LUBRICATION
A TECHNICAL PUBLICATION DEVOTED TO THE SELECTION AND USE OF LUBRICANTS
Published by
Texaco Inc., 135 East 42nd Street, New York, N. Y. 10017
J. H. Rambin, Jr., Chairman of the Board of Directors; J. W. Foley, Vice Chairman of the Board of Directors; M. J. Epley, Jr., President; A. W. Baucum, Harvey Cash, J. W. Green, J. H. Pipkin, Executive Vice Presidents; W. E. Avery, W. G. Copeland, S. T. Crossland, R. J. Derby, C. H. Dodson, Henry Flynn, M. F. Granville, Ben Halsell, O. B. Hocker, H. C. Hose, L. C. Kemp, Jr., Kerryn King, J. V. C. Malcolmson, J. I. Mingay, W. H. Ryer, H. O. Woodruff, Vice Presidents; A. B. Steed, General Counsel; W. J. Clayton, Secretary; W. R. Love, Comptroller,
E. C. Mitchell, Treasurer.
Volume 52, No. 1
COPYRIGHTS: The contents of LUBRICATION are copyrighted and cannot be reprinted legally by other publications without soritten prior approval from Texaco and then only if the article is quoted exactly and accompanied by the credit line "Courtesy of Texaco's magazine LUBRICATION", Copyright 1966 by Texaco Inc. Copyright under International Copyright Convention. All rights Reserved under PanAmerican Copyright Convention. CHANGE OP ADDRESS: In reporting change of address please gtve both old and new address: Write to--C. R. Frohlin, Texaco Inc. 135 E. 42nd St., New York, N. Y. 10017: or H. E. Whiting, Texaco Canada Ltd., 1425 Mountain St., Montreal 25, Quebec, Canada.
ANALYTICAL ADVANCES
irtually every branch of analytical chem utilizes basic principles known to scientists for over
V istry discussed in previous issues of this 150 years, but has been continually refined, result publication1,2,3 is influenced by new instru ing in improved accuracy and resolution, extended ments, devices and techniques. Technical advanwceasvelength coverage, and many automated features
in this area have resulted in more rapid, accurate as well. While various forms of emission and infra
and complete answers to the ever present questions: red spectroscopy have been used in analytical labora
"What is it?" and "How much?" This accelerated tories for years, other relatively new, more recently
progress was inevitable, resulting from industrial developed techniques have also become valuable
demands for faster, more efficient processing, for analytical tools. Some of these include (1) nuclear
better quality control, and increased emphasis on magnetic resonance, (2) gas chromatography, the
pure and applied research. It is indeed a major chal first account of which was published towards the
lenge to those responsible for industrial analysis end of 1952,'1 (3) activation analysis, a by-product
and testing to keep abreast of these advances and to of the nuclear age and (4) atomic absorption spec
make the proper selection of instrumentation, tech troscopy, which was first suggested as an analytical
niques and methods in order to enhance the relia tool in 1955.5
bility of their work and results. This article will
In common with all instrumental methods of
describe some of these advances and illustrate their analysis, the methods and techniques discussed in
application to the analysis of petroleum and related this article depend upon measuring a key physical
products.
property or characteristic of the sample, which, in
Instrumental methods of analysis have been prac turn, can be related to its chemical composition.
ticed in the petroleum and other industries for many Since analytical instrumentation does depend upon
years. However, with the development of automated this principle, it logically follows that each instru
and direct readout equipment, many basic instru ment must be standardized or calibrated with mate
ments have evolved into faster, more sensitive, more rial of known composition before it can be used on
specialized and more complex devices. Two major a routine basis. Not infrequently, the availability of
examples of this continued development are emis reliable standards is a limiting factor in instrumental
sion and infrared spectroscopy. Direct reading emis analysis.
sion spectrometers, which are adaptations of the conventional optical spectrograph are custom built for a specific apphcation and record results directly
EMISSION AND INFRARED SPECTROSCOPY
on dials or strip chart recorders. Infrared analysis
Emission and infrared spectroscopy are undoubt
1 Id this issue superior figures refer to items in its Bibliography of edly two of the most important areas of analytical
corresponding number.
instrumentation. Separately or in combination, they
) [1}
DSW 202131
STLCOPCB4060198
LUBRICATION
can handle an almost unlimited variety of applica tions. A few examples of where these techniques are used in the petroleum industry are: (1) analysis of samples for identification; (2) analysis of inter mediates and finished products for product quality control; (3) product development studies; (4) fol lowing the effect of service on products; and (5) investigation of complaints, particularly where product quality or performance may be questioned. This list is by no means inclusive of all of the pos sible applications of these two techniques.
