&EJTWAU GYPSUM WALLBOARD PRODUCTS SGP 0002174 *E$TWALL GYPSUM WAUBOARD THE ORIGINAL AND ONLY GLASS FIBER REINFORCED GYPSUM WALLBOARD Description?, Bestwall Gypsum Wallboard consists of a glass fiber reinforced core of gypsum rock enclosed between two layers of tough paper. The durable cream face paper is folded around the long edges to reinforce and protect the core. The ends are square cut and smooth finished. A strong gray pape is on the back side. Function and Utility? Fireproof--The solid `core of gypsum wallboard is incombustible. Gypsum will not burn and will not transfer heat in excess of 212 F. until all its water of crystal lization has been driven off in the form of steam. Strength--Readily resists flexural stresses and will not crack or sag when applied to ceilings in the specified manner. Joint Treatment--Wallboard is finished with tapered edges to accommodate the Bestwall Joint Systems or square edges for exposed joints. Fast Decoration--Wallboard, basically a "dry'' material, allows painting or other decoration shortly after application of Joint Treatment. Economy--Large, lightweight panels go up fast. They may be "scored and snapped" or sawed to size. Drywall--Plant fabricated gypsum wallboard eliminates ex treme moisture in wall constructions. Limitations of Use: 1. Gypsum Wallboard shall not be used where it will be exposed to water or excessive moisture. 2. '/" Bestwall Gypsum Wallboard should be applied only to existing surfaces or used in temporary or display work. Sur faces should be sound. When necessary, furring strips should not be spaced over 16" o.c. Vs" Bestwall Gypsum Wallboard should not be applied to nail ing members spaced over 16" o.c. Horizontal application must be used on ceilings. l/z" or Vg" Bestwall Gypsum Wallboard should not be used on nailing members over 24" o.c. When applied to ceilings with the nailing members exceeding 16" o.c. the wallboard must be applied with the paper bound edges at right angles to nailing members. 3. All furring used in application of gypsum wallboard shall have a minimum cross section of 2" x 2" (nominal), with same space limitations as above. BESTWALL FIREPROOF GYPSUM WALLBOARD Regular Gypsum Wallboard--available with tapered or square edges faced with a strong, cream faced paper which will take arty type of decorative treatment. Vi" and Vg" Tapered Edge wallboard are recommenced for single layer application in new construction. Should be used with Bestwall Joint System for smooth, seamless surfaces. Square Edge is recommended for use where exposed |0ints are acceptable. Greater thickness provides increased resist ance to fire exposure and sound transmission. Vs" Gypsum Wallboard is used primarily in repair and remodel ing work. Light weight permits easy handling and appLcat on Also recommended for use in double layer laminated gypsum wallboard construction. Vt" Gypsum Wallboard is a Irghtweight economical g/ps-m wallboard for application directly over existing wailsard :e 1 n(S and for use on curved surfaces and m display work \ Firestop Bestwall--first drywall material to provide up 'o c-e hour fire resistant load bearing walls and ceilings w-ti o"e layer application on both combustible and r-cc~c-s' c'e framing. Firestop Bestwall in two layer appiicat on was ' 'st to provide two-hour fire resistant load bearing walls `-'ate f-om incombustible gypsum rock it combines all the ad.an'ages of regular gypsum wallboard with increased fire protect on--me result of an exclusive Bestwall Gypsum Company ma-.-'act-r. ing process. Incombustible glass fibers and u-e>pa-Jed vermiculite are added to the gypsum core The glass ` ce's remain strong under extreme heat and help keep t-e g,cs-m core intact even after the chemically combined water -as ceen released. The unexpanded vermiculite expands u-aer -eat. thereby balancing the shrinkage of the gypsum ccre a'te' p-e loss of water. The stabilized gypsum core, increas -g -s - a' cn value at extreme high temperatures, provides up to '-"? ~es greater fire resistance than conventional gypsum wj c:a-a 51 Building Code requirements may be met with c -us1:: ~r 45 minute to 3 hour fire-resistant interior wall an 3 -5.