Document 3NK1nze2LBmBnvE93N18mQz80

NIVERSITY OF CALIFORNIA, BERKELEY HIGHLY CONFIDENTIAL SUBJECt TO PROTECTIVE ORDER Dirturr davis orvxNr to* anczus - nvcnniE can pieco * ean dramcisco SANTA UMAIIA SANTA CRUZ school, or rvauc health earl warren hall BERKELEY, CALIFORNIA 94730 September 9, 1970 CONFIDENTIAL MEMORANDUM TO: Hr. John H. Price, Jr. Vice President - Marketing Pittsburgh Corning Corporation CDR S. H. Barboo Bureau of Medicine and Surgery Department of the Navy FROM: W. Clark Cooper, M.D. Professor of Occupational Health in Residence University of California, Berkeley Douglas P. Fowler Industrial' Hygienist University of California, Berkeley RE: Products listed in report: "Dust-Producing Potential of Construction Materials," by Bernard D. Tebbens, J. LeRoy Balzer, W. Clark Cooper, and Irving R. Tabershaw of the University of California, Berkeley. The products listed in the report are: A. Kaylo (Owens-Corning) B. Unibestos . (Pittsburgh-Corning) C. Thermobestos (Johns-Manville) D. -Caltemp (PASCO) WCC/DPF:ja r DUST-PRODUCING POTENTIAL OF CONSTRUCTION MATERIALS Bernard D. Tebbens, Sc.D., J. LeRoy Balzer W. Clark Cooper, M.D., and Irving R. Tabershav, M.D. Purpose of Study The purpose of this study was to develop methods for assessing the hazard potential of asbestos-containing construction materials. The methodology was to be developed during a systematic study of four commercial Insulation products containing asbestos. The results include the actual concentrations of airborne asbestos fibers found to result from operations typical of the industrial uses of these products. The necessity frequently arises in industry to predict the potential hazard during comminution of a solid material. In other words, "is the dust produced by sawing, drilling or filing of a solid containing a hazardous component necessarily of the same composition as the parent material?" At first glance, the answer must seem, "Obviously, yes." In reality, however, there are several factors which can result in a different distribution of components. Occupational exposures to potentially hazardous dusts may be affected by the conditions of use of the materials from which the dusts are generated or by the physical characteristics of the material. 1 * 2 Occupational exposuresof construction craftsmen to airborne asbestos fibers are primarily a result of the comminution of thermal insulation materials during their installation, repair, and removal.^ Inhalation of asbestos fibers has been shown to cause, or be associated with, an increased 20 2- - A5 incidence of fibrotic and neoplastic disease. ' However, at present, there are no thermally suitable alternatives to asbestos-containing materials for the prevention of heat loss from high-temperature (750*F and higher) pipes and boilers. There are two major types of asbestos-containing thermal insulation products. One of these is made by binding a mat of amoslte asbestos fibers with sodium silicate, either with or without the addition of dlatomaceous earth (Product B). The minimum asbestos fiber content of this type Is approximately 60Z. The other major type is prepared by baking a slurry of calcium silicate and amoslte and/or chrysotile asbestos fibers and contains approximately 10-15Z asbestos (Products A, C and D). r It has been suggested that exposure of insulation workers to asbestos fibers might be substantially reduced by restricting the use of products which have a high asbestos content. However, the two types of materials differ significantly in their physical properties so that the asbestos concentrations in aerosols generated during the handling of the two types might differ in ways not directly related to the concentrations of asbestos in the parent materials. The 60Z asbestos/sodium silicate insulation has been described as being more readily cut and shaped than the calcium silicate products, requiring the application of less prolonged or Intense force for a given shaping operation. There are also significant differences in the two types of asbestos fibers used in the materials, amoslte being of greater specific gravity than chrysotile (3.5 vs. 2.5), and having individual fibrils of 21 3- - larger diameter than chrysotile (0.1 Mm vs. 0.01 Mm). Thus, it would seem that there are theoretical arguments favoring the product with higher asbestos content. The greater ease of