Document 3NkDZDq4r6aRGG2dj63JxwX0E

Director's Review Meeting CEA 2417 - Aroclor 1016 Column COMPANY CONFIDENTIAL' AGENDA DIRECTOR'S REVIEW MEETING AROCLOR COLUMN - CEA- g4l7 8/5A1 I. II. III. IV. ' V. VI. VII. VIII. IX. Introduction ------------------ -------------- J. R, Savage Objectives - (questions only, will not be reviewed) Chemistry of Process -------------------- D. Cova Q. E. Thompson Summary of Plant Process . and Equipment - N. B. Wolk Financial Status -------- Construction ------------ N. B. Wolk J. Petterson Manning/Training ------------ R. M. McCutchan Start-up Plan ------------ R. M. McCutchan Project Risks a. In Process ---------b. In Design ---------- Cova/Thompson A. J. Heinze c. In Maintenance -- J. Petterson d. In Operations -- R. M. McCutchan MUNS 092802 ii'Wiifrt^iiiin'iirf. itii'i miilt i<tni' flirWr ltiiit'iiiiftih'iii<iiJ*fniia'i'lifaT>im*i"i-'im*~ii 11 ni in i A. Project Organization l . Business Group: , H. S. Bergen - Specialty Products Director J. R. Savage - Manufacturing Manager ' Manufacturing: A. E. Leisy - General Superintendent ' Bob McCutchan - Dept. Supervisor & Mfg. Representative Virgil Brawley - Dept. Foreman & Start-up Foreman Tom Carrico - Dept. Foreman ~ Bill Crabtree - Hourly Foreman Wayne Krull - Start-up Foreman Arnold Eavadll - Start-up Foreman Doug Elden - Cost Analyst Ron Kuster - Laboratory Supervisor Research: '' . W. R. Richard - Manager R. H. Munch Q. E. Thompson . D. R. Cova . ' CEP: . ' R. M. Kountz N. B. Wolk - Project Manager A.J. Heinze - Project Engineer _ Maintenance: . Bill Young - Area Supervisor ' Jim Petterson - Project Construction Supervisor Noel Frltsch - Project Planner ' Roy Purkey -' Project Foreman Ron Leap - Project Foreman . MQNS 09ZB03 *-' f.h,gL-*i.is!n.,.M^yAs:>*-.y PROJECT OBJECTIVES AND PREMISES I. CEA 2417 OBJECTIVES ` The following objectives will be demonstrated: status/comments 1. Meet the CEA 2417 time schedule.' 2. Stay within budgets on construc tion and start-up costs: CEA 2417 Capital CEA 2417 Expense Start-up expense $830 M 95 M 100 M 1. The original Btart-up date was 6/1, but was changed to 8/1 when MCS-1109 vfai added to the scope. & 2. The 2417 budgets inclifdi Variance No. 1 which allowed for facilities produce MCS-1109. It I1d0 > t 'e<tc-er. 1C 1 a appears that both capital and expense will be within budget. 3. Demonstrate design capacity: Aroclor 1016 MCS-1109 54 W/yr. 18 m/yr. 3. Underwriter Laboratories accepted Aroclor 1016,8b being equivalent to 142. If a forecut had been ' necessary, capacity wbuld have been lower on 10J.6. 4. Meet specification qualities on all products. Those affected by CEA 2417 are: Aroclor 1016 MCS-1109 Aroclor 1254 Aroclor 1260 Aroclor 1221 3, No increase in PCS's leaving Dept. 246 via sewers and no more than 1.0 lbs./day - additional to atmosphere. 5. During the first run (only) of MCS-1109, 3-5 lbsj/day of monochloroblphenyl will be discharged to the sewer. 6. No significant change in department biphenyl yield. oia o'* I ROJECT OBJECTIVES AND PREMISES (contd.) p II. KEY DESIGN PREMISES STATUS/COMMEMTS 1. Any remaining phthalic anhydride 1 In .column can be flushed out In Initial startup. . The first run wijll be a "half-size" run pf Aroclor 1016. Assuming acceptable quality, this production will jce used for Thermlnol PR-1. 2 Volumetric control is adequate 2 "End of forward flow" on for determining: MCS-1109 can also be determined by C.p. a. change In reflux ratio "End of forecut" on b. end of crude feed MCS-1109 can alsp be c. end of forward flow estimated by # Biphenyl d. end of forecut for MCS-1109 in forward flow.I Volume control within 250 gal. is necessary on the above determina tions and can be achieved.- 3. Still pot pressure can be controlled such that the furnace outlet temperature will be a maximum of 300C., and the temperature differential on the furnace a maximum of 10C. 4. Still pot bottoms from Aroclor 1016 will be 50# Clg or less. s 5- The C. B. 5+ level will not exceed 0.4# in the finished Aroclor 1016. 6. The C. B. 2+ level will not exceed 1.0# in the finished MCS-1109. 7. PCB discharge to the atmosphere 7. During the first run (onlj will be an estimated 1.0#/day or of MCS-1109, 3-5 Its./day less from the vacuum Jet. There of monochloroblphenyl will will be no significant PCB loss ' be discharged to the to the Bewer from this project, sewer. and none from the vacuum Jet. All sewers will pass through a settling basin. 