June 29, 1979 Page 1
All U. S. Site Location Managers
Final regulations implementing the Toxic Substances Control Act (TSCA) banning the manufacture, processing, distribution in commerce and use of polychlorinated biphenyls (PCBs) were published in the Federal Registered on May 31, 1979, and become effective on July 2, 1979. This action will prohibit the manufacture, processing and distribution in commerce unless specifically exempted, and "non-totally enclosed" (open to environment) uses of PCBs unless specifically authorized by the EPA. "Totally enclosed" uses (contained and therefore exposure to PCBs is unlikely) will beallowed to continue for the life of the equipment. Transformers, capacitors, and magnets are considered totally enclosed.
The new regulations are not significantly different from previous EPA action. Two exceptions are as follows:
1. All Spill Prevention Control and Countermeasure (SPCC) Plan provisions requiring reporting to the Coast Guard and/or EPA have been dropped. The regulation does not exempt any person from the actions and liability of other statutory authorities including Section 8(e) of TSCA, Section 311 of the Clean Water Act and RCRA. While the SPCC plan reporting provisions have been lifted from all sections of this final rule, a SPCC Plan is required for storage containers for liquid PCBs awaiting disposal.
2. The concentration of PCBs in substances which constitute a PCB mixture has been reduced from 500 ppm to 50 ppm. The new definition is, PCBs subject to these regulations are those substances containing PCBs at a level of 50 ppm or more.
One exception to this definition is waste oils. Waste oils cannot be used as sealants, coating or dust control agents if they contain any detectable concentrations of PCBs.
Transformer fluids do not require labeling when the level is known to be below 500 ppm PCBs. Also, analysis is not required unless there is reason to believe a transformer contains PCB dielectric fluid or otherwise has 500 ppm PCB or greater, it may be assumed to have 50 to 500 ppm PCB.
The regulations do specifically address PCBs stored for disposal but not for use. It is highly recommended that all of the requirements for PCBs stored for disposal be followed when dealing with PCBs stored for use.
055X808
PCB-ARCH0747332
000000231.000001
June 29, 1979 Page 2
The regulations specifically require annual analysis of fluids in heat transfer and hydraulic systems to determine PCB levels.
To facilitate the uniformity in obtaining information to assess the PCB situation and to assist your location in complying with the new regulation, a packet of materials is enclosed. They are:
I. Synopsis of the Regulation XI. An Index to the Regulation III. An EPA report dealing with
the regulation. IV. The Regulation.
questions
and
answers
concerning
Although a synopsis of the regulation is provided, it is strongly recommended that the full regulation be thoroughly read and under stood by personnel responsible for its implementation.
Also the EPA Report, "EPA's Final PCB Ban Rules: Over 100 Questions & Answer to Help You Meet These Requirements" is provided for information only. This document is not part of the regulations and does not impose additional rules on our facilities. The answers are merely documented EPA 'opinion' on the regulations.
The forms needed for record keeping were distributed previously and for this reason have been omitted from this packet. Additional labels are available from the previously publicized source.
PCB-ARCH0747333
000000231.000002
SYNOPSIS OP PCB REGULATIONS This synopsis is not intended to be a substitute for the regulation. The information should be used to help gain a quick overview and as a guide or reference in connection with use of the regulations (FR 44 (106) 5/31/79, pp 31514 to 31568).
0551810
PCB-ARCH0747334
000000231.000003
June 29, 1979 Page 1
TOXIC SUBSTANCES CONTROL ACT - SECTION 6(e) PCB MARKETING AND DISPOSAL RULE
I.
GENERAL
Rule promulgated on May 31, 1979 and effective (and superseding current PCB Disposal Rules) on July 2, 1979 (44 FR 31514) .
Any appeals of rule must be filed with appropriate Federal court of appeals before July 31, 1979 (TSCA - Section 19).
II.
PENALTIES
Civil and Criminal - Any person who violates an exemption or authorization may be liable for a civil penalty of up to $25,000 per day of violation. In addition, a person who knowingly or willfully violates an exemption or authorization may also be fined up to $25,000 per day of violation and may be imprisoned for up to one year, or both (TSCA - Section 16).
III. ENFORCEMENT
Injunctions r Any person who violates an exemption or authori zation may also be subject to court injunctive enforcement relief, both to restrain his violation of TSCA and to compel him to follow the exemption or authorization (TSCA - Section 17).
IV.
RECORD KEEPING
See attached memorandum from P.H.S. to M.A.P., dated December 19, 1978.
See Annex VI, Section 761.45.