A comprehensive discussion of these techniques and applications is obviously beyond the scope of this publication. However, the almost universal use of even the more sophisticated instruments illus trates the acceptance of modern instrumentation by modern industry. For a more detailed discussion, the reader is referred to texts on these subjects6,7 and the more recent applications which are covered in the Annual Reviews of Analytical Chemistry.
and time-consuming steps which must be done manually with optical spectrographs. While the typical direct-reading spectrometer is programmed to determine up to sixteen elements simultaneously, larger and more sophisticated models which will determine up to sixty elements are available. The main advantage of direct-reading spectrometers is their speed; once they are properly calibrated, re sults are available only minutes after the sample has been received in the spectrographic laboratory. Their value in high volume, routine work is well recognized.
Emission Spectroscopy
Recent interest in emission spectroscopy has been directed primarily toward automated direct-reading spectrometers such as the one shown in Figure 1. These instruments depend upon sensitive photo multiplier tubes and associated electronic equip ment available today for the detection and repro ducible measurement of very faint spectral energy. The direct-reading spectrometer has proven a stable, rugged instrument ideal for many applications. It is particularly valuable where many analyses of a repetitive nature are required, such as in the pri mary metals industries.
Figure 1 --A direct-reading emission spectrometer.
The essential components of a typical directreading spectrometer are shown schematically in Figure 2. The reader will recognize from this draw ing that the direct-reading spectrometer is actually an adaptation of the optical grating spectrograph. The essential difference is that the camera portion of the conventional spectrograph has been replaced with a carefully arranged system of exit slits, photo multiplier tubes, condensers, amplifiers and record ers which automatically perform the various tedious
Figure 2 -- A schematic diagram of a direct reading emission spectrometer.
One area of particular interest to both the users and suppliers of lubricants is the oil analysis method of monitoring impurities and wear metals as an im portant part of preventive maintenance programs.'^ Many operators of diesel engines, such as railroads, truckers, and power plants, as well as oil company laboratories, use emission spectroscopy to check the condition of used crankcase oils. Although many of the elements of interest are present in the parts per million range, direct reading spectrometers are useful in used oil analysis for speed and conven ience; many of these instruments can handle samples of this nature without preliminary prepara tion or treatment.
The speed of these instruments is particularly important in initiating corrective action when re quired. For example, the Bureau of Naval Weapons8 has investigated this method for monitoring aircraft engines and other aircraft mechanisms. It was con cluded from these studies that: (1) if difficulty de velops in the oil-lubricated section of a jet engine and remains undetected, the chances are that single engine aircraft will fail in flight; and (2) at least half the total cost of one of these aircraft is saved each time a discrepant engine is found. Since each of these aircraft costs several millions of dollars, the value of the spectrograph in protecting this in vestment is readily evident. Although perhaps less dramatic, the same principle applies to many other pieces of mechanical equipment.
Infrared Spectroscopy
Versatility is the one word which best describes
[2] --*
DSW 202132
STLCOPCB4060199
LUBRICATION
l infrared instrumentation. A wide range of instru ments is commercially available today, from rela tively simple, easy to operate spectrophotometers costing less than $5,000 to complex high resolution spectrophotometers available at prices in excess of $20,000. Figure 3 shows an example of a rela tively inexpensive table model, while Figure 4 illus trates a grating instrument covering the wavelength region from 2.5 to 50 microns. The selection of a particular instrument depends to a considerable extent upon individual requirements and prefer ences.
Figure 4 -- A grating infrared spectrophotometer having a range of 2.5 to 50 microns.
Figure 3 -- A relatively inexpensive table model infrared spectrophotometer.
