Document 375oVYoZK1L4Gg15pbEnrdmmJ

',4;- .V-#T;. Monthly Sawiy Commiitttteeee RReeppoortrt.^ / ` ' *''' '/ ' ; A v* -*1 v '-; %r.2.'i,r''; 1'^' ' V' ' : ' (**/; /-- . ;,!:'4y4l)EPARTMENT 'OP LABOR AND INDUSTRIES7 J ; .IMVISION OF INDUSTRIAL SAFETY ANI HEALTli. 'it . J >i,kiJDv<W` ' -? -, I.**.. ` '* V' * V-'-.wfr. ' irm Name.-^ ' Texaco Inc.; ..... - ; ...- Humber of Empipyeea/^yElgf /.'<. ,i. ' '' ' , \. ] : yi':'' r :/>Vnirm'A&dresp ,P.- Q;>-Box-622 ". . . v . city Anacbrtes': zip:*W22`Uf^mlM .. /nv V ,./!/'T17 ; .... " *;"" . iy : f.'Type '.pf' Operat lon'X&fihirig-Oi 1 Petroleum Number- o) - 1 1,1 \ P ^mnl AxfObd no1 hfrtlvt* .fffffll* A ' , .. * ` v w ;.h? * Mvr,,, .rrVhr-wfcW/ . Date and Time of Next Committee Meeting' 8/28/6 ; ;' `-`V'.'.h'"'/; V* >)t EMPLOYES REPRESENTATIVES EMPLOYEE REPRESENTATIVES.:.; ;:'!;; [Aj- *& V ,t. k')1 * '' '/Members of'.the Safety Committee present and absent, j. .' ' .* !v'. ' See'Attached . -OV ^ i' .-.fe'/V ; { - - iV-v/;;.'Kv'.-.K: - , Attached/"%".?>/ .. : ' - ;- - . ........................ - .' .ijV-."it;etfX..- "..V.; 1 / . / .!> - i---' '. ?, .... ................................ ... _ wy-----f,r0iU-:--,-'Vi /-;vU-V~-.-i-- i *' `>lycr,-' '* %%'k' /./Do not'-limit this, report by saying no accidents happened last month.' - ./of''' l * V the/Safety Committee is' to ards -that could/'.ca ' Y***V*:v**1*!?>^'''Vaccidents and make recommendations % \ ,..;Ust visitors, discussions > reverse ; or .'additional sheets * using' original sequence numbers /Self Inspection items, education and training activities'should be1 listed >are discussed or.monitored by the committee. A copy of .this report should1 /kept-on file available for review for at least 12. calendar months. vt' * ' /-Record minutes of Safety Meeting below and on reverse See Attached M-AI7-A7 HOUTHIV SAPtTV COKHITTEE EEPORT 12-75 '' WA-TEX 004723 . . .i" . t-. }< T. WA-TEX004724 r> V i" PUGET SOUND PLANT GENERAL SAFETY MEETING MEETING NO. 3 - JTOY SI, 1980 t C, R. Rice, Chairman j,, L. Cutshall R. A. MacCulloch J. D. Drummond Members Present: A. Seeking J. R* HobsoA J. D. Sorg Visitors F. A. Codlin R. E. Terry R. L. Metcalf Members Absent D. R. Luehrs L. R. Halverson W. H. Curry The meeting convened at 3:00 p.m. and was opened by Chairman C. R. Rice. OLD BUSINESS A review of the open items from the June 26, 1980 meeting was made with the following items having been completed or otherwise disposed of: 6-2 5-1 6-14 6-15 12^11 6-17 6-8: Investigation revealed that existing drip pans are adequate and no change will be made. 6-9: It was determined that fourth post is not required and will not be installed. 6-10: Determination made that this is not a safety item but one of general maintenance. Window to be replaced. 6-18: Item evaluated and no change to be made. Each job is evaluated and number of employes assigned as required. . NEW BUSINESS A review of the Accident Analysis and Statistics^for the month of June 1980 was made with complete statistics appearing on page 8, . Zone Inspection Reports for the month of July were reviewed with items being carried forward as open items. : WA-TBX 004724 WA-TEX004725 General Safety Meeting -2 July 31, 1980 Mr. Cutaha11 was requested to present a Past Safety Committeeman pin to Mr. L. R. Halverson for his service and completion as a committee member. Meeting adjourned at 3s30 p.m. J. D, Drummond Secretary WA-TBX 004725 WA-TEX004726 General Safety Meeting 3 July'31, 198Q Location Disposition ZONE I VPS 6-1 Recommend installing platform at east end . of pump row for better access tp D. P. Cells and Plow transmitter, NDS--WO A21992 *. Being galvanized. 