-n- struction in buildings of all types fwlp h'ghly " -- -- `e to wood frame; and for varous occupancies "n e Jl' public and commercial character. 2 ext. Crack resistance 'es.sts c'3C"s due to frarmrg movements, viorat ons anj sefmg -jraffeciea by humidity or extremes in temperatures Sound Traosmission Rating results of sound transmission test by Riverbank Laboratories on a standard wood stud par tition faced each side with single layer of V Firestop Bestwall Gypsum Wallboard show a 39 decibel noise reduction value with density of 7 2 pounos per square foot. Strength: Firestop resists crosswise stresses. Firestop Bestwall V board has flexural strength of 225 to 275 lbs. as compared to Federal Specifications minimum requirement of 105 lbs. for -2 inch regular gypsum wallboard. Adaptable to any architectural plan. Bestwall Wood Grained Gypsum Wallboard--regular gypsum wallboard prefinished with reproductions of true-wood pat terns These photographic reproductions are printed on special paper, finished with a durable transparent coating and cemented to the face of regular gypsum wallboard. Combines all the advantages of regular gypsum wallboard with the economy of natural-looking wood grained predecorated panels. Available m five finishes: Driftwood Mahogany, Knotty Pine, Autumn Mahogany. Figured Aspen and Fawn Mahogany. The Aspe- and 'he :-r?e Marcganv co.a-cs are i.cc r: beveled edge k -otty Pme nas square edge Cd'O' ~ej :e : - i are recommended. Bestwall Insulating Gypsum Wallboard--regular g,psum Aail board with aluminum foil laminated to tne back surface In a single application it provides the advantages of regular gvpsum wallboard. an effective vapor barrier and insular -g quant es The foil stops vapor from entering the exterior wall construction, thereby reducing condensation m stud spaces Aluminum fq.i. according to U S Bureau of Standards tests, reflects 30% of radiant heat. Bestwall Gypsum Sheathing--manufactured with prec s oncut tongue and groove edges to provide a structurally st'C-g and dimensionally stable wall. Specially treated core as wen as surface papers combined with V joints eliminate need `or an underlayer of treated building paper (except where requ.'ed by local building codes). The core consists of mcombust ce. processed gypsum rock combined with an emuls.on to pro. de high resistance to water. Officially rated for one full .-our f -eresistance from both sides in combination with g,psum wailboard applied as specified over wood studs and any exte^or finish (wood siding, stucco, brick veneer, etc.) ? 1i r TECHNICAL DATA--BESTWALL GYPSUM WALLBOARD CONSTRUCTION CONSTRUCTION WALL SURFACE FIRE RATING WEIGHT NRC SQ. FT. (AVERAGE) 0ESCI8ELS* Partitions: Wood Studs 16 on center unless noted otherwise. Load bearing and non load bearing unless noted. Surfaced both sides with Partitions. Steel Studs 24 ' on center (Nailable) load bearing Surfaced both sides with V* Bestwall y' Bestwall /?" Bestwall with Mineral Wool in stud space, vj" Firestop Bestwall Firestop Bestwall 2 layers V Bestwall 2 layers *'2" Bestwall 2 layers Firestop Bestwall H" Firestop Bestwall 25 Minutes -- 40 Minutes ! 5 9 1 Hour | ----- 45 Minutes -- 1 Hour 1 72 1 Hour l 32 1 -'2 Hours ----- 2 Hours | 12 9 1 Hour 1 6 5' 35 39 33 35 -- Partitions: Gypsum Studs Non Load Bearing Partitions 2'*" Thick 4" Thick 5" Thick 2 layers H" Firestop Bestwall separated by 1' Gypsum Studs. 2 layers V' Firestop Bestwall on each side of 1' Gypsum Studs 2 layers V" Firestop Bestwall on each side of staggered 1" Gypsum Studs 1 Hour 2 Hours 3 Hours 67 13 4 13 4 30 37 40 ii : e 1 1 1 1ii Ceilings: Wood Joists 16" on center unless noted otherwise. Finished wood floor on rough wood subfloor. Ceiling V' Bestwall W" Bestwall H" Firestop Bestwall lV' Firestop Bestwall V' Firestop Bestwall 2 layers V Bestwall 2 layers `4" Bestwall 1 5 Minutes 25 Minutes 30 Minutes 45 Minutes l Hour 30 Minutes 1 Hour Ceilings: Steel Joists 24" on center unless noted otherwise. 2" Cement floor slab cross furring 16" center. Ceiling V Firestop Bestwall V' Firestop Backer 2 layers V' Firestop Bestwall 1 Hour 1 Hour 1 2 Hours 34 2 34 . 35 3 44 -- -- Steel Columns: Board tied and Finished 2 layers V Bestwall 3 layers '/?" Bestwall 4 layers V' Bestwall 1 Hour 1 2 Hours 2'T^ours fire Hazard Classification Official Underwriters Tests l/j" A v" Firestop.