Document 3NKkLMvrrmVDq3aYyeZD82160

TECHNICAL CENTER SERVICES UNION CARBIDE CORPORATION ENGINEERING AND TECHNOLOGY SERVICES SOUTH CHARLESTON, WEST VIRGINIA MEMORANDUM February 1, 1984 BUSINESS CONHDENTIA To: J. W. Karn Sistersville Plant CC : J. W. Barna M. E . Bell M. W. Bosserman C . P . Maxwell M. L . Mills R. L . Noble D. R. Paugh R. E. Peele H. H. Price B. H. Avashia, M R. G. Rowe, M.D. From: M. A. Patel Subject: Asbestos Monitoring of Construction Employees at the Sistersville Plant On January 12, 1984, Mark Bell and this writer of the Technical Center Industrial Hygiene group visited the Sisters ville Plant to conduct personal exposure monitoring for asbestos fibers while Constructrion Department employees stripped asbestos-containing insulation from pipes at the Steam Plant. The monitoring was done during the entire stripping operation for that day. The balance of the day when there was no monitoring done, the insulators used that time to in sulate the stripped pipes with non-asbestos insulation. The results of monitoring are shown in the attachment which show that all the employees who were monitored worked in the area where the potential for exposure to asbestos was below the cur rent Federal OSHA standard of 0.5 fibers per cc of air. All employees involved in the stripping operation wore full body hooded coveralls, gloves, safety glasses and respirtor approved for use for asbestos. The area was properly barricaded, insu lation was wetted down while stripping and the gratting was covered to collect any insulation which might fall down. Please notify all monitored employees of their exposure results. MAP/sc Attachment UCC 016611 BUSINESS j c*aai<>4 CONFIDENTIAL PERSONAL EXPOSURE MONITORING FOR ASBESTOS AT THE SISTERSVILLE PLANT January 12, 1984 NO. NAME CRAFT SAMPLING TIME/MIN EXPOSURE LEVEL Fibers o 00 1 R.L. Pauley Insulator 2 B.E. Kelly Laborer 3 H.P. Stewart Insulator 4 R.L. Hilverding Insulator 5 L.R. Shaffer Insulator 89 82 88 88 86 . 27 . 15 .24 . 17 UCC 016612 I INTERNAL CORRESPONDENCE busincss i confidential UNION CARBIDE CORPORATION TECHNICAL center P.Q. BOX 336 1 , SOUTH CHARLESTON, WV 25303 a R. C. Proffitt 511-2009 512 M. E. Bell C. W. Maxwell M. L. Mills L. R. Noble D. R. Paugh R. E. Peele A. L. Postlethwait W. F. Williams 2a,a June 21, 1983 ar^natng^o: 511 Industrial Hygiene/ Environmental Protection Asbestos Monitoring in Storeroom, 511 Construction Department_______________ Dear Mr. Proffitt: On May 9, 1983, the Technical Center Industrial Hygiene group conducted a monitoring survey for determining the exposure of employees to asbestos dust particles while handling asbestos containing gaskets in the storeroom at the 512 Construction Department. This work was done by M. E. Bell of our group. Mr. J. H. White was monitored for asbestos exposure when he received one hundred asbestos spiral-wound gaskets in three bundles. During the monitoring period, Mr. White removed these gaskets from the box, counted and placed them in a storage bin in the storeroom. Mr. White wore a dust respirator approved for asbestos while performing the job. In addition to the personal sample, an area sample was also collected. The results of monitoring shown in the attachment indicate that exposure to asbestos fibers above the permissible exposure limit of 2 fiber/cc are unlikely. It is our observation that while unpacking and placing gaskets in the bin the probability of exposure is minute; however, it is believed that once the gaskets are stored in the bin some dust will become loose due to friction and may build up over a period of time. We recommend that the gasket storage bin be cleaned once every month. The person cleaning the bin should wear a dust res pirator. The method of cleaning the bin should be wet. The easiest way would be to rinse the bin with water in the sink. Please notify Mr. White of his exposure results. If we can UCC 016613 R. C. Proffitt 2 06/21/83 be of further assistance, please call us at extension 3750. Very truly yours, rw-i-- X.&J MAP/sc Attachment Manhar A. Patel UCC 016614 ASBESTOS SAMPLING May 9, 1983 rw* 1 BUSINESS CONFIDENTIAL Name or Location 1. J. H. White 2. Area Sample Sampling Time (Mins) 10 9 Concentration Fibers/cc 0 < .07 The permissible exposure limit is 2 fibers > 5 pm/cc of air UCC 016615 T j."an76w V w ^ " CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: r. F. Painter, Trlr. 5583 ASBESTOS me Computer Ref. W-1315 Date April 26, 1982 cc: B. H. Avashia, M.D., 23-512 . G. W. Bott, 701-330 M. L. Mills, 2149-512 ' L. R. Noble, 2149-512 R. E. Peele, 701-334 E. C. Shipley , 2009-512 PERSON MONITORED _________________________ D. C. Shamblin_______________________ Location Bldg. 706 Date 04/21/82 EXPOSURE RESULTS Sample No. 1 2 Cone. fibers > 5 1 ^ Lim/cc fibers > 5 1.0 nm/cc Sampling Time 92 Mins. 93 Mins. 3 4 5 6 Comments Personal sample Area sample Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 gm/cc Ceiling x OSHA ____OSHA ____UCC ____UCC __;__Other Other COMMENTS Personal and area samples were collected,while Mr. Shamblin and Mr. Templeton were stripping insulation from a steam line and condensate line in the old compressor room, Building 706. We recommend the insulators continue to wear protective clothing, respirators, gloves and the area to be stripped wet down. Please inform IH Department of the next stripping job in this area and inform concerned employees of their exposure. WORK BY Mark E. Bell APPROVED BY rW-JU- A . fjJ Manhar A. Patel UCC 016616 BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: r. F. Painter, Trlr. 5583 ASBESTOS Computer Ref. W-1315 Date April 26, 1982 cc: B. H. Avashia, M.D., 23-512 G. W. Bott, 701-330 M. L. Mills, 2149-512 ' '? L R Noble, 2149-512 R. E. Peele, 701-334 E. C. Shipley , 2009-512 PERSON MONITORED Location R. E. Templeton Bldg. 706 Date 04/21/82 EXPOSURE RESULTS Sample No. Cone. 1 0.9 fibers >5 p.m/cc 2 3 4 i` 5 6. Sampling Time 92 Mins. Comments Personal sample Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 pm/cc Ceiling ___________ X OSHA ____OSHA ____UCC ____UCC ____Other ____Other COMMENTS Personal and area samples were collected while Mr. Shamblin and Mr. Templeton were stripping insulation from a steam line and condensate line in the old compressor room, Building 706. We recommend the insulators continue to wear protective clothing, respirators, gloves and the area to be stripped wet down. Please inform IH Department of the next stripping job in this area, and inform concerned employees of their exposure. WORK BY %iJl Mark E. Bell ________ APPROVED BY UCC 016617 X. Manhar A. Patel CC: L. R. Noble, 511-2149 R. F. Painter , 511-5583 R. E. Peele, 701-334 R. G. Rowe, M.D., 791 W. T. Shelton, 704 Shop E. C. Shipley, 511-2009 PERSON MONITORED Location Warren Abbot, Paul Crowder, and Dave Shamblin Building 701-100___ ____ Date 02/16/82 EXPOSURE RESULTS Sample No. Cone. Sampling Time 1 1.16 fibers/* ;c 50 Mins. 2 0.09 fibers/* :c 150 Mins. 3 4.4 fibers/* :c 50 Mins. 4 0.14 fibers/* :c 150 Mins. '5 1.07 fibers/* ;c 50 Mins. 6 0.27 fibers/* :c 115 Mins. Comments Personal sample - Warren Abbot 1105-1155 hours (morning) Personal sample - Warren Abbot 1305-1535 hours (afternoon) Personal sample - Paul crowder 1105-1155 hours (morning) ^Construe.) (Uonstruc.) tConstruc.) Personal sample - Paul Crowder (Construe.) 1305-1535 hours (afternoon) ! Personal sample - Dave Shambim (Insulat) 1105-1155 hours (morning) ; Personal sample - Dave Shamblin (Insulat) 1305-1500 hours (afternoon) UCC 016618 INDUSTRIAL HYGIENE MONITORING FOR TO: cc: See Page 1 2W4) ASBESTOS P. 2 of 2 Computer Ref. W-1401 Date March 19, 1982 PERSON MONITORED ________________Area Sample________________________________________ Location Building 701-100 Date 02/16/82 EXPOSURE RESULTS Sample No. Cone. Sampling Time 7 1.32 fibers/ cc 47 Mins. 8 0.37 fibers/ 'cc 143 Mins. 9 1.35 fibers/ 'cc 47 Mins. 10 0.56 fibers/ 'cc 143 Mins. Comments Area sample - North end Room 106 1108-1155 hours (morning) Area sample - .North end Koom 1310-1533 hours (afternoon) Area sample - South end Room 1108-1155 hours (morning) Area sample - South end Room 1310-1533 hours (afternoon) 100 10U 10U Not enough sampling time Time-Weighted Average Concentration (TWA) to determine TWA Ceiling Concentration ALLOWABLE EXPOSURE (8-Hour Shift) TWA i Ceiling 2 Fibers/cc X QSHA OSHA _UCC UCC _Other Other COMMENTS Two Construction workers and one insulator were monitored for exposure to asbestos fibers during an insulation cleanup operation in Building 701-100. The insulator worked on stripping old insulation from a small section of steam line while the two Construction workers vacuumed old insulation particles and dust from the tops of the fume hoods, the ceiling, duct work, walls, and in strument panels. All workers wore gloves, coveralls, shoe covers, safety goggles, and fresh air masks. Workers were monitored during the entire work period.-^ Please report results to employees. WORK BY Mario F. Stowers APPROVED BY ' Manhar A. Patel UCC 016619 / /- INDUSTRIAL HYGIENE MONITORING FOR TO: J. E. Midkiff, Trlr. 5583 (511) ASBESTOS Computer Ref. W-1402 Date March 19. 198!