7-1 Replace missing chain at northeast entrance nds--investigate to unit. Paint entrance chains if needed. and recommend. SOUTH UNITS 7-2 Recommend investigating revisions to eliminate buildup of slime from water that continuously drips and runs across concrete pad in several areas, 6-3 Recommend investigating insulationon lines inside operator's shack as to hazard of asbestos contamination. NDS--WO 21458 NDS--Investigate and recommend. HTU-CRU #2 6-4 Make up Compressor 11PKM-102A & 102B. I.D. tag was found to have fallen off. Also Caution plates regarding flushing of oil lines was found to be painted over on 102A. NDS--Investigate and recommend. 6-5 Compressors have atmospheric oil coolers NDS--Investigate with improvised water flow over cooling fins and recommend. which create puddles and overhead drippings, Reaommend permanent modification. 7-3 Recommend modifying and extending work plat RLK--WO 21455 forms to Pin-Pan coolers. Also device for raising and lowering electric motors and fan belt hubs. '7-4 Replace missing guides that align trolley rails on htu #2, NDS--WO 21457 PCCU 6-6 Recommend installing guard posts at two fire hydrants on north side of unit. GAP--WO A-12638 6-7 Recommend investigating adequate method to clean sewers or repair so good drainage can be maintained. RET--Being investi gated. To be repaired during shutdown. ) WA--TEX 004726 l WA-TEX004727 General Safety Meeting 4 - July 31, 1980 Wo. Location Disposition ZONE X (Cont.) fcco (cont.) 7-5 Replace sample connection ground strap at 4B-C25 GAE--Investigate and recommend. 7-6 Recommend repainting yellow hearing protection required stripes at Waste Water Stripper Section. GAE--Investigate and recommend. #2 ARU 11-3 Investigate condensate pot stack going to atmosphere causing severe icing conditions during cold weather. FAF--Under investigation. POLY 7-7 Need cleanup of rags and insulation in area GAE--Investigate of 5J-C37 and C31., and recommend. ALKY #2 7-8 Recommend modifying and extending work RLK--WO 21455 platforms to Fin-Fan Coolers. Also.device for raising and lowering electric motors and fan belt hubs. ZONE II EFFLUENT PLANT 7-9 Recommend marking box located on east aids of road and north of Trickling Filter with yellow post and reflector, JTG--investigate and recommend. WAREHOUSE NO. 2 7-10 Repair broken vacuum suction hose to insulation band saw. RET--investigate and recommend. 7-11 Recommend relocating bundle puller rigging stored in doorway to ladder storage room. RET--investigate and recommend* WA-TEX 004727 WA-TEX004728 General safety Meeting 3 July 33., 198Q No. 6-34 6-12 Location zone II (Cent.) WAREHOUSE NOV 4 Recommend repositioning several pallets of material on racks to Insure stability. Possibly modify racks.. STOREHOUSE Recommend repair of asphalt along R/R tracks north of storehouse. Hazardous to use of 3 wheeled hyster. 7-12 11-6 Recommend markings on gas bottle storage rack be relocated so can be readily seen at all times. PAINT SHOP investigate adequacy of suction vent fan. GARAGE 12-7 Recommend modifying lifting lug on Lab. liquid waste bucket to conform to other lugger buckets. 