity* 25 30 40 50 70 Stranded Switchboard Wire (NEC Type TBS) Table SPBS, 600 Volts, Max. Operating Temp. 90 C Size AWG 14 12 10 8 6 Stranding V 0242 7/ 0305 7/ 0385 7/0486 7-'0612 Insulation Mils 30 30 30 45 60 Braid Mils 16 16 16 17 17 Nominal Finished Diameter Inches 17 19 21 27 34 Approx. Net Wgt. in Lbs. per 1000' 28 37 52 85 133 Ampacity* 25 30 40 50 70 Flexible Stranded Switchboard Wire (NEC Type TBS) Table SPBH, 600 Volts, Max. Operating Temp. 90 C Size AWG 18 14 12 10 Stranding 16/.010 41/010 65/.010 104/010 Insulation Mils 30 30 30 30 Braid Mils 16 16 16 16 Nominal Finished Diameter Inches .14 .17 19 21 Approx. Net Wt. in Lbs. per 1000' 17 28 38 53 8 133/0111 45 17 .30 86 6 133/0140 60 17 36 146 `Ampacity based on 30C ambient at 90C conductor temperatures. 3 conductors m conduit, per NEC. Ampacity* 17 25 30 40 50 70 RBB 02934 switchboari WIRES TYPE SIS 600 VOLTS Solid Tinned Copper Cross-linked Synthetic Polymer 1 V4 SW 4-2*78 FIREWALL SIS Solid Switchboard Wire (NEC Type SIS) Table SIS, 600 Volts, Max. Operating Temp. 90 C CONSTRUCTION: Solid, stranded or flexible stranded tinned copper insulated with heat, moisture and fiameresistant cross-linked synthetic polymer APPLICATION: Recommended for application where nuclear power plant class IE cable is required or where superior neat, moisture and flame resistance are required for general purpose wiring of switcnpoaras. panel boards or otner electrical apparatus UL listed ADVANTAGES: Resistant to moisture, abrasion cut through meels the UL 33 vertical flame test, anc passes the IEEE 383 class IE cable test requirements Size 14 12 10 8 6 Stranding Solid Solid Solid Sofid Solid Insulation Mils 30 30 30 45 60 Nominal o.o. 13 15 17 23 30 Stranded Switchboard Wire (NEC Type SIS) Table'SISS, 600 Volts, Operating Temp. 90 C M Ft. Net Weight 19 28 41 69 110 Ampacity* 25 30 40 SO 70 Size 14 12 10 8 6 4 2 1 l0 20 30 4.0 Stranding 1> 0242 7-0305 V 0385 7' 0486 7'0612 7;0772 7' 0994 19/0664 19/0745 19/0837 19/ 0940 19/1055 Insulation Mils 30 30 30 45 60 60 60 80 80 80 80 80 Nominal O.D. 14 16 18 24 32 37 43 47 54 59 64 70 M Ft. Net Weight 20 28 42 70 113 167 251 310 398 489 604 750 Ampacity* 25 30 40. 50 70 90 120 140 155 185 210 235 Flexible Stranded Switchboard Wire (NEC Type SIS) Table SISF, 600 Volts, Operating Temp. 90 C Size Stranding Insulation Mils Nominal O.D. M FI. Net Weight Ampacity* 14 41/.010 30 .14 20 25 12 65/010 30 16 28 30 10 105/010 30 19 43 40 8 133/0111 45 .27 75 50 6 133/0140 60 .34 119 70 4 133/.0177 60 .40 170 90 2 133/.0223 60 47 254 120 1 259/0180 80 .52 326 140 1/0 259/.0202 2/0 259/.0227 3/0 259/0255 4/0 259/.0286 80 .60 412 80 .65 508 80 .71 630 80 .77 780 'Ampacity based on 3 conductors in conduit, or enclosed cabinet. 30C, ambient, at 90C conductor temperatures 155 185 210 235 RBB 02935