fabrication would mean a shorter period of production of the aerosol, and the larger, more dense amosite fibers would tend to fall out of the produced aerosol more rapidly than will chrysotile fibers. Research Performed Four thermal insulation products, 9-lnch outside diameter and 3-inch Inside diameter, containing differing asbestos types and concentrations were tested for respirable dust production- under conditions simulating actual usage. These products were purchased "blind"; a reliable third party not connected with the University or any of the manufacturers concerned purchased the products through the normal market channels ordinarily used by him in his purchases of other insulation products. Thus, we entered the market randomly; the products used in this study are a "grab sample" of the products which might be delivered to any user. Product D was the only one of those tested which did not meet the original broad specifications; it was supplied as two 1 1/2-inch layers and not the single layer of the other products. The wholesaler confirmed that Product D is not supplied in a single layer in 3-inch thickness. Therefore, it was used as received since this is the way it would be supplied to Insulators in actual practice. A-test chamber (shown in Pigures I and II) was constructed measuring 10'4" long by 9'8" high by 10' wide. The total volume was 1,000 cubic feet. 22 The room was lined with 0.006" plastic sheeting to facilitate cleaning. Farr Company HP 200 filters were used to filter the supply air and the exhaust. Air exchange rate between test runs was 290 cubic feet per minute. After each run, and between products, the room was flushed for a period which varied depending on the observed "dustiness" of the room but was a minimum of 20 minutes (about 6 air changes) . Before each change of product (or change in process), a background air sample was taken In the "room" position (described below); each sample subsequently taken in that series (or run) was then corrected by having the background concen trations subtracted. Ihe following operations (described in greater detail below) were performed on each product by an Insulation mechanic (Journeyman asbestos worker). I. Simulation of pipe covering, and tear-out of heat stressed pipe covering. II. Power sawing of the products to simulate on-site fabrication of specific shapes of the material by a bandsaw; and the "scoring" of blocks. III. Pounding with a simulated hammer to estimate the effects of force-fitting (not performed by the insulation mechanic). In each of these operations (except the tear-out and pounding), the insulation mechanic was permitted to set his own pace; the specific plan of operations was determined in consultation with him so that practices 23 5- - usual to the trade were followed. The insulation mechanic used a "Whitecap" aupplied-air respirator throughout; the asbestos fiber concentrations in the air supplied to him were far below the proposed Threshold Limit Value. Sampling and Analysis Air-samples were taken by drawing air through Mllllpore 0.6 im mean pore size organic membrane filters. Filters of 37 mo diameter were used for the per sonal breathing zone samples and 47 mm diameter filters for all other samples. Additional samples were taken using Nuclepore membrane filters (0.8 um mean pore size) for subsequent electron microscope analyses. During the simulated pipe-covering, tear-out, and bandsawing, samples were taken at five locations within the test chamber: 1) in the middle of the chamber, with the open-face filter holder 8 feet above the chamber floor level ("Roof" samples); 2) from a support projecting into the chamber approximately 1 foot from the wall opposite the work bench on which the covering was done, through an open-face filter holder about 6 feet above the floor ("Room" samples); 3) above the work bench (near the wall closest to the bench) with an open-face filter holder ("Bench" samples); 4) in the same location as the Bench samples but with the air drawn through a Hexhlet Horizontal Elutrlator (Casella-Wilson) before passage through the in-line filter holder ("Elutrlator" samples); 5) in the Insulator's breathing zone with disposable Mllllpore Field Monitors (open face) ("Personal" samples). Sample air flow rates were: Roof, 0.7 cubic feet per minute (cfm); Room, 0.5 cfm; Bench, 0.5 cfm; Elutrlator, 50 liters per minute (1.8 cfm); and Personal, 0.11 cfm. See Figures I and II for these locations. 