7-13 Recommend checking brakes on flatbed truck GENERAL 6- 13 Recommend repair or replacement of R/R Crossing sign by Paint Shop. .7-14 Recommend check of Ballymore Scaffold handrails and repair as necessary. 7- 15 Recommend removing brush on east side of West Marches Point Road and south of South Texas Road. Disposition RET"~WD A30791 ' WHH--WO A3212.6 issued. To be included on paving contract. WHH--Investigate and recommend, FAF--Investigate and recommend. DPS--WO 32718 One complete* Work in progress. DPR.--Investigate and recommend. DPS--WO S403694 RET--Investigate and 'recommend. RQT--WO 31384 : W&-TEX 004728 WA-TEX004729 General Safety Meeting 6 July 31, 1980. NO, 7-16 7-17 7-18 7-19 7-20 7-21 7-22 7-23 7-24 7-25 Location ZONE II (Cont.) BOILERMAKER' SHOP Suggested that yellow barrier chain be permanently attached to columns at endsof tube pulling beams so can be readily placed as warning marker when tubes being pulled. EMPLOYES BUILDING Repair urinal flush valve at first stall in wash room. Secure lighting fixtures above mirror in wash room. FIRE EQUIPMENT Recommend repainting fire extinguishers as needed to prevent corrosion. GAS MIX DRUM Three signs need to be replaced. 2 - Automatic Start signs 1 - Danger Caustic Also general area cleanup needed, NO, 1 COOLING TOWER Replace section of bad decking at south east corner of mixing sump, ZONE III DOCK Recommend possible modification or re location of lights on dolphins A1-A2-B1B2 to keep from blinding personnel when docking ships. Reported that west finger pier swings excessively when tug is near. Recommend removal of non-used scaffold at Berth 3. Recommend handholds on ladders to boom baskets at Dolphin. A1 and A2. Disposition RET--Investigate . and recommend. * JDD--WO 31389 JDD--WO 31388 JTG--Investigate and recommend. JTG--Investigate and recommend. JTG--Investigate and recommend. GJF--Investigate and recommend. GJF--Investigate and recommend. GJF--investigate and recommend. GJF--Investigate and recommend. ! WA-TEX 004729 WA-TEX004730 General Safety Meeting , -7 - Jpiy 31, 1980: SSL!. Location SSONE III (Coat,) TMK FARM 'l.r-%^ Recortmend investigating hoisting device to raise and lower equipment used to gauge .and. sample tanks. 7-*27 Recommend investigating installation of lights on Tk.s 12, 13, 14 for gauging at night. BLENDING PLANT 6-16 Recommend new steps be made for jumpover at Lead Free Shipping Pumps. TRUCK RACK 7~,28 Recommend repair of loose mesh on east toeboard on north side of rack. 7-29 Recommend checking frayed cable on west toeboard on north side of rack. Possibly replace. GENERAL 7-30 Recommend barricading ditch near chlorine drums to Cooling Tower No. 1, Disposition GJF--Under i investigation. GJF--investigate and recommend. GJF--Work in progress. GJF--Investigate and recommend. GJF--Investigate and recommend. RET--Investigate and recommend. i WA-TEX 004730 WA-TEX004731 |N>to H H* H w Safety Meeting No. 3 PUGET SOUND PLANT ACCIDENT ANALYSIS AND STATISTICS -------------------3nnWD------------------------ 4ly 31/ 1980 s- I) Part; of Body Eyes-- w-- Face"'----'?:--"-- i Neck----- i Wrists--------------- 1 Back--------- 2 Fingers--,---- 1. Knees---,--------- - l Mult.Injuries-- 1 Jaw Bone---------------1 10 II) Nature of Injury Affected--'-------- I Bruises----- --------- *---- 1 Strains&Wrenches*------ 6 Wounds(Laceration)-- 1 occupational- Skin Disease or Disord.