8. The severity of potential ( hazards in Dept. 246 will not - - -be increased by CEA 2417. 092.&O5 *ons 9. Stainless steel is a suitable material of construction for the Aroclor fractionating column. " j PROJECT OBJECTIVES AND PREMISES (contd.) II. KEY DESIGN PREMISES (contd.) STATOS/COMMENT^ 10. WGK will be the only MCS-1016 supplier and will be reliable. 11. Cross-contamination between Aroclor 1016 and MCS-1109 can be held to an acceptable level. 12. The Isomer distribution of crude for MCS-1109 (5.0# Cl2) that will be produced In the continuous chlorinators will be adequate for the process which was based on batchproduced crude. _ ' III. OPERATIONAL PREMISES 1. Chlorine and biphenyl will be available in adequate quantities and proper quality. 2. WGK will produce Aroclor 1016; MCS-1109; 1 Aroclors 1232, 1242, 1248, 1254, 1260, 1262, and 1221; blends Inerteen PPO, Inerteen 70/30, Inerteen 54201 CM, Pyranol A13B3B, Thermlnol FR-0, and FR-Low Temp, (or their equivalent by other names); Thermlnol FR-1, and MCS-1023. 3. WGK will not produce Thermlnol FR-II or FR-3, or Pydrauls after Antwerp Is In Pydraul operation. ' 4. WGK will rework reclaimable scrap Aroclors or blends. . . 5. Thermlnol FR-1 will utilize Aroclor 1016 and Inerteen 54201 CM will use Aroclor 1242. I 6. The 100# column capacity for Aroclor 1016 will \ be 54 w/yr., and 18 H#/yr. for MCS-1109. Based on the 1971 forecast there will be 2.0-2.5 months of idle' time. 7. The capacity for continuously chlorinated Aroclor . 1142 (crude) will be approximately 54 f3#/yr. Thl,s provides a surge capacity of 5-10# over expected 1971 demand. . MOWS 09 Z86 1 j PROJECT OBJECTIVES AND PREMISES (contd.) III. OPERATIONAL PREMISES (contd.) 8. The sales and use forecast used In designing this project is: Aroclor 1221/faCS-1109 1232 ' 1242/facS-10l6 1248 1254 1260 1971 573" 0.1 (approx.) 40.3 (about 5-0 H of 1242) 1.4 8.4 , 2.7 9. Dept. 246 will have the following delivery capability (bulk): Necessary Lead Time 1 Aroclor 1016 & PR-1 MCS-1109 Aroclor 1254 Aroclor 12o0 Aroclor 1232 Inerteen 70/30 All other blends Anytime 5 days 1 day 2 days 10 days Anytime (assuming installa tion of 70/30 tank) | 3 days - confidence 5 days - 95# confidence Aroclor 1221 and 1242 2 days When possible cars will be loaded prior to the receipt of an order. 10. All products will be available in drums and tankj cars. Commercial trailers can be loaded with non electrical grade products. Electrical grade products - --can be-loaded into trailers reserved for this-service. 11. Aroclor 1016 and MCS-1109 column bottoms will be distilled and further chlorinated to Aroclor 12^4 or 1260. If there is an excess of Btlll bottomsj it will be incinerated. If more 1254 or 1260 is needed, it will be batch chlorinated from biphenyl 12. Off-gas condensate will be further chlorinated to Aroclor 1254. 13. The operation of the Aroclor Incinerator will nqt be an integral part of the Aroclor production department. ' MONS 092801 PROJECT OBJECTIVES AND PREMISES (contd.) III. OPERATIONAL PREMISES (contd.) ' 14. There can he blending of finished lots of Aroclor 1016 as long as each lot is a complete hatch distillation. 15. Construction and tie-in of this project will not interrupt normal production, other than brief shutdowns for piping tie-ins (8-48 hours). 16. Customer acceptance of Aroclor 1016 will be : ' such that there will not be parallel production of Aroclor 1016 and Aroclor 1242 for capacitor use. O < mons SUCTION IV - TRAINING PLANS '1 AROCLOR COLUMN (CEA 2417) ----------TJOTCINE'Or-----------TRAINING PROGRAM a u T u fk v , I. TRAININO FOR SUPERVISION A. General 1. Introduction to Personnel 2. General Introduction . ~b. Safety 4. Pollution Control 5. Tour 6. Department Organization 7. Security 8. Your responsibilities on-this assignment - general B. Present Process & Equipment . Tools: . Flow Sheets Operating Instructions SMP IFO's 1800 Flies Standards Spec. Sheets 1. Each process step In detail 2, Other considerations: a. Safety & safety devices/ ' check list b. Utilities c. Quality d. Quantity e. Material