24 5a --------<JJ kg> g ' m | M i u K s1 M cm n IV- ncou it 25 During the scoring operation, only two sampling locations were utilized (Room and Personal samples) as shown In Figures I and II. The pounding operation was monitored with four samplers, one on the bench above the product being pounded ("Bench top") and three others approximately 5 feet distant from the pounding site, A feet above floor level. One of these filter holders was directed upward ("Up"), another directed downward ("Down"), and the other directed horizontally ("Horizontal"). Flow rates here were 1.9 efm for the Mass, 1.0 cfm for the three others. These locations are shown in Figures III and IV. 2G I l l S1A9U -6a- j 27 D tM iu to M a n u uahova H | . I I 7- - Analysis of the collected samples was directed at obtaining two measures of the relative amount of dust production from the products being tested. All filters (except the 37mm Personal sample filters) were weighed before and after use, each such weighing proceeded by desiccation for two hours to stabilize weights. From this weight data, the -gravimetric concentrations of total airborne dust were computed in milligrams per cubic meter (mg/m^) by dividing the milligrams change in weight by the total cubic meters of air which had passed through the filter. This was the sole analysis applied to the "Bench", "Elutriator", and "Bench top" samples. The other sample filters were analyzed to determine the concentrations ^ of asbestos fibers in addition to the gravimetric analysis. This analysis was by the standard method for the determination of asbestos fibers collected on membrane filters:** a wedge of the weighed, exposed filter was cut from the filter and the wedge (about 1/8 of the total filter) placed on a standard microscope slide on which was placed a drop of a mounting medium which matched the index of refraction of the organic filter. The filter wedge thus "cleared" was examined with phase contrast micro scopy at 430X magnification, with the microscopic field of examination limited to the area bounded by a Porton eyepiece reticle (0.0061 mm2 per field). The asbestos fibers seen in each field were recorded and placed into several length and diameter categories, and the field shifted to another portion of the filter. This process was continued until 100 such fields had been examined, or until 300 fibers had been counted and sized. 28 8- - When 300 fibers (or 100 fields) were accumulated from any one sample, the count within the field was completed and the count then terminated for that sample. The concentration of asbestos fibers per liter of air was determined by taking into account the area of the filter surface examined (0.0061 mm ), the total exposed filter area (960 mm ), the number of fibers counted, and the flow through the filter in milliliters. This result was expressed as fibers per milliliter (f/ml). The proposed Threshold Limit Value (American Conference of Governmental Industrial Hygienists) is only for those fibers longer than 5 micrometers (pm). Therefore, asbestos fiber concentrations expressed within this report are given for both total asbestos fibers and asbestos fibers longer than 5 Urn in the tables of results, but the graphic expression of fibers per ml. is limited to fibers longer than 5 pm. Specific Operations I. Pipe-covering. Three 'funs" were made on each product during the simulation of pipe covering. For each of these runs, two 36-inch long half-round sections of insulation were cut into 18 separate pieces by cutting across at 4" intervals, the major axis of the 36-inch long sections. These 4" sections were then wired in place around a 48-inch long piece of 3" I.D. cast-iron pipe so that the final covering of the pipe extended for approximately 35" (with about 1 inch lost because of saw blade width). The wired insulation was "mudded" with a mix which was constant throughout the series of tests, and the mudded surface wrapped with medium-weight canvas. 