(Listed) 1015 ** \ 3 < 2 > -* * * ; D ; 5 NOTE This table is a summary only based on tests at Underwriters Laboratories. National Bureau of Standards and.cr c* sponsored by the Bestwall Gypsum Company, the Gypsum Association and/or others. The fire rating. weight jno sounj c^jfj on a combination of specific details as covered m official publications of Underwriters Laboratories, the National Bureau ot S'.j University and/or the Bestwall Gypsum Company *J ' *e'vtr ; '? > * " - state inconsistencies Due to Reports covering 15 years and work of different laboratories. 3 i SGP 0002176 BESTWALL ARCHITECTURAL SPECIFICATION--SYSTEM A Material*^ All gypsum wallboard and joint system materials required for installation of Bestwall Hummer System "A" shall be as manufactured by Bestwall Gypsum Co. 1. V backer board. A' wide (or 2' wide) gray face and back paper. 2. V Tapered Edge Bestwall Gypsum Wallboard. 3. V' Tapered Edge Bestwall Gypsum Wallboard with Center Taper parallel to long edges of board. 4. Pa" GW8-54 gypsum wallboaro nails or P's" Bestwall Hummer annular ring steel wire nail. 13 gauge. 15/64" flat head medium diamond point nails. 5. Pa". 4-d. 13 gauge, -i" flat head blue diamond point nail. 6. V, No. 14 Phillips flat head Type A (Tapping) screw, (American Screw Co., of Chicago,-III .) or equal. 7. Bestwall Joint System materials, including Laminating Compound. Cement, Bedding Compound, Topping Com pound, and Tape. Construction! l. Ceiling and Sidewalls (first layer)--For ceilings and sidewalls install first layer of V Bestwall Gypsum Backer board at right angles to framing memDers Edges shall center on studs and joists, using I V' long blued nails (or staples) at 5" to 7" o c on ceilings and 6" to 8" o c. on walls. DO NOT DIMPLE THE BOARD. b. Ceiling (face layer)--Apply Bestwall Laminating Compound on back of face layer board ofto-Backer Board and install the 39" Bestwall Tapered Edge Board with center taper at right angles to joists. Neither end joints nor edge joint in the face layer shall fall over tne joints in the back layer. No edge joint or end joint m face layer shall fall over a joist, but be so installed as to make end joints fall midway between joists. Nail face board at edges and center taper ana before laminating com pound has set. drive V No 14 flat head type "A" screws be tween |Oists spaces in center taper and m tapered edge joint formed by two adjacent boards. Space screws m end joints 12" o.c. C. Sidewalls (face layer)--Apply similar to ceiling face boards: Nail the top Regular '9" Tapered Edge board m place.with IV'. 5 d annular ring nails from ceiling line so as to fall under joint treatment Press board against back layer and nail V' from bottom edge at each stud, install bottom face board similarly to the top board with end joints staggered, if they occur Vertical end joints to fall miaway between studs Before laminating compound has set drive J3 No. 14 Phillips flat head type "A" screws between stud spaces m the tapered edge joint formed by two adjacent boards install screws 12" o.c. at vertical joints. Bestwall Laminating Compound:- Must be mixed to a con sistency so tnat combed ridges will not self level when the board is in a vertical position (use approx. 2-* pounds per one gallon of water). Joint Work:'Apply Bestwall Bedding Compound or Bestwall Joint System Cement to the Taper Edge |Ointsand screw heads. Shear off surplus, leaving no mate'- al on high edges. Allow 12 hours drying before taping, leavng a uniform depth of taper for uniform shrinkage of joint finishes over and under tapes. Apply Bestwall Bedding Compound or Joint System Cement and embed tape leaving a uniform thickness of material under the tape. When bedding compound or Joint System Cement has whitened (surface dry) cover taped |omt with Bestwall Topping Compound. Shear off surplus leaving a uniform coverage over tape with edges well feathered. The bedding compound or joint system cement under the tape and first coverage of tape with topping compound must be thoroughly dry before further treatment. Cover joints a second time with topping compound. Shear off surplus leaving a smooth, well-feathered joint. For best 'esults and a more uniform suction, apply