Handling f. Operator responsibility g. Item numbers C. New Process & Equipment (same "tools" as above* plus 2417 drawings and files) 1. .Each process step in detail 2. Other considerations Trainer McCutchan McCutchan McCutchan Me Cutchan Brawley Brawl ey McCutchan McCutchan Brawley Brawley McCutchan Brawley Brawley McCutchan McCutchan Days Required One Four Brawley Brawley Brawley Brawley Brawley Brawley Brawley Ten McCutchan/ Brawley McCutchan/ Brawley 092809 HONS AROCLOR COLUMN (CFA glfl7) OUTLINE OF TRAINING PROGRAM P- C. New Process & Equipment (Cont'd.) ' Trainer a. Safety and material handling b. Quality c. Quantity d. Risk analysis e. Process Control f. Yields g. Identify equipment and process lines h. Operator responsibility D. Preparation for Operator training 1. Write operating instructions for assigned equipment 2. Make flow sheets and data Bheets Water-batching instructions 4. Detailed daily plan for operator training ' Days Required i" , ( HONS 092810 SECTION XV - TRAINING PLANS A. AROCLOR COLUMN (CEA 417) DETAILED MASTER TRAINING SCHEDULE - SHIFT SUPERVISION I. GENERAL Introduction to Key Personnel R. M. McCutchan A. E. Lei By N. B. Wolk A. Helnze F. Werner J. Petterson R. Purkey R. Leap N. Frltsch V. Brawley T. Carrico W. Crabtree D. Elden R. Kuster Mfg. Representative and Dept. Supervisor Group D Supt. Project Manager (CED) Project Engineer (CED) Project Lead Draftsman (CED) Project Shop Supervisor Project Foreman Project Foreman Project Planner ' Dept. Foreman Dept. Foreman Dept. Foreman (Hourly) Cost Analyst Lab II Supervisor General Introduction 1. Introduction to Aroclor How It Is Made Uses . 2. Reason for Column Project 3. Liquid Aroclor Shift to WGK C. Safety 1. General Dept. Safety 2. Cleanup 3. Housekeeping A. Plant Disaster Plan 5. Location of Equipment 6. Fire Zone _ ` D. Pollution Control 1. Reason for Tight Control 2. Review Dept. Procedure for Control 3. Overall Plant Effort on PCB's E. Tour 1. Existing Equipment 2. New Equipment 3. Area 5 Shop MQNS 092811 a. GENERAL (Cont'd.) F. Department Organization Salaried Supervisor Foremen Hourly Relief Foreman & #1 Swingman Repairman Premium Operator Column Operator Still Operator Second Operator ' Standard Operator #2 Swingman Porter . 0. Security 1. Reasons for Security 2. Other Producers H. Your Responsibilities on this Assignment - General 1. Assignments - Shift coverage of entire department, making flow sheets, completing IFO's, devise data I sheets, logging data, training operators, setting personal objectives, etc. 2. Responsibilities - Supervise safe running of equipment by hourly personnel, produce scheduled pounds of quality material as outlined in the Btartup objectives. . ? Authority - Overall direction of all operators and operations. Make decisions on process changes for1 safe -operations and quality material. Have equip-, ment maintained on shifts and weekends. , II. PRESENT PROCESS AND EQUIPMENT A. Process in Detail, using; Discussion Operating Instructions Flow Sheets IFO's 1800 Files Standards Spec. Sheets SMP ( HONS 092B12 II. .PRESENT PROCESS AND EQUIPMENT (Cont'd.) (* B. Other Considerations 1. Safety and Safety Devices (Rupture Discs and Interlocks) 2. Utilities 3. Quality Quantity ' 5. Material Handling (SMP and Operating Instructions) 6. Operator Responsibility ' 7. Item Numbers III, NEW PROCESS AND EQUIPMENT A. Process in Petal] using: ' 1. Model 2. Flow Sheets 3. IFO's A. 17 Drawings 5. Tentative Processes. B. Other Considerations 1. Safety and Safety Devices (Rupture Discs and Interlocks) 2. Quantity 3. Quality . 5). Material Handling 5. Operator Responsibility 6. Item Numbers . Identify Equipment and Process Lines . Yields 9. Risk Analysis 10, Make Log Book for Recording Equipment Data 11, Process Control 12, Control Limits IV. PREPARATION FOR OPERATOR TRAINING Make Flow Sheets For: 1. Individual Training Needs for Operator Training 2. Complete Sheets of Entire 2JI17 Project Water Batching Instructions for Area of Responsibilities: 1. Pressure Testing Tanks and Lines 2. Material to be Used 6 3. Instrumentation and Panel Board Checkout MONS oaU IV. PREPARATION FOR OPERATOR TRAINING C. Write Tentative Operating Instructions for Area of Responsibility D. Make Data Sheets for Operators to Record Pressures, `Temperatures. Etc. E. Write Detailed Dally Plan for Operator Training 1. Classroom ' 2. Field 3. Instrumentation and IFO's 5. Pollution Control . 