Document 3Nv0DZwBjqMbaybx373qaVeGO
1.^PLAINTIFF'S
1| EXHIBIT | E-182
1 I
I
ROCXBESTOS FIREWALLSIS High Performance Switchboard Wire
RBB 02930
Rockbestos Firewall SIS Switchboard Wire
600 Volt - 90 C. (194 F.) UL Listed For those customers who require more than the UL minimum
Utilities, industrials and other users of switchboard wires are becoming increasingly concerned with quality and performance. To satisfy these demands, Rockbestos offers its superior quality Firewall SIS Switchboard Wire, which is a specially compounded cross-iinked polyolefin insulation that incorporates long-term moisture stability, radiation resistance, flame resistance and excellent aging properties.
Passes UL Vertical Test
(Not required bv UL for Type SIS)
Radiation Resistance
Dielectric Breakdown On Single Conductors
: >:; n.l:qi sample'' were tv.m >t ~
>r~ t-
mariorels cf tne diameters shown and the u-sr>apeo sec
tion then immersed in water. A.C. voltage was then ap
plied until dielectric breakdown occurred. Values are
shown only for the two severest bends, since less severe
bends generally produced higher values.
Exposure Level
Mandrel Diameters
3X1.45")
1X1.15")
Unexposed 5 x 107 108 2 x 10
23KV 35KV 30KV 27KV
23KV 34KV 29KV 27KV
Serviceable After 2x10
Excellent Aging
Long Term Stability in Water
(Not Required by UL for Type SIS)
(two years in 75% water)
7S 90
121 134 ISO I7S
Tmp*fturt C.
RBB 02931
Dimensional Data
Construction: Solid, stranded or flexible stranded
tinned copper insulated with heat, moisture and flameresistant cross-linked polyolefin. Surface printed with size and UL listing.
Application: Recommended as a general purpose heat,
moisture and flame resistant wire for use in wiring
switchboards, panel boards or other electrical apparatus where superior performance is required.
Advantages: Resistant to moisture, abrasion, cut
through, In addition to meeting all UL requirements, t also passes UL 83 vertical flame test as a superior flameresistant wire.
Stranded Conductor
Table SISS
Size
14 12 10 8
6 4 2 1
1/0 2/0 3/0 4/0
Stranding
7/.0242 7/.0305 7/.0385 7/.0486
7/.0612 7/.0772 7/.0994 19/.0664
19/.0745 19/.0837 19/.0940 19/.1055
Insulation Mils
30 30 30 45
60 60 60 80
80 80 80 80
Nominal O.D.
.140 .160 .180 .240
.320 .370 .430 .470
.545 .590 .640 .690
M Ft. Net Weight
20 28 42 70
113 167 251 310
398 489 604 750
`Ampacity based on 3 conductors m conduit, or enclosed cabinet, 30*C. ambient, at 90*C. conductor temperatures.
Ampacity*
25 30 40 50
70 90 120 140
155 185 210 235
Flexible Stranded Conductor ,,
Table SISF
Size
14 12 10
8
6 4 2 1
1/0 2/0 3/0 4/0
Stranding
41/.010 65/.010 105/.010 133/.0111
133/.0140 133/.0177 133/.0223 259/.01 SO
259/.0202 259/.0227 259/.0255 259/.0286
Insulation Mils
30 30 30 45
60 60 60 80
80 80 80 80
Nominal 0.0.
.140 .160 .190 .270
.340 .400 .470 .516
.595 .650 .710 .770
M Ft. Net Weight
20 28 43 75
119 170 254 326
412 508 630 780
`Ampacity based on 3 conductors in conduit, or enclosed cabinet, 30 C. ambient, at 909C. conductor temperatures.
Ampacity*
25 30 40 50
70 90 120 140
155 185 210 235
NOTE: Also available in solid conductor (Table SIS).
RBB 02932
Copy: ight
SW-6/77 -- 2M-11/83 Printed in U S.A.
