Document 3N2qjyZJ3rO8M55xakkkGJagy
subiect Asbestos Exposures from Brake Drum Work Case: 48108-3
MEMORANDUM FOR FILE
Bell Laboratories
tou; September 23, 1976 hom: G. D. Kenney
Summary:
Samples were taken at three different garages in C & P Washington telephone company to try and estimate exposures to asbestos by employees changing brakes. The concentrations found ranged from 0.04 to 0.4 fibers/cc. The present OSHA standard for asbestos is 2 fibers/cc. The samples were analyzed using the procedure of phase contrast microscopy.
Standards:
The present standard for asbestos promulgated by OSHA is 2 fibers per cubic centimeter greater than five micrometers in length (f/cc.). This two fiber limit refers to an eight hour time weighted average standard. This standard also included a ten fiber/cc ceiling concentration which is not to be exceeded.
Procedures:
Air samples for asbestos fibers were taken using the HIOSH recommended procedures.*
The fibers were collected by pulling air through small filters using a battery powered pump. The filters used were 37 milli meter cellulose ester membrane filters having a 0.8 micrometer nominal pore diameter. The sampling pumps used were Mine Safety Appliance Model G sampling pumps. The air was pulled through the filters at a rate of 1.8 liters per minute.
The filters were sent to the Kettering Laboratory for analysis. The procedure used for analysis was to count the fibers collected on the filter using a phase contrast microscope at a magnifica tion of 400 to 450 X.
* NIOSH Manual of Analytical Methods HEV.' Publication No. 75-121, 1975.
CONFIDENTIAL
003954
2
Both personal and general room air samples were collected for these operations.
Results:
The results of these samples are presented in Table I appended to the end of this report.
At the first garage the employees were changing the front brakes on a lightweight sedan, and Inspecting the rear drums. In this operation the drums and backing plate were cleaned using an aerosol consisting of common solvents. Relatively little dust was generated using this process. The excess dust in the brake drum was disposed of by dumping the dust on the floor. The excess dust laden solvent was caught in a drip pan.
The total time required to perform the job was 30 minutes.
At the second garage the operation was to change the rear brakes of a medium duty truck. This job varied from the others in that the mechanic had to pull the rear axles as well as turn the brake drums in addition to installing new brakes.
Excess dust In the brake drums was dumped in a garbage can. The remaining dust on the backing plates and in the drums was clean ed out using an aerosol mixture.
The total time required to change the brakes on this truck was about four hours.
At the third garage the employees were changing the brakes on a light van. All the dust in the drums and on the backing plates was cleaned out using an aerosol mixture.
The employee performing this work was wearing a nonapproved filter mask.
In this particular case after the brakes had been mounted on the backing plates the brake shoes were sanded or buffed using a piece of sandpaper by the employee.
The total time to complete the job was 85 minutes.
Discussion of Results:
Prom the Table I it is seen that the exposure levels do not vary great_y from garage to garage, except for the levels found in Garage H2. The most probable explanation for the lower values in this garage is, as explained before, that the work involved included operations and times where no asbestos exposure occurred. As a result these time weighted samples will be lower than found in the other garages.
CONFIDENTIAL
003955
-3-
The levels reported here agree tolerably well with those re ported by Hickish and Knight.* They reported exposures ranging from 0.03 to 1.12 fibers/cc in changing brakes on lightweight cars. The average exposure level was 0.38 fibers/cc.
The levels 'however are much lower than those reported by NIOSH.t Samples taken during the blowout of automobile drum brake assemblies, beveling of new truck brake linings and the grinding of used truck linings gave results of 10.5, 37-3, and 3.75 fibers per cubic centimeter respectively. These measurements were taken to try and get the peak levels during exposure.
The most probable explanation for the discrepancy between the results reported here and those by NIOSH is a difference in sampling times. The sampling periods were not reported in the article. If it is assumed that the samples reported by NIOSH were taken only for the time that the actual job, such as blow ing out the drum assemblies took place then the sampling period would only last for 2 to 3 minutes. Performing some calculations assuming a 3 minute sampling time and a 1.8 liter per minute flow rate only 17 fibers counted out of 100 fields would be necessary to get a concentration of 10 f/cc. The numbers of fibers counted in the samples taken here ranged from 3 to 16 fibers per 100 fields.
The most difficult result to explain is the value obtained for the ambient sample. The value for this sample Is 0.*J. The 0.4 value is the highest concentration found for any of the results.
One possible explanation would be contamination of the filters. However, blank filters, handled In the same way as the samples but through which no air was passed, did not give high values. This would eliminate the possibility of gross contamination of the filters.
Another possible explanation for these results is that the ambient sampling sites were situated so as to be in the path of the dust laden air from the garage. Both ambient sampling sites, however, were at least 75 feet from the nearest open ing to the garages and located upwind of the openings.
A third possible explanation Is that a mistake was made in the counting of these samples. A recount of the ambient sample at garage #3 by two different persons gave results of 0.38 and 0.9 fibers/cc. Although a relatively widespread exists between the numbers, such ranges are not uncommon in asbestos counting. The recounts seem to confirm that the first count is relatively accurate.
* Hickish, D. E. and Knight, K. L.: Exposure to Asbestos during brake maintenace. Ann. Occup. Hyg. 13: 17-21, 1970.
t NIOSH Issues Asbestos Dust Alert for Workers Exposed Servic ing Brakes; Ccc. Safety and Health Reporter, BNA, 5:348-49, 1975.
CONFIDENTIAL
003956
The question then is what is the significance of these ambient results. If the values are true than an argument can be made that the exposures to asbestos during a brake changing operation is no greater or even less than the employees ambient exposure. The problem is that with the present method of phase contrast microscopy it is impossible to qualify whether the fiber being counted is in fact an asbestos fiber. With the present method any particle with an aspect ratio (length of fiber to width of fiber) of 3 to 1 or greater and having a length greater than five micrometers is to be counted. Therefore it is possible that the fibers in the ambient samples and for that matter the personal and general air samples are not of the asbestosform type. With the present samples and analysis it is impossible to state whether this is true.
Bulk samples of brake drum dust were taken to try and determine if the dust contained asbestos. According to the analytical laboratories the amount of asbestos, if present in the samples, was below the analytical sensitivity of the method used. The sensitivity limit for the method as reported by the lab is 5*.
In a report by Jacko and Du Charne they reported the asbestos concentration in brake dust as about one percent.* This would explain the negative results found in the bulk samples taken here.
The final question is how do these results compare with the present OSHA standard for asbestos. The present eight hour time weighted average standard for asbestos is two (2) fibers/cc. The sample values are 'well below this level of 2 fibers/cc. Perhaps a more important question is does an exposure to asbestos exist, if so then medical examinations of the exposed employees must be initiated. With the present results an interpretation that an exposure does exist must be made.
Copy to W. J. Schreibeis G. M. Wilkening
1 Jacko, M. G., Du Charme, R. J.; Brake Emmissions: Emission Measurements from Brake and Clutch Linings from Selected Mobile Sources. EPA Report No. 68-0*4-0020, 1573
CONFir
005957
SamDle Ident*
Garage #1
Personal Sample Gen. Air Ambient
Garage #5
Personal Sample General Air
Garage #5
Personal Sample General Air
Table I Sample pd. Minutes
35 35 63
232 230
100 102
Concentration f/cc
0.3 0.3 0.4
0.04 0.06
0.2 0.1
CONFIDENTIAL
003958