Document 3NEX5jQDNmdLRom9QYQ5YL57x

Federal Register/ Vol.'Si;'f)o. 119 / Friday, June 20, 1988 / Rules and Regulations 22759 change the filter elements whenever an for laundering shall inform such person anthophyliite. or actinolite. The increase in breathing resistance is of the requirement in paragraph (i)(2)(i) decontamination area shall consist of an detected and shall maintain an adequate of this section to effectively prevent the equipment room, shower area,-and clean supply of filter elements for'this release of airborne asbestos, tremolite, room in series. The employer shall - purpose. anthophyliite, actinolite, or a ensure that employees enter and exit the (iii) Employees who. wear respirators combination of these minerals in excess regulated area through the shall be permitted to leave work areas of the exposure limit prescribed in decontamination area. to wash their faces and respirator paragraph (c) of this section. (ii) Clean room. The clean room shall facepieces whenever necessary to (3) Contaminated clothing. be equipped with a locker or prevent skin irritation associated with Contaminated clothing shall be appropriate storage container for each respirator use. transported in sealed impermeable bags, employee's use. (iv) No employee shall be assigned to tasks requiring the use of respirators if. based on his or her most recent or other closed, impermeable containers, (iii) Shower area. Where feasible, and be labeled in accordance with shower facilities shall be provided paragraph (k) of this section. which comply with 29 CFR examination, an examining physician (4) Protective clothing for removal, . 1910.141(d)(3). The showers shall be determines that the employee will be demolition, and renovation operations. contiguous both to the equipment room unable to function normally wearing a (i) The competent person shall and the clean change room, unless the respirator, or that the safety or health of periodically examine worksuits wom by employer can demonstrate that this the employee or of other employees will employees for rips or tears that may location is not feasible. Where the be impaired by the use of a respirator. occur during performance of work. employer can demonstrate that it is not Such employee shali be assigned to (ii) When rips or tears are detected feasible to locate the shower between another job or given the opportunity to while an employee is working within a the equipment room and the clean transfer to a different position the duties negative-pressure enclosure, rips and change room, the employer shall ensure of which he or she is able to perform tears shall be immediately mended, or that employees: with the same employer, in the same the worksuit shall be immediately (A) Remove asbestos, tremolite, geographical area, and with the same seniority, status, and rate of pay he or she had just prior to such transfer, if such a different position is available! , (4) Respiratorfit testing. (i) The employer shall ensure that the respirator issued to the employee exhibits the least possible facepiece leakage and that the - respirator is fitted properly. - (ii) Employers shall perform either quantitative or qualitative face fit tests at the time of initial fitting and at least every 6 months thereafter for each employee wearing a. negative-pressure respirator: The qualitative fit testa may be used only fortesting the fit of halfmask respirators where they are permited to be wom, and shall be conducted in accordance,with Appendix C. The tests, shall be used to select replaced. (j) Hygiene facilities andpractices-- (1) General, (i) The employer shall provide clean change areas for employees required to work in regulated areas or required by paragraph (i)(l) of this section to wear protective clothing. Exception: In lieu of the change area requirement specified in paragraph (i)(T)(f). the employer may permit employees engaged in small scale, short duration operations, as described in paragraph (e)(6) of this section, to clean their protective clothing with a portable HEPA-equipped vacuum before such employees leave the area where maintenance was performed. (ii) The employer shall ensure that change areaB are equipped with anthophyliite, or actinolite contamination from their.worksuits using a HEPA vacuum before proceeding to a shower that is not contiguous to the work area; or (B) Remove their contaminated worksuits, don clean worksuits, and proceed to a shower that is not contiguous to the work area. (iv) Equipment room. The equipment room shall be Supplied with impermeable, labeled bags and containers for the containment and disposal of contaminated protective clothing and equipment. (v) Decontamination area entry procedures. (A)Ihe employer shall ensure that'employees: separate storage facilities for protective ' (2)Enter the decontamination area . facepieces that provide the required protection as prescribed in Table 1. clothing and street clothing, in accordance with section 1910.141(e). ' through the clean room; [2] Remove and deposit street clothing (1) Protective clothing--(1) General. . - (iii) Whenever food or beverages are within a locker provided for their use; The employer shall provide and require consumed at the worksite and and the use of protective clothing, such as employees are exposed to airborne (3) Put on protective clothing and coveralls or similar whole-body .. . concentrations of asbestos, tremolite, respiratory protection before leaving the clothing, head coverings, gloves, and anthophyliite, actinollte, or a clean room. ' foot coverings for any employee combination of these minerals in excess (B) Before entering the enclosure, the exposed to airborne concentrations of . . of the permissible exposure limit, the . employer shall ensure that employees asbestos, tremolite.'anthophyllite, actinolite of a combination of these employer shall provide lunch areas in which the airborne concentrations of pass through the equipment room. (vi) Decontamination area exit minerals that exceed the permissible asbestos, tremolite, anthophyliite, procedures. (A) Before leaving the exposure limit prescribed in paragraph actinolite. or a combination of these regulated area, the employer shall (c) of this section. minerals are below the action level. ensure that employees remove all gross (2) Laundering, (i) The employer shall , (2) Requirements for removal, contamination and debris from their ensure that laundering of contaminated demolition, and renovation operations-- protective clothing. clothing is.done so as to prevent the (i) Decontamination area. Except for (B) The employer shall ensure that . release of airborne asbestos, tremolite, small scale, short duration operations, employees remove their protective anthophyliite, actinollte, or a as described in paragraph (e)(6) of this clothing in the equipment room and combination of these minerals in excess section, the employer shall establish a deposit the clothing in labeled of the exposure limit prescribed in decontamination area that is adjacent impermeable bags or containers.' paragraph (c) of this section:': . and connected to the regulated area for (C) The employer shall ensure that (ii) Any employer who gives the decontamination of employees employees do not remove their : contaminated clothing to another person contaminated with asbestos, tremolite. respirators in the equipment room. GLEASON-001007