a skim coat of joint system cement or topping compound over the entire surface and shear off tight in lieu of a third application of topping compound to |0mts only DecoratinglDecorating of finished walls is to be done byothers. Where a skim coat has been used to finish the wallboard. a one-ccat paint application may be satisfactory For best results use a prime coat over wallboard before final Jecoration HUMMER SYSTEMS ARCHITECTURAL SPECIFICATION--SYSTEM B Material** All gypsum wallboard and joint System mate'-als required for installation of Bestwall Hummer System B" shall be as manufactured by Bestwall Gypsum Co 1. V Firestop Bestwall Tapered Edge Gypsum Wallboard 2. Gypsum Wallboard Studs. Factory laminated (or on 00) 3. IV and 1-i" No. 14 Phillips flat head wood screws (American Screw Company, Chicago. III.) or equal 4. Nails. Rawl type drives, screws, etc as shown in details 5. Bestwall Joint System materials including Laminating Com pound, Cement, Bedding Compound. Topping Com pound. Tape, and Certex Texture. 6. Metal and/or wood, door frames, runners, trim, caps, etc as per details. Construction! a. General Preparation--Floor runners for par tition work shall be laid out and fastened securely to the floor Where partitions extend to ceiling, the ceiling runner snail oe plumbed up over floor runner and fastened m place Install 2" x 4" nailers between joists at 24" o.c. where partitions run parallel with joists Where one piece door frames are used, mey are to be set m place and braced. b. Erecting First Side of Partition (Panels with Ribs Attached) --Apply Bestwall Laminating Compound with box type comb spreader to the overlapping edge or strip Set panel in position on wood wedges and nail panel to the ceiling and floor run-e-s with IV' Bestwall Hummer Annular ring nails spaced 5" to 7" o c. Reinforce joint between panels by instaHmg 1 - - long Phillips flat head wood screws in the taper, V from edge of board spacing screws 24" o c. C. Erecting Second Side of Partition (Panels with Res Attached)--Apply strips of Bestwall Laminating Compound to back of face board with box type comb spreader where boa'3 comes in contact with laminated ribs m place Place face boa'd on wood wedgesandnailattopand bottom in the same manrer as the first side. The edges m the second sheet shall be offset so that the vertical joints in the finished wall 00 not fail o.er he joint in opposite face board. After two of tne second 'ace panels are in place, reinforce the joints by msfaii-ng 1 ; Phillips flat head wood screws in the joint. 1 ft from ;e , ~g or floor spacing screws 24" o c. d. Door Openings--Fill m rib space around door arj z:~er openings in the wall with a 3' 2" rib covered on both s ees v. m laminating compound. Drive wood clamps m place mmeo a'e , and allow at least 12 hours setting time Afte' clamps a'e 'e moved, the door and iambs shall be set in openings 9^0 ' m med. and the case and ceilmg molding nailed m place ; 1 ; . wood may be used for core space filler 6-j" nbs snail be .sec for doors weighing 100 pounds or more I. Self-Furring Walls--To keep Gypsum board pa-e's f-c~ contact with exterior masonry walls, nail no drip sn-m.s to pa-a.- nbs. Electrical Work: Thm wall conduit can be installed af'er me t -sr side of the partition is in place, and run m tne rio space .e" cally and along the top and bottom of the panels m me space left by holding the rib strips back from panel ends For - g-d ccm duit requiring 1 *4" space 2 strips V board should ce used This will result in a 2 'i" thick wall Runners, door frames a~d trim should be specified accordingly The opposite side of me panel is set m place after the conduit is installed Fire Rated Walls. 1. 2. and 3 Hours (Non-Load Bear-ng) "'-e 2;,i" wall described above with certain additional mec-a" ca fastenings (closer spacing) is listed by Underwriter Lac oratories as 1 Hour Fire Resistive (see Best-wail defa-i cm sheet No. 5583--"Firestop Bestwall Gypsum <VailDoa'd C~e Hour Non-Load Bearing Studless Wall"). Adding one additional layer of V board on each s.ue of --e partition with two runners and making the two sides nje pendent results in a wall 4" thick which is listed by Ur-der writers' Laboratories as 2 Hour Fire Restistive (see oeta-i pun sheet No. 5584--"Firestop Bestwall Gypsum--2 Hour Nor Load Bearing Studless Wall") Separating the two double layer faces by an additional making a ^all 5" thick gives a wall section listed pv Under writers' Laboratories as 3 Hour Fire Resistive (see Best.vni detail plan sheet No. 5585--"Firestop Bestwall G.psum I Hours Non-Load Bearing Studless Wall"). Joint Work: See System "A" specifications. Decorating; See System "A" specifications. 