5. Safety and Plant Disaster Plan 6. Material Handling 7. Troubleshooting 8. Communications ' 9. Work Schedules 10. Water Batching and Pressure Testing Plans 11. Operating Instructions 12. Power Failure 1>. Sampling li. New Data Sheets and Expected Readings 15. Quality ' 16. Utilities . 17. Housekeeping 18. Training with Other Operators muns oviaw o ( p- SECTION IV. TRAINING PLAN B. OPERATOR TRAINING 1. Column Operator Training (outline) let Week General indoctrination Department organization Introduction to personnel Department tour Security of Information Pollution control Plant disaster plan Safety and housekeeping Introduction to'training Training on existing equipment Classroom training Discuss water batching plans Field training. 2nd Week Review training of previous week Water.batching plans Instrumentation " Dry out reboiler furnace Recording data Run existing equipment Drop bottoms Material handling Quality Sampling Process simulation Data sheets 3rd Week Review training of previous week Process and instrumentation Field training on valves and lines Check out reboiler furnace system Run the column Take inventory 09181^ kons I SECTION IV. TRAINING PLAN (COntd.) 1. Column Operator Training (details) lBt Week 1. General Indoctrination Introduction to Aroclor Plant and Department Procedures 2. Department Organization Salaried R. McCutchan - Dept. Supvr. A. Leisy - Prod. Supt. T. Carrico - Foreman V. Brawley - Foreman A. Zavadil - Foreman W. Krull - Foreman D. Elden - Cost Accountant Relief Foreemman . Premium Oper. Still operator Second Operator Standard Operator Repairman Porter 3. Introduction to Personnel ' ; 4. Department Tour Existing Equipment New Equipment | 5. Security of Information . . Reason for security Other producers . 6. Pollution Control Background Customer control Department control Clean-up - 7. Safety and Housekeeping . ; ' Discuss department safety record, eye protection, safe working habits. Location and use of emergency equipment. How to turn in a fire alarm. ' Discuss housekeeping expected. | . Plant Disaster Plan. I 8. Introduction to Training Discuss briefly how training will be done, subjects to be covered and probable timing. 9. Training on Existing Equipment Actual training with still operator on all 1 existing blow tanks, intermediate storage tank. Hi and #2 blend and P.P. tanks, city water system, drowning Jet, 2 still system and porocel treatment. MONS 092816 SECTION IV. TRAINING PLAN (contd.) ' ~1 Column Operator Training (details) 1st Week (contd.) 10. Class-room Training Use model, chalkboard, detail function of each piece of equipment, discuss theory of column operation. Discuss normal operation. . 11. Field Training Discuss equipment and water batching gnd Week 1. Review training of previous week. 2. Discuss water batching plans. Use flow sheets, model ' ! 3. Instrumentation Discuss different types used, location of instruments in field and on panel board. Discuss testing to be done and data to be recorded. , 4. Water batch equipment, check Instruments and dry refractory in furnace. - , ; 5. Run existing equipment ` Run 2 still with the still operator, all blow . tanks, #1 and #2 blend and F.P. tanks, city water systenv and the drowning Jet. 6. Drop Bottoms When #2 still is ready to drop bottoms, drop them in drums. 7. Material Handling Discuss all materials used on the Job in ! respect to toxicity, consistency, special precautions. MONS 092817 V ' SECTION IV. TRAINING PLAN (oontd.) (. 1. Column Operator Training (details) . . gnd Week (contd.) 8. Quality Review spec sheet and tell how the operation will affect material specification. 9. Sampllng Discuss sampling. Importance of good . sampling and how to sample. 10. Process simulation Discuss process start-up. ' 11. Data sheets Review data needed and where to get data. r- i 3rd Week 1. Review training of previous weeks. 2. Make a classroom dry run of charging and running the column and porocel systems. Discuss Instrumentation. ' 3. Make a dry run. In the field, of charging and running the column and porocel systems. Discuss Instrumentation at its location. Check out the reboller system. 