055181*
PCB-ARCH0747335
000000231.000004
P. H. Smith - E2NE
December 19, 1978 EPA TOSCA-PCB Marking and
Disposal Inspection Manual
M. A. Pierle
June 29, 1979 Page 2
D. E. Cayard W. R. Corey N. B. Galluzzo P. C. Krizov J. E. Lipe C. T. McGregor R. S. Nelson P. S. Park J. C. Weber
You have requested a review of Section 1 - Legal Authority - of the above. In Section 1, the EPA instructs its inspectors to enter, at reasonable times, premises covered by the PCB marking and disposal regulation and inspect, copy, photograph and sample matters bearing upon whether the regulation requirements have been met by the inspected establishment. The EPA references Section 11 of the Toxic Substances Control Act ("Act") as authority for these instructions.
Section 11 of the Act, in essence, authorizes the Administrator of the EPA, or his duly authorized representative, to enter premises covered by the PCB regulation and inspect records, files, papers, processes, control and facilities covered by the PCB regulation to determine compliance. Read literally. Section 11 mentions only inspection and does not seem to cover such matters as sampling, copying records or photographing the premises. On the other hand, the legislative history tends to support the EPA interpretation, stating that the inspection right in Section 11 is intended to permit inspectors to record the results of inspection, for example, by photocopying records to photographing the premises.
Notwithstanding the legislative history, in the event a request is made to copy or photograph information or facilities, the inspector should be urged to do so in a manner that avoids dis closure of confidential information. For example, confidential information on a paper to be copied could be covered, or a photo graph of facilities could be taken from an angle that does not disclose confidential information. If an inspector continues to insist upon being allowed to copy confidential information or photograph confidential facilities, he should be requested to put the request in writing for consideration by management.
Peter H. Smith RETYPED FROM ORIGINAL FOR REPRODUCTION CLARITY
0591812
PCB-ARCH0747336
000000231.00000!
DEFINITIONS - PCB REGULATIONS
June 29, 1979 Page 3
"Capacitor" means a device for accumulating and holding a charge of electricity and consisting of conducting surfaces separated by a dielectric. Types of capacitors are as follows:
1. "Small Capacitor" means a capacitor which contains less that 1.36 kg (3 lbs) of dielectric fluid.
2. "Large High Voltage Capacitor" means a capacitor which contains 1.36 kg (3 lbs) or more of dielectric fluid and which operates at 2000 volts a.c. or above.
3. "Large Low Voltage Capacitor" means a capacitor which contains 1.36 kg (3 lbs) or more of dielectric fluid and which operates below 2000 volts a.c.
"Chemical Waste Landfill" means a landfill at which protection against risk of injury to health to the environment from migration of PCBs to land, water, or the atmosphere is provided from PCBs and PCB items deposited therein by locating, engineering, and operating the landfill as specified in 761.41.
"Disposal" means to intentionally or accidentally discard, throw away, or otherwise complete or terminate the useful life of PCBs and PCB items. Disposal includes actions related to containing, transporting, destroying, degrading, decontaminating, or confining PCBs and PCB Items. Disposal includes actions related to containing, transporting, destroying, degrading, decontaminating, or confining PCBs and PCB Items.
"Fluorescent Light Ballast" means a device that electrically controls fluorescent light fixtures and that includes a capacitor containing 0.1 kg or less of dielectric.
"incinerator" means an engineered device using controlled flame combustion to thermally degrade PCBs and PCB Items. Examples of devices used for incineration include rotary kilns, liquid injection incinerators, cement kilns, and high temperature boilers.
"Leak" or "leaking" means any instance in which a PCB
Article, PCB Container, or PCB Equipment has any PCBs on
any portion of its external surface.
,...
0551813
PCB-ARCH0747337
000000231.000006
June 29, 1979 Page 4
"PCB" and PCBs" mean any chemical substance that is limited to the biphenyl molecule that has been chlorinated to varying degrees or any combination of substances which contains such substance, (see 761.1(b) Applicability
for applicable concentrations of PCBs). PCB and PCBs as contained in PCB items are defined in 761.2(x).
"PCB Article" means any manufactured article, other than a PCB Container that contains PCBs and whose surface(s) has been in direct contact with PCBs. "PCB Article" includes capacitors, transformers, electric motors, pumps, pipes and any other manufactured item (1) which is formed to a specific shape or design during manufacture, (2) which has end use functions(s) dependent in whole or in part upon its shape or design during end use, and (3) which has either no change of chemical com position during its end use or only those changes of composition which have no commercial purpose separate from that of the PCB Article.
"PCB Article Container" means any package, can, bottle, bag, barrel, drum, tank or other device used to contain PCB Articles or PCB Equipment, and whose surface(s) has not been in direct contact with PCBs.
"PCB Container" means any package, can>bottle, bag, barrel, drum, tank, or other device that contains PCBs or PCB Articles and whose surface(s) has been in direct contact with PCBs.
"PCB Equipment" means any manufactured item, other than a PCB Container or a PCB Article Container, which contains a PCB Article or other PCB Equipment, and includes micro wave ovens, electronic equipment, and fluorescent light ballasts and fixtures.
"PCB Item" is defined as any PCB Article, PCB Article Container , PCB Container, or PCB Equipment, that deliberately or unintentionally contains or has as a part of it any PCB or PCBs at a concentration of 50 ppm or greater.