ROCKBESTOS, PRODUCTS
'THE ROCKBESTOS COMPANY Division ot Cerock Wire & Cable Group. Inc. New Haven. Connecticut 06504 USA
RBB 02933
Solid Tinned Cooper
PVC I
Cotton Braid I
WIRES
TYPE TBS 600 VOLTS
$W 3-2-78
Solid Switchboard Wire (NEC Type TBS) Table SPB, 600 Volts, Max. Operating Temp. 90C
CONSTRUCTION: Solid stranded or flexible stranded tinned copper insulated with an extrusion of PVC and covered with a flame-proof cotton braid
APPLICATION: General purpose 600 voit switcn-ng board wires UL listed ADVANTAGES: Small diameter light weignt and mm: mum cost
Size AWG
14 12 10
8 6
Stranding
Sohd Solid Solid
Solid Solid
Insulation Mils
30 30 30
45 . 60
Braid Mils
16 16 16
17 17
Nominal Finished Diameter Inches
16 18 20
22 32
Approx. Net Wgt. in Lbs. per 1000'
26 36 50
81 124
Ampacity*
25 30 40 50 70
Stranded Switchboard Wire (NEC Type TBS) Table SPBS, 600 Volts, Max. Operating Temp. 90 C
Size AWG
14 12 10
8 6
Stranding
V 0242 7/ 0305 7/ 0385
7/0486 7-'0612
Insulation Mils
30 30 30
45 60
Braid Mils
16 16 16
17 17
Nominal Finished Diameter Inches
17 19 21
27 34
Approx. Net Wgt. in Lbs. per 1000'
28 37 52
85 133
Ampacity*
25 30 40
50 70
Flexible Stranded Switchboard Wire (NEC Type TBS) Table SPBH, 600 Volts, Max. Operating Temp. 90 C
Size AWG
18 14 12 10
Stranding
16/.010 41/010 65/.010 104/010
Insulation Mils
30 30 30 30
Braid Mils
16 16 16 16
Nominal Finished Diameter Inches
.14 .17 19 21
Approx. Net Wt. in Lbs. per 1000'
17 28 38 53
8 133/0111 45 17 .30 86 6 133/0140 60 17 36 146
`Ampacity based on 30C ambient at 90C conductor temperatures. 3 conductors m conduit, per NEC.
Ampacity*
17 25 30 40
50 70
RBB 02934
switchboari
WIRES
TYPE SIS
600 VOLTS
Solid Tinned Copper
Cross-linked Synthetic Polymer
1
V4
SW 4-2*78
FIREWALL SIS
Solid Switchboard Wire (NEC Type SIS) Table SIS, 600 Volts, Max. Operating Temp. 90 C
CONSTRUCTION: Solid, stranded or flexible stranded tinned copper insulated with heat, moisture and fiameresistant cross-linked synthetic polymer
APPLICATION: Recommended for application where nuclear power plant class IE cable is required or where
superior neat, moisture and flame resistance are required for general purpose wiring of switcnpoaras. panel boards or otner electrical apparatus UL listed ADVANTAGES: Resistant to moisture, abrasion cut through meels the UL 33 vertical flame test, anc passes the IEEE 383 class IE cable test requirements
Size
14 12 10 8 6
Stranding
Solid Solid Solid Sofid Solid
Insulation Mils
30 30 30 45 60
Nominal o.o.
13 15 17 23 30
Stranded Switchboard Wire (NEC Type SIS) Table'SISS, 600 Volts, Operating Temp. 90 C
M Ft. Net Weight
19 28 41 69 110
Ampacity*
25 30 40 SO 70
Size
14 12
10
8
6
4 2 1
l0 20 30 4.0
Stranding
1> 0242 7-0305 V 0385 7' 0486
7'0612 7;0772 7' 0994 19/0664
19/0745 19/0837 19/ 0940 19/1055
Insulation Mils
30 30 30 45
60 60 60 80
80 80 80 80
Nominal O.D.
14 16 18 24
32 37 43 47
54 59 64 70
M Ft. Net Weight
20 28 42 70
113 167 251 310
398 489 604 750
Ampacity*
25 30 40. 50
70 90 120 140
155 185 210 235
Flexible Stranded Switchboard Wire (NEC Type SIS) Table SISF, 600 Volts, Operating Temp. 90 C
Size
Stranding
Insulation Mils
Nominal O.D.
M FI. Net Weight
Ampacity*
14 41/.010 30 .14 20 25
12 65/010 30 16 28 30
10 105/010 30 19 43 40
8 133/0111
45 .27
75 50
6 133/0140 60 .34 119 70
4 133/.0177
60 .40 170
90
2 133/.0223 60 47 254 120
1 259/0180
80 .52 326 140
1/0 259/.0202 2/0 259/.0227 3/0 259/0255 4/0 259/.0286
80 .60 412 80 .65 508 80 .71 630 80 .77 780
'Ampacity based on 3 conductors in conduit, or enclosed cabinet. 30C, ambient, at 90C conductor temperatures
155 185 210 235
RBB 02935