Document 37Oyx54eLGjgZe1yy2xrJ39a

4 V J. W. Gressler R. C. Lockemer ALGC - Safety, Health & Enviro. Affairs ALGC - Environmental Affairs 4-25-83 OSHA Progress Report - March, 1983 1. Summaries of personnel and area monitoring conducted during the month are presented in the attached tables and figures. 2. Geon East has made excellent progress in reducing the number of lights in B/464. Personnel exposures are also dropping. The efforts of the foremen and operators to minimize and correct leaks are clearly "paying off." 3. To ensure that respirators are worn when the potential for VCK exposure exceeds 1 ppm, Geon East has put up signs reminding employees to wear respirators when opening key pieces of equipment. 4. Geon West installed a new vent system on the No. 5 spray dryer bagger which has greatly reduced dusting and essentially eliminated clogging problems in the vent ductwork. \ RCL/fep DISTRIBUTION: B.R.Welch W.E.Horton C.Bayard J. R. Shellenberger D.D.Quester J.C.Meck R. C. Lockemer R.K.LaCosse T.J.Biskupich E.B.Katzenmeyer D. J. McDonald D.J.Barnicki J.C.Ritz T.S.Bialke H.VJalteroate J.S.Kiel-Ped. D.J.Gargas Dispensary '-A'TR. Denne NGC 18131 SUMMARY OF personnel monitoring Parameter Allowable Cone. 8 hr. TWA VCM* Plant B/432 B/438 B/449 B/451 B/452 B/4S4 B/455 B/4S7 - B/458 B/459 B/461 B/463 B/464 B/ 466 B/468 8/471 1 ppm \ March , 19a 3 No. of Samples Month Avg. Cone. 9 1.24 No. Above Allowable Year-To-Date No. Of Avg. Samples Cone, No. Above Allowable 2 53 .79 10 1 .16 1 .18 2 .16 1 7.25 4 -75 1 .42 1 1 -- 2 .42 5 7 .20 4 .14 1 .20 1 7.25 20 1.25 7 .60 4 .15 1 .13 CM 1 8 1 * Includes all long term monitoring with and without tasks ir.vir . 4-a NGC 18132 V SUMMARY OF PERSONNEL MONITORING .March 198 Parameter Allowable Cone. 8 hr. TWA No. of Samples Month Avg. Cone. No. Above Allowable Year-To-Date No. of Avg. No. Above Samples Cone. Allowable Dust Total 10 mg/m3 Respirable 5 mg/tn3 Noise 90-80-5 Metals Sb Cd Cr Pb M53 Other Breakthru Mar. 22% YTD 26% 85 dBA 5 500 Axg/m^ 200 -ug/m^ 500 .ug/m3 50 ^ug/m3 10 ppm 4 Area Personnel Monitoring B/451 B/461 B/463 B/464 65-86 2 25 62.97 13 64.05 7 40.61 3 .54 VC1 % Actual < 1 (No.) Month % ---- 4 -- 1 _-- 75 -- 100 . Year- to-Date (NO. ) % 2 20 __ 100 60 --_ 7 86 MGC 18133 <r > 1 PPM LONG TERM TEST NAME BATE OF TEST PPM RESP. JOB CODE EMPLOYEES DESCRIPTION OF WORK REDACTED 3-15 3-1 1.37 Yes 7.25 No 630 600 Recovery - B.D. - Lights Rodney Hunt Bldg. Strainers Screens on Abcor AREA 461 459 \ Envir. - 4-c me i 8134 7-21-82 I; \ GC % < L ppm 451 Personnel Monicoring Average ppm 451