"PCB Transformer" means any transformer that contains 500 ppm PCB or greater.
"PCB-Contaminated Transformer" means any transformer
that contains 50 ppm or greater of PCB but less than
.
500 ppm PCB (See S 761.31(a)(5) for provisions permit
ting reclassifying PCB Transformers to PCB-Contaminated
Transformers) .
...
-2-
PCB-ARCH0747338
000000231.000007
June 29, 1979 Page 5 "Storage for Disposal" means temporary storage of PCBs that have' been designated for disposal. "Waste Oil" means used products primarily derived from petroleum, which include, but are not limited to, fuel oils, motor oils, gear oils, cutting oils, transmission fluids, hydraulic fluids, and dielectric fluids.
-3~
PCB-ARCH0747339
000000231.000008
June 29, 1979 Page 6
761,2 Definitions
1. "Disposal" means intentionally or accidentally discard, throw away or otherwise complete and terminate the useful life of PCB's and PCB items. Disposal includes actions related to containing, transporting, destroying, degrading, decontaminating or confining PCB's and PCB items.
2. "Chemical Waste Landfill" means a landfill for PCB's and PCB items as specified in Par. 761.41.
3. "Incinerator" means an engineered device using controlled flame combustion to thermally degrade PCB's and PCB items. Examples of devices used for incineration include rotary kilns, liquid injection incinerators, cement kilns, and high temperature boilers.
760.10 Disposal Requirements
1. PCB1s must be disposed of in an incinerator which complies with Annex I (Para. 761.40).
2. Mineral oil dielectric fluid from PCB contaminated trans formers containing a PCB concentration of 50 - 500 ppm must be disposed of in one of the following:
a. An incinerator which complies with Annex I (Par. 761.40)
b..
A chemical waste landfill which complies with Annex II (Par. 761.41) provided it does not exceed 500 ppm PCB and is not ignitable as described in 761.41 (b)(8)(iii) of Annex II,
c. In a high efficiency boiler meeting the detailed
specifications listed.
3. Liquids, other than mineral oil dielectric fluid containing a PCB concentration of 50 - 500 ppm shall be disposed of in one of the following:
a. An incinerator which complies with Annex I (Par. 761.40)
b. A chemical waste landfill which complies with Annex II (Par. 761.41) provided it does not exceed 500 ppm PCB and is not ignitable as described in 761.411b)(8)(iii) of Annex II.
c. In a high efficiency boiler meetinq the detailed spec ifications listed.
0551816
PCB-ARCH0747340
000000231.000009
June 29, 1979 Page 7
4. Any non-liquid PCB's in the form of contaminated soil, rags, or other debris shall be disposed of in one of the following:
a. In an incinerator which complies with Annex I (Par. 761.40).
b. In a chemical waste landfill which complies with Annex II (Par. 761.41) except liquid PCB's shall not be processed into non-liquid forms to circumvent high temperature incineration requirements.
c. It should be noted that dilution of PCB or PCB contaminated fluid is prohibited.
5. When storage is desired prior to disposal, PCB's shall be stored in a facility which complies with Annex III (Par. 761.42).
6. PCB Transformers shall be disposed of in accordance with either of the following:
a. In an incinerator that complies with Annex I (Par. 761.40).
b. In a chemical waste landfill which complies with Annex II (Par. 761.41) provided that it is drained of all liquid filled with solvent (kerosene, xylene, toluene, etc.), and allowed to stand 18 hours and then drained thoroughly with proper disposal of the liquid.
7. PCB Contaminated Transformers shall be disposed of by draining all free-flowing liquid from the transformer.and proper disposal of liquid. The disposal of the drained transformer is not regulated by this rule.
8. PCB Capacitors
.
a. PCB Small Capacitors (less than 3 lbs. of dielectric fluid) may be disposed as municipal solid waste.
b. PCB Large High or Low Voltage Capacitors (more than 3 lbs. of dielectric fluid) may be disposed in an Incinerator that complies with Annex I (Par. 761.40); or until 1/1/1980 in a chemical waste landfill which complies with Annex II (Par. 761.41).
9. Other PCB Articles must be disposed of in accordance with either of the following:
a. In an incinerator that complies with Annex I (Par. 761.40).
b. In a chemical waste landfill that complies with Annex II (Par. 761.41) provided all free-flowing liquids have been thoroughly drained from the articles and the--drained liquids disposed of in an incinerator that complies with Annex I (Par. 761.40).
10. PCB Containers, unless decontaminated in compliance with Annex IV (Par. 761.43), shall be disposed of in accordance with
0551817 ^
PCB-ARCH0747341
000000231.00001
June 29, 1979 Page 8
the following: a. In an incinerator which complies with Annex I (Par. 761.40).
b. In a chemical waste landfill that complies with Annex II (Par. 761.41) if first drained of all free-flowing liquids and the PCB liquid disposed in an incinerator that complies
with Annex I (Par. 761.40).