* cc: L. R. Noble, 511-2149 R. F. Painter, 511-5583 R. E. Peele, 701-334 R. G. Rowe, M.D., 791 W. T. Shelton, 704 Shop E. C. Shipley, 511-2009 PERSON MONITORED Warren Abbot Location Building 701-100 Date 02/17/82 EXPOSURE RESULTS Sample No. Cone. Sampling Time 1 0.13 fibers/ cc 190 Mins. 2 0.04 fibers/ cc 140 Mins. 3 0.03 fibers/ cc 183 Mins. 4 0.01 fibers/ cc 136 Mins. 5 6' 0.10 fibers/ cc 0.02 fibers/ cc 183 Mins. 136 Mins. Comments Personal sample - Warren Abbot (Con struction) 0820-1130 hrs. - morning Personal sample - Warren Aooot (con struction) 1310-1530 hrs. - afternoon Area sample - North end Room iuu 0822-1125 hrs. - morning Area sample - North end Room 100 1316-1532 hrs. - afternoon Area sample - South end Room 1UU 0822-1125 hrs. - morning Area sample - South end Room 100 1316-1532 hrs. - afternoon Time-Weighted Average Concentration (TWA) 0.06 fibers/cc Ceiling Concentration _______-_________________ ALLOWABLE EXPOSURE (8-Hour Shift) TWA Ceiling s 2 Fibers/cc X QSHA ____OSHA ____UCC UCC ____Other Other COMMENTS Construction -worker monitored for exposure to asbestos fibers -while performing cleanup operation of old insulation and dust in Building 701-100. Insulation and dust particles were collected by means of a vacuum cleaner. Worker -wore gloves, coveralls, shoe covers, safety goggles, and a fresh air mask. Monitoring done during entire work period. Time-weighted average com puted based on results of personal exposure over the entire day. Please notify employee of results. WORK BY Mario F. Stowers APPROVED BY UCC 016620 X * PM Manhar A. Patel 2- INDUSTRIAL HYGIENE MONITORING FOR TO: J. E. Midkiff, 511-5583 (Trlr) ASBESTOS Computer Ref. W-1405 Date March 19. 1982 cc: L. R. Noble, 511-2149 R. F. Painter, 511-5583 R. E. Peele, 701-334 R. G. Rowe, M.D., 791 W. T. Shelton, 704 Shop E. C. Shipley, 511-2009 PERSON MONITORED Location Paul Crowder Building 701-100 Date 02/17/82 EXPOSURE RESULTS Sample Cone. Sampling Time 1 0.11 fibers/ cc 190 Mins. 2 0.08 fibers/ cc 140 Mins. 3 4 5 6 Comments Personal sample - Paul Crowder (Con struction) 0820-1130 hrs - morning Personal sample - Paul Crowder (Con struction) 1310-1530 hrs. - afternoon Time-Weighted Average Concentration (TWA) _______0.09 fibers/cc Ceiling Concentration __________-_________________ ALLOWABLE EXPOSURE TWA Ceiling 2 Fibers/cc X__OSHA OSHA ____UCC UCC ____Other Other COMMENTS Construction worker monitored for exposure to asbestos fibers while performing cleanup operation of old insulation and dust in Building 701--100. Insulation and dust particles were collected by means of a vacuum cleaner. Worker wore gloves, coveralls, shoe covers, safety goggles, and a fresh air mask. Monitoring done during entire work period. WORK BY W1JLAv<t/U Mario F. Stowers rn f) A APPROVED BY 1 ________________ Manhar A. Patel UCC 016621 BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: W. T. Shelton, 704 Shop mo\) ASBESTOS Computer Ref. W-1274 Date Feb. 1, 1982 cc: B. H. Avashia, M.D., 23-512 J. R. Hall, 8745-514 , L. R. Noble, 511-2149 M. A. Patel, 701-330 D. R. Paugh, 511-2009 R. E. Peele, 701-334 R. G. Rowe, M.D., 791 PERSON MONITORED W. G. Wheeler Location 704 Powerhouse Date 1/26/82 EXPOSURE RESULTS Sample No. 1 2 Cone. 3.6 fibers >5 |jm/cc 3 4 5 6 Sampling Time 28 Minutes Comments Personal sample Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 ^m/cc Ceiling - X QSHA ____OSHA ____UCC UCC ____Other ____Other COMMENTS Personal samples were collected while Mr. Agosti and Mr. Wheeler were stripping insulation from aerator and connecting lines on the second level in 704 Powerhouse. The levels of asbestos fibers found were in excess of OSHA standard of 2 fibers <5 pm/cc. We recommend the insulators continue to wear protective clothing, respirators, gloves and the area to be stripped wet down. Please inform IH Department of the next stripping job in this area and inform concerned employees of their exposure. WORK BY M.E. Bell APPROVED BY UCC 016622 .J>77oG. W. Bott BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: w. T. Shelton, 704 Shop / ASBESTOS 2<?` Computer Ref. W-1274 Date Feb. 1. 1982 cc: b. H. Avashia, M.D., 23-512 J. R. Hall, 8745-514 L. R. Noble, 511-2149' M. A. Patel, 701-330 D. R. Paugh, 511-2009 R. E. Peele, 701-334 R. G. Rowe, M.D., 791 PERSON MONITORED ______________________ P. J. Agosti_______________________________ Location 704 Powerhouse Date 1/26/82 EXPOSURE RESULTS Sample No. Cone. 1 3.08 fibers 5 11 m /r* 2 3 4 5 6' Sampling Time 26 Minutes Comments Personal sample Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cc Ceiling - X OSHA ____OSHA ____UCC ____UCC ____Other ____Other COMMENTS Personal samples were collected while Mr. Agosti and Mr. Wheeler were stripping insulation from aerator and connecting lines on the second level in 704 Powerhouse. The levels of asbestos fibers found were in excess of OSHA standard of 2 fibers >5 pm/cc. We recommend the insulators continue to wear protective clothing, respirators, gloves and the area to be stripped wet down. Please inform IH Department of the next stripping job in this area and inform concerned employees of their exposure. WORK BY M. E. Bell APPROVED BY UCC 016623 G. W. Bott n business "J CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS Z\ J ( TO: r. F. Painter , Trlr. 5583 Computer Ref. W1167 04/22/81 CC: C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 PERSON MONITORED R. E. Peele, 701-334 E. J. Tawney, Trlr.558 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 J. F . Chandler Location EXPOSURE RESULTS West end - Bldg. 773 Outside at tank pad Date ______04/20/81 Sample 1 2 3 4 5 6 Cone. fibers i> 5 < . 1 pm/cm^ fibers > 5 < 1 (im/cin^ Sampling Time 78 minutes 125 minutes Comments A.M. - Stripping P.M. - Stripping, bagging and cleanup Time-Weighted Average Concentration (TWA) Ceiling Concentration <.l Fiber > 5 gm/cm ALLOWABLE EXPOSURE TWA 2 Fibers >5 pm/ (^OShJ) Ceiling OSHA UCC Other UCC Other COMMENTS Insulator monitored -while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He -wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill. WORK BY APPROVED BY XXkX UCC 016624 r^Tl BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS &J(1) TO: R. F. Painter, Trlr. 5583 Computer Ref. W1167 04/22/81 CC: Q' W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 E. J. Tawney, Trlr H. L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED D. C. Shamblin Location West end - Bldg. 773 Outside at tank pad EXPOSURE RESULTS Date 04/20/81 Sample 1 2 3 4 5 6 Cone. fibers > 5 1 um/cm3 fibers > 5 . 2 ^.m/cm^ Sampling Time 85 minutes 123 minutes Comments A.M. - Stripping P.M. - Stripping, bagging and cleanup Time-Weighted Average Concentration (TWA) .1 Fiber > 5 um/cm3 Ceiling Concentration ALLOWABLE EXPOSURE TWA Ceiling UCC UCC Other Other COMMENTS Insulator monitored while stripping approximately 100 feet of 1-1/2" pipe of suspected asbestos containing insulation. He wore coveralls and a disposable Norton dust respirator. The insulation was properly bagged and tagged for disposal at the landfill. WORK BY APPROVED BY M ex----- ;X . UCC 016625 INDUSTRIAL HYGIENE MONITORING FOR TO: R. F. Painter , Trlr. ~/?*f ASBESTOS Computer Ref. W-1198 Date July 17. 1981 cc : C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, Trlr. 5583 PERSON MONITORED J. F. Chandler Location West end Bldg. 774 behind Date 07/10/81 parking lot to south end of parking lot EXPOSURE RESULTS Sample No. 1 2 Cone . fibers >5 .4 pm/cm^ fibers >5 . 1 pm/cm^ Sampling Time 160 Minutes 164 Minutes Comments A.M. sample - stripping insulation P.M. sample - stripping insulation 3 4 5 6 Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA ,3 2 fibers >5 pm/cm Ceiling x OSHA OSHA ____UCC UCC ____Other Other COMMENTS Stripping approximately 450 feet of 4-inch steam line which had been turned off so the line could cool. Ruth Clise APPROVED BY UCC 016626 Manhar A. Patel \ UNION BUSINESS [carbide CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: R. F. Painter , Trlr. 5583 2q j(4) ASBESTOS Computer Ref. w-1198 Date July 17, 1981 cc; c. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 H. L. Robinson , 701-401 E. C. Shipley, 511-2009 E. J. Tawney, Trlr. 5583 PERSON MONITORED M. D. Coleman Location EXPOSURE RESULTS West end of Bldg. 774, behind Date the parking lot to south end of parking lot 07/10/81 Sample No. Cone. fibers ^ 1 .3 >5 p.m/cmc fibers ^ 2 .3 >5 |i.m/cmc 3 Sampling Time 159 Minutes 152 Minutes Comments A.M. - bagging stripped insulation P.M. - bagging stripped insulation 4 5 6 Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 p.m/cm^ Ceiling COMMENTS x OSHA OSHA _____UCC UCC ____Other Other Ruth Clise APPROVED BY UCC 016627 Manhar A. Patel j UNION j BUSINESS I CARBIDE J CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR ______ASBESTOS TO: R. F. Painter , Trlr. 5583 Computer Ref. W-1198 Date July cc: C. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, Trlr. 5583 PERSON MONITORED B. J. Agosti Location EXPOSURE RESULTS West end Bldg. 774 behind parking lot to south end. ol parking lot Date 07/10/81 Sample No. 1 2 3 Cone. fibers .5 >5 pm/cm 3 fibers 4 >5 jim/cm 3 Sampling Time Comments 149 Minutes A.M. - stripping insulation 156 Minutes P.M. - stringing insulation 4 5 6 Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 tim/cm^ Ceiling - X OSHA OSHA COMMENTS ____UCC UCC ____Other Other WORK BY t7/. Ruth Clise APPROVED BY UCC 016628 Manhar A. Patel BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: R. F. Painter, Trlr. 5583 ASBESTOS Computer Ref. W-1198 Date July 17, 1981 cc; c. W. Carman, 725-105 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 R. E. Peele, 701-334 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, Trlr. 5583 PERSON MONITORED _______________________ R. E. Templeton Location EXPOSURE RESULTS West end Bldg. 774 behind______ Date parking lot to south end of ParkinS lot 07/10/81 Sample No. 1 2 Cone. fibers , .2 >5 gm/cm* ! fibers _ .2 >5 um/cm* 3 Sampling Time 148 Minutes 155 Minutes 4 5 6 Comments A.M. - bagging insulation P.M. - bagging insulation Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 um/cm^ Ceiling COMMENTS X OSHA ____OSHA UCC UCC Other Other WORK BY Ruth Clise APPROVED BY UCC 016629 Manhar A. Patel XJ INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX 8361, SOUTH CHARLESTON, WV 25303 To iNa-Tie) d. son Loosrcn W. L. Browning J. W. Perry, Jr. Institute Plant Date October 23, 1981 ar3,r,atnSn,,D. IH/EP coo, _o -- C. W. Carman , M. L. -p Mil Is rr-m L. R.-Noble il D. R. Paugh R. E. Peele H. H. Frazier R. J. Sexton, M.D. F. Williams s-c-aAsbestos Monitoring in Gasket Shop, 512 Construction Gentlemen: In my letter of October 20, 1981, concerning asbestos monitor ing in the Gasket Shop - 512 Construction, an error was made due ' to misinterpretation of the data we received from the 512 Industrial Hygiene group. Please replace the letter dated October 20, 1981 from your file with the one attached to this note. Very truly yours, A .fLkl Manhar A. Patel MAP/sc Attachment UCC 016630 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX B3B1, SOUTH CHARLESTON, WV 25303 Toita^ei W. L. Browning o-j. w. Perry, Jr. Institute Plant c3-.e October 23, 1981 Si ar-Bo^ct IH/EP C. W. Carman M. L. Mills L. R. Noble D. R. Paugh R. E. Peele H. H. Frazier R. J. Sexton, M.D. F. Williams Asbestos Monitoring in Gasket Shop, 512 Construction (Replaces letter of October 20, 1981 - front page only.) Gentlemen: Attached are the results of the area and personal exposure monitoring done for asbestos in the Gasket Shop - laundry, Building 3 of the Construction Department, Institute Plant. This monitoring was done by the Institute Plant Industrial Hygiene group on October 2, and 9, 1981. The gasket cutting is done infrequently and it would generally last for a short period of time. The results of the survey indicate that the asbestos exposure in excess of the permissible limit of 2 fibers per centimeter cube of air did not occur. The workers did not wear a respiratory protective device while working with the gasket material. It is emphasized that all workers wear a disposable 3M #8710 dust respirator which is approved by NIOSH for protection from asbestos exposure. Please notify the monitored workers of their exposure results. If I can be of further assistance, please give me a call at extension 3750. Very truly yours, rl--X-(ZM Manhar A. Patel MAP/sc Attachment UCC 016631 l^JcONHDINllAl ASBESTOS MONITORING CONSTRUCTION GASKET SHOP INSTITUTE PLANT # Name/Area Monitored 1 F. M. Hatfield 2 3 Feet from cutting blade 3 F. M. Hatfield 4 3 Feet from cutting blade Date 10/2/81 10/2/81 10/9/81 10/9/81 Sampling Time Minutes Asbestos Cone. Fibers >5 nm/cm3 18 < 0.1 17 < 0.1 15 0.4 15 0.2 / UCC 016632 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX 0361, SOUTH CHARLESTON, WV 25303 tc ,.,on L=ra-. W. L. Browning J. W. Perry, Jr. Institute Plant O^'gioatir October 20, 1981 TH/EP Ccc C. W. Carman M. L. Mills L. R. Noble D. R. Paugh R. E. Peele H. H. Frazier R. J. Sexton, M.D. F. Williams Asbestos Monitoring in Gasket Shop, 512 Construction Gentlemen: Attached are the results of the area and personal exposure monitoring done for asbestos in the Gasket Shop - laundry, Building 3 of the Construction Department, Institute Plant. This monitoring was done by the Institute Plant Industrial Hygiene group on October and 9, 1981. 2, The gasket cutting is done infrequently and it would generally last for a short period of time. The results of the survey indicate that the asbestos exposure in excess of the permissible limit of 2 fibers per centimeter cube of air did not occur. The workers wore a respiratory protective device while working with the gasket material. It is emphasized that all workers continue to follow this practice while working in the area during gasket cut ting. Please notify the monitored workers of their exposure results. If I can be of further assistance, please give me a call at extension 3750. Very truly yours, MAP/sc Attachment Manhar A. Patel UCC 016633 ASBESTOS MONITORING CONSTRUCTION GASKET SHOP INSTITUTE PLANT Name/Area Monitored Date Sampling Time Minutes Asbestos Cone. Fibers >5 iim/cnr* F. M. Hatfield 10/2/81 18 < 0.1 3 Feet from cutting blade 10/2/81 17 < 0.1 F. M. Hatfield 10/9/81 15 0.4 3 Feet from cutting blade 10/9/81 15 0.2 UCC 016634 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter, 5583 (511) Computer Ref. 1064 CC: C. W. Carman, 725-105 D. H. Cook, 5583 (511) G. F. Hurley, 701-334 :L;Sl.SolSe^"i1S2il9 '*$. c. Shipley, D. R. Paugh, 511-2009 H. L. Robinson, 701-401 PERSON MONITORED D. C. Shamblin Location EXPOSURE RESULTS Basement of Bldg. 789 (Cooling Tower) Date 7/3/80 Sample 1 2 3 4 5 ,6 Cone. . fibers >c .7 pm/cm3 Sampling Time 108 minutes Comments A.M. Sample - Stripping insulation * P.M. Sample - Stripping lnsuxa llun Time-Weighted Average Concentration (TWA) Not Calculated Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 jim/cm3 Ceiling __________________' (oSHSq OSHA UCC UCC Other Other COMMENTS Because part of the insulation being stripped was believed to contain asbestos, the workers in the area still are required to wear disposable dust masks and keep the insulation to be stripped well wetted. Barricades and signs must be present to warn others in the area of the potential hazard. In the future, when there is doubt aboul the insulation containing asbestos, either full precautions for handl ing asbestos will be observed or a sample of the insulation will be tested fonoasbestos content prior to starting the job. WORK BY _____________________________ APPROVED BY *The P.M. sample could not be %.na.lyzed because it got wet. UCC 016635 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter , 5583 (511) Computer Ref. 1064 CC: c. w '. Carman, 725-105 D. H. Cook, 5583 (511) G. F. Hurley, 701-334 LiH^toBle^511-2149 a E. C. Shipley, 512 H. L. Robinson, 701-401 PERSON MONITORED C. Miller Location EXPOSURE RESULTS Basement of Bldg. 789 (Cooling Tower) Date 7/3/80 Sample 1 2 3 4 5 6 Cone. . "--iTffSFS'TS .3 pm/cm^ Sampling Time 108 minutes Comments A.M. Sample - Stripping insulation * P.M. Sample - Stripping Insulation Time-Weighted Average Concentration (TWA) Not Calculated Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 pm/cm^ Ceiling OSHA UCC UCC Other Other COMMENTS Because part of the insulation being stripped was believed to contain asbestos, the workers in the area still are required to wear disposable dust masks and keep the insulation to be stripped well wetted. Barricades and signs must be present to warn others in the area of the potential hazard. In the future, when there is doubt about the insulation containing asbestos, either full precautions for handling asbestos will be observed or a sample of the insulation will be tesstteecdU^^ffoorr asbestos ccoonntent prior to starting the job. WORK BY ____ APPROVED BY *The P.M. sample could not be analyzed because it got wet. UCC 016636 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter, 5583 (511) Computer Ref. 1064 rr. C. W. Carman, 725-105 D. H. Cook, 5583 (511) G. F. Hurley, 701-334 L^VR,,.;Hobley>-;51Xr2149 | T5. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 512 PERSON MONITORED R. R. Burgess Location EXPOSURE RESULTS Basement of Bldg. 789 (Cooling Tower) Date 7/3/80 Sample 1 2 3 4 5 6 Cone. fibers > 5 . 3 Lim/cm^ Sampling Time 90 minutes Comments A.M. SamDle - Bageine StriDDed Insulation * P.M. Sample - Bagging Stripped Insulation Time-Weighted Average Concentration (TWA) Not Calculated Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 jim/cm3 Ceiling _______________________ (jDSHg) OSHA UCC UCC Other Other COMMENTS Because part of the insulation being stripped was believed to contain asbestos, the workers in the area still are required to wear disposable dust masks and keep the insulation to be stripped well wetted. Barricades and signs must be present to warn others in the area of the potential hazard. In the future, when there is doubt about the insulation containing asbestos, either full precautions for handling asbestos will be observed or a sample of the insulation will be testteedds^&oorr asbestos ccoonntent prior to starting the job. WORK BY* * APPROVED BY l*The P.M. sample could not be (analyzed because it got wet UCC 016637 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter , 5583 (511) Computer Ref. W-1078 CC: C. W. Carman, 725-105 D. R. Paugh, 511-2009 G. F. Hurley, 701-334 H. L. Robinson, 701-401 L. R. Noble,. 