Accessories which enable investigators to handle almost every conceivable sample form--solids, liquids, gases, and even microscopic quantities are available for most instruments. These techniques have permitted the spectroscopist in every field of analysis to take an increasingly closer look at even the most detailed and complex molecular structure.
As an example of the new accessories, the reflect ance technique provides a simple, convenient and versatile means of examining samples which previ ously were difficult or impossible to adapt to stand ard infrared procedures. Infrared energy, as shown schematically in Figure 5, strikes the crystal-sample interface at an angle greater than the critical angle. This energy is reflected from the interface and meas ured. Little loss of the original energy occurs except at wavelengths where the refractive index of the sample increases or decreases. Since these wave lengths correspond closely to the absorption bands of conventional infrared spectra, absorption data can be used to yield similar information about the composition of the sample. Surface films, polymers, viscous liquids and many other difficult samples have been analyzed using this approach.
Another particularly significant development is the use of infrared for routine examination of used gas engine oils. The combustion process in natural gas engines frequently promotes the fixation of nitrogen by combining nitrogen and oxygen from
the combustion air. The reaction of these fixed ni trogen compounds with lubricating oil forms acidic materials and other undesirable products which ultimately become oil insoluble. These materials are major factors in forming engine deposits, there by limiting useful oil life. Measurement of these materials as they accumulate in used oils provides information which may be used to establish opti mum engine operating conditions and oil drain periods. While oil oxidation and thickening may be factors in any type, size or model of gas engine, ni trogen fixation tends to be most prevalent in natu rally aspirated four-cycle gas engines. Fortunately, however, infrared analysis can be easily extended to determine oxidation and water contamination as well as nitrogen fixation in used gas engine oils, as described in the following discussion.
A technique known as differential infrared analy sis (DIR) is particularly useful when applied to used gas engine oils. In this technique, a sample of unused oil is placed in the reference cell of a double beam infrared spectrophotometer and the used oil in a matched sample cell. Thus, the absorb ance due to the oil itself is compensated, and the net absorbance is due to differences in chemical composition between the used and unused oils which have occurred as a result of service. A typical differential infrared spectrum of a used gas engine oil is shown in Figure 6.
The possible presence of water is indicated by
Figure 5 -- A schematic diagram of the reflectance technique in infrared spectroscopy.
[31
DSW 202133
STLCOPCB4060200
LUBRICATION
FREQUENCY (CM"1)2 3 4 5
the absorbance in the 2.9 micron region. Carbonyl compounds (oxidation products) are shown by the downward "peak" in the 5.8-5.9 micron region. Organic nitrates and nitro compounds represent the types of nitrogen compounds which are formed most frequently in oils by nitrogen fixation. The peaks at 6.2, 7.9 and 11.8 microns in Figure 6 are due to the presence of organic nitrates, while the peakat6.5 microns is attributed to nitrocompounds.
The differential infrared technique has been used to evaluate gas engine oils in many field tests, in cluding all types of gas engines. By correlating dif ferential infrared data with engine inspections and conventional chemical tests, safe condemning limits for oil and filter changes have been established. While these may vary to some extent depending upon the type of oil in service, experience has shown that DIR data are as reliable as conventional chemi cal analyses. In addition to its advantages of speed and convenience, infrared analysis is the only re liable means of detecting early stages of abnormal nitrogen fixation in a particular engine.
Knowing the characteristic differential infrared patterns of used oils from engines of various de signs, as well as operating characteristics of indi vidual engines, this technique frequently provides valuable information concerning engine operating conditions. For instance, it is often possible to de tect one or more of the following conditions by examination of used oils:
6. Faulty operation of crankcase ventilating sys tem, and
7. Engine overload.
Obviously, corrective action on any of these items
could result in substantial savings, either from ex
tended oil life or a reduction in unscheduled engine
maintenance.
f
NEW METHODS AND TECHNIQUES
Although not used to any extent in industrial analytical laboratories only ten years ago, the re maining four techniques to be considered have since been used to solve many thousands of analytical problems. These new approaches selected for dis cussion include the relatively inexpensive and less complex gas chromatography and atomic absorption techniques as well as the more elaborate and costly nuclear magnetic resonance and activation analysis methods. These four techniques are merely ex amples of areas of expanding interest to the analyst, as many other novel approaches are now being ap plied in analytical laboratories throughout the world.
