American Society of Heating and Ventilating Engineers Guide, 193 Convection type heaters are typified by the gas-fired steam radial the gas-fired tubular heater (built in radiator form) and the floor furn The radiator types of gas-fired heaters provide an economical formG heating apparatus for intermittently heated spaces, such as stores, sm<f churches, and some types of offices and apartments. Since they give si the greater portion of their heat by convection they do not produce"! hot spot within the room arid are therefore capable of being operas under thermostatic control. The floor furnace is a convection type heaw, that is hung underneath the floor. It is generally installed with a dupwj register having a warm-air outlet and a cold-air return, so that comply recirculation is secured. ' SELECTION OF GAS BOILERS While gas-burning equipment can be and usually is so installed as to be! completely automatic, maintaining the temperature of rooms at a prej determined and set figure, there are in use installations which are manuals controlled. Under such control the temperature variations are consider; able because the human body does not react as readily to temperature changes as does a thermostat, and a greater boiler output is required quickly to regain comfortable temperatures. Experience has shown that in order to effectively overcome the starting load and losses in piping, a manually-controlled gas boiler should have an output as much as 100 per cent greater than the equivalent standard cast-iron column radiation which it is expected to serve. Boilers under thermostatic control, however, are not subject to such severe pick-up or starting loads. Consequently, it is possible to use muctf lower selection or safety factors. A gas-fired boiler under thermostatic control is so sensitive to variations in room temperatures, pressure of steam, or temperature of water, that in most cases a factor of 25 per'cent is eminently sufficient for pick-up load. The factor to be allowed for loss of heat from piping, however, must vary somewhat, the proportionate amount of piping installed being con-, siderably greater for small installations than for large ones. Consequently/' a selection factor for thermostatically controlled boilers must be variable. Table 5 gives selection factors to be added to the installed steam radiation under thermostatic control. They have been established by experience and are recommended by the American Gas Association. Appliances used for heating with gas should bear the Approval Seal of the American Gas Association Testing Laboratory. Installations should be made in accordance with the recommendations shown in the publica tions of that Association. RATINGS FOR GAS HEATING APPLIANCES Since a gas appliance has a heat-generating capacity that can be pre dicted accurately to within 1 or 2 per cent, and since this capacity is not affected by such things as condition of fuel bed and soot accumulation, $ makers of these appliances have an opportunity to rate their product in exact terms. Consequently all makers give their product an hourly B.t.u. rating. This is the amount of heat that is available at the outlet of a 278 Chapter 17--Gas Heating Wk'.' jLg form of steam or hot water, or at the bonnet of the furnace JgpP? 0f warm air. The output rating is in turn based upon the pMag. ut rating which has been approved by the American Gas Asso- jB-fft1- ,, Laboratory and upon an arbitrary efficiency which has ppk^ssigned by that Association. Wm*., ^se of boilers, the rating can be put in terms of square feet of P^ alent ^jirect radiation by dividing it by 240 for steam, and 150* for EgSt^his gives what is called the American Gas Association rating, and PPfT manner in which all appliances approved by the American Gas Laboratory are rated. To use these ratings it is only necessary E^erease tjjC calculated heat loss or the equivalent direct radiation load appropriate amount for starting and piping, and to select the boiler furnace with the proper rating. fcW*'?It might be stated at this point that the rating given by the American ^'Gos Association Laboratory is not only a safe rating when considered the standpoint of capacity, but is also a safe rating when considered ''from the standpoint of physical safety to the owner or caretaker. The Table 5. Selection Factors for Gas Boilers SoJtcnoH Factob. (Pis C*m) 500 800 1,200 1,600 2,000 3.000 4.000 and over 56.0 54.0 51.0 48.0 45.0 42:5 40.0 rating that is placed upon an appliance is limited by the amount of gas that can be burned without the production of an amount of carbon monoxide that would be dangerous to human life. This same limitation ./ applies to all classes of gas-consuming heating appliances that are tested pand approved by the Laboratory. Gas boilers are available with ratings to 14,000 sq. ft. of steam, while furnaces with ratings up to about 500,000 B.t.u. per hour are available. CONTROL FEATURES One feature of the piping installation that adds to the satisfactory service rendered by gas boilers is provision for adequate and rapid venting of the air from steam heating systems. If air leaks into the steam dis-. tribution system during the period that the gas is turned off, and then vents out slowly when the thermostat calls for heat, the result will be a 3-further cooling of the premises between the time that the thermostat ;J`calls for heat and the time that steam reaches the radiators. A freely venting steam or vapor system gives maximum economy and minimum .temperature variation. When gas boilers are attached to existing heating value of 160 for the heat-emission of hot-water radiatota is used by many engineers. 279 S