4 SGP 0002177 r *E*TWALL HUMMER SYSTEMS ARCHITECTURAL SPECIFICATION--SYSTEM C Materials:'All gypsum wallboard and laminating compound required for installation of Bestwall Hummer System "C" snail be as manufactured by Bestwall Gypsum Co. 1. 16" wide, rounded edge Bestwall Hummer "C" Panel. 8'. 10'. or 12' long: or 24" wide, beveled edge Bestwall Hummer "C" Panel, 8'. 10'. or 12' long. 2. 34" x lVs" wood runner. (See note on rigid conduit in Electrical Section), 3. Nails, rawl drives, screws, etc., as shown. 4. IV' No. 14 Phillips flat head wood screws (American Screw Company. Chicago, III.) or equal. 5. Bestwall Laminating Compound, non setting mastic, and quick setting mastic. 6. Metal and/or wood, door frames, runners, cap and trim as per details. 7. Metal corner and casting sections as per details. Construction:'!. General Preparation--Floor runners for par tition work snail be laid out and fastened securely to the floor. Where partitions extend to ceiling, the ceiling runner shall be plumbed up over floor runner and fastened in place. Install 2" x 4" nailers between joists at 24" o.c. where partitions run parallel with joists. b. Erection of Panels--After floor and ceiling runners are in stalled including runners at intersecting walls, install 16" "C" panel (or 24") as outlined. Stagger joints in the partition to develop the tongue and groove feature As each panel of the opposite face is set in place, run ribbons of Bestwall Laminat ing Compound, for permanent partition (non-setting mastic for movable partition) down the strips of 3,a" board on the back of the panel. Set them in place Use punch with '/i" pm to countersink for heads of 1V' No. 14 Phillips head wood screws to be driven in the tongue of the previous panel set in place. Install IV No. 14 Phillips head wood screws approximately 24 inches o.c The panels on the opposite side shall be held in place so that the screw can be drawn up tight without stripping. c. Openings--After the panels are erected, the doors and jambs shall be set in the openings and trimmed and the base and ceiling molding nailed in place. Where an opening has been cut m the wall section leaving a hollow space at the open ing. the cut pieces from erected panels, or wood IV. shall be fitted, glued on the sides and mserted around the opening in order that have a solid gypsum rib core at least 3" wide at the edge of every opening to give rigidity and backing for the installation of the casing and trim. d Self-furring Walls--On existing smooth interior walls apply a coat of Bestwall Laminating Compound or non setting mastic on panel ribs, press panel firmly against wall and hold permanently m place with Phillips head wood screws or nails at the top. bottom and middle of panel. For rough interior and exterior walls install "C" panel with "no drip" shims and filler strips as shown on details Flat head nails shall be driven at top, bottom and middle through tongue and shim. Metal Corners and Base--Note. Where local code requires a noncombustible partition, add the following: All floor, ceiling and wall runners at intersecting walls shall be sheet metal of 24 gauge as per detail No. 1 on drawing No. 10. All cut ends of partitions shall be concealed with a metal corner closure or moulding. Metal door frames and base boards shall be used. Electrical Work: Thin wall conduit can be installed after the first side of the partition is in place, and run in the rib space vertically and along the top and bottom of the panels in the space left by holding the rib strips back from panel ends. For rigid conduit requiring wider space a 2;i" x V strip may be used at each rib between panels to widen space to IV Run ners. door frames, and trim should be specified accordingly. If necessary, the back panel may be gouged out for connectors at boxes Do not cut paper between the two full 'V sheets of "C" panel. The opposite side of the panel is set in place after the conduit is installed. Decorating: As there is no Joint System m the wall area, a one coat paint |0b may give a satisfactory job if a flat or semi gloss finish is used Wood trim should have all nail holes puttied and primed before final coat of paint. ARCHITECTURAL SPECIFICATION--SYSTEM D Material*:' All gypsum wallboard and joint system materials required for installation of Bestwall Hummer System "D" shall be as manufactured by Bestwall Gypsum Co. 1. 