5. Charge crude and run column on Aroclor 1016. 6. Take Inventory using new sheets. MGNS 09^818 START-UP FLANS A. General Time Schedule Week No. Date (Week of) Operatlons/Comments 1 8/2 Simulate process, checking for process leaks, vacuum leaks, instrumentation, etc. ; 2 8/9 First distillation run (l/2 slzd) on Aroclor 1016. UBe as j Therminol FR-1 (a new spec, will be necessary). 3 8/L6 Second distillation run of Aroclor loib (EG). 4 8/23 5 8/30 Third distillation run of AroclOr 101b (EG). . Should be able to 1 begin shipments of Aroclor 1016 by 9/1Al- First distillation run of monochloroblphenyl. 6 9/6 Second distillation run of mono! chloroblphenyl. Should be able to begin shipments of mono- by . 9/15/71. B. Sequence for Water Batching and Testing 1. Lime slurry tank 2. Continuous blow tank 3. Vacuum Jet 4. Column 5. Condenser o. Still pot *. 7. Residue tank . 8. Tempered water system and flash tank 9. Vent cooler 10. Finished goods storage tanks 11. Light ends receiver 12. Fuel oil storage tank 13. #2 Intermediate storage tank HONS 092819 START-UP PLANS (contd.) C. Comments on "water batching" Crude Aroclor 1142 will be used for water batching the still pot, lime slurry tank and the residue tank. City water will be used to check out the tempered water . system, vent cooler, and flash tank. Vacuum will be used to check for leaks In the column, condenser and still pot before crude 1142 Is used. , Plant air will be used to pressurize all lines to check for leaks before any liquids are used. The instrumentation and.pumps will be tested during wate^ batching. e MUNS 092820 AREA: VI. OTHER AREAS Specific Potential Problems Preventive Action 1. Can't keep seal in It. ends rec. Low level alarm and loop in suction line to pump. Low risk. 2. Can't, keep seal in #3 prod, tank Add side nozzle 3. Inadecruate PIC on #2 & #3 Abs. Accept ri3k 4. Inadequate Cla Demister capacity Check further into demister capacity ratings 5. Inadequate drown ing Jet capacity Accept risk 6. Inadequate It. ends flow control Accept low risk 7. Inadequate temp, control on #4 fin ished product tank 8. Switch failure on head tk. overflow 9. #7 stg. tk. pump Inadequate 10. Inadequate heat on #7 stg. tk. 11. Alsop filters leak Low risk Low risk 12. Poor TC on F. G. storage tanks Contingent Action Conments Page Responsibility CEL CED FIC may be necessary CED Install a third demister in parallel CED/TSD Install a second drowning Jet in parallel Install FIC on transfer line and LI on tank/ readout in control room Install TIC on F.P. tank Without TIC, temp, will be determined by con denser cooling Blank overflow line to Bi 0 tank; tie-in lower nozzle to #7 overflow CED/TSD mr/csd kr/ced MR CED Install larger coil CED Install TC's. Dept, experience indlcates that Alsop better than Cuno -Current design-is same as on existing storage tanks MR MR/C5D stsjCibuv XSTH Page 7 AREA! V. CONDENSER* VENT COOLER, JET,. THtPERED HgO/CXTY HgO (Continued) Specific Preventive Contingent Potential ProblemsActionActionComnents Responsibility 11. Too many PCB's to atmosphere 12. Too many PCB's to sewer Designed for <1.0#/day to atmosphere. All water except drowning Jet water will go.through a settling hasin Will take air samples Less than 0.5#/day currently leaves Dept. 2^6 via sewers. TSD MR/CED ?G Co o K. rCsDj AREA; T. CONDENSER, VEST POOLER, JET, TEMPERED HgO/CITT HgO Specific Preventive Contingent Potential Problems___________Action__________________________Action____________________Comments 1. Condenser plugs with product Run at 65*C on MCS1016. Low risk of pluggage. Corby oh tempered HaO line for steam 2. Condenser tubes fail 3. HsO pump failure/ power off Break vacuum with Na. Put corrosion samples In condenser head. May want to inspect periodically on a scheduled turnaround. Temperature alarm on tempered watered to condenser TJR1A on vent gases existing vent cooler will alarm at 55 C and shut down furnace at 100C. 4. Aluminum head damage Accept low risk. 5. Vent cooler plugs (on p. 1). e 6. Vent cooler fail3 (covered under Area I,) .c Treat the same as main condenser - monel Is lower risk. 7. city HaO line freezes Trace sections that Drain lines when down, are not In circulating . _ loop. ' 8. Vacuum line plugs Trace and Insulate lines 9. No spare ejector causes too much D/T Accept risk. 10. Can't read bleed valve position due to location Will read out In control room. HONS 092821 Page C Responsibility MR , Malnt/Corr, Group ` CED CED CED MR/CED CED Maint. CED o. AREA; IV. FRACTIONATING COLUMN n ' Page 5 Specific Preventive ' Contingent Potential Problems Action Action 1. Can't hold vacuum Must have good construction 2. Sieve trays plug Accept risk. There Is 3' of disengaged space still pot. Oo to baffles, strainers,.etc. , In vapor line between still pot and columns 3. Can't clean trays Go to valve trays If problem Is extreme. if-. Moisture damages 316 SS. Seldom break vacuum on column/pot system; break with nitrogen. 5. Inadequate control of reflux 6* AP too high (included on p.l). .9 Go to ratio control If necessary Comments Responsibility Maint. . CED CED MR Constant heat equals constant boll up rate. CED x Xc Co <o0 O) Kj AREA: IH. STILL POT, FURNACE, OIL TANK, RESIDUE TANK Specific Potential Problems 1. Still Pot Lie Failure 2. Pump size lnadequate - flow too low Preventive , Contingent Action ' Action Accept risk; displacer Is In a well. Have charged from an Internal pump to an external Sean Bros, pump. Consents - LIC's In similar service In 246 are satisfactory. 3. Can't pump bottoms Will use Bean Bros, out under vacuum pump. Low risk Break vacuum - not a good alternative. 4. Furnace coll plugs with power failure. Gas/oll Interlocked with pump. Six Inch coll not likely to plug due to residual furnace heat. Nitrogen can be used to blow coil clear. 5. Coll falls for other reasons * Accept risk. Plans will be In hand on procedure for chang ing out coil. 6. Can't drain fur nace coll Use nitrogen on Inlet of coll, vacuum on outlet. 7. Fuel FIC not adequate Put on total reflux when changing fuels. If not adequatei go to fuel control by AP on column. B. Oil control system won't work when needed. Check oil system In advance of need. 9. Oil line plugs up to. Won't know when RD has blown on residue tank. Two parallel strainers are provided. Check periodically; nipples provided for checking with air or Ns ` z o z Co o CD Responsibllltv MR CED CED MR/CED- Malnt. MR MJ^/CED MR MR/CED MR c .o AREA: H. #2INTERMEDIATE TANK & LIME SLURRY TANK ' Specific Potential Problems 1. Biff. to clean Preventive Action , ' Contingent Action Accept risk. Eductor Improves situation. 2. Vent line pluggage Low risk between Int. Tk? 3. Dust when charging lime Lime slurry tank vent line will be tied into transfer line whloh is under vacuum 4. Agitator failure Have adequate spare parts.. 5. Level Indicator failure Accept risk 6. Outlet line pluggage Flush line with regular crude 1142 . ft Page Comments ' Responsibilit: Same problem on present Intermediate Tank. MR MR CED ' Malnt. MR MR 3O z <S` o<NC0DNOj' r ns Pag* AREA: X. QUALITY (Continued) Specific Potential Problems 10. Too many heavy fractions Preventive Action None - accept risk Contingent Action Incinerate excess residue 11. Cross contamina tion of MCS-1016 .12 Vent cooler pluggage by product Drain and blow lines as best possible; analyze first T/C's for CB 5+. . . No HaO on vent cooler during light ends cut on MCS-1016 or on Bi jS cut on monochlorobiphenyl Comments Responslblllt Could Anniston use In solid Aroclor produc tion? MR Piping too expensive to completely separate unless absolutely necessary MR Additional steam tracing and insulation will be provided on exhaust system MR/CED 13. Pump lubricants in product 14. First prod, con taminated with phthalic anhfydrlde No risk Dry seal on Aroclor flush seal on all pumps (1) Make thorough physical check of column. (2) Make first batch be monochlorobiphenyl. (3) If first batch is 1016* make It small. (4) Analyze first batch for phthalic anhydride. Slightly contaminated 1016 batch can be used in a non-electrlc application CED MR 15. Vol. control In adequate for good quality Analyze 1242 samples for S. G. vs. higher homologs. 