As with emission and infrared analysis, a com plete discussion of each of these new techniques is obviously beyond the scope of this article. Rather, a brief outline of the basic principles and main areas of application will be presented, and for additional information on specific features, the reader is re ferred to corresponding items in the Bibliography.
1.FIot spots, either on pistons or cylinder walls, 2. High crankcase bulk oil temperatures, possibly
due to a faulty cooling system, 3. Improper air/fuel ratio, 4. Improper spark timing, 5. High rates of combustion blow-by,
Nuclear Magnetic Resonance
Nuclear Magnetic Resonance (NMR) was first discovered in 19469,10 and its practical applications recognized by 1952, when Felix Bloch and E. M. Purcell, the co-discoverers, received the Nobel Prize Award in Physics. NMR is primarily con
[4 ] , DSW 202134
STLCOPCB4060201
LUBRICATION
cerned with energy level transitions of atomic nuclei in a magnetic field. These transitions are ex pressed by different magnetic quantum numbers and are analogous to electronic and vibrational-ro tational energy changes in other forms of spectros copy. NMR spectroscopy involves the region of the electromagnetic spectrum just beyond the far infra red, sometimes referred to as the microwave region. The nucleus is not studied per se, but is used as a minute probe to reveal the molecular structure which surrounds it.
An NMR spectrometer consists basically of a magnet, radio-frequency (rf) transmitter or oscilla tor, and a suitable rf receiver, as illustrated sche matically in Figure 7. By the simultaneous applica tion of a strong direct-current magnetic field and a radio frequency field to a sample, at values related to the nuclear magnetic moments of angular mo mentum, a detectable "resonance" effect can be induced.
ganic compounds and shows typical resonance
bands. Commercial instruments for wide-line and
high resolution as well as dual purpose instruments
OSCILLATOR
SAMPLE
RECEIVER
are available.
1/ft* rr/\ P MAGNET 1
The most useful application of NMR is the de termination of the molecular structure of organic compounds. NMR is used primarily in conjunction
Figure 7 -- A nuclear magnetic resonance (NMR)) spectro with other analytical methods such as gas chroma
meter shown schematically.
tography, mass spectrometry and infrared analysis.
\
Because nuclear magnetic resonance produces relatively weak effects, sensitive instruments such as the one shown in Figure 8 are needed for its detection. The development of these instruments to their present useful state has depended to a con siderable degree upon understanding and corre lation of problems in many related fields of science
Its principal advantages include speed and the cer tainty with which it can be used to identify certain functional groups under a wide variety of conditions without requiring precise calibration with the exact compounds being studied. It has proved to be espe cially valuable in petroleum research labora tories.13,14
and technology. For example, magnets for use in NMR instruments are limited by uniformity of
Activation Analysis
field requirements. However, a cryogenic magnet
Activation analysis is one of several analytical
for a pulsed NMR spectrometer was recently de techniques which yield specific elemental analyses.
livered to Rice University; the magnet, rated at 25 Accordingly, it is not concerned as to how the
kilogauss, has a field uniformity better than 1 in elements are combined chemically.
106 and its weight is only 200 pounds, compared to In contrast to other instrumental methods, such
the 6 tons for a comparable conventional unit.11 as emission and x-ray spectroscopy and flame pho
Also, because of weak signals in NMR, signal-to- tometry, in which detection of an element depends
noise ratio in signal amplification is often a prob upon excitation of the electrons in the atom, the
lem. A practical means of improving the sensitivity activation method seeks out the core of the atom, --
is to use a multichannel pulse-height analyzer--es the nucleus. This technique involves the creation
sentially a small computer which can store and and detection of radioactive elements. The process
remember several hundred traces.12
of activation analysis actually begins by irradiating
Two basic types of nuclear magnetic resonance the sample by bombarding it with one of many
spectroscopy are wide-line and high resolution species which will interact with the nucleus to form
NMR. Wide-line NMR is concerned with the broad a radioactive element artificially. Specifically, such
resonance character of a particular nucleus in many species include charged particles, high energy gam
of its interactions with its surroundings. High reso ma rays, X-rays, and neutrons. As a result of the
lution NMR detects the slight shifts and fine struc bombardment, the stable element nuclei are either
tural details that represent the differing intra-mo- converted into radioisotopes of the same element
lecular environments for a given nucleus. Figure 9 or, as frequently happens, transmuted into isotopes
presents high resolution NMR spectra of three or of different elements. It is then possible to detect V
[5}
DSW 202135
STLCOPCB4060202
LUBRICATION
Shielding Number
1
C 138.6 0 715.