3V' by 8" and Ya" by 4" strips of Bestwall Gypsum Wallboard. 2. V Tapered Edge Bestwall Gypsum Wallboard 3. V Tapered Edge Bestwall Gypsum Wallboard with Center Taper parallel to long edges of board. 4. IV GWB-54 gypsum wallboard nails or IV Bestwall Hummer annular ring steel wire nail. 13 gauge. 15/64" flat head medium diamond point nails. 5. lVx", 4-d, 13 gauge. V flat head blue diamond point nail. 8. V". No. 14 Phillips flat head Type "A" (Tapping) screw, (American Screw Company of Chicago, III.) or equal. 7. Bestwall Joint System materials including Laminating Compound, Cement, Bedding Compound, Topping Com pound and Tape. Construction: 1. Strips-- V gypsum board strips. 8" wide, shall be nailed on both the wall and ceiling framing. 4" strips may be used at ceiling angles and at the floor line on all walls. V gypsum board strips 8" wide by 8' long shall be spaced so that the long edges and center of face board center on those strips. Maximum center to center of the 8" strips shall be 24" o c. V gypsum board strips 8" wide of sufficient length to span two joists or studs shall be installed between long strips and directly under end joints of face board in ceiling and on walls. Nail strips with two blued nails one inch from edge of strip at each joist and stud. DO NOT DIMPLE THE BOARD. b. Ceiling (Face Layer) Before face board is installed, cut off all damaged edges and apply strips of Bestwall Laminating Compound to backside of face board or to strips on ceiling. Install V2" Bestwall Tapered Edge Board with a Center Taper at right angles to ceiling |0ists over stripping. No edge joint or end joint in the face layer shall fall over a stud or joist, but shall be so installed as to make end joints fall midway between studs or joists. After the board is in place, nailed in edge and center taper only, and before the laminating compound has set. drive V No. 14 Phillips flat head Type "A" screws in tKe t3ce'ed edge joint formed by two adjacent boards and m tne center taper. No screws are required .n the center taper if .0 sts a'e 16" or less 0 c. Screws also shall be installed at 12" 0 c. at end lomts falling between center of joists. c. Sidewalls (Face Layer) Regular V' Tapered Edge Board shall be applied horizontally over the walls Bestwall Laminating Compound shall be applied m strips to the back cf he face board or to the strips on wall. The top face board snail be nailed in place with 5-d. IV annular ring nails V from ceiling line so as to fall under joint treatment or proposed trim Press board against strips and nail V from edge at each framing member. The bottom board shad be installed similarly to tne top face board with end joints staggered, if they occur Vertical end joints between face* boards shall fall midway between studs. After the board is in place and before the Laminating Compound has set. drive V No. 14 Phillips fiat head Type "A" screws between stud spaces in the tapered edge joint formed by two adjacent boards Screws shall also be installed 12" o.c. at vertical end joints. Bestwall Laminating Compound: See System "A" spec he a tio ns. Joint Work: See System "A" specifications. Decorating; See System "A" specifications. For more detailed specifications, write manufacturer's general office Bestwall Gypsum Company 120 East Lancaster Avenue Ardmore, Pennsylvania 5 SGP 0002178 BEFTWALL FIRESTOP BESTWALL ORIGINAL ONE HOUR FIRE RATED GYPSUM WALLBOARD The original one-hour Fire rated gypsum wallboard-- Firestop Bestwall is recommended where extra fire resistance is re quired in residential, commercial and public buildings thickness provides one hour fire resistance in single layer application on both walls and ceilings over wood or steel, yj" thickness provides 45 minutes fire rating in single layer appli cation when applied over wood framing, for both walls and ceilings. The extra fire protection offered by Firestop Bestwall -s right into the core through the use of specific amounts of n combustible glass fibers and unexpanded vermcuhte Vs" Firestop Bestwall qualifies for code acceptance in ail r-e constructions in the table below Firestop Bestwall is listed by Underwriters' and carries the UL Label for 1. 