511-2149 3 E. C. Shipley, 511-2009 E. J. Tawney, 558 PERSON MONITORED ___________________R. E. Templeton Location EXPOSURE RESULTS Bldg. 777 - Between easteipfete 8/25/80 of aOR Unit ana Dewatering ShH on second level of elevator shaft Sample 1 2 3 Cone . ibers > 0.2 (im/cm3 < 0.1 Sampling Time 68 minutes 73 minutes Comments A.M. P.M. Sample - Bagging insu la non Sample - Bagging ------------------ insulation and cleaning area 4 5 6 Time-Weighted Average Concentration (TWA) <0.1 fibers >5 gm/cm3 Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 gm/cm^ C/oshZ^ Ceiling _______________________ OSHA ucc UCC Other Other COMMENTS . Stripping was done outside and it was very well wetted by rain. WORK BY APPROVED BY UCC 016638 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter , 5583 (511) Computer Ref. W-1078 CC: C. W. Carman, 725-105 G. F. Hurley, 701-334 L. R. Nobley 511-2149 D. R. Paugh, 511-2009 H. L. Robinson, 701-401 >E. C. Shipley, 511-2009 E. J. Tawney, PERSON MONITORED D. C. Shamblin Location Bldg. 777 - Between eastenSate 8/25/80 of ACR Unit and Dewatering She'S EXPOSURE RESULTS on second level of elevator shaft Sample 1 2 3 4 5 .6 Cone. fibers 0.1 gm/cm3 Sampling Time . o 71 minutes 0.2 " 64 minutes Comments A.M. - Stripping insulation P.M. - Stripping insulation Time-Weighted Average Concentration (TWA) <0.1 fibers >5 pm/cm^ Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 nm/cm^ Ceiling ________________ 0SHA__^ OSHA UCC UCC Other Other COMMENTS Stripping was done outside and it was very well wetted by rain. UCC 016638A oo INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter, 5583 (511) Computer Ref. W-1078 C. W. Carman, 725-105 G. F. Hurley, ,,701-334 L. R. Noble, 511-2149^ D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, PERSON MONITORED C. Miller Location EXPOSURE RESULTS Bldg. 777 - Between easteriBP-te _____ of ACR Unit and Dewatering Shed on second level of elevator shaft 8/25/80 Sample 1 2 3 Cone. fibers ; 5 0.1 |im/cm3 < :o.i " Sampling Time 74 minutes 63 minutes Comments A.M. P.M. Sample Sample - Stripping Insulation Stripping Insulation 4 5 .6 O Time-Weighted Average Concentration (TWA) <0.1 fibers >5 pm/cm Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 pm/cm3 dpSH^) Ceiling _______________________ OSHA UCC UCC Other Other COMMENTS . Stripping was done outside and it was very well wetted by rain. UCC 016639 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter, Trlr. 5583 511 Computer Ref. W-1076 CC: c. W. Carman, 725-105 D. R. Paugh, 511-2009 G. F. Hurley, 701-334 iH. L. Robinson, 701-401 L. R. Noblej/4511-2149 ... 3e. C. Shipley, 511-2009 E. J. Tawney, 5583 R. G. Rowe, M.D. , 7 PERSON MONITORED R. E. Templeton Location Bldg. 777 - Room 111 Date 8/19/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. fibers > 10.1 5 jim/cm 3 Sampling Time 118 minutes Comments P.M. - Wetting and bagging insulation and cleaning up area Time-Weighted Average Concentration (TWA) 2.5 fibers > 5 pm/cm3 Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm3, (^OSHaJ) UCC Ceiling _______________________ OSHA UCC Other Other COMMENTS , Even though the workers had been advised to keep the insulation well wetted, it didn't appear as if they had done so. UCC 016640 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter, Trlr. 5583 511 Computer Ref. W-1075 CC: C. W. Carman 725-105 G. F. Hurley. 701-334 l. r. Noble; 511-2149"' - ,.T.d D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, 5583 R. G. Rowe, M. D. , PERSON MONITORED R. E. Templeton Location Bldg. 777 - Room 111 Date 8/18/80 EXPOSURE RESULTS Sample 1 2 3 4 5 .6 Cone. ixceri . > 6.3 5 gm/cm * Sampling Time 42 minutes Comments " A.M. - Wetting and bagging insulation 3.9 " 149 minutes P.M. - Wetting and bagging insulation and cleaning up area Time-Weighted Average Concentration (TWA) 2.8 fibers > 5 am/cm3 Ceiling Concentration ________________ ALLOWABLE EXPOSURE TWA 2 fibers > 5 |im/cm3 (jOSHA^) UCC Ceiling _______________________ 0SHA UCC Other Other COMMENTS , More water needs to be used in keeping the insulation wetted. Disposable dust respirators should be worn while in the stripping area and until the cleanup is completed. WORK BY APPROVED BY UCC 016641 B. E. Bess, 514 P. W. Young, 512 L. R. Noble,- 512 -- * H. L. Robinson, 511 E. C. Shipley, 512 F. Williams, 512 September 12, 1980 IH/EP Asbestos Exposure Monitoring Gentlemen: Asbestos monitoring in the SEVIN operations area on Septem ber 3, 1980 showed an air concentration of 0.1 fiber per cc which is well below the present OSHA standard. Six samples of breathing zone air were taken on Messrs. D. R. Smith, J. F. Sampson and P. D. Coyner. Due to an error in analyti. cal procedure only one valid sample, that for Mr. Smith, was obtained. Since all the recommended procedures for stripping asbestos-containing insulation were followed it is felt that the 0.1 result obtained represents the breathing air concentration in the ambient air. Please give the people sampled the results. The actual sam pling was done by members of Fred William's Industrial Hygiene group at Institute. Very truly yours, GFH/sc G. F. Hurley UCC 016642 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter , Trlr. 5583 511 Computer Ref. W-1076 CC: C. W. Carman, 725-105 G. F. Hurley, ,701-334*. L. R. Noble,..511-2149 D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E. J. Tawney, 5583 R. G. Rowe, M.D., PERSON MONITORED ________________ D. C. Shamblin__________________________ Location Bldg. 777 - Room 111 Date 8/19/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Sampling Cone. ________Time________ fibers > 14.4 5 gm/cm 3 125 minutes Comments P.M. Stripping insulatior and cleanup of area. Time-Weighted Average Concentration (TWA) 3.8 fibers > 5 gm/cm^ Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 um/cm^ (OSHA^? UCC Ceiling OSHA UCC Other Other COMMENTS The concentration of fibers was as great the second day even though the men had been advised to keep the insulation well watered. WORK BY APPROVED V 7 UCC 016643 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: R. F. Painter , Trlr. 5583 511 Computer Ref. W-1075 CC: c. W. Carman, 725-105 G. F. Hurley, 701-334 L. R. Noble, 511-2149..1 D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 E Tawney, 5 R. G. Rowe, M.I 75c PERSON MONITORED D. C. Shamblin Location Bldg. Ill - Room 111 Date 8/18/80 EXPOSURE RESULTS Sample 1 2 3 4 5 .6 Cone. fibers > 15.4 5 um/cE l3 Sampling Time Comments 41 minutes A.M . Stripping insulation 11.3 " 149 minutes P.M . Stripping insulation and helping with cleaning of area Time-Weighted Average Concentration (TWA) 4.1 fibers > 5 um/cm3 Ceiling Concentration ________________ ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm^ (oSHA Ceiling __________ OSHA UCC UCC Other Other COMMENTS More water should be used to wet the insulation before stripping. Those stripping and bagging should always wear their disposable dust respirator while in the area and until the cleanup is finished. WORK BY APPROVED BY UCC 016644 oC 149*2 INTERNAL CORuESrOf'DSNCE C-5 AGRICULTURAL PRODUCTS CO.nPA^Y, ?M. '/si'Cs 9 P.0. BOX 2831, CHARLESTON, WEST VIRGINIA 25: INSTITUTE PLANT To (Name) Division Location Mr. G. F. Hurley Building 701/334 Technical Center Floor Nu nber Date January 5, 1981 originating Dept. Industrial Hygiene Floor Number Copy to Mr. A. S. Howard Mr. L. R. Noble-""' Mr. H. L. Robinson Dr. R. J. Sexton Mr. E. C. Shipley Mr. F. Williams Answering letter date Subject Asbestos Exposure Monitoring Monitoring for personal exposure to asbestos at the No. 1 Steam Plant on December 12, 1980, showed a maximum airborne level of 4.1 fibers per cc of air. Twelve 511 Construction insulators and laborers were measured for 15 minute sample periods over a time period of 150 minutes. Two results (see attached data sheet) were at or above the present OSHA standard of 2.0 fibers per cc of workplace air. This monitoring occasion was scheduled during peak activity of demolition of asbestos material from No. 6 boiler at operating floor level. A minimum number of Plant 512 employees were in the area at the time work was in progress. The area was properly barricaded, signs in place and vM Construction employees involved in the demolition process wore MSA Dust Foe A\y \ ~3*77 or 3M Model 8710 dust masks. Material being demolished was generally wet down but some dust was generated from the interior surfaces. Laborers bagged the material for disposal as the project progressed, This demolition of asbestos material was carried out according to acceptable guidelines and airborne material was maintained generally at permissible levels. Future jobs of similar nature need to be performed in a like manner and continued use of respiratory protection be required. Please inform the above participating employees of their individual monitoring results. / HHF:me Attachment H. H. Frazier UCC 016645 INDUSTRIAL HYGIENE SAMPLING WORKPLACE LOCATION: No. 1 Steam Plant CONTAMINANT: Asbestos DATE: 12/29/80 NAME: J. L. Miller BUILDING: 5 OSHA TLV 2 f/cc ' ' /2l OAJ/ sf6-~ -B-. -E. Begs-;--514 // #\//U> -P-, W.--Young, 512^ ^ ^ L. R. Noble, 512 H. L. Robinson, 511 E. C. Shipley, 512 F. Williams, 512 September 12, 1980 IH/EP Asbestos Exposure Monitoring Gentlemen: Asbestos monitoring in the SEVIN operations area on Septem ber 3, 1980 showed an air concentration of 0.1 fiber per cc which is well below the present OSHA standard. Six samples of breathing zone air were taken on Messrs. D. R. Smith, J. F. Sampson and P. D. Coyner. Due to an error in analyti cal procedure only one valid sample, that for Mr. Smith, was obtained. Since all the recommended procedures for stripping asbestos-containing insulation were followed it is felt that the 0.1 result obtained represents the breathing air concentration in the ambient air. Please give the people sampled the results. The actual sam pling was done by members of Fred William's Industrial Hygiene group at Institute. Very truly yours, GFH/sc G. F. Hurley UCC 016647 *&. `i!eSSb~' >" , &U" '''*' INDUSTRIAL hygiene monitoring for ... * .