Figure 9 -- High resolution NMR spectra of three organic compounds. Note typical resonance band assignments.
[6]
J
DSW 202136
STLCOPCB4060203
LUBRICATION
f these radionuclides (radioisotopes) by the radia-
' tions they emit, either at the instant of their forma tion or during their subsequent characteristic radio active decay. The radiation most easily detected in either case is the gamma ray--the "prompt gamma" at the instant of formation and the "delayed gam ma" during radioactive decay. Although it is not the only radioactive emission in activation analysis, the gamma ray is most frequently "counted" by detec tors such as the sodium iodide scintillator. The spec trum of gamma ray energies identifies the element, while the "count" serves as an index of concentra tion of the irradiated element. In practice, the speci fic activity of an unknown sample is compared to that of a standard sample irradiated under the same conditions.
For a detailed explanation of atomic structure, radioactive decay, and transmutation processes, the reader may wish to consult additional references on these subjects.15,16
Recalling the various forms of bombarding spe cies mentioned previously, it is easy to visualize that many different radioactive products could result be cause of differing conditions of radiation. It would also follow that the analytical approaches would necessarily be quite varied. Such is the case; one 1963 reviewer17 places the number of references to activation analysis at more than two thousand. The 1964 review by G. W. Leddicotte18 alone refers to r more than 235 papers on activation analysis. As a consequence of the accumulated experience in this field, three textbooks in English19,20,21 and one in French22 have been published. The first of these references describes activation analysis methods for 85 of the 104 presently known elements.
Three types of activation are: (1) Charged Particle Activation, which requires high-energy accelerators for the bombardment of the sample with protons, electrons, deuterons, he lium ions or even heavier ions. This type of activa tion is limited to the specimen surface because nu clear repulsion forces prevent the particles from penetrating deeply into the sample. One major dis advantage is that high beam currents may cause excess heating which distorts the sample. Never theless, charged particle methods are frequently used to characterize the elements at surfaces, par ticularly of metals. As a typical example, helium-3 bombardments are used in the analysis of light ele ments such as beryllium, carbon, oxygen, nitrogen and fluorine. (2) Photoactivation, using accelerator-produced high energy gamma rays and X-rays (Bremsstrahlung), is also useful in certain activations. The en ergy requirements for gamma photoactivation of the lighter elements are usually high (around 15 Mev), therefore the utilization of this approach is limited to the most powerful accelerators. Some of the heavier elements respond to less energetic (1
Mev) Bremsstrahlung produced by electron ac celerators, but the sensitivities are less favorable than those of neutron activation.23
(3) Neutron Activation, which enjoys the wid est use in the field of activation analysis. The neu tron has the essential mass of the hydrogen atom and bears no charge; it can, therefore, easily pene trate matter and be "captured" by nuclei to form radioactive elements. A recent comprehensive re view24 describes how neutrons interact with most of the stable nuclei to produce one or more radio nuclides. Certain elements, such as carbon and hy drogen, do not respond in this manner and hence are not readily adaptable to this method of analysis.
Figure 10 -- A schematic diagram of a neutron generator typical of those used in industrial facilities.
Since neutron activation is the most popular type of activation analysis, the balance of this dis cussion will be devoted to it. Figure 10 shows a schematic diagram of a neutron generator typical of those used in industrial facilities.
Analysis by neutron activation is not necessarily the universal solution to all problems of elemental analysis. In fact, in many routine situations it can not compete with other instrumental methods. However, in certain specialized situations it is the only method which is applicable in sensitivity or in speed.
It is interesting to review the reasons for the in creasing use of neutron activation analysis. The basic reason is the growth in all of the technologies involved with nuclear science. Without the dra matic progress in physics, chemistry, electronics and related fields since the dawn of the atomic era, the potentials of neutron activation would have re mained unknown. Now, however, the following characteristics may be listed:
1. Neutron activation is sensitive for trace ele ment analysis; many determinations are in the parts-per-billion or parts-per-million range.
