Document 3JDpJExrDROpjE0jn8nVRdOGE
DIVISION Of SAFETY AMD HTaiENg INDUSTRIAL COMMISSION Of OHIO
'^
April 11, I960
, ' V-
, ; s.
'` ;
Mr. James H.Fluker, Superintendent
`,
Division of Saftty up Hygiene
-r
Coluwbu* 15, Ohio.
Rei Kimble Glass Company/
Coluebus, Ohio
, *w
1* On March 21, 1960 a visit mi made to the above-named company to check
du*t conditions.
.
1
2. Contact: aa mad^with Mr, Raymond J. Leddy, Safety Director.
r
a.
',
v.
3* Tha coapany **r.vracturee television picture tuba shells.*,
% .'
*
a'.,..
. .
4. A cutting abrasive, containing 97 per cant fra*'silica, la Mixed with water
aiv? sprayed oh wolds which are enclose^ in a aachlne. The wolds are then
rewoved, cleaned,rand dried.wltlv forced air.
` * ' ' J*'
`
5.
Dust
couinta
we?.e1 t#Ven
and the - '.
Results
art
at
follows i .
*
ISZ
, ,,, -V UEgOST
*
A. In the breathing'.so/* of tbeVapox blaster operator.;
B. Approximately.30' from vapor blatter Machine to obtain
general dust concentration^
...
C. Breathing aonepf wold grinder operator.
3.1 . 1.7
4,36
MPPCF - willlon particles per euble foot of air.
6. According to Bulletin-N& 203 the maximum allowable concentration for duet
containing fro*'3 to SOspSrtt cent free gllloale 20.0 Million partlclea per
cubic foot of air. - The meximoa allowable concentration for. dust oontainlng
over 50 per cent free elltea-it.5.0 Million particles per cubic foot of air.
The Division of'Safety*and Hygiene-reeoemende that the duet concentration,
if at all possible,' be kept below 2.0 Million particles per cubic foot of
air.
- i- . / f
J V _ . . <
.
.
7. A dust saople was taken to determine the per cent of free silica in the
breathing sons of the vapor blaster operator.- A sufficient quantity of
dust wet not obtained for a reliable Xray dlffraotion analysis.
8. It Is recommended theti
A. The coapany attaopt -to replace the silica abrasive with a harmless abrasive,
B. eater under pressure bmapplied to the molds so as to wash away aost of the silica abrasive*before air is used to dry tbas.
9. It waa a pleasure to visit this coapany and their cooperation was greatly appreciated.
Respectfully submitted,
\`'f
Richard Heepy
""
- Industrial Hygienist
RH/ap
DeNitt Huffman
-/
Industrial Hygiene EnglwVe#
s