-V ^ '. . - ' j-' y :' -`-.vv. TO: D. L. Johnson - ; - i,-\ ASBESTOS Computer Ref. W-1040 : cc: C. W. Carman, G. F. Hurley, C. R. Johnson TgWuKi. D. R. Paugh, > a-V PERSON MONITORED i-% : .r.f ... . . . Location. EXPOSURE RESULTS . L. Robinson, 701-401 E. C. Shipley, 511-2009 D. K. Naylor #1 Powerhouse Institute Date 4/11/80 ... t ... . . - / .f. / 2 /' ` . 3 4 5 6 Sampling Cone. Time fibers . r . .35 5 um/cm; 1 60 minutes fibers : . 81-'5 pm/cm- ! 105 minutes _ fibers : .18 5 um/cm; * 87 minutes fibers 1 .. 06 5 iim/cm1 * 49 minutes Comments A.M. - Bagging insulation A.M. - Bagging insulation P.M. - Bagging insulation P.M. - Bagging insulation cleaning area . Time-Weighted Average Concentration (TWA) 0.3 fibers > 5 um/cmv Ceiling Concentration /|f|^ALLOWABLE EXPOSURE TWA 2 fibers > 5 um/cm3 Y^sij) Ceiling _____________ ' OSHA UCC UCC Other Other COMMENTS Bagging insulation that had been stripped from #2 boiler front and /boiler front duct on second level of #1 Powerhouse at Institute. ,, , NfiCr* Nkylor fmpre a disposable Norton dust respiratory and disposable vS^^fcbweriils-dufing the bagging and cleanup. The insulation was placed plastic bags for disposal and dropped from the second level to a - truck: below.'>At'this point the full bags should be handled carefully. ^ It is suggested that they could be lowered on a rope to prevent the bags from splitting. fQRK BY L<UL BY-1 i-,r. ,,** :; .. ' /' % UCC 016648 A"*#- -" INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: D. L. Johnson, 511-5518 'ilfer '- Computer Ref. w-1040 - hycci . C. V. Carman, 725-105 G. F. Hurley, 701-334 C. R. Johnson, 511-2009 D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED G. H. Landers Location #1 Powerhouse - Institutd)ate 4/11/80 ' EXPOSURE 'RESULTS Sample 1 ft JfS'--".i. C- 2 3 ' . . 4 Cone. fibers > . 35, 5 pm/cm3 fibers > .42 5^jim/cm3 Sampling Time 60 minutes 105 minutes fibers > .09 5 um/cm3 80 minutes fibers > .65 5 um/cm3 38 minutes *> :v^ ; : > ':r \ *Arr. ; ~ 56 A.M. - Stripping insulation A.M. - Stripping insulation P.M. - Stripping insulation P.M. - Strinning insulation cleaning area. .Time-Weighted Average Concentration (TWA) 0.2 fibers > 5 qm/cm^ f - Ceiling Concentration % ,, or 4 ALLOWABLE EXPOSURE 5n TWA 2 fibers > 5 um/cm3 <$SHA> Ceiling OSHA UCC UCC Other Other COMMENTS* U Stripping susjpected asbestos containing insulation from #2 boiler front and boiler front duct on second level of #1 Powerhouse at Institute. The last sample of the day was the highest concentration found. This be atftribu^ed to the fact that they got in a hurry and didn't keep %:7': the insulation well'wetted. Mr. Landers wore a disposable Norton dust respirator, and disposable coveralls during the stripping. i WORK BY PPROVED BY UCC 016649 fe$\5V`\V;V.;#^A.v ..-. INDUSTRIAL HYGIENE MONITORING FOR f\ 1 D L. Johnson, 511-5518 ASBESTOS Computer Ref. W-1041 ;C* W. Carman, 725-105 G. F. Hurley, 701-334 C. R. Johnson, 511-2009 D R. Paugh, 511-2009 P. A. Perrj H. L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED D. K. Milan Location #1 Powerhouse - Institu-ff&te 4/11/80 EXPOSURE RESULTS Cone. fibers 69 5 qm/cm* fibers 2.72 5 nm/cm * Sampling ___IlS&____ 68 minutes 27 minutes Comments P.M. - Stripping insulation P.M. - Stripping insulation " ,\*.-rj.:.f'***'/; -- , Time-Weighted Average Concentration (TWA) Not monitored long enough isi&V'r Ceiling Concentration to calculate TWA. ^ C^I allowable exposure * y: - ..... ....... . _____ , k^sT TWA 2 fibers > 5 um/ern^ ^OSHA) Ceiling 0SHA UCC UCC Other Other doMMENTS Stripping insulation from #2 boiler front and boiler front duct on second level of #1 Powerhouse at Institute. Mr. Milan wore a disposable Norton respirator;\and disposable coveralls during the stripping. The f?^^liJSulatorsf got ih a hurry toward the end of the day and didn't keep the insulation well wetted. This resulted in the last value being higher. /? isWtOVED BY 1 VAv 7 UCC 016650 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: D. L. Johnson, 511-5518 Computer Ref. w-1040 imm:- CC: J 4$- ^ ^ 7I' ` 'v C. W. Carman, 725-105 G. F. Hurley, 701-334 C. R. Johnson, 511-2009 D,, R. Paugb, 511-2009 L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED B. Beckett Location EXPOSURE RESULTS #1 Powerhouse Institute Date 4/11/80 aT1 fr:'-~ mmmi . . ** Sample .' 1^ 2 Sampling Cone. fibers , > Time .48 5 um/cm * 60 minutes fibers i > 1.24'-5 um/cm *84 minutes . *. ~ - t . 3 ;/ 4 wM Comments A.M. - Stripping insulation A.M. - Stripping insulation .6 Time-Weighted Average Concentration (TWA) Not monitored long enough Ceiling Concentration to calculate TWA. ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cmv Ceiling ________________ LOSI OSHA UCC UCC Other Other ^^J^Stxipping sqppected asbestos containing insulation from #2 boiler front ?^^^4'andholler''.^ont.^iict on second level of #1 Powerhouse at Institute. Mr. Beckett ^s not monitored in the afternoon because he was trans'^^^^.^Perjced %o another job. During the stripping he wore a disposable Norton 'irV^V*>J- dust -vrtAeasMp-jiitrna+AtoMr nann/4d ^d^ isposaKb1lea acaovoetroalilels. ' UC 149-2 INTERNAL CORRESPONDENCE S2fo*// S'C'CsaS Cm- AGRICULTURAL PRODUCTS COMPANY INC. P.0. BOX 2831, CHARLESTON, WEST VIRGINIA 25 . INSTITUTE PLANT To (Name) Mr. G. F. Hurley Division Building 701, 334 Location Technical Center Floor Number Date July 25, 1980 Originating Dept. Industrial Hygiene Floor Number Copy to Mr. Mr. Mr. Mr. -^Mr. Dr. Mr. Mr. K. B. Drake S. E. Illikainen A. S. Howard S. w. Jensen L. R. Noble R. J. Sexton E. C. Shipley Fred Williams Answering letter date Subject Asbestos Exposure Potential, Precipitators, No. 1 Steam Plant Concern has been expressed on various occasions relative to the condi tion of protective covering over asbestos containing insulation on the south side of the No. 1 Steam Plant precipitators. A recent storm apparently caused large sections of the protective cover to be torn from the precipitators, leaving some sections free to move according to wind direction and elocity. Industrial Hygiene was requested to evaluate the existing conditions in terms of personal exposure potential of personnel involved in the 511 Construc tion Project of retubing the boilers. By observation, the condition appeared to have serious potential and it was suggested to Mr. Jensen that "freehanging" protective cover be removed and consideration be given to application of a binder material to the exposed insulation. Sampling at appropriate locations and personal sampling of selected workers for asbestos exposure was initiated to determine the degree of the apparent problem. The current OSHA Standard for asbestos sets an eight-hour time-weighted average airborne concentration to which any employee may be exposed not to exceed two fibers, longer than 5 micrometers, per cubic centimeter of air. A ceiling concentration of 10 fibers has been established which is not to be exceeded for any time period. Samples collected at this location on July 21, 1980, show results as follows: Name/Type Sample Fibers/cm^ Job Task/Location D. R. Stephens W. P. Gilmore S. J. Edens 1.8 0.08 0.09 Rigger inserting piping in. tube: sheet. 3rd level. Rigger guiding tubes into tube sheet. 4th level. Rigger guiding tubes into tube sheet. 4th level. UCC 016652 Mr. G.. F. Hurley -2- July 25, 1980 Naine/Type Sample Fibers/cm^ Job Task/Location B. J. Wehrle Area Area Area Area Area Area 0.05 0.05 0.09 None detected None detected None detected 0.05 Rigger inserting piping in tube sheet. 3rd level. Face level No. 3 boiler (upwind) while pipe was inserted. Face level No. 3 boiler (downwind) while piping was inserted. South of No. 6 precipitator at source undisturbed by workers. South of No. 4 precipitator at source undisturbed by workers. South of No. 1 boiler while scaffold was eracted at No. 3 (downwind). South of No. 2 boiler while scaffold was erected at No. 3 (dow'nw'ind) . These data indicate that exposure potential to airborne asbestos is minimal from the large areas of exposed insulation material on the south side of the precipitators when the material is undisturbed. The four personal samples were collected during a time period when tubes were being inserted into the north side of the tube sheet and local disturbance of the insulation material was near a maximum. The extreme north tubes require manipulation of the piping against the insulation and it was observed that pieces of insulation up to hali inch diameter were being released into the work area. Individual fibers, which are the real hazard, were not being released at the expected rate nor at an excessive degree. Industrial Hygiene, therefore, recommends the following: 1. Energy Systems follow-up on a Maintenance request to remove all "freehanging" protective covering which can be safely removed without scaffolding. Personnel involved should wear a 3M dust mask and the Insulation side of the removed covering should be wet down for immediate disposal. 