11. '
Any PCB container containing PCB's at a concentration less than 500 ppm in a liquid state shall be drained and the container disposed as municipal solid waste and the liquid disposed in an incinerator that complies with Annex I (Par. 761.40).
12.
Spills and other uncontrolled discharges of PCBs constitute the disposal of PCBs. PCBs resulting from spill clean-up and removal operations shall be stored and disposed of in accordance with this section (Par 761.1). In order to determine if a spill has resulted in a contamination levels that is 50 ppm of PCBs or greater in soil, gravel, sludge, fill, rubble, or other land based substances, the regulations suggest consulting the appropriate EPA Regional Administrator to obtain information on sampling and analysis procedures. Based on Monsanto's sampling and analytical expertise contacting EPA authorities is unnecessary. Information on sampling and analytical procedures is available within Monsanto from D. G. Glasgow of MRC's EASC located in Dayton.
This paragraph does not exempt any person from the actions and liability of other statutory authorities including Section 8(e) of TSCA, Section 311 of the Clean Water Act and RCRA. Since EPA has deleted the special notification requirements proposed in Annex VII, this final rule does not impose any new spill notification requirements.
The rules requires the use of labels which include a number to notify in case of a spill. However, the authority under the regulation does not require the Coast Guard to be notified except for loss of oil into or onto navigable waterway in accordance with the requirements of section 311 of the Clean Water Act. Notification of the EPA Administrator is required if the spill meet the requirements of section 8(e) of TSCA. Monsanto has established a formal procedure for reporting this type information. It is suggested that the person reponsible at each plant for spill control plans notify the proper authorities, internal or external, in the event of a spill. His name and telephone number.can be added to the PCB label.
0551818
PCB-ARCH0747342
000000231.000011
June 29, 1979 Page 9
Transformers
The new PCB 'rules and regulations provide three categories for transformers. The catefories are:
1. PCB Transformer - PCB content of the dielectric fluid over 500 ppm. The transformer is assumed to be a PCB Transformer if:
A. Nameplate indicates PCB.
B. Owner has reason to believe the transformer contains PCB dielectric fluid.
C. Test has shown over 500 ppm PCB is dielectric fluid.
Unless there is reason to believe a transformer contains PCB (askarel) dielectric fluid or otherwise has 500 ppm PCB or greater, for the reasons given above, it may be assumed to be a PCB contaminated transformer.
2. PCB contaminated transformer - PCB content of the dielectric fluid is 50 ppm or greater but less than 500 ppm.
3. Non PCB Transformer - PCB content less than 50 ppm. No transformer is a non PCB transformer unless its dielectric fluid has been tested or otherwise verified to contain less than 50 ppm PCB.
The differences cited above are given as a basis for the continued use, servicing and rebuilding of transformers which may contain PCBs.
The objective of the rules are to allow continued use of transformers for their full useful life.
The rules related to servicing and rebuilding based on the transformer categories given above are:
1. PCB Transformers - Routine servicing (testing the dielectric fluid, filtering the fluid and replacing gaskets) is permitted. Any servicing (including rebuilding) that involves removing the coils from the casing is prohibited.
However a PCB Transformer may be converted to a PCB Contaminated Transformer by draining, refilling the unit with a non PCB dielectric fluid. The fluid must be tested after at least three months of in-service use to verify PCB levels are below 500 ppm.
PCB-ARCH0747343
000000231.00001
June 29, 1979 Page 10 2. PCB contaminated transformer-both routine servicing and rebuilding are permitted for transformers in this classification, including PCB transformers which have been reclassified as PCB contaminated transformers. 3. Non PCB Transformer - this classification for a transformer, based on verification that the non PCB dielectric fluids contain less than 50 ppm PCBs, is to exempt the fluid from PCB disposal requirements established for mineral oil which contains more than 50 ppm PCB. However, no testing is needed if the mineral oil will be burned in a high efficiency boiler or disposed of in any other way permitted for mineral oil contamined with PCB up to 500 ppm. The labeling requirements for transformers have not been changed significantly. Only PCB transformers, containing 500 ppm or greater PCB, are required to be labeled. PCB contaminated transformers, containing between 50 and 500 ppm PCB, are not required to be labeled. An unmarked transformer is automatically assumed to be a PCB contaminated transformer. However, if a transformer has no nameplate information but there is a reasonable suspicion that the PCBs may be present above 500 ppm . . . the transformer should be labeled as a PCB transformer until the PCB content can be verified.
0551819.01
PCB-ARCH0747344
000000231.00001
June 29, 1979 Page 11
PCB BAN - HEAT TRANSFER AND HYDRAULIC FLUIDS. PAGES 31550, 31551
It is EPA's intent to have residual levels of PCB's below 50 ppm by July 1, 1984 without causing major disruptions to system oper ation and avoiding creation of large volumes of PCB contaminated wastes in 1979/1980.