29 9- - ( using wheat-paste adhesive. The material removed by these operations was weighed at the completion. The wrapped pipes were air dried for at least two days and then heat-stressed. The heat stressing was accomplished by Inserting Cal-Rod heaters Into the pipes; current flow into the heaters was controlled by chrome alumel thermocouples (within the pipes but not touching the heaters) actuating standard temperature control relays; potential differences in the thermocouples were monitored by a multi-channel recorder which was activated for 15 minutes in each 12-hour period. Temp eratures in the pipes were held at 1150*F (+25*F) for 96 hours, with current to the Cal-Rod heaters shut off with a timing switch at the completion of that time. When all products had been applied and heat-stressed, the insulation was removed from the pipes in simulation of ship-board tear-out operations. All three pipes for one product were placed in the chamber, and the mechanic given a knife, a hatchet,, and a three-minute time limit within which to remove all three coverings. Air samples were taken for five minutes, in order to standardize results, since only one sampling opportunity was available for each product. Figure V shows a schematic diagram (flow chart) of this series. ( J 30 -9a- naawt Cmrlif and hu>Oul Kaan Um riyulni (for t fttll fount ncUcb) Air ibz;Ita pr product () full aactlona) BARS SATOO A 6.2 adn. 9.0 sin. e 11.5 Bin. 0 6.1 ala. 50 I 31 -10Results (Pipe Covering) Tables 1-4 show the results of the air sampling for these operations, 3 expressed as milligrams of total particulate per cubic meter of air (mg/m ), total asbestos fibers per milliliter of air (f/ml), and asbestos fibers longer than 5 micrometers per milliliter of air (f/ml 5). All concentrations have been corrected for background. The concentrations from the various products are shown graphically in Figures 1V-IX, where fiber concentrations (f/ml) are given only for those fibers longer than 5 pm. 32 10a Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product A T.bl. 1. Mpa CoartB| l.nlt. frodvct A Operation ri f/i f/.l 73 33 Naan Standard Deviation 27.764 22.711 St.Ml M.OU 12.010 26.040 24.039 24.947 48.324 27.331 27.003 24.249 S3.SS4 __29,343 11.380 9.400 Application Standard Deviation 16.306 13.726 16.4*4 16.634 12.202 13.944 14.843 _J!.*U 2.6*9 . l.*47 Taarout | 49,231 47.621 tfml *.34 23.16* 9.11* 13.831 13.731 31.2** \7.447 8.97* aaf f/alOS) 6.130 23.663 6.366 13.041 14.911 2*.*34 SaanUa B b./.1 1 f/al 20.216 6.169 6.66* 2.77* 2.33* 6.3*2 10.261. 13.3*2 2.156 9.166 5.227 13.44* 16.361_ *6.771 4.922 9.343 Boon Beneb f/BlOS) UstZsl _HtZ-1 6.6*9 14.1*1 2.102 6.7*5 3.170 15.0*1 4.070 6.341 4.303 0.41* 0.103 3.733 10.034 6.017 10.635 1.316 6.243 61.250 tlucrlator 1.414 6.167 0.346 0.679 1.146 1.317 *.041 10.316 1.315 2.490 14.293 23.239 2.276 3.121 19.072 13.62* 21.0*1 -l*.46t. 2.633 16.613 13.332 20.46* 2.503 10.011 3.566 6.601 7.206 2.641 4.221 3.014 *.654 e.?o 4.446 4.120 12.673 *.444 8.744 4.320 2.476 2.367 3.67* 0.354 I1.782 1.601 | 0.9*3 1 0.411 1 3.2*2 1.167 1.278 l.w 1.1*6 26.931 23.266 10.374 _7J83 _ 7.477 j*.324 21.074 ___ 3.960____ Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product B T.bl. 2. Plpt Coverln* *e*ult Product B Oparatloo L f.r r/al r/.l( 5) f/.l Roof f/l( 3) Boditvlti 142.313 1*2.323 213.608 281.287 248.423 302.443 Naan 210.304 Standard 39.223 Deviation 121.046 154.477 178.739 240.329 202.610 263.474 1*3.84* 37.473 110.1*0 180.347 42.349 223.834 134.833 108.344 117.067 33.807 97.400 130.413 34.420 217.847 U7.279 92.874 127.074 117*46 Application 37.133 124.723 131.140 Naan JU3.667 Staadard 31.442 Devtatloa 49.708 109.142 111.164 43.048 36.807 38.733 30.417 _42.QJ8 7.474 30.342 34.484 46.731 8.333 T..rrt 762.021 346.3*3 71.477 49.121 r Saaplia .t/al toon f/.u i) `taneh -*/-1 k/-> Blotrlator M/a1 *.736 11.114 1.606 17.530 24.911 13.468 17*27 63.015 It*. 7*2 23.276 1*8.611 101.402 101.910 108.341 61.110 ' 17.*37 113.401 21.*7* 163.284 90.482 97.923 94.309 57.JTTT" 0.183 17.412 1.174 15.121 7.683 11.331 10.464 1.111 6.177 13.2*7 16.432 38.307 19.378 *.*12 17.411 "inns 2.713 1.489 6.2*7 17.937 3.376 21.0*6 8.820 1.4*0 10.160 10.774 13.479 11.472 1.766 23.051 32.099 39.048 32.064 7.074 19.897 27.00ft 33.127 27.404 7.723 6.333 9.661 9.66* 9.295 0.620 7.116 3.