2. Plant 511 Construction personnel should continue to wear 3M dust masks while inserting tubes in the north side of the respective tube sheets and/or while raw insulation is being disturbed. 3. At the discretion of the Construction supervision, a sealer may be applied at local areas of exposed insulation proximal to where work is to be performed and insulation is likely to be disturbed. Should there be questions or need for additional monitoring, please call me at 6161. H. H. Frazier UCC 016652A MEMO TO___ AVOID ORAL INSTRUCTIONS /JjAz-c-kX. ' 197 %0 + DO IT THE SAFE WAY HH SIGNED UCC 016653 INTERNAL CORRESPONDENCE ~7 CHEMICALS AND PLASTICS To (Name) Division location Mr. D. L. Johnson 511-5518. Institute Plant Mr. Mr. Mr. Mr. Mr. Mr. Mr. Mr. C. W. Carman G. F. Hurley C. R ...-Johnson. L.,,R.i Noble ^ D. R. Paugh P. A. Perry H. L. Robinson E. C. Shipley P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Date January 22, 1980 Originating DePtTechnical Center IH/EP Asbestos Monitoring - No. 1 Powerhouse, Institute Plant PROJECT Determine the exposure of Construction employees to asbestos during the stripping of old insulation from #1 boiler at the #1 Powerhouse, Location 512. DATE OF SURVEY January 15, 1980 SUMMARY Although asbestos exposures to employees were higher than normal, the use of approved respirators and protective clothing as well as proper stripping and disposal procedures protected the workers from a potentially hazardous situation. DISCUSSION Construction insulators are in the process of stripping several thousand feet of old asbestos type insulation from the steam boilers at the #1 Powerhouse, Location 512. The job will be in progress for the next two years and will involve many crafts before completion. The area to be stripped was doing the work were protected by disposable coveralls and gloves. hats while in this area. barricaded, labeled and persons the use of approved respirators, They are required to wear hard UCC 016654 2- - Four personal samples were collected as well as area samples on the first three floors of #1 boiler, north side. The results are listed in the attached "RESULTS". Although the results of two personal .samples are greater than the OSHA standard of 2 fibers, the workers were protected. RECOMMENDATIONS 1. Bags of stripped insulation should be handled carefully, not dropped from one level to another. 2. Cleanup should be thorough and inspected by Construction supervisor for completeness. Complaints can be easily generated by powerhouse employees or other workers in the area. 3. Protective clothing should be discarded in plastic bags along with the insulation. REFERENCES Volume 38C-29X4-Rla Asbestos, Dust Determination by Membrane Filter Technique Using Phase Contrast Microscopy REPORT PREPARED BY G. W. Bott Technical Center Industrial Hygiene Group .&rv. /Sd&r- APPROVED BY F. HuaivLey GWB/sc Attachment /j UCC 016655 RESULTS DATE SAMPLE TYPE 1/15/80 G.H. Landers 1/15/80 M.E. Drake 1/15/80 J.F. Chandler 1/15/80 T.G. Grant 1/15/80 Third Level 1/15/80 Second Level 1/15/80 First Level TIME (MIN.) 60 60 60 45 70 60 72 ASBESTOS FIBERS FOUND 4.4 3.2 1.5 1.6 0.4 0.8 0.03 TWA REMARKS 3.3 Stripping insulation 2.4 Laborer 1.1 Stripping insulation 1.2 Laborer - Directly above work area - Center of work area - Directly below work area TWA was calculated assuming that stripping was done for six hours out of eight. UCC 016656 INTERNAL CORRESPONDENCE CHEMICALS AND PLASTICS P. 0. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 o (Name) division ocation Icpy to Mr. D. L. Johnson 511-5518 - Institute Plant Mr. G. F.^urlev Mr. L. R. Noble I Mr. H. L. Robinson Mr. E. C. Shipley Mr. E. J. Tawney ~<> `//so/so April 9, 1980 )r,g nat ng Depi Technical Center IH/EP ;ob:pet Asbestos Monitoring at Institute #1 Powerhouse PROJECT Monitor employee exposure to airborne asbestos fibers during removal of insulation from the 2 boiler in the #1 Powerhouse at Institute. DATE OF SURVEY April 3, 1980 DISCUSSION Four Construction employees, three insulators and one laborer, removed insulation from boiler #2 on the third level in the Institute #1 Powerhouse. All employees wore disposable coveralls, gloves and respirators. The insulation was wetted before and during removal and the area was barricaded. Ah insulator, Mr. B. M. Beckett, and a laborer, Mr. R. D. Ward, wore personal samplers during the removal and bagging operations. The air concentrations of the four samples taken ranged from 0.17 to 0.41 fibers per cubic centimeter of air (f/cc). Since there was no other exposure to asbestos the rest of the day, the eight-hour time-weighted average (TWA) exposures were 0.06 and 0.07 f/cc. The OSHA permissible exposure limit for an eight-hour TWA is 2 f/cc. DATA (Continued on next page) UCC 016657 2 4/9/80 DATE 3/3/80 3/3/80 3/3/80 3/3/80 SAMPLE B.M. Beckett B.M. Beckett R. D. Ward R.D. Ward SAMPLING TIME 0825-0945 1010-1053 0825-0945 1010-1110 AIR CONC. (f/cc) 0.23 0.41 0.17 0.26 TWA (f/cc) - 0.07 - 0.06 REPORT PREPARED BY W. F. Blythe, Jr. WFBJr/sc UCC 016658 ron'EsroNDHiiC: Mr. Mr. Mr. Mr. Mr. J. Byrd G.. F. .Hurley L. R. Noble H. L. Reveal H. L. Robinson c29(u/) 33d',. 3GUTH CHARLESTON, WEST VIRGINIA 25303 us-, February 6, 1979 c. . r,v r Ce,,. Technical Center IH/EP Asbestos Monitoring at Sevin Shipping INTRODUCTION On January 22, 1979, Messrs. C. C. Bragg and C. R. Lanier were monitored for exposure to asbestos during the removal of insulation from the flanges of a pipe line in Building 233, the Sevin Shipping area. SUMMARY AND CONCLUSIONS The asbestos concentrations in the breathing zones of the insulators were 7.75 and 5.37 fibers/cc while an area sample indicated a concentration of 0.3 fibers/cc. Both men wore respirators during the entire operation, but facial hair on each man possibly prevents an adequate seal. The OSHA ceiling limit for asbestos is 10 fibers/cc. The OSHA standard for an eight-hour time-weighted exposure is 2 fibers/cc. Due to the short exposure time (25 minutes), the insulators' TWAs would not exceed the OSHA standard without further exposure. However, in future operations where large amounts of water cannot be used to reduce emission of air borne asbestos fibers, a garden sprayer might be used since a finer spray and smaller volumes of water can be used. DISCUSSION Mr. C. C. Bragg and Mr. C. R. Lanier wore per sonal samplers while removing insulation from the flanges of a pipe line in Building 233. Due to the storage of Sevin directly under the pipe line being worked on, the insu lation could not be watered down during removal. Both men wore respirators. One man stripped the insulation while the other held a plastic bag directly under the flange to catch the insula tion. The effectiveness of this procedure in keeping down airborne asbestos dust in the surrounding area was indicated by a sample taken eight feet below the first flange which showed a concentration of 0.3 fibers/cc. The personal samples indicated concentrations of 7.75 fibers/cc and 5.37 fibers/cc for a twenty-five-minute exposure. Further exposure was minimal since the pipe was to be UCC 016659 2 dismantled at the flanges and taken outside where it could be wetted with water before, during, and after removal. DATA Date 01/22/79 01/22/79 01/22/79 Sample C. C. Bragg C. R. Lanier Area Sample below first flange Sampling Time 0855 - 0920 0855 - 0920 0855 - 0920 Air Cone. Fibers/cc 7.75 5.30 0.30 REFERENCES (1) UCC C/P Industrial Hygiene Method 38C-29X4-Rla (2) 29 CFR 1910.1001 REPORT PREPARED BY W. F. Blythe, Jr. Technical Center Industrial Hygiene Group WFBJr/sc UCC 016660 ':e: l co::'.Lsro: Mr. J. Byrd Mr. G. F. Hurley Mr. L. R. Noble Mr. H. L. Reveal Mr. H. L. Robinson charleston. WEST VIRGINIA 25303 February 6, 1979 Technical Center IH/EP Asbestos Monitoring at Sevin Shipping INTRODUCTION On January 22, 1979, Messrs. C. C. Bragg and C. R. Lanier were monitored for exposure to -evC* asbestos during the removal of insulation from the flanges of a pipe line in Building 233, the Sevin Shipping area. 1MARY AND COI^CLUSIONS The asbestos concentrations in the breathing . zones of the insulators were 7.75 and 5.37 fibers/ccN^hilb^ an area sample indicated a concentration of T5T3~Tt>ers./bc. N^oth men wore respirators during the entire operation, hair on each man possibly prevents an adequate seal. nTie OSHA ceiling limit for asbestos is 10 fibers/cc. The OSHA standard for an eight-hour time-weighted exposure is 2 fibers/cc. Due to the short exposure time (25 minutes), the insulators' TWAs would not exceed the OSHA standard without further exposure. However, in future operations where large amounts of water cannot be used to reduce emission of air borne asbestos fibers, a garden sprayer might be used since a finer spray and smaller volumes of water can be used. L DISCUSSION Mr. C. C. Bragg and Mr. C. R. Lanier wore per sonal samplers while removing insulation from the flanges of a pipe line in Building 233. Due to the storage of Sevin directly under the pipe line being worked on, the insu lation could not be watered down during removal. Both men wore respirators. One man stripped the insulation while the other held a plastic bag directly under the flange to catch the insula tion. The effectiveness of this procedure in keeping down airborne asbestos dust in the surrounding area was indicated by a sample taken eight feet below the first flange which showed a concentration of 0.3 fibers/cc. The personal samples indicated concentrations of 7.75 fibers/cc and 5.37 fibers/cc for a twenty-five-minute exposure. Further exposure was minimal since the pipe was to be UCC 016661 2 dismantled at the flanges and taken outside where it could be wetted with water before, during, and after removal. DATA Date 01/22/79 01/22/79 01/22/79 Sample C. C. Bragg C. R. Lanier Area Sample below first flange Sampling Time 0855 - 0920 0855 - 0920 0855 - 0920 Air Cone. Fibers/cc 7.75 5.30 0.30 REFERENCES (1) UCC C/P Industrial Hygiene Method 38C-29X4-Rla (2) 29 CFR 1910.1001 REPORT PREPARED BY W. F. Blythe, Jr. Technical Center Industrial Hygiene Group WFBJr/sc UCC 016662 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: D. L. Johnson, 511-5518 Computer Ref. W-1043 CC: C. W. Carman, 725-105 G. F. Hurley, 701-334 C. R. Johnson, 511-2009 L. R. Noble, 511-2149 D. R. Paugh, 511-2009 P. A. Perry, 511-5583 H. L. Robinson,. 