M. H. DETRICK COMPANY insulation division TECHNICAL DATA SHEET C L A S S_iiIiLp A G t. DETRICK PYROSCAT FIREPROOFING CEMENTj ______ APPLICATION DETAILS FOR I PLAINTIFF'S STEEL COLUMNS AND BEAMS Ij i EXHIBIT A. Surface Preparation MHD-207 1. Remove dirt, scale or loose paint from the surface to betreafeo; apply rust preventative paint or coating when specified. 2. For trowel applications to columns and beams, form 3/8" rib lath (or paper-backed lath) to box-in the member. Apply rib lath with ribs turned in and spanned from flange to flange. On members 14" and larger, first weld 1/4" rods across the flanges approximately 12" to 18" on centers to provide additional support for the lath. Secure the lath in place with wire or bands. For gun application, use 2x2 #16 paper backed lath such as Steeltex. a) Provide 2" firestops on columns at 8' to 12* intervals (or as other wise specified). Form the metal lath into a horizontal shelf ex tending to and supported at the web. Apply Pyroscat 2" thick in the opening. Provide similar stops at the top elevation of the fire proofing. b) Plasterer's corner bead may be wired to the metal lath, forming and supporting it to attain the total Pyroscat thickness specified. Corner bead shall be of the type having open-mesh legs to facilitate complete filling of the corners. The corner bead may be spaced the proper distance from the flanges by means of corner clips, rods, studs; or Pyroscat may be spotted-in to space the corner bead at specified fireproofing thickness. B. Application of Pyroscat 1. Mix Pyroscat to recommended consistency with clean, fresh water, just before application. Refer to mixing instructions on the bag and use no more water than called for. Mix Pyroscat to a homogeneous plastic mass, avoid over-mixing, particularly with mechanical mixers. a) Apply Pyroscat well into the metal lath, installing approximately 1/2 the total thickness in the scratch coat. Leave the first coat rough or scratch the surface. b) On the underside of beams, the application may be in three coats. Apply a thin scratch coat first to improve adhesion. c) If corner bead was not applied previously, wire it in place when the scratch coat has set. 2. Let the scratch coat harden until well set (4 to 6 hours or longer), then double-back with the finish coat. Apply it flush with the corner bead. Sponge-float the surface to a textured finish or as otherwise specified. a) When application of the finish coat is deferred over night or longer, wet down the scratch coat thoroughly before proceeding with the finish coat. ENGINEERED June 1, 1959 INSULATIONS FOR EVERY HEAT ENCLOSURE C. Curing Pyroscat 1. Pyroscat is a cementitious material; to develop its strength, keep it moist for 72 hours or longer. Depending on atmospheric conditions when applied, the required water retention may be accomplished with wet burlap, periodic water spray or a hydrostatic (resin-base) sealer. 2. Following the curing period and when visual moisture has dried, apply a suitable flashing material ("such as Detrick Duriseal T-178 Coating) at all intersecting joints and exposed ends of the members treated. 3. Pyroscat may be painted with (1) masonry paint, (2) two coats of asphalt-base aluminum paint, or (3) other finishes as specified for operating conditions involved. (Note: When conventional masonry paint of the hydrating-type is used, wet down the Pyroscat before painting to insure proper hydration). < 4 4 A-2 ALTERNATES FOR TOWER SKIRTS (VERTICAL) Attach a layer of l"xl" square mesh reinforcing, positioned 1" away from the skirt, i.e. , at the approximate center of the fireproofing thickness specified. a) Trowel or gun Pyroscat solidly through openings in the square mesh, bringing the scratch coat out approximately 1" thick. Start at the bottom of the skirt and work upward. Leave the surface rough, or scratch it when trowel applied. b) Screed strips may be attached temporarily over the square mesh rein forcing, to accurately gauge the thickness of the second layer. c) When fireproofing is applied to skirts of heated vessels while they are in operation, heat conducted to the skirt may prematurely dry the initial layer of Pyroscat. Wet the first coat thoroughly, particularly at the top, before applying the final layer. A-2 C-3 ALTERNATES FOR HORIZONTAL TANKS Bolster bars are preferred for anchorage of the reinforcing mesh. -The bolster bar selected would have legs extending from the tank surface approx imately one-half of the total thickness of Pyroscat to be applied. Form the bolster bars to fit the tank curvature, then weld or wire in place circum ferentially approximately 3' on centers. Wire the reinforcing mesh to the bolster bars. When tanks so fireproofed are to be operated below ambient temperature, suitable vapor-sealing treatment is recommended after the Pyroscat has been cured, dried and flashed. 4 4 4 4 < 4 4 4 4 4 f