*03 7.67* 6.906 o.uo 1.262 2.77* 7.641 3.967 1.417 19.136 137.946 113.164 27.289 33.170 3.713 lv 38 10b Airborne Asbesto9 Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product C Fcuonii f/i IUa4aavlB| Standard BYltiffO 5.493 11.319 u.ur 11.809 I.M4 10.270 2.810 3.413 u.m 10.342 11.011 6.443 4.017 2.091 Affllutloft .Huo . _ Standard DfYlltlon 3.828 5.922 7.837 .6.329 1.134 4.339 4.932 4.141 3.172 0.976 Tcaroot 13.Ml 11.314 T.Wl. V flH Cavarlim Miult* Product C oof f/-l_. f/lf>57 tmm /* 1.802 3.322 4.033 5.084 3.341 4.083 3.784 1.193 1.774 2.850 4.441 4.911 1.19* 3.970 1.544 1.141 4.319 6.048 1.03* 11.891 4.403 10.131 7.043 1.909 f/.i 0.993 1.491 6.586 4.306 4.129 1.002 3.610 1.916 lOM r/.u>5) 0.931 2.248 3.889 1.796 3.810 1.003 3.280 1.674 M/J 0ocK */.J Cl.trt.c.C m/.) 4.137 4.392 1.462 1.617 7.908 4.266 4.167 2.077 2.613 0.083 0.205 1.094 10.334 4.786 _).134 1.921' 0.903 0.661 2.449 0.191 5.000 10.201 __ LV>2 11.680 5.912 3.301 2.504 4.661 1.872 5.911 5.180 1.146 4.316 1.907 4.444 4.871 17.919 9.081 7.6*3 1.920 7.104 3.186 4.003 2.712 1.767 6.819 4.979 4.522 2.337 1.714 1.412 3.430 4.192 1.084 1.401 6.123 4.040 4*.}*9_ 2.873 0.049 1.4M 1.419 _l.JOI 0.402 0.893 8.328 4.327 3.19] 3.015 6.591 11.114 1.M6 Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product D | 1 0ftUm Personal ttml f/.l( >3) Mjftdaavli| Fuji Standard Davtitton 28.034 11.019 30.304 27.525 34.310 41.366 17.11? 3.142 27.298 24.700 29.370 24.147 32.604 H.829 :mh) 4.870 AfflleatlM Han Standard Deviation 20.287 28.374 23.174 --2.4.013 4.204 16.080 25.963 22.214 72.)}} 1.343 Taarouf 48.242 45.840 T.kl. 4. Pip# Cmrlnt lUaulti Product D f/.i Kao f r/.u ,5) 1.040 25.240 3.309 13.398 2.962 12.206 4.*?* 9.050 1.803 23.631 3.201 13.139 2.676 10.450 4.151 0.476 Siaoltl 0.376 3.176 13.491 3.763 1.092 3.001 4.50} 5.347 r/ml 5.337 6.264 10.316 16.032 0.794 4.076 0.470 4.352 Ram 1/mU 4) 4.683 18.626 9.101 13.633 7.598 3.070 4.4)5 3.977 il.1 2.044 4.179 4.038 40.231 11.436 10.379 12.776 14.094 ImeH -8/-3 9.741 7.169 10.6)6 11.300 1.360 32.321 12. m 10.582 Elutrlator */J 4.908 2.319 0.191 3.812 4.231 4.349 1.602 2.030 10.340 24.300 19.110 y .31? 2.681 19.464 24.122 10.576 20.721 2.979 13.133 11.723 14.48) 15.700 5.404 1.287 11.123 18.009 12.166 3.471 2).606 10.353 17.54) 17.732 6.3)) 7.131 11.739 14.854 11.313 ). 769 7.320 4.326 5.461 5.770 1.411 2.781 2.313 3.253 )- 5 )0 1.491 41.001 19.686 24.068 12.318 11.766 9.963 33.136 1.182 r / 34 -10c- b g g 35 T o ta l A irb o rn e Dust (G ra vim e tric) and A irborne Asbestos F ib e r C o n ce n tra tio n s: Handsaving P o rtio n o f Pipe Covering -lOdr ( r 36 T o ta l A irborne Dust (G ra v im e tric ) and A irb o rn e Aabestos F ib e r C oncentrations: A p p lic a tio n P o rtio n o f Pipe Covering rip C*Trla| Taar-Out C rtvlM trlc ncuu x flf Cvrta| Tt O r ( * / " l *5) ncuu a -lOe- 37 T o ta l A irb o rn e Dust (G ra vim e tric) and A irborne Asbestos F ib e r C oncentrations: Tear-O ut P o rtio n o f Pipe Covering / -11- II. Power Sawing (Bandsaw) Six 3-fooc long half-round sections were cut Into (approximately) 4-inch long sections (making 9 cuts per 3-foot section), using a Dewalt bandsaw with a 1/2-inch blade with 6-blade points per inch. The linear velocity of the point tips was about 3000 feet per minute. A background sample was taken before each product change. The saw was placed in the center of the room (under the Roof filter holder). Two half-sections were cut, while samples were taken, then the saw shut off and the filters changed. This process was repeated twice more for each product. Figure XII shows a flow chart for this operation. turn SAVtKC nctnuc m Nms Um Required (for 1 full action) A 3.0 ala. I 2.1 aid. C 2.3 aln. D 3.3 ala. Air Snplti far Product 13 38 12 S' Results (Bandsaw) Table 5 shows the results for the bandsawing for all products with (again) the results listed as total asbestos fibers per milliliter, fibers (longer than 5 Mm) per milliliter, and total particulate milligrams per cubic meter. In Figures XIII and XIV are again shown the graphic representations of results. Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from Bandsawing: All Products Table 5. land Saving Result* Product Persona1 t/*i f/105> f/.i Pool f/.lDl) Saieole* t/3 tfml Koea f/.lOS) -/-J AencH Clutrlacor A Mean Standard Deviation 111.097 271.611 179.71J 216.116 3/./W 234.282 217.200 170.832 207.445 J2.dll *62.07* <66.731 1 1138.US 102 0.762 Plan_________ w-im 71*.7.2 Standard 607.326 126.224 Deviation C Hean Standard Deviation 51.072 46.226 40.661 41.960 1.220 47.*70 41.322 36.4*0 41.844 1.712 D Ha an Standard Deviation 68.060 27.425 1.311 19.119 26.111 *1.921 21.892 71.161 51.68* 26.428 4.604 122.546 114.673 Hft.AlQ 66.103 3.970 117.066 109.589 74.6*7 63.233 2.