2 ana 3 hour Fire Resistance in various Designs and for Fire Hazard Classifica tion of 10-15 FRAMING Metal Studs 24" (Max.) O.C. 2" x 4" Wood Studs 16" o.C. PARTITIONS --LOAD BEARING OR NON-LOAD BEARING CONSTRUCTION RATING AUTHORITY 1 layer. V*" Firestop Bestwall both sides. 2 layers, V Firestop Bestwall both sides 1 layer. sy* Firestop Bestwall both sides 1 Layer. V Firestop Bestwall both sides 1 hour 2 Hour 1 Hour 45 Min. Test by independent, nation ally known laboratory. Name on request. Test by independent, nationally-known laboratory. Name on request. Underwriters Laboratories Retardent 2889 8/5/47 Underwriters' Laboratories Retardent 2717 7/29/46 UL Design No. iCBO Research Recommenaaton 1 1 1155. - 1000 5 1145. 1- NONE NONE PARTITIONS --NON-LOAD BEARING 1 layer. ^ Firestop Underwriters* Laboratories Bestwall both sides over 1 Hour Retardant 2717 -19 21- 10 1: -14 l " Gypsum Strios 6/3/57 2 layers, * Firestop Bestwall both sides over 1 * Gypsum Strips 2 Hour and 3 Hour Underwriters' Laboratories Retardant 2717-20 228/26/57 7 5 12 63 FLOOR AND CEILING 12' Bar Joists 24" O.C. Covered with 2" concrete floor slab 1 layer, *y Firestop Bestwall as ceding surface through metal furring 1 Hour Underwriters' Laboratories Retardent 2717-16-12/1/52 2 115 5 1 2" Bar Joists 24" O.C. Covered with 2" concrete floor slab 2 layers, *y` Firestop Bestwall as ceiling surface through metal furring 1 Vt Hours Underwriters' Laboratories Retardant 2717 23-12/1 /59 3 2" x 10" Wood Joists Covered with wood building paper, wood finish flooring 1 layer. Firestop Bestwall as ceiling surface 1 layer, ;y Firestop Bestwall as ceding surface 1 Hour 45 Mm. Underwriters' Laboratories Retardant 2717 7/12/51 Underwriters' Laboratories Retardant 271 7-6/27 /50 1 1 1 145 - PLUS a Flame Spread Rating of 10 15 for both Fire Hazard Classification and ' Firestop based on Official Underwriters* Tunnel Furnace Tests and i-sted by f'e"' TOU ARE PROTECTED ACAiNST SUISTiTUTiOWof inferior material by Underwriters' Laboratories LabenService, as evidenced by the Underwriters Labo ratones Manifest which appears on the twin mounting tape binding each bundle of 2 pieces And especially important to 3^^ 'e:*q 1 ~ building inspectors, the front of each sheet s marked *<tn - * ** stop Bestwall* so that it s easy to iJentify when m place Details of construction and information about sound transmission rating. tieiurai strength, backer for acoustical file will be sent upon you' FIRE HAZARD ClASSlFlCA rON Flame Spread Fuel Contributed Smoke Developed l ) 16 5 16 0 15 MANIFEST FOR V FIRESTOP BESTWALL in 1 m <<a i .\r ns 6 2 SGP 0002179 mmmmm*E*TWALL GYPSUM WALLBOARD SINGLE LAYER APPLICATION USING BESTWALL OVER WOOD FRAMING ON WALLS AND CEILINGS Bestwall Regular Gypsum Wallboard^ Where Bestwall is applied directly to wood framing members, ceilings are put up first, then walls. Board layout should be planned to minimize |OintS. Jomts must always occur over a stud. Boards should be accu rately cut to fit and |Oints loosely butted In wall construction, horizontal application is recommended where joints are to be concealed. Vertical application is recommended where |OintS are to be left exposed or finished with metal or wood trim. In ceiling application, the boards should always be applied at right angles to the nailing member. Nails should be spaced not to exceed 7" on ceilings and not to exceed 8" on walls. Function and Utility: 1. Reduces necessary joint treatment footage. 2. Avoids need for headers. 3. Each board braces more framing members. 