2. Neutron activation analysis lends itself to rap id, automated instrumental techniques.
3. The technique is non-destructive in that a rela tively small number of radionuclei are actually created.
V [7]
DSW 202137
STLCOPCB4060204
LUBRICATION
TABLE I
SOURCES OF NEUTRONS FOR ACTIVATION ANALYSIS
Neutron Source
Mechanism of Neutron production
Neutron flux (n/ems/sec)
Number of Elements Activated_______________
Remarks
Approximate Cost
Nuclear Reactors
Fission of uranium or plutonium.
10" 10" 10" (pulsed)
72 elements as 150 radionuclides
65 elements detected in ppm or ppb $250,000
range. Automatic analysis of several
hundred samples daily.
.
Van De Graaff Accelerators
Deuteron bombardment of beryllium 10* 10" target.
35 - 40l50>
Long-lived target suited to long ir- $160,000 radiations.
Electron Linear Accelerators
Bremsstrahlung radiation on gold target produces high energy photons which strike beryllium target.
10* 109
35 40
Also suited to long irradiations.
$140,000
Cockroft-Walton Neutron Generators
Deuteron bombardment of tritium occluded in titanium produces 14Mev neutrons (which may be moder ated).
10* 109
57 <J,i
48 elements activated by one re- $ 20,000
search group.13,1 Thirty elements
to
boast of short-lived activities with at- 30,000
tractive detectabilities. These accel
erators require less restrictive safe
guards and installations.
4. The method is frequently interference-free.
The sensitivity for a given analysis is a function of the number of neutrons available for activation, i.e. the neutron "flux." Table I indicates that nuclear reactors have the highest fluxes and therefore acti vate the greatest number of elements. They are also the most expensive type of equipment to install.
The energy of the neutrons from either nuclear reactors or accelerators is usually reduced to thermal values by water moderation; these "slow" neutrons produce most of the useful reactions. In certain cases, however, only high energy neutrons (e.g. 14Mev) initiate the desired radionuclides18,25; accel erators meet this particular requirement better than reactors.
Following are a few examples of where neutron activation analysis has been applied successfully or where it has interesting possibilities:
l.In basic medical research, to determine trace elements in blood, bone and tissue.
2. In police work and criminal investigations, such as cases of arsenic poisoning or proof of the presence of traces of gunpowder. To in vestigate sources of hair, paint and other items of physical evidence. Coding and subsequent identification of drugs and narcotics.
3. To check the composition of semiconductors in the electronics industry.
4. In oil refining and processing, to determine trace quantities of vanadium, arsenic, nickel, copper, chromium and sodium in feedstocks.28
5. For the determination of trace quantities of oxygen in hydrocarbons, steel, beryllium and alkali metals in a variety of industries.27 A typical sequence for the determination of oxy gen by neutron activation analysis is outlined in Table II. Many of these steps can be traced in Figure 10.
6. In labelling and other tracer work which is probably the most familiar application of neu tron activation. The actual and potential appli cations of this are almost limitless. Radioactive
piston rings used in studying engine wear are one of many examples.
While the cost of neutron activation analysis will necessarily limit its general application, it is nevertheless helpful to know if this method is at tractive for a desired analysis. Reference tables25 and handbooks28 are useful in listing the neces sary parameters. Reviews18 which relate the expe riences of others are also helpful.
Without actually showing the exact equation which defines activation produced by neutrons, it is nevertheless interesting to review the significance of a few of its items. One is "cross section," the / experimentally-determined index of sensitivity to ^ activation by neutrons of a given energy. "Half-life" is another term, an everyday expression which de termines the limits for the irradiation time and the subsequent counting time. Knowing these param eters in addition to the available neutron flux and the detector efficiency, the minimum detectable amount of the element of interest can be easily calculated.