Accordingly, use of systems is authorized until July 1, 1984. PCB levels must be checked once per year and if above 50 ppm the system must be drained and refilled with non PCB fluid within 6 months of the test. The first test must be complete by November 1, 1979. Subsequent annual tests must be made at least 3 months after any draining/refilling to permit PCB level to reach equil ibrium.
Heat transfer systems involved with production of food, drugs,
cosmetics or devices (defined by section 201 of Federal Food,
Drug and Cosmetic Act - does not include soap) must be below 50
ppm by November 1, 1979.
Heat transfer systems and hydraulic systems containing more than 500 ppm PCB had to have been 'marked' by July, 1978. Those con taining 50-500 must be marked by October 1, 1979.
The rules disposal sections offer 2 additional disposal options for synthetic fluids containing 50-500 ppm. (a) Use of a high efficiency boiler for which detailed specifications are set out and the use of which must be covered by Regional EPA approval and (b) Landfill in Hazardous Chemical landfill provided their permit provides for difficult to ignite liquid wastes. For landfill, liquids must be stabilized with absorbents prior to landfill.
Testing SPCC's
Note that isomer levels in used heat transfer fluids will not match those in Aroclors sold prior to 1971 as heat transfer fluids; some isomer rearrangements take place. You may need to report PCB levels against one or more standards, e.g. Aroclor 1248/1221. MRC EASC's Laboratory in Dayton is capable of performing the PCB tests. Contact D. G. Glasgow in Dayton for details. The proposed PCB control and containment plan provi sion have been cancelled but SPCC's required under section 311 of Clean Water Act (FR 3927G Sept. 1.78) must deal with PCB's at using locations.
Packaging
Samples and product for disposal. See packaging section.
Storage for Disposal
See pages 31554 - 31556
0551620
PCB-ARCH0747345
000000231.000014
June 29, 1979 Page 12 Fluid Spills .Discuss While the heat transfer and hydraulic sections parallel each other, there are minor differences. Hydraulic fluids may be processed and distributed in commerce for filtering, distilling or otherwise removing PCB's. This is because PCB's can be separated from phosphate esters more efficiently than from heat transfer base stocks. Companies involved in such PCB reduction must have an exemotion after July 1, 1979.
PCB-ARCH0747346
000000231.000015
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
June 29, 1979
STANDARD NO.
lisue
*______ of
I
| o.t.
6 6/79
GENERAL PACKAGING REQUIREMENTS FOR
POLYCHLORINATED BIPHENYLS (PCB'S) SHIPPED BY ANY MODE
INTRODUCTION
The purpose of this procedure is to provide proper marking, labeling and packag ing instructions for sample and drum shipments of Polychlorinated Biphenyls (PCB's). Adherence to the requirements contained herein will achieve package protection and insure confinement in the event of internal package failure during transit*
DEFINITIONS
These definitions are extracted from the Environmental Protection Agency 40 CFR Part 761 as published in final rule form in the Federal Register Volume 44 No. 106, Thursday, May 31, 1979.
A. PCB and PCB's means any chemical substance that is limited to the biphenyl molecule that has been chlorinated to varying degrees or any combination of substances which contains such substance.
B. PCB ARTICLE means any manufactured article other than a PCB Container that contains PCB's and whose surface(s) has been in direct contact with PCB's. PCB Article includes capacitors, trans formers, electric motors, pumps, pipes and any other manufactured item:
(1) Which is formed to a specific shape or design during manufacture,
(2) Which has end use function(s) dependent in whole or in part upon its shape or design during end use, and
(3) Which has either no change of chemical composition during its end use or only those changes of composition which have no commercial purpose separate from that of the PCB Article.
C. PCB ARTICLE CONTAINER means any package, can, bottle, bag, barrel, drum, tank or other device used to contain PCB Articles or .PCB Equipment, and whose surface(s) has not been in direct contact with PCB's.
0,%1S22
PCB-ARCH0747347
000000231.000016
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
STANDARD NO.
June 29, 1979 Page 14 VIII-A"!
Pao 2ol6 1
I Data 6/79
D. PCB CONTAINER means any package, can, bottle, bag, barrel, drum, tank, or other device that contains PCBTs or PCB Articles and whose surface(s) has been in direct contact with PCB's.
E. PCB EQUIPMENT means any manufactured item, other than a PCB Container or a PCB Article Container, which contains a PCB Article or other PCB Equipment, and includes microwave ovens, electronic equipment, and fluorescent light ballasts and fixtures.
F. PCB ITEM is defined as any PCB Article, PCB Article Container, PCB Container, or PCB Equipment, that deliberately or unintentionally contains or has as a part of it any PCB or PCB's at a concentra tion of 50 ppm or greater.
G. MARK means the descriptive name, instructions, cautions, or other information applied to PCB's and PCB Items, or other objects subject to these regulations.
H. MARKED means the marking of PCB Items and PCB's storage areas and transport vehicles by means of applying a legible mark by painting, fixation of an adhesive label, or by any other method that meets the requirements of these regulations.