(11 13.181 31.288 73.162 17.7*1 265.243 347.770 329.006 330.676 46.267 739.961 171.179 111.141 306.697 63.943 34.143 106.671 166.679 103.896 47.493 31.906 29.204 3A.9A4 31.119 5.041 30.933 28.943 34.426 12.121 3.983 264.617 669.642 446.573 334.927 212.16* 19.344 17.201 94.66 3 43.876 44.189 17.429 17.079 93.164 62.166 0.619 14.126 33.176 194.372 81.976 99.663 106.576 104.620 91.271 101.4*0 9.066 136.886 300.599 276.314 239.267 67.642 11.101 29.011 16. 18 30.477 2.620 *1.298 22.177 11.111 *0.101 16.111 101.771 99.360 89.711 97.467 7.204 22.006 28.072 26.013 41.370 28.611 1*6.926 1*2.129 1(2.061 .1A3J31_ 2.928 18.*61 0.323 27.076 14.333 11.367 111.0.6 291.976 ?69.6l 732.254 64.877 10.810 16.717 76.000 47.169 23.39* 17*.661 186.616 133.766 172.266 15.472 29.563 60.632 36.976 34.659 3.335 12.6*1 27.271 26.171 26.746 1.400 28.610 75.719 172.711 73.6*8 *7.1*3 220.660 229.507 U2.276 190.881 59.321 31.113 11.722 20.12* 21.004 9.700 45.060 21.026 51.344 19.151 14.009 6.673 26.838 60.*18 30.390 27.*** 131.311 3*.126 261.276 146.994 118.39* 16.319 3.097 14.363 16 777 14.656 39 1AJVD SAVIRC - C ra v lM c rtc (Nj /N j rtcou m i 12a > Tc 40 f / v i r o n t - < - >T ocal A irb o rn e Duat (G ra v im e tric ) and A irb o rn e Asbestos P ihur -13- III* Power Sawing (Scoring) Two 3-toot half-round sections were scored to a depth of 1 1/A Inches, to simulate the scoring of flat blocks of insulation, as is done to facilitate the thermal insulation of large vessels (e.g., boilers) with large radii. Each section of the Insulation was scored longitudinally four times while samples were taken; the filters were, then changed and the process repeated. As above, a background sample was taken with each change of product, and an additional personal sample was taken during the clean-up process. This was done using a Ram hand circular saw ("Skilsaw" type) with a 7-inch diameter blade with 1 blade point per outside circumference inch. The linear velocity of the point tips was about 3000 feet per minute, as it was for the bandsaw. The flow chart and schematic of this operation are shown in Figure XV. scotmo ncuu xv Umo roqulrod for fcotfe mUcxii Air aomploo por produot k 2A min. B 2.2 min. C 2.T min. D l.t min. 41 -14 Results (Scoring) Table 6 shows the scoring results. Figures XVI and XVII their graphical representation. % Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from Scoring: All Products Table 4. Scoring taanlta Produce Peraooal t/i f/al(>3) Saoolee f/ml too* f/ml(>3>- -*/.J A Haan Standard Deviation 264.861 069.319 373.494 413.663 480.335 266.032 231.422 626.796 334.038 374.626 4(2.274 263.J69 201.740 44.311 133.029 7.172 1*1.937 61.411 126.684 2.310 13.434 43.30* 73.567 14.247 1- Hnn Standard Deviation 2003.442 2747.980 2645.346 3560.400 2941.794 416.196 2341.92* 2323.928 2366.966 3262.135 2629.740 444.635 1 **.47* **3.131 793.833 69.716 722.147 801.229 761.660 33.919 52.361 267.262 139.832. 151.959 C _Btu__________ Standard Deviation 57. (n* 47.230 39.949 33.134 33.Ill 13.304 30.2*3 43.393 44.067 29.440 47.476 14.777 17.3*2 27.984 72.7*4 7.337 14.011 24.124 21.169 1.795 10.309 94.704 37.3*7 39.477 0 Kean Standard Deviation 209.947 179.981 pn.m 250.260 107.39* 31.032 111.313 145.430 171.771 220.790 183.101 29.131 V>.073 97.969 73.906 31.8*9 47.DW 93.7J1 11.13" 14.144 10.403 6.105 12.754 9.401 42 -14a- 43 T o ta l A irborne Dust (G ra vim e tric) and A irborne Asbestos F ib e r C oncentrations: Scoring -15- IV. Pounding A 4-inch section of insulation (recovered from the Bandsawing) was placed in a 4-inch wide by 9 1/2-inch long by 12-inch deep (internal dimensions) box, and a 4-foot long section of 1/2-inch (I.D.) iron pipe (weight 4 lb. 2 oz.) dropped through a guide section of 3-inch pipe a distance of 16 Inches onto the rounded outer surface of the pipe covering. This drop was repeated 50 times, and then the pumps started and 5-minute air samples taken. The process was repeated twice more, using the same piece of pipe covering throughout for each product. As usual, background samples were taken with each product change. Figure XVIII shows this experimental arrangement; the locations of the air samples are shown in Figures III and IV, p. 6a. ncun mu Plaa Pfruodinc lost Aa4 lad Arrao|Mat 44 16 Results (Pounding) Table 7 gives the results from this experiment, as do Figures XIX and XX. Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from Pounding: All Products* Tabla 7. Prodact ,rvhrrm f/a5 A Niia Standard OtvlitlM 2.10 *.*17 2.630 j.239 1,020 Naas Studird Otrlctlen 2.570 2.570 10.708 5.347 nrn Nfia Standard Dsvtatlov *.785 1.28) 4.4*7 7.155 1.7*6 Naan Standard Darlat Ion i.**i 1.571 0.64) 1.757 1.5)5 (aaplaa ov. c/al 1.060 1.(8) 2.754 1.444 2.5*7 34.725 ..........1.4*2 3.0)6 6.607 11.477 Horizontal f/.i r/.K5) 2.10* 7.402 4.247 2.341 9.649 4.956 2.81*. 7.751 5.*15 5 67) 2.970 2.430 7.807 6.399 10.701 2.67) 5.10* 3.080 10.132 5.426 5*01 3.009 0.275 1.00L 0 .463 0.463 2.482 0.29) 2.415 1.057 3.706 V 0.280 2.299 0.054 4.6)) 0.260 1.626 1.626 0.757 0.75) J.*I* 1.42* *4.4*9 29.660 55.*17 47.7)3 26.009 23.906 46.806 32.816 41.022 37.000 1.877 0.825 1.414 1.274 2.627 1.752 2.346 1.163 1.557 . 1.777 t .617 0.561 *7.413 31.417 37.447 49.907 28.737 27.037 49.625 54.753 65.132 77.108 9.027 1.018 7.0)1 1.412 2.6)0 2.264 2.*23 1.581 1.975 1.37* 1.067 0.520. 0.1)7 5.811 4.671 5.10* 4,1)2 1.5*4 4.518 4.164 0.334 *.818 JTJII-------- 7.787 2.214 5.0*1 4.519 2.*73 2.690 5.777 1.09) 3.777 1.766 1.427 3.771 2.1*8 1.271 * 4.6*0 2.463 2.7*4 3.434 2.266 3.366 3.417 1.110 45 C r tT tM tr U (Hg/HT) flC V U r n f#uo41ag ( f / a l J) 16a- T o ta l A irb o rn e Dust (G ra v im e tric ) and A irb o rn e Asbestos F ib e r C o n ce n tra tio n s: Pounding -17- Dlscusslon of Results It is clear from the foregoing results that Product B produces significantly more airborne asbestos fibers from similar manipulations than any of the other products. This is shown by Figure XXI, where the ranges and means of all results (except those from the scoring) have been accumulated. IccnuLaUd Ra|(0 tad Ncim fr all cn^lu (txeipc scorlai) ncoiz zzz in rtowcn 47 -18- One queBtion which has not yet been answered is: "What are the sizes of the airborne asbestos fibers produced from these products?" Answer to this question is provided by an examination of the diameters of the asbestos fibers counted on the Personal filter samples for all products, (for the hand-sawing portion of the pipe-covering operation) in Table 8. Table 8 Asbestos Fiber Diameters from Personal Samples Product 50Z less than (geometric mean) 90Z less than geometric standard deviation A 1.45 Vm B 1.7 ym C 1.6 ym D 1.6 ym 2.8 pm 3.0 ym 3.0 ym 2.9 ym 1.66 1.59 1.60 1.56 Another concern which arises from an examination of the data is with the total gravimetric concentrations of airborne particulate matter which were measured. In many cases, these were orders of magnitude above the proposed Threshold Limit Value of 10 mg/m^ for inert dusts. This Indicates that, even if these products contained no asbestos, their use in enclosed spaces similar to our test chamber would produce concentrations of airborne dust which would be unacceptable. Analysis of the "respirability" of these dust concentrations (from the comparison of the Elutriator samples with other samples) is proceeding and will be the subject of future publications It must be understood at this point that the results of this study are 48 -19- subject to several qualifications. Perhaps the most important of these is that exposures of workers in the actual application and manipulation of these materials would often be different than those found here. Higher concentrations would be postulated if several men were working within an enclosed space, or if the available space was more confined. More likely, actual concentrations (as we have measured in many diverse Job situations) would be lower due Co slower pace of the work, natural ventilation, or greater space available for dilution. Another qualification is that the Pounding and Scoring operations performed here are not strictly comparable to actual trade practices. The pounding operation was (in essence) a destructive test; most applications would not be accompanied by repetitive blows 'concentrated on a small area of the surface of a product. However, (despite the fact that this is considered a poor trade practice) some Insulators will not consider an installation complete on a large vessel until they have thoroughly pounded the applied Insulation material, raising clouds of visible dust. Scoring is ordinarily done to facilitate "bending" of flat blocks of insulation to fit a curved surface. Product B is not supplied in flat blocks, and it is therefore unlikely that scoring will be done to