- 1 10 111 > Type o Accident Contact by Absorption----` 2 OVerekertion-Lifting-------- 3 Caught Between a Moving and Stationary Object;---------- 1 Struck by Plying Object----- 1 Fall On same- level------------ 1 Bodily^ Reaction From Invol. Motion------------- 2 10 IV) Source of Injury Metal Items (Wire)--1 Hydrocarbon Materials- 2 Waste Materials--------------- 1 Plywood----- ------------------------1 Hand Tools-Manual---------1 Hand Tools-Powered---- 1 Heating Equip.------------- 1 Piping-------------------------------- 1 Bodily Motion:---------------- . 1 10 V) Cause of Injury Inherently Hazardous Method or Procedure----- 2 Inadequately Secured Against Undesired Motion-------- -------------- ---------- -- l Failure to use available personal protective equipment------ ----------------------- ------- Taking wrong hold of objects----<-------------- -- Inattention to footing or surroundings------- Physical ability or condition of injured----- Alleged--------------------------- ------------------ ------------------- 10 Statistics 19 80 Month Year Manhours Worked-------------------- 59,234 304,733 19 79 Month Year 64,486 447,067 Minor Injuries---------------------- 10 34 11 67 Disabling Injuries-------------- 0 0 0 '0 Incidence Rate-"-- --------- 0 0 Date Last Disabling Injury t February 8, 1977 Days Since; 1238 Through June 30, 1980 Manhours Since; 2,614,679 Through June 30, 1980 WA-TEV 004731 WA-TEX004732 Union Representatives A. 07. Ferrario ' E. A* Betetzke Company Representatives __ _ ^ J. D, Drimimojp^frfeXACou.s.aTHouston D. L. Brown ENVIRONMENTAL AN<3 HEALTH The meeting began at 3s00 p.m. OLD BUSINESS '- AUG 11 '80 stJinc CHY June 24 as follows1; ttu.i EflK Item 9-1(79) Recommend investigating noise PRV test stand in Machine Shopf, CWD / rcH jL r0!M o _ G'i iTEfJLI' Disposition: Item being furt investigated. FILE SUBJECT \ } Item 12-1(79) Investigate Boilermaker Shop for potential fumes and dust problems. Dispositions Under investigation. Item 6-1 Pipe insulation' on the FCCU between Columns A7 and A8 north of Fractionator is reported as loose and rolls on the piping whenever anyone tries to walk on it. Disposition: Completed. Item closed. Item 6-2 It is reported that the street lights in the employe's parking lot are not on during nighttime shift changes. Also the parking curbs are not painted yellow which, in conjunction with lack of lighting, presents a tripping hazard. Disposition: Lights are on photo cell and come on at dusk and give enough light to adequately illuminate curbs. Item closed. NEW BUSINESS Item 7-1 Investigate potential fumes when handling and mixing chromate at #2 Cooling Tower. Disposition: Under investigation. JRS from FJB 8-11-80 WA-TEX 004732 WA-TEX004733 Joint Health' & Safety Committee "/'" ~2- ^ Ju^y; 34/:|'?80 ."V/ . .'/ Item 1-2 Investigate dusty conditions created .by old gunite machine. - ' - Disposition: Under investigation, ' 'AY' v^ . .;' '7";3 ;' - r -A : ;A'A'S-; Electric motors on #2 Alky may have fcad ' - rufeber::bdtip|:inga"Qver= the-; ei^dtridai 'A? ''-`v" -`coiihectibhs'^'V-YvY;\ :'Ya ;-y :Y;- . .;/ .'YY;. Y.;y, ' Disposition: Under investigation. r Y.;;Y'Y.Ya; .' i A-^Committee; discuasOdr seyerai- items of general health and safety natur#J" "fY" ' '. . ; Meeting adjourned at 3:45 p.m* WA-TBX 004733 WA-TEX004734