701-401 E. C. Shipley, 511-2009 PERSON MONITORED T. L. Jividen Location#! Powerhouse - Institute Date 4/28/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. fibers ^ > .52 5 urn/cnr ! Sampling Time 57 minutes .62 " 111 minutes Comments A.M. - Stripping insulation A.M. - Stripping insulation Time-Weighted Average Concentration (TWA) Not monitored long enough to Ceiling Concentration calculate TWA ALLOWABLE EXPOSURE TWA 2 fibers > 5 ixm/cm3 Ceiling _______________________ (qSHa) OSHA UCC UCC ,, Other Other COMMENTS Stripping insulation from several steam lines on #1 boiler on the first level of #1 Powerhouse at Institute. Sometime during the afternoon, the filter cassette worn by Mr. Jividen was lost so a TWA was not calcu lated. During the stripping he wore a disposable dust respirator and dis posable coveralls. Even insulation that does not contain asbestos should be watered to help conttrrooll^^tthhe dust. CJjjtfJWORK BY Jjj4j APPROVED BY 7 UCC 016663 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: D. L. Johnson, 511-5518 Computer Ref. W-1043 CC: C. W. Carman, 725-105 G. Fl Hurley, 701-334 C. R. Johnson, 511-2009 L. R. Noble, 511-2149 PERSON MONITORED F. E. Cobb P. A . Perry, 511-5583 D. R . Paugh, 511-2009 H. L . Robinson, 701-401 E. C . Shipley, 511-2009 Location #1 Powerhouse - InstituteDate 4/28/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. fibers ^ .15 5 Lun/cnU .37 " .06 " .52 " Sampling Time 63 minutes 108 minutes 30 minutes 45 minutes Comments A.M. - Stripping insulation A.M. - Stripping insulation P.M. - Stripping insulation P.M. - Stripping insulation Time-Weighted Average Concentration (TWA) .14 fibers > 5 nm/cmS Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 iim/cm3 ^SHA^ UCC Ceiling _______________________ OSHA UCC Other Other COMMENTS Stripping insulation from several steam lines on #1 boiler on the level of #1 Powerhouse at Institute. Mr. Cobb wore a disposable dust respirator and disposable coveralls during the stripping. firs Even though part of the insulation being stripped did not contain asbe tos, the insulation should be well watered to help control the dust. WORK BY APPROVED BY UCC 016664 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: D. L. Johnson, 511-5518 Computer Ref.W-1043 oo C. W. Carman, 725-105 G. F. Hurley, 701-334 C. R. Johnson, 511-2009 L. R. Noble, 511-2149 K P. A. Perry, 511-5583 D. R. Paugh, 511-2009 H. L. Robinson, 701-401 E. C. Shipley, 511-2009 PERSON MONITORED T. G. Grant Location #1 Powerhouse - Institute Date 4/28/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. fibers ^ > .43 5 um/cm* * Sampling Time 58 minutes ' Comments A.M. - Bagging insulation .64 " 116 minutes A.M. - Bagging insulation .34 " 89 minutes P.M. - Bagging insulation Time-Weighted Average Concentration (TWA) .27 fibers > 5 |im/cm3 Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers > 5 pm/cm3 Ceiling _______________________ (QSHA) OSHA UCC UCC , Other Other COMMENTS Bagging insulation that had been stripped from several steam lines on #1 boiler on the first level of #1 Powerhouse at Institute. The stripped insulation was placed in plastic bags tagged and placed in a dumpster for proper disposal. Mr. Grant wore a disposable dust respirator and disposable coveralls. juiJl)WORK BY APPROVED BY UCC 016665 imm 1 INTERNAL CORRESPONDENCE /*/**:' &9***sc2 swfoj/r*'e CHEMICALS AND PLASTICS To (Name) Division location Copy to Mr. D. L. Johnson Mr. L. R. Mr. H. L. Robinson Mr. E. C. Shipley Mr. E. J. Tawney P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Date March 3, 1980 Originating Dept. Technical Center IH/EP Subject Asbestos Monitoring at Institute #2 Powerhouse PROJECT Monitor exposure of employees to airborne asbestos fibers during the removal of insulation from a boiler at the #2 Powerhouse at Institute. DATE OF SURVEY February 20, 1980 DISCUSSION Construction insulators and laborers wore personal samplers during the removal of insulation from the third level of the easternmost boiler in the #2 Powerhouse. All employees involved wore disposable coveralls and respirators. The insulation was adequately wetted with water during removal. The first set of samples was taken while the insulation was being removed from the front of the boiler and placed in plastic bags. The second set of samples was taken while insulation was being removed from a horizontal section of the boiler and shoveled into plastic bags. The personal air samples indicated concentration from 0.2 to 0.8 f/cc. The OSHA standard sets a permissible exposure limit of 2 f/cc for an eight-hour time-weighted average exposure and a ceiling limit for a fifteen minute exposure of 10 f/cc. Continued use of the prescribed work procedures - use of water to wet insulation, respirators, barricading the area, etc. - should aid in keeping exposures below the OSHA standard. DATA See page 2. UCC 016666 2 3/3/80 DATE 2/20/80 A1l ' 1 1 1 1 1 1 l 1 1 1 1 V SAMPLE G.H. Landers ?t Tt J.H. Johnston C.N. Cunningham T.G. Grant SAMPLING TIME 0905 - 0935 1010 - 1145 0906 - 0935 0935 - 1058 0911 - 0935 1045 - 1145 o 00 AIR CONC (f/cc) 0.2 0.4 0.1 0.3 0.7 REPORT PREPARED BY W. F. Blythe, Jr. Technical Center Industrial Hygiene Group APPROVED BY WFBJr/sc UCC 016667 INTERNAL CORRESPONDENCE o (Name) division ccation lopy to Mr. D. L. Johnson Mr. E. C. Shipley Mr. E. J. Tawney Mr. L. R. Noble \ Mr. H. L. Robinson P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Date March 29, 1979 Originating Dept. Technical Center IH/EP Subject Asbestos Monitoring at Institute PROJECT Monitor exposure of insulators to asbestos during the removal of insulation from a 3" steam line in East Area Complex Six. DATE OF SURVEY March 17 and 19, 1979 DISCUSSION Construction insulators J. F. Sampson and G. P. Hall wore personal samplers while removing sections of insulation from a 3" steam line which crossed the road approximately 15 feet above the ground. The area below the insulators was evacuated initially with some walk-through traffic later. The insulators wore respirators during the entire operation. The insulation was not wetted with water during removal. The personal samples indicated asbestos con centrations of 3.4 and 1.7 fibers/cc. When it was determined that another section of insulation needed removed, more personal samples were taken. This time the air concentrations were 2.9 fibers/cc and 0.7 fibers/cc. On March 19, 1979, Mr. J. F. Sampson and Mr. D. L. Carpenter wore respirators and personal samplers while removing insulation from the steam line-which was taken - down on the 17th of March. The insulation was wetted with water before and during removal. The air concentration indicated by the samplers were 0.2 fibers/cc and 0.4 fibers/cc. An area sample twenty feet downwind from the operation showed a concentration of 0.01 fibers/cc. The OSHA standard sets a ceiling limit for a 15-minute exposure of 10 fibers/cc and a limit of 2 fibers/cc for an eight-hour time-weighted average expo sure. UCC 016668 2 3/29/79 SUMMARY, CONCLUSIONS AND RECOMMENDATIONS The exposures of the insulators were below the OSHA permissible exposure limits. Exposure requirements of the OSHA standard may be more easily satisfied by the use of wet methods to prevent emission of airborne asbestos fibers. One way to do this is the use of garden sprayers to wet asbestos-containing insulation in locations inaccessi ble to water hoses. Also, in order to better protect other employees in the area from exposure to excessive concentrations of airborne asbestos fibers, barricade tape and warnings signs should be posted around every asbes tos job. It may be useful to have stands made to which the tape and signs could be fastened. DATA Date 3/17/79 3/17/79 3/17/79 3/17/79 3/17/79 3/19/79 3/19/79 3/19/79 Sample J. F. J. F. G. P. G. P. Area Sampson Sampson Hall Hall J. F. Sampson D. L. Carpenter Area Sampling Time 0830 1023 0830 1021 0835 - 0940 1038 0940 1038 1040 0850 0850 0853 - 0938 0938 0940 Air Cone. (F/cc) 3.4 1.7 0.7 2.9 0.3 0.2 0.4 0.01 REFERENCES UCC C/P Industrial Hygiene #38C-29X4 - R1A OSHA 29 CFR 1910.1001 REPORT PREPARED BY W. F. Blythe, Jr. Technical Center Industrial Hygiene Group W. F. Blythe, Jr. APPROVED BY G. F. Hurley UCC 016669 INTERNAL CORRESPONDENCE :hemicals and plastics o {Name) ivsion ^cation opy to Mr. D. L. Johnson Mr. E. C. Shipley Mr. E. J. Tawney Mr. L. R. P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Date June 4, 1979 originating