this product. But mechanization is proceeding in this trade (as in others) and the use of power saws of various sorts is becoming more common for tasks which have traditionally been done by hand. A'third Important qualification affecting the application of the results found here is due to our sampling method. None of the data are 43 time-weighted average concentrations; they represent "peak" exposures. Nevertheless, the relative hazard judgements implied by the different concentrations found are valid, since the time limitations were imposed by the products themselves. That is, a product which is easier to work will require less time for installation of a given segment, but in actual practice this will mean that the insulator will install more of these segments. He will thus be exposed to more repetitions of peak exposures, not necessarily to a lower time-weighted average exposure. Further, the purported ease of fabrication of Product B was not found in our tests. This can be seen from the times shown in Figures V, XII, and XV. It Is worthy of particular note that Product B was the only product for which the 3-minute tear-out time limit was not met. This was due to the "springiness" of this product; the wires rebounded from the hatchet blade instead of breaking cleanly. Our hypothesis that the product containing the highest percentage of asbestos might not produce the greatest concentrations of airborne asbestos fibers has not been validated by this study. From the raw data, it would appear that our conclusion must be: "The concentrations of airborne asbestos fibers are directly related to the percentage of asbestos in the parent products." We do not believe this to be a general rule; we suspect that design of materials to reduce airborne dust production is possible and that factors not apparent to us at this point may eventually prove to be of more importance in this design than the percentage of asbestos. Our examination of the products used in this study Is continuing; we hope at some future time r>o to be able (within reasonable bounds of certainty) to predict airborne asbestos fiber production from given operations on specific products. This prediction would arise from consideration of such factors as density, relative strength of the bonds between the asbestos fibers and the matrix, resistance to specific kinds of applied forces, and others. From a practical point of view, it is clear that none of these products should be used without industrial hygiene control. Any cutting operation should be accompanied by controls on the dust arising from that operation, preferably controls (such as local exhaust ventilation) which would prevent the dissemination of dust into the breathing zone of the workman doing the cutting, or the breathing zones of those working near him. Where this cannot be done, personal respiratory protection is a poor (but necessary) second choice. Conclusions 1. A method by which construction materials can be tested for their potential for airborne dust generation has been developed. 2. Four insulation materials containing asbestos have been tested using the method; the material containing the highest percentage of asbestos produced the highest concentrations of airborne asbestos fibers under conditions of the test. 3. Measurement of the total airborne dust concentration is a "poor" indicator of the airborne asbestos fiber concentration. 4. Comminution (by hand or mechanical methods) of any of these products within confined spaces may result in airborne asbestos fiber 51 concentrations orders of magnitude greater than the proposed ceiling value of the Threshold Limit Value. 52 REFERENCES 1. Durkan, T. M.: 3rd Symposium on Silicosis, edited by B. E. Kuechle, Employers Mutual Liability Insurance Co., Wausau, Wisconsin, 1938, pp. 66-69. 2. Drinker, P. and Hatch, T. F.: Industrial Dust, McGraw Hill Book Co., New York, 1954, p. 83. 3. Balzer, J. L. and Cooper, W. C.: The Work Environment of the Insulating Worker, Amer. Industr. Hyg. Assn. J., May-June, 1968. 4. Lanza, A. Z.: Asbestosls, J.A.M.A. 106:368-369, 1936. 5. Selikoff, I. J., Churg, J., and Hammond, E. C.: Asbestos Exposure and Neoplasia, J.A.M.A. 188:22-26, 1964. 6. Edwards, H. and Lynch, J. R.: The Method Used by the Public Health Service for Enumeration of Asbestos Dust on Membrane Filters, Annals of Occ. Hyg. 11:1-6, 1968. / 53