16. Change to 1016 Is staggered. Some storage tanks can be used for either MCS-1016 or Aroclor 1242 Operator must make switch from light ends to product cut. MR/Researc MR HONS 092827 AREA; I. QUALITY Specific Potential Problems Preventive Action Contingent Action Comments Responsibility 1. Isomer separation not adequate Add 3-1" nozzles on side of column for sampling and pressure Increase reflux ratio The tentative spec, of at expense of rate. <0.4 C.B. 5+ is self- imposed and could be changed. ' CED ' 2. High P on column, high temp, in still pot Check further on 300*C Reduce head pres as max. still pot tem sure to a minimum perature (<40 mm). 300*C is not a break point. Level of de composition doubles for every increase of 106. Research 3.F.G. out of spec on S. G. Kake S.G. of crude a control point. MR ' 4. F. G. poorer elect, Low risk. prop, than 1242. Low risk. "Clean room" should be used routinely for 1016. Lab 5. F.G. out of spec, on other prop* .e 6. Lt. ends effect on 1142 quality Analyze light ends for build-up of any contaminant. Provide tee in trans fer line so an out of spec, lot can be brought back to dis tillation system. Purge as necessary 1 CED 1 MR/Researcf 7. Poor chlor. con trol due to lt. ends. Low risk Low risk 8. Poor quality 1254 * 1260 MOMS 09282b Keep close record of current analyses and compare results after jprocess change May have to shorten production run on #2 still and/or boildown less. MR 9. Length of runs on #2 still (Included in above potential problem ) MR H. otart-Up Budget MONSANTO COMPANY Sauget, Illinois Vm. 0. Krummrich February 1, 1971 ' \ cc: G. L. Bratsch B. W. Corlew . R. M. Stovall/j. Littich R. M. Kountz A. J. Koenig . ' SUBJECT: Manufacturing Start-Up ' Expense Budget - CEA 2417 . MCS-1016 Distillation ,T0: Mr. J. R. Savage ' General Offices (3) Attached for the approval of the Organic Chemicals Division, Functional Fluids Business Group, is the proposed manufacturing Btart-up budget for the MCS-1016 Distillation project at WOK. Following is a summary of the manufacturing start-up expense budget: Preparation Phase Operations Phase Contingency (9^) TOTAL . 11,480 '0,370 8,1^0 $500,000 In addition to the manufacturing start-up expense, the following expenses are anticipated:* ' .Divisional Expense Dismantling Repairs Relocations and Modifies tlons Taxes TOTAL 30 M 7.5 M $ 29 M f70. M CED Expenses $5 M *as per A. R. Data Transmittal for CEA 2417 (1/15/71) Total Division expense incurred will be $175M or 21# of the anticipated capital appropriation request ($820ii). This percentage is about "normal". ' 's\ 0 09 1*1* ,'Y '' ( : To: Mr. J. R. Savage Manufacturing Start-Up Expense Budget - CEA 2*117 flCS-1016 Distillation Page 2 2/1/71 V.G.K. The manufacturing start-up expense budget was prepared on the following bases: 1. Chemical start-up will begin, on June 1, 1971. . 2. The key premises on which the project Is based are valid (memo McCutchan to Wolk, 12/10/70). 3. The demonstration period will be completed by / July 31. 1971. The expense charges through May,.1971> will be charged to . Start-Up Job 829-916.62, which will close monthly to 811.00 (expense class 6*1*1), O-. The oharges for June through August that are considered . operational atart-up will be charged to 829-916.62 and will appear.pn the Aroclor cost report as start-up (6*l*t). . /gje APPROVE?DD: - LX-i-CA_____ J. R. Savage R. M. McCutchan Manufacturing Representative e .3 O1' yfiO' ftANUPACTURiriG START-UP BUDGET I Raw Materials Utilities Wages Wages O.H. Salaries '. Salaries O.H.' Supplies Mechanical Expense Laboratory Clothing and Laundry Safety Equipment Technical Services Miscellaneous Oo 4A PREPARATION PHASE -0- $ 2,8?0 $ 7,320 _ $ l,8oo .$ 9,000 $ 1,700 $ 500 $ 2,000 $ 4,500 $ 350 $ 440 $ 500 OPERATIONAL PHASE $ 7,800 $ 5,180 $ 2,600 $ 650 $10,800 $ 2,050 $ 500 $20,000 . $ 7,000 $ 150 -0$ 2,640 $ 1,000 3'OTALS ' $31,480 $60,370 0 MONS 092831 xcs-1016 distilmttcj; 'if?. STAHT-UP BUDGET JAIT. ______ it , . . PHSPABATIOX PHASE________________________________ _____________ OPERATIONAL PHASE FE3. yiARCH APRIL MAY PEEP. . TOTAL JUNE ' JTTCT OPER. AUG. TOTAL Haw Materials - '- - .- - - $ 7800 - - $ 7800 utilities Steam Electricity Oa3 Plant Air Purchased Water Fuel Oil ' - - " - --- - - , $ 1800 $ 1800 $ 2700 $ 900 -- . - - $ 300 -. $ 300 $ -$ 300 $ 60 $ 150 30 . ' -' - $ 350 $ 350 9 350 $ 170 _ - - $ 420 420 S 280 I 140 - - - $ 100 ' - Other Mfg. Wages .- - - $ 900 $ 6420 $ 7320 $ 1700 $ 900 Labor O.H. -- - $ 200 $ 1600 $ 1800 $ -450 $ 200 Salaries 4 4$. 