DeptTechnical Center IH/EP suoject Asbestos Monitoring PROJECT Monitor employee exposure to asbestos during the removal of insulation in Building 5 at Institute. DATE OF SURVEY April 30, 1979 DISCUSSION . Personal samplers were worn by Mr. K. A. Neal and Ms. H. F. Beaver while removing insulation from piping in the east end of the first level of Building 5. All the insulators on this job wore Norton 7170 respirators. The insulation had a layer of dust sitting on it. Although some water was used to wet the insulation during removal, enough dust was generated to interfere in the analysis of asbestos. The sample worn by Ms. Beaver was voided while the one on Mr. Neal Indicated an asbestos concentration of 1.85 fibers/cc. The OSHA permissible exposure limit for an eighthour time-weighted average (TWA) exposure is 2 fibers/cc. CONCLUSION Since this job did not take eight hours, Mr. Neal's TWA would be less than 1.85 fibers/cc and below the OSHA limit. However, the amount of dust and asbestos in the air indicates the need to use more water before, during and after the stripping of insulation. REFERENCES UCC C&P Industrial Hygiene #38C-29X4-R1A 29 CFR 1910.1001 UCC 016670 2 6/4/79 REPORT PREPARED BY W. F, Blythe, Jr. Technical Center Industrial Hygiene Group W. F. Blythe, Jr. APPROVED BY WFBJr/sc UCC 016671 3W(4 /*<:& A,p/s v i s'h'f INTERNAL CORRESPONDENCE i) z ' ' i/AiCALS AND PLASTICS --srjrrt9T9-- SAFETY DEPT, P. O. BOX S361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Mr. D. L.. Johnson 511-5518 (512) Mr. Mr. Mr. Mr. Mr. Mr. Mr. Mr. C.W. G. F. C. R. D. R. P. A. C. E. H. L. E. C. Carman j. Hurley Johnson Paugh Perry Richardson Robinson Shipley . Dale December 10, 1979 cr^n^ng D-,pi.Technica 1 Center, IH/EP Sob.ect Asbestos Monitoring 704 Powerhouse PROJECT Determine the exposure of Construction workers to asbestos fibers during insulation stripping in Building 704. e DATE OF SURVEY November 26 and 27, 1979 DISCUSSION On November 26 and 27, 1979, separate breathing zone samples were taken on Construction workers to determine their exposure to asbestos fibers while they were stripping and bagging suspected asbestos containing insulation from the exhaust ducts of Number 3 and Number 4 boilers in Building 704 - Powerhouse. During the stripping and clean-up procedure all Construction workers in the work area wore Norton disposable dust respirators, gloves, and coveralls. The boilers had been shut down so the insulation could be properly wetted before and during' the stripping. Plastic was placed around the duct to prevent debris from the stripping from falling through the floor grating. Stripped insulation was placed in bags on site for disposal. CONCLUSIONS The results are given in the attached table. An 8-hour timeweighted average was calculated for November 26, 1979, since the UCC 016672 Mr. D. L. Johnson 2 12/10/79 Construction workers were monitored during their total exposure for that day. The values are well below the OSHA standard of 2 fibers > 5 jim/cm3 on a time-weighted average for eight hours. REFERENCES Volume 38C-29X4-Rla Asbestos, Dust Determination By Membrane Filter Technique Using Phase Contrast Microscopy RESULTS ' See attachment. REPORT PREPARED BY Ruth Clise Technical Center Industrial Hygiene Group REPORT APPROVED BY RC/sc Attachment UCC 016673 Bagging and c le a n in g (A ttachm ent) sss <<a 111 bo fan bn GCG CO H *H *rH aaa Pi ft ft ft < H *H *H ^^^ w Pi CO CO CO sss <c a iii bo fan bn ccc tH *H *H aaa ft ft ft H *rH H m^^ -p -p +-> CO CO CO s saa <; ft ft till bn bo bn bo . CCGC H H iH `H bn bn bn bn bn bn bn bn dd dd n n nn tj x! x) n c a aa dddd bn bn ho bn GGGG H *rH *H *H GGGC dddd CD CD <1) CD --1 rH rH rH oooo S2 S S << aa iiii bn bn bn bn GC GG rH *rH *H *rH bn bn bo hn bn bn bn bn cS rt d d DDDD a T3 a x) GG GG cS ci d d bn cn bn bn GGGG rH H *H CGGG d d ci ci O 0 <D i-K rH rH rH oo o o bn G H G d <D rH o TJ G bn bn d Gc H H bn aa G a a H rH H bn Jh Sh -P P> bn d CO CO m P ww E-* O 1 K< WO PS SMW nW> Eh S= <J t o A 1 1 1 I A CO CO O cn e Eh CO ^ O CO pi <u \ W Wn 6 taW'H a co t-i w < w^ 1------------------ 1 1 oooai <N rH in o A 1 1 1 1 11 11 rj< m in CO Ol 00 rH o A 1 1 1 1 1| *1 co m co ^ O O) ^ ^ CO .-c , m o A 1 1 1 1 1 1 O O CD CO cn o1 co o <M a DC (M CD CD oO o 1 1 /2 7 /7 9 D. R. P o w e ll 38 1 .8 6 RESULTS cn 0) W P> ss MG E"* 'H s in co ^ Tji a CD w Pw aa S Sw < Eh CO UPu XXX U U t-i cacQW SS2 CO CO CO C'HO ^a o MO OOO ^ O CO CD rH t-- d CO CD ^ O 00 ID rH cn cn cn U ^ 5h <U d> <u X3 Tj Xj ccc ddd PPP KWH ooo CGGG ps ? 5= oooo 5h P M Sh cq m m m aaaa aaaa ' rH t--^ rH rH rH rH rH rH CD <X> CD CD ???? oooo aaaa xXXX PQQQ cti rH m in e ci X bfi o G rH rH -d GG Gd DA OO S5 pH o G ? O P a CD t\ CD w co Eh \ C rH Q rH a cn c- o \\ CD CD <N <N \\ rH rH rH i--( a o \ CD <N \ rH rH UCC 016674 aa a t- o \\ \ t> t> CO CO CO \\\ rH rH rH rH r--1 rH INTERNAL CORRESPONDENCE .y\ (V-A <4 aYk ..O' .W "( 1 0^^ NOV 2 0 1S79 jatfClYlliW- }<U(6) Af "-vIMICALS AND PLASTICS P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Mr. D. L. Johnson 511--5518 (512) Mir. Mr. Mr. Mr. Mr. Mr. Mr. Mr. vt, ciiW^Carma n> G. F. Hurley C. R. Johnson D. R. Paugh P. A. Perry C. E. Richardson H. L. Robinson E. C. Shipley Date November 16, 1979 Originating Dept.Technical Center. IH/EP Subject [Asbestos Monitoring^ -704 Powernouse, First and . Second Level PROJECT Determine the exposure of Construction workers to asbestos fibers during insulation stripping in Building 704. DATE OF SURVEY October 26, 1979 DISCUSSION On October 26, 1979, separate breathing zone samples were taken on J. C. Erwin, J. F. Chandler, S. M. Barker, D. R. Powell, and P. M. Brown to determine their exposure to asbestos fibers. They were stripping and bagging approximately thirty feet of an 8-foot by 6-foot exhaust duct coming from No. 3 boiler in Building 704 - Powerhouse on the first and second levels. During the - stripping and clean-up procedure all Construction workers wore Norton disposable dust respirators, gloves, and coveralls. All others who needed to be working in the 704 Powerhouse operating area were given 3M disposable dust masks to wear during the strip ping. Because the duct was hot and electric motors were situated near the duct, the insulation was only minimally wetted with a garden sprayer. The dust created by the stripping and throwing the insulation to the floor became so heavy that the insulators were advised to UCC 016675 Mr. D. L.. Johnson 2 11/16/79 hand the insulation to the laborers to be bagged. The stripped asbestos was placed in plastic bags for disposal. - When the dust became so heavy at the site of stripping on the second level, samples were taken on the first level on the north and south side of the stack. ' . ?. After the stripping of the duct on the second level was com- : pleted and the dust had settled some, breathing zone samples were ; taken on D. R. Powell and P. M. Brown as they finished bagging__thej/ stripped insulation and cleaned the second level area. ' : When the stripping started on the first level, only area samples were taken. Two samples were taken on the first level on the north . and south side of the stack, and one sample was taken on the west wall north of the stack on the second level. All area samples were placed at breathing zone level. CONCLUSIONS The dust collected on the breathing zone samples of J. C. Erwin, J. F. Chandler, S. M. Barker, D. R. Powell, and P. M. Brown, was so heavy that it was impossible to determine the concentration of asbes tos fibers on these samples. The results of the other samples are given in the attached table. . Since asbestos levels were so high on samples taken after some.of the initial dust had cleared, they were likely higher during-the period of greatest dust concentrations. Since all people in the area wore masks they were probably protected if a good mask fit was . obtained. RECOMMENDATIONS It is suggested that all Construction workers that are involved with the stripping and disposal of suspected asbestos containing insulation be shown the Industrial Hygiene slide presentation on the proper handling of asbestos containing materials. REFERENCES Volume 38C-29X4-Rla Asbestos, Dust Determination By Membrane Filter Technique Using Phase Contrast Microscopy UCC 016676 i i My D. L. Johnson 3 11/16/79 RESULTS DATE 10/26/79 SAMPLE TYPE Area 10/26/79 Area 10/26/79 D.R. Powell 10/26/79 P.M. Brown 10/26/79 Area . 10/26/79 Area 10/26/79 Area TIME ASBESTOS FIBERS (MINUTES) (Fibers >5 |j.m/cm3) REMARKS 32/2 LPM 0.28 First level, north side of stack while dust was settling afl stripping on the sect level. Cleanup being completed on second level. 27/2 LPM 0.51 First level, south side of stack while dust was settling afl stripping on the secc level. Cleanup -being completed on second level. 15/2 LPM 3.93 - Bagging insulation after stripping on second level finishei 15/2 LPM 2.97 Bagging insulation after stripping onsecond level finishei 51/2 LPM . / 1.01 First level,- north o: stack while first le1 being stripped.- 55/2 LPM 0.9 First level, south o; stack while first le being stripped. . 48/2 LPM 1.16 Second level, on wes wall, north of stack while first level be stripped. REPORT PREPARED BY Ruth Clise Technical Center Industrial Hygiene Group CI,,J Ruth Clise UCC 016677 Mr. D/ L. Johnson REPORT APPROVED BY George F Hurley RC/sc 4 11/16/79 UCC 016678