I. DISPOSAL means to intentionally or accidentally discard, throw away, or otherwise complete or terminate the useful life of PCB's and PCB Items. Disposal includes actions related to containing, transporting, destroying, degrading, decontaminating, or confining PCB's and PCB Items.
J. TOTALLY ENCLOSED MANNER means any manner that will ensure that any exposure of human beings or the environment to any concentration of PCB's will be insignificant; that is, not measurable or detectable by any scientifically acceptable analytical method.
MATERIAL REQUIREMENTS
1. Strong outside container.
- Fiberboard box (DOT Spec. 12A, 12B) - Wooden box (DOT Spec. 15A, 16A) - Metal drum (DOT Spec. 5B (tight head), 17C (full open head),
37A (full open head).
2. Adequate inside container sized to quantity to be shipped.
- Glass, earthenware or compatible plastic bottles, or - Metal pails or cans.
PCB-ARCH0747348
000000231.00001
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
STANDARD NO.
June 29, Page 15
VIII-A-1
1979
*a*------ 3------ of
6
lssu
1
Date 6/79
3. Roll of 12" wide, 1/4" thick Kimpak, vermiculite, or other material of equivalent absorbing and cushioning properties.
4. Plastic bag (1-2 mil) of sufficient size to encase Kimpak wrapped inside container. Plastic material (PE, PVC, etc.) must be impervious to the sample material.
5. Plastie (wire sandwiched in paper or plastic, similar to those used on bread wrappers).
6. Labels (available from Labeling Section in St. Louis).
- Product sample label or multipurpose sample label. - Leakage Alert label for all liquid samples.
7. Cel-O-Seal tape or equivalent.
PACKAGING PROCEDURE
A. General
1. Use containers which must:
- Have a minimum outage of 2% upon filling so as not to leak if the contents are heated to 130F, and
- Withstand an internal pressure of 15 psig.
2. Tightly secure the cap of the filled inside contains and seal with Cel-O-Seal tape or equivalent.
3. Apply the identifying label.
4. For liquids wrap the inside container with the following minimum lengths of Kimpak:
Container Size: 4 oz.
Length:
8 in.
8 oz. 15 in.
16 oz. 30 in.
32 oz. 60 in.
1 gal. 120 in.
1 Cover all faces of the inside container with equal thicknesses of Kimpak or equivalent to provide cushioning and absorbing media. If vermiculite is used cover all faces of the inside container with a minimum of 2 inches of material.
5. Place the wrapped container in the plastic bag and secure with a Plastie.
os**9*'1
PCB-ARCH0747349
000000231.00001 {
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
June 29, Page 16
STANDARD NO. VIII-A-1
1979
Pag.
4o*
l*ue
6 I Oate / 79
6. Apply the Leakage Alert label to the bag and place inside of a metal can. Fill void with vermiculite or Kimpak.
7. Place the prepared inside container in the selected outside container.
8. Tightly secure the outside container and attach the address label.
9. Stencil or otherwise permanently apply the words "THIS SIDE UP" on all containers to indicate the upward position of the inside container.
10. Mark proper shipping name on exterior of container.
11. Apply a PCB, ML1, M^2 or Ms labels to that part of the package bearing the consignee's name and address.
12. When inside container is glass, and the shipment is by mail, mark the outside of the container "FRAGILE".
B. Specific Package and Quantity Limitations
Shipments Via Surface Modes, Passenger or Cargo Aircraft
1. Use inside container which must be:
- Glass, earthenware or compatible plastic bottles not over 1 gallon capacity.
- Each bottle to be wrapped in Kimpak, or encased in vermiculite, placed in a plastic bag and must be packed in a metal can to prevent breakage and leakage.
2. Use outside container which must be:
- DOT Spec. 12A or 12B fiberboard box. - DOT Spec. 15A or 16A wooden box. - DOT Spec. 37A metal pail.
3. Stencil or otherwise permanently apply the words "THIS SIDE UP" on all containers to indicate the upward position of the inside container.
4. Use of a metal drum which must be:
- DOT Spec. 5B tight head for liquids - use as is.
- DOT Spec. 17C full open head for solids - use as is.
- -*
5. Mark proper shipping name on exterior of container.
PCB-ARCH0747350
000000231.000019
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
STANDARO NO.
June 29, 1979
Page 17 VIII-A-1
EmI-
I Oate 6/79
6. Apply appropriate PCB label, see pages 5 and 6 of this standard. 7. Complete necessary shipping papers.
PCB Containers and PCB Article Containers containing articles or equipment must be marked under the provisions of the regulations as shown in Figures 1, 2 or 3, as appropriate. (Shown in actual size)
Liquid PCB's in concentrations of 50 ppm to 500 ppm shall be marked with the ^ label as shown in figure //l.