In addition to being relatively expensive, neutron activation analysis is also complicated. For example, knowing the theoretical detectability of a particular element is not enough; the analyst must also con sider the sample matrix for possible interferences with his accuracy. Direct interferences sometimes occur, i.e., elements other than that being analyzed may produce the same radionuclide that is used as rhe basis of detection. For example, fluorine inter feres in the fast-neutron activation determination of oxygen. In other instances, elements of high atomic number may "shield" the desired element from being activated by the neutrons, or they may absorb the weaker gamma rays emanating from the activated element.
A further limitation may result from counting similarities. For instance, two or more radio ele ments may have approximately the same gamma ray energies at a critical time in the detection of one of them. Radio-chemical separations very often re solve this difficulty. Since nearly half of the papers _
[8
DSW 202138
STLCOPCB4060205
Step No.
Operation
LUBRICATION
TABLE II
SEQUENCE OF ACTIVATION ANALYSIS - DETERMINATION OF OXYGEN
Equipment and Function
Remarks
1 Prepare sample.
Sample is weighed into polyethylene via! of low oxygen The C and H atoms of polyethylene are not activated. content.
2 Transmit sample to neu- Sample is moved by pneumatic pressure or by vacuum, tron flux.
3 Trip timing device.
Mechanical or photoelectric sensor detects sample and Identical activation time for sample and standard is pre
limits the activation time.
ferred.
4 Submit sample to timed Van de Graaff accelerator or neutron generator bombards
(30 sec) irradiation
tritium target with deuterons producing high energy neu
trons according to the reaction:
13 Dt 4- T| -- alpha particle -f neutron
The neutrons activate oxygen-16:
n + 08 -- N7 -t proton The nitrogen-16 decays with a half life of 7.3s
5 Terminate irradiation and return sample.
Timer operates the pneumatic system to remove the acti- The timer also alerts the counter to begin counting after
vated sample.
a preset delay.
6 Count for a preset time.
Multi-channel pulse height analyzer counts the gamma rays (6-7 Mev) from the N-16 decay.
A Nal crystal containing thallium detects the gamma rays. The photons of light thus produced are translated into electrical pulses by a photomultiplier tube. The gamma ray energy governs the voltage of each electrical pulse. The electrical pulses (counts) are sorted and stored in a com puter memory for later access.
7 Call for the counts.
Multi-channel analyzer produces "read-out". Information shown channel-by channel or as sum of channels of interest.
The analyzer is usually equipped to show this information visually on a cathode ray tube,
8 Calculate oxygen concentration.
Relate samples to counts obtained from standard oxygen sample.
^ referred to by Leddicotte18 require radiochemical separations, a continued need for a combination of instrumental and conventional technique is obvious. Prime attention must also be given to standardiza tion of the irradiation conditions. Since the neutron activation method is a comparative one, it requires the best possible measurement of the actual neutron dose which interacts with the sample.29 The total neutron dose or neutron flux measurement is very critical in the utilization of neutron generators whose targets deteriorate steadily with use.
Gas Chromatography
During the short time since the discovery of gas chromatography (GC) as a practical analytical technique in 1952 by James and Martin,4 it has be come one of the most widely used methods. The phenomenal growth of GC is due to its great ver satility, simplicity of operation, and relatively low cost. Its special forte is its ability to give quick, sharp separations of the components in a wide variety of samples. With it, many separations that are impractical or impossible by other techniques are easily obtainable. Two typical laboratory instru ments are shown in Figure 11.
Basically, gas chromatography is a process of physically separating the components of a sample as they are carried over a stationary phase by a mobile (gas) phase. GC is practiced predominantly in two forms--gas-solid chromatography (GSC) and gasliquid chromatography (GLC). In GSC, the sta-
tionary phase is a finely divided absorbent such as silica gel, alumina, or molecular sieves. GSC is gen erally limited in application to the analysis of fixed gases. The other form, GLC, is more versatile and thus more widely used. In GLC, the stationary phase consists of a thin layer of a non-volatile liquid, such as silicone oil, distributed on a finely divided solid support such as crushed firebrick, or on the inner wall of a capillary tube.
A gas chromatograph is a relatively simple instru ment consisting essentially of a sample inlet system, an inert carrier gas (mobile phase), a chromato graphic column (containing the stationary phase), a detector, and a recorder. A schematic flow diagram of a gas chromatographic instrument is shown in Figure 12.
Figure 11 -- Two typical gas chromatographs.
^ []