600 600 & 600 $ 1800 s 5400 9 9000 5400 5400 Salaries O.H. 110 110 $ 110 $ 350 $ 1020 $ 1700 $ 1020 $ 1030 _ Factory Supplies -' - - . - $ 500 s 500 $ 500 - _ Mechanical Exp. -- - - S 2000 $ 2000 510000 $ 5000 4 5000 Laboratory -- - $ 1250 $ 3250 $ 4500 s 7000 - . - Clothing & Laundry - - - - s 350 s 350 9 150 - _ Safety Eouipment - - - - $ 500 $ 500 -_ TSD * - . $ 220 $ 220 - - s 440 4 2200 4 440 Miscellaneous " . - $ 500 $ 500 4 - 500 $ 500 .- TOTALS ' $ 710 $ 930 $ 930 $ 4500 $24410 ' ' $31480. $40510 $14860 $ 5000 $ 3600 $ 450 $ 90 $ 520 $ 420 $ 100 $ 2500 $ 650 $10800 $ 2050 S 500 S20000 S 7000 $ 150 $ 2640 $ 1000 $60370 TO DATE SUB-TOTALS ' $ 710' $ 1640 $ 2570 $ 7070 $31480 $40510 $55370 $60370 TOTAL 3UDGET TO DATE $ 710 $ 1640 $ 2570 $ 7070 $31480 $71990 $86850 $91850 *0*3 i I . '- . . . .. ' . MCS-1016 DISTILLATION (CEA 2*H7) START-UP EXPENSE CALCULATIONS & COMMENTS DKfAIL . ' Prep,,. 10,000 gallons of Aroclor 12*12 will allow a double start-up/rinsing of the fractionating column and break-in of related equipment , (June)i 1000 gal. x 10.8 #/gal. x 7.2}!/lb. 2. Utilities Utility usages are estimated as per centages of 1970 average monthly usages. Opbr, $ 7800 a. Steam May - 20$ x 8000 H BTU's x $1,135 June - 30$ July - 10$ - b. Electricity May - 20$ x 1*100 CKWH x $1,098 June - 20$ , July - 10$ c. Gas June - 20$ x *150 Tl BTU's x $0,656 July - 10$ $ 1800 $ 2700 $ 900 $ 300 $; 300 $ 150 -0$ 60 $ 30 d. PJant,,Air . May - 20$ x 20,000 MCP x $0,086 June - 20$. * July - 10$ ' a. Purchased Water ' May '30$ x 8000 M gal. x $0,175 June - 20$ . July - 10$ ' ............ ....... ,f. Fuel Oil ' ' . $ 35.0 $ 350 $ 170 $ *120 $ 280 $ 1A0 Run on oil long enough to check control (June). $100 HONS 092833 .' ....... . . MCS-10I6 DISTILLATION (CEA 2417) ..................... START-UP EXPENSE CALCULATIONS & COMMENTS (con'td.V ... DETAIL .. 3'. Manufacturing Wages - . ' . Prep. . Poor. . . ft. Training (May):. ......... ./ ... . . .. DEW JOB: . . . v.. ' 4 Still Operators x 120 hrs. x $ '1920 $4A>r. . . . .' . . . CURRENT JOBS: (on overtime) ....... .. : 5 Still Operators x 80 hrs. x : |Vhr. x .1.5 ................... - $ 2400 ............. 5 Premium Operators x 16 hrs. x. . $4/hr. x 1.5 '. .1. . .--- . ............... $ 480 -5 Second Operators x 24 hrs. x . $4/hr. x 1.5 ' ..................-............ $ 720 bt Training (June): -------................................................ .. .. . *> overtime over built-in amount - ....... $ 800 c. Hourly Foreman: . ' ........ ............ April thru July @ $900/mo. Will cover for Production Foreman $ 1800 j!i_.ii).or _0ye.rh.ead 23.3^ x $7320 23.3jj X $2600 . . . . . $ 1800 ........... . $ 1800 $ 650 5. Salaries .......... .........: ' .: a. Manufacturing Representative . .* $600/mo. (January thru July) ........... ' ___ $ 3000 $ 1200 b. Production supervisor $300/mo. (May thru July) * c. Start-up Foreman $1200/mo. (April thru July) d. Shift Supervision (3) $I100/mo. (May thru July) * $ 300 $ 600 $ 2400 $ 2400 $ 3300 $ 6600 HUNS 092834 \j00y MCS-1016 DISTILLATION (CEA 2Al7) '' START-UP EXPENSE CALCULATIONS fe COMM)'MS (cont 'd.) pm xl ' Prep. Other 6. Salaries Overhead oo r{ _ -0* ' 19# x $9000 19# x $10,800 . $ 2050 ,7. Factory Supplies Housekeeping supplies, identification tags and signs, miscellaneous (llay- June). ,. $ 500 8. Mechanical Expense . a. Allowance for miscellaneous repair, " modification or relocation expenses required after plant acceptance. (June-August) $20000 b. Temporary connections and modification for process simulation (May). 1 $ 2000 9u~ laboratory Analysis & Methods a.' Analyses at So. 2nd Street (MayJunej. . $ 2000 $ $000 b. WGK analyses during startup (June) .lOOjS of Standard. $ Aooo \ c. AR&D of isomer analysis (April-May). .10=. Clothing and laundry 5# of operating wages fNay) 5# of operating vrages (June) $ 2500 $ 350 $ 350 JlI . Safety Equipment (May) $ 500 ,' ft. Process (June) * 20 days x $88/day $ 1760 b. Materials (Feb.-March) 5 days * $ AAo C. Pollution control (June) 5 dfiys $ AAO d. IPO assistance (July) 5 days mons 09^835 $ A AO Miscellaneous (May-July) 0i0f \ Office supplies, meetings, communications $ 1000 TOTALS GRAND TOTAL $31,AA8B0O $55(0,370 $9i,P'5o TENTATIVE I97g COST STANDARDS MONS 0928^6