CAOTDOT
CONTAINS
LQa
(Polychlorinated Biphenyls)
A toxic environmental contaminant requiring special handling and disposal in accordance with U.S. Environmental Protection Agency Regulations40CFR761 For Disposal Information contact the nearest U.S. E.P.A. Office.
In case of accident or spill, call toll free the
I
U.S. Coast Guard National Response Center.
800-424-6802
Also Contact_________ ..
,
Tel. No. _____________ _
FIGURE 1
0S5l8ib
PCB-ARCH0747351
000000231.000020
Monsanto
CORPORATE DISTRIBUTION DEPARTMENT
June 29, Page 18
STANDARD NO. VI11-A-1
1979
Page
^
O.
6
Issue
1
| d... 6/79
If the PCB Article for Equipment is too small to accommodate this size, the mark may be reduced in size, see figure II2.
In the event that the two labels shown in figures 1 and 2 are too large for the PCB Article, PCB Equipment, or PCB Container, the Ms label shown in figure 3 may be used.
These labels are available from the Labeling Section, St. Louis.
CAUTION CONTAINS
PCBs
(Polychlorinated Biphenyl*)
A IONIC envi'onmentol coniommom reQui'ing special hondlmg and disposal in accordance with U S {nvironmemol Protection Agency Regulations 40CTR 761 for Disposal Information contact the nearest US Pa OW-ce
in cose of accident or spm call ton free me U S Coast Guord Notional Response Center
000-424 0002 Also ContOCIN
Tel NOi
FIGURE 2
CAUTION -
CONTAINS
PCBs
CPotycNonnoied O-pnenyisi FOR PROPER OISPOSAL INFORMATION
CONTACT U.S. ENVIRONMENTAL PROTECTION AGENCY
FIGURE 3
SHIPPING PAPERS
In addition to the general information required all shipping papers, including Air Non-Restricted Articles Certificate, must have the following statement added:
"IMPORTANT
This product contains POLYCHLORINATED BIPHENYLS (PCB 's)
which some studies have shown may be persistent, an
environmental contaminant and possibly injurious to
certain forms of bird, aquatic and animal life. Prevent
.
any entry into the environment through spills, leakage,
disposal, vaporization, re-use of containers or other
wise. Spills, leakages and waste product must be
collected.
During shipment avoid spills and leakage into inland waterways and the sea.
Keep away from food, animal feedstuffs and pharmaceutieaTs."
Monsanto will furnish four large 1 (see figure //l) PCB labels to each carrier who will be transporting PCB containers that contain more than 45 kg (99.4 lbs.) of PCB's in the liquid phase or with one or more PCB transformers. The driver is to place a label on each end and side of the transport vehicle.
05518*7
PCB-ARCH0747352
000000231.000021
June 29, 1979 Page 19
PCB REGULATIONS
Page Number
I. Summary of -Rule's Organization
31515
II.
Changes in Major Definitions A. "PCB' and PCB Items"
31515 31515
B. Regulation of PCBs at the 50 ppm Concentration Level
C. Classification of Transformers Under this Rule
31516 31517
1. PCB Transformers 2. PCB Contaminated Transformers 3. Non-PCB Transformers 4. Discussion of Transformer Categories
31517 31517 31517 31517
a. Determining AppropriateCategories b. Significance of Transformer
Categories
31517 31518
D. Totally Enclosed Manner & Significant Exposure
31518
E. Sale for Purposes Other ThanResale
31518
F. Other Definitions
31518
III. Changes in Subpart B: Disposal of PCBs & PCB Items
31518
A. Mineral Oil Dielectric Fluid with 50 to 500 ppm PCB
31518
1. High Efficiency Boilers 2. Conditions for Boilers 3. Other Disposal Alternatives
31518 31519 31519
B. Other Liquid Wastes with 50 to500 ppm PCB 31519
C. Disposal of 50 to 500 ppm PCB Liquids in Chemical Waste Landfills
31520
D. Disposal of Non-Liquid PCBs in Chemical Waste Landfills
31520
E. Batch Testing of Mineral Oil Dielectric Fluid
31520
F. Other Changes in Disposal Requirements
31521
IV. Changes in Subpart C:Marking of PCBs & PCBItems
31521
V. Changes in Subpart E: Annexes
31522
A. Annex I :Incineration
31522
B. Annex II: Chemical Waste Landfills
31522
C. Annex III: Storage
,-3-1522
os***8
PCB-ARCH0747353
000000231.00002:
June 29, 1979 Page 20
PCB Regulations (continued)
VI.
