Document 3NerGpeJGM08zKb89vBLZj3Ga

Instruments Consolidated Ashcroft Hancock Co., Inc. Bridgeport, Conn. BRANCHES IN PRINCIPAL CITIES Makers of AMERICAN INDUSTRIAL INSTRUMENTS--Since 1851 . Subsidiary of Manning, Maxwell and Moore, Inc. Manufacturers of Indicating and Recording Gauges; Gauge Testers; "U" Gauges; Draft Gauges* Indicating and Recording Thermometers; Tachometers; Dial Thermometers; Pressure and' Temperature Controllers; Electric Temperature Controllers; Pop Safety and Water Relief Valves; Steam Traps; Engine Indicators; Counters; Absolute Pressure Gauges. Also manufacturers of Bronze. Cast Steel and Forged Steel Valves, Locomotive and Engine Room Clocks; Barometers; Mercury Column Gauges; Steam Whistles; Hydraulagraphs;-Gauge Boards Ashcroft American Gauges--Ashcroft American Gauges are made in all sizes from 2^ to 12 in., for pressures from 8 oz. to 25,000 lb. and also for vacuum. Cases are cast-iron or cast brass. The move ments are Heavy Duty and all bear ings are Monel Met al. Write for Cata log No.- A-59. For Mercury Pressure and Vacuum Gauges, "U" . Gauges, Draft Gauges and Mercurial Barometers, write for Catalog B-59. American Recording Gauges--Ameri can Recording Gauges are made for all pressures from 15 in. of water to 10,000 lb. and for vacuum. They are made in one size, only to accom modate a 10 in. chart, having an effective scale width of in. The case is Die Cast with a dull black hard-rubber finish and with either bot tom or back connection. The pen-arm is made of non-corrosive Monel Metal and is of the inverted type. Operating instruc tions are lithographed on the chart plate so that they cannot be lost. Especially designed Seth Thomas clocks are used, and all customary time periods can be furnished. American Recording Gauges areequipped with the Time Punch which virtually . makes each instrument a time clock, since a hole is punched in the chart whenever a reading is taken. Write for Catalog E-59. American Air Duct Thermometer-Designed especially for both warm and cold air ducts. Fitted with chromium plated frame, glass front. Fur nished with 9-in. or 12-in. scale graduated 0-160 F. Write for Catalog F-59. American Recording Thermometers-- Made for recording temperatures from minus 40 to plus 1000 F. or equivalent C. Very flex ible connecting tubing up to 200 ft. One size only to accommodate 10 in. chart, with an effective scale width of 3$^ in. Same case as for the American Recording Gauge, so that all instru ments are uniform in ap pearance . when mounted on Gauge Boards. Ameri can Indicating Gauges and Dial Thermometers are also furnished in same case. Write for Catalog H-59. American Dial Thermom eters--American Dial (mercury-filled) Indicating Thermometer has theaccu racy of the standard glass tube thermometer and the reading convenience of a dial face. Entire working mechanism is madeofsteel, meaning long life. Standard-size.x>f dial 6 and 12 in. Furnished with rigid connection or flexible capillary steel tubing up to 200 ft. long. For temperature ranges from minus 40 to plus 1000 F. Write for Catalog G-59. American Precision Temperature Controllers--Self-operated and simple in construction. For regulating tempera tures from 25 to 385 F. Under fa vorable conditions temperature will be held within 1. Sen sitive, rugged and accurate. For hot water service tanks, water heaters, etc. Standard ranges carried in stock. Size of valve must be specified. Write for Catalog R-59. 838 Instruments Illinois Testing Laboratories, Inc. 422 N. La Salle St., Chicago, Illinois TESTING ENGINEERS AND MANUFACTURERS "Alnor" Indicating Pyrometers--Portable and Stationary. "Alnor" Surface Temperature Pyrometers. "Alnor" Distant Reading Resistance Thermometers. Boyle Velometers--Air Velocity Meters. BOYLE VELOMETER \ "ALNOR" DISTANT READING The Velometer is a direct reading air Resistance Thermometers velocity meter which gives accurate and Sudden instantaneous readings of the speed and changes in out direction of <pr flow, measured in feet per door tempera- minute. tures need The low scale is ideal for measuring the magnitude and direction of drafts, either ascending or descending or horizontal air movements. These velocities can be obtained accurately to as low as 20-ft. per minute. never bother the engineer of the heating or air condition ing plant who hasan "Alnor" distant reading The high thermometer. scale is de This instru signed for ment will tell Model AR-RM measurement him without Thermometer of air veloci leaving the ties ranging boiler room, the outdoor temperature as from 200 to well as the temperature of as many points 2000 - ft. per within the building as desired by simply minute. turning a small switch knob. Special scale The instrument itself can be located in ranges can be the boiler room or conditioning plant with furnished for the elements mounted at desired points velocities anywhere within the building or outdoors form C ranging from Boyle Velometer 200^tO 4000 ft. per minute. Accurate determinations are obtained without the use of a stop watch or any mathematical calculations. up to a distance of 1000 ft. or more from the instrument. These elements are con nected to the switch of the instrument by ordinary duplex copper wire. Anyone familiar with simple wiring can make the installation. Attachments includingtubeandspecially "Alnor" distant reading thermometers designed jets permit the testing of inlet are made in several types and sizes. and outlet grilles. An averaging jet is used to determine the average velocity over a Send for fret information four inch circle. A small orifice jet is used "ALNOR" SURFACE for exploring the velocities through the irregular shaped openings in ornamental grilles. A specially designed jet is used for the determination of air speed through high velocity grilles of the narrow slot type. Special scales and attachments can be designed and built for any unusual applica tions, such as extremely low, or high velocities, high temperatures, obscure locations, surging air currents, air leakage rom ducts, and through building walls. When required, a certified calibration chart can be furnished with each meter. TEMPERATURE PYROMETERS For measuring surface tempera /tures of steam pipes, radiators, furnace jackets, hot air pipes and similar service, the "Alnor" Pyrocon Pyrometer is a very handy and satisfactory instrument. ? The Combination Pyrocon can be furnished in any of several scale ranges from 0-300 F. to 0-1200 F. As many as five different forms of quickly interchangeable thermo couples can be supplied to suit Write for literature different applications. \ Ask for Bulletin No. 17B7 839