4. The fewer |oints can be treated at convenient height for finishing. Thickness: Vt", Ve". Vt". %" Width: 4' Edges: Tapered or Square Length: 6' to 16' Firestop Bestwalb Vt" and Firestop Bestwall combine all i the advantages of regular gypsum wallboard with increased I fire resistance--the result of a specially formulated core con- I taming incombustible glass fibers and unexpanded vermiculite. ! A single layer of ' 2" Firestop on both sides of a load bearing ! wood stud wall or as the ceiling finish of a standard wood joist j and floor construction provides a 45 minute fire rating. I One layer of V Firestop over load bearing wood or metal studs, or used in a non-load bearing Bestwall Hummer System "B" construction provides one hour fire resistance One hour fire rating is also provided by one layer of *V Firestop as the ceiling f.msh beneath either a wood joist and floor construction or steel bar joist and cement floor construction. Thickness. ' 2". :s" Width. 4' Edges: Tapered or Square 1 Length. 6' to 16' Bestwall Wood Grained Gypsum Wallboard? In single layer application. Bestwall wallboards with square or beveled edges, such as Wood Grained Wallboard. present a more attractive appearance when applied vertically. Joints may be covered with wood trim or left exposed. Decoration Bestwall Wood Grained Gypsum Wallboard may be given a glossy finish by painting with a clear shellac or by varnishing and then waxing. Thickness: ]'a" ( 2" on order) Width j4' Edges Beveled (Figured Aspen, Driftwood Mahogany, Autumn Mahogany and Fawn Mahogany) Square (Knotty Pme) Length 8'. 9'. 10' Bestwall Insulating Gypsum Wallboard: Bestwall Insulating Gypsum Wallboard is made by laminating bright aluminum foil to the back surface of regular gypsum wallboard. Vapor Barr-er--It serves as a vapor barrier for exterior walls and ceilings when applied with foil surface next to the studs in single layer application Or as the base layer in a double layer system. Insulation--To achieve insulation value, 't must be installed with the foil side against the studs and facing a minimum air space of V Thickness: Width 4' Edges Tapered, Square Length 6' to 16' 7 i e ) 7 i f SGP 0002180 BESTWALL JOINT SYSTEMS ARCHITECTURAL SPECIFICATIONS Scop*:'AII walls, partitions and ceilings are included in these specifications. Furnish all labor and material necessary to reinforce and conceal |omts between gypsum wallboards according to specifications. Materialsijl. One-Material Treatment--Bestwall Joint System Cement (used for both bedding and topping and for spotting nail heads) Specially suited for remodeling and home im provement work, 2. Two-Material Treatment--Bestwall Bedding Compound, Bestwall Topping Compound. Specially designed for use on large projects. Reinforcing Tape: Bestwall Tape Joint Work: Apply Bestwall Bedding Compound or Bestwall Joint System Cement to the Taper Edge joints, end joints and nailheads. Shear off surplus, leaving no material on high edges. Allow 12 hours drying before taping, leaving a uni form depth of taper for uniform shrinkage of joint finishes over and under tapes. Apply Bestwall Bedding Compound or Joint System Cement and embed tape leaving a uniform thickness of material under the tape. When bedding compound or Joint System Cement has whitened (surface dry) cover taped joint with Bestwall Topping Compound Shear off surplus leaving a uniform coverage over tape with edges well feathered. The bedding compound or |Oint system cement under the tape and first coverage of tape with topping compound must be thoroughly dry before further treatment. Cover joints a second time with topping compound Shear off surplus leaving a smooth, well-feathered |omt. For best results and a more uniform suction, apply a skim coat of joint system cement or topping compound over the entire surface and shear off tight m lieu of a third application of topping compound to joints only. Decorating: Decorating of finished walls is to be done by others. Where a skim coat has been used to finish the wallboard. a one coat paint application may be satisfacto'y For best results use a prime coat over wallboard before fmai decoration. Cement is "buttered" into joint. Tap* is "bedded" in cement. Second and third coats of cement are applied over entire reinforced joint. Cross section oi s^e i Bestwall ,omt PRODUCE BESTWALL GYPSUM COMPANY Ardmore, Pennsylvania Plants and offices throughout the United States SGP 0002181