1'. Container Specifications 2. Bulk Storage 3. Spill Prevention Procedures 4. Flood Protection 5. Temporary Storage
a. Revisions b. Action on Petitions to Amend Rule on
Temporary Storage Requirements
D. Annex IV: Decontamination
E. Annex VI: Records and Monitoring
Subpart D: Manufacturing Processing, Distribution in Comerce, and Use Bans
A. Probitions
1. Waste Oil Bans B. Changes in 761.30 prohibitions
31522 31523 31523 31523 31523 31523
31524 31524 31524
31524 31524 31524 31525
1. Change in Scope of Manufacturing Ban
a. Manufacturing versus Processing of PCB Items
b. Manufacture & Import of PCB Items
2. Import & Export of PCBs & PCB Items for disposal
C. Other Issues
1. PCB Impurities & Byproducts 2. Disposal of Small PCB Capacitors 3. State Preemptions VII. Relationship of 6(e)(2) to 6(e)(3) in TSCA
31525
31525 31525
31526 31527 31527 31528 31528 31528
VIII.
Authorization and Exemptions
A. Explanation of Authorizations & Exemptions
1. Manufacturing Exemptions 2. Processing & Distribution in
Commerce Exemptions B. General Changes in 761.31: Authorizations
31528 31528 31529
31529 31529
1. Reporting & Recordkeeping
2. Length of Use Authorizations 3. Changes in 761.46; Annex VII
31529
31530 31530
-2-
PCB-ARCH0747354
000000231.000023
June 29, 1979 Page 21
BCB REGULATIONS (continued)
IX.
X. XI. XII. XIII. XIV. XV.
Specific Authorizations
A,. Servicing Transformers (Other than Railroad Transformers)
31530 31530
1. General Discussion of Transformer Servicing
2. PCB Transformers 3. PCB Contaminated Transformers 4. Rebuilding PCB Transformers 5. Contents of Authorization
B., Use & Servicing of Railroad Transformers
C.. Use & Servicing of Mining Equipment
D.. Use in Heat Transfer Systems
31531 31531 31531 31532 31532
31532
31533
31534
E.. Use in Hydraulic Systems
31534
F., Use in Carbonless Copy Paper G. Pigments H. Use & Servicing of Electromagnets
31535 31535 31536
I.- Use in Natural Gas Pipeline Compressors
31536
J. Use of Small Quantities for Research S, Dev. 31536
K. Use in Microscopy
31536
PCB Activities Not Authorized by this Rule A. Manufacture of PCB Capacitors B. Manufacture of PCB Transformers
31537 31537 31537
C. Other PCB Activities
31537
Manufacutring, Processing & Distribution in Commerce of PCBs for Export
31537
Test Procedures for PCB
31538
Compliance & Enforcement
31538
Relationship of PCB Disposal Under TSCA to Hazardous Waste Disposal Under RCRA
31539
Summary of Economic Consequences A. Impact of the Statute B. Impact of the Rule
31539 31539 31539
-3-
PCB-ARCH0747355
000000231.000024
June 29, 1979 Page 22
PCB Regulations (continued)
Part 761^Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, & UseProhibitions
Subpart A - General
Section 761.1 Applicability
761,2 Definitions
Subpart B - Disposal of PCBs & PCBItems Section 761.10 Disposal requirements
Subpart C - Marking of PCBs & PCBItems
Section 761.20 Marking requirement
Subpart D - Manufacturing, Processing, Distribution in Commerce, and Use of PCBs & PCB Items
Section
761.30 Prohibitions
761.31 Authorizations
761.32 (Reserved) Subpart E - List of Annexes
Annex No. I
Section
761.40 Incineration
Annex No. II
Section
761.41 Chemical Waste Landfills
Annex No. Ill
Section
761.42 Storage for Disposal
Annex No. IV
Section
761.43 Decontamination
Annex No. V
Section
761.44 Marking formats
Annex No. VI
Section
761.45 Records and Monitoring
31542
31543 31543 31543 31545 31545 31548 31548
31548 31549 31549
31551 31551 31551 31553 31553 31555 31555 31556 31556
31556 31557 31557
PCB-ARCH0747356
000000231.000025
June 29, 1979 Page 23
PCS REGULATIONS (continued)
Part
750-
Procedures for Rulemaking Under Section 6 of the Toxic Substances Control Act;Interim Procedural Rules for Exemptions From the
PolychlorinatedBiphenyl (PCB) Processing & Distribution in Commerce Progibitions
Subpart A - General Procedural Rules for 750.1-750.9
( 750.1-750.9- Added at 42 FR 61259, Dec. 2, 1977)
Section
Subpart B - Interim Procedural Rules for Manufacturing Exemptions (1 750.10-750.21-Added at
43FR 50905, Nov. 1, 1976)
Subpart C - Interim Procedural Rules for Processing & Distribution in Commerce Exemptions
750.30 750.31 750.32 750.33 750.34 750.35 750.36 750.37 750.38 750.39 750.40 750.41
Applicability Filing of petitions for exemption Consolidation of rulemaking Notice of proposed rulemaking Record Public comments Confidentiality Subpoenas Participation in informal hearing Conduct of informal hearing Cross-examination Final rule
31558
31560
31560
31560 31560 31560 31561 31561 31562 31562 31562 35162 35162 35163 31563 31563
-5-
PCB-ARCH0747357
000000231.000026