Document 3NZv0eYx13OgjOogBqy7vKVn6
ABERDEEN CHEMICAL PLANT ROUTINE CHEMICAL DOSIMETRY SUMMARY
MONTH OF: September, 1981
DATE OF REPORT: October 9, 1981
c: Jf, CRM, PEM, JRM, RDJ, TBD, SJV, RAF, RAM, AHS T. G. Grumbles - Houston, 0. D. Steffey - Ponca City
ALL SAMPLE RESULTS:
Chemical
VCM Lead Antimony Total Particulates
< PEL No.
%
86 92 5 100
4 100 4 100
~> PEL OVEREXPOSURES No. %
78 00 00 00
OVEREXPOSURES:
Job Class
Vinyl Shift Supervisor Reactor Operator Reactor Operator
Chief Operator
Exposure t
1.0' ppm VCM 1.1 ppm VCM *1.1 ppm VCM
*1.4 ppm VCM
General Mechanic Reactor Operator Chief Operator
*5.2 ppm VCM *13.0 ppm VCM *13.6 ppm VCM
Source
Specific cause not identified.
Specific cause not identified.
Drained "knock-out" tank in new vinyl area.
Employee replaced "0" ring on 0500 Lenape and corrected
i
malfunction at "B" vacuum pump in old reactor area.
Employee helped clean VCM lines during shutdown.
Old vinyl area recovery system plugged.
Old vinyl area recovery system plugged. (Same time as 13.0 ppm sample above.)
A
* Respiratory prelection worn
*
VAB.0001073492
%<
PEL
100
VCM
0 100
Lead
0
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
100
Total Particulates
0
0) A
__ -
w
=8 II
m ac>
I
a> I 1 i &
VAB.0001073493