KEWANEE, indirect hot water heating coils
For STORAGE TANK Operation
O O ul
O O bl
SI NGL
L
DOU BL
1L
Coil No.
Size
S6-24 S6-30 S6-36 S6-42 S6-48 S6-54 S6-60 S6-66
S6-72 S6-78 S6-84 S6-90 S6-96 S6-102 S6-108 S6-114 S6-120
RATED CAPACITY
40" to 110" In Boiler Water
Surface Sq. Ft.
212 F
180 F
90 55 120 70 150 90 180 no 210 125 240 145 270 160 300 180
3.0
3.8 4.6 54 6.2 6.9 7.7 8.5
330 200
9.3
360 215 10.1
390 235 10.9
420 250 11.7
450 270 12.4
480 290 13.2
510 305 14.0
540 325 14.8
570 340 15.6
Number of
Ba.ths or Apart-
Trade Price Installed
1- 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19
$23.80 27.40 31.00 34.60 33.20 41.80 45.40 49.00
51.40 53.80 56.20
58.60 61.00 63.40 65.80 68.20 70.60
Size
D6-24 D6-30 D6-36 D6-42 D6-48 D6-54 D6-60 D6-66
D6-72 D6-78 D6-84 D6-90 D6-96 D6-102 D6-108 D6-114 D6-120
RATED CAPACITY 1
Gallons Heated 40" to 140" in 3 Hrs.
In BofW Water
Surface Sq. Ft.
Number of
Baths or Apart*
212* F | 180" F
i
Trade Installed
180 240 300 360 420 480 540 600
660 720 780 840 900 960 1020 1080 1140
110 145 180 215 250 290 325 360
395 430 470 505 540 575 610 650 685
6.0 ! 6 ! $34.60
7.6 : 8 1 41.80
9.1 10
49.00
10.7
12
53.80
12.3
14
58.60
13.9
16 i 63.40
15.4
18 | 68.20
17.0
20
73.00
18.6 20.1 21.7
23.3 24.9 26.4 28.0 29.6 31.2
22 77.80 24 82.60 26 ! 87.40
28 92.20
30 ' 97.00 32 i 101.80 34 I 106.60 36 111.40 38 116.20
S8-24 S8-30 S8-36 S8-42 S8-48 S8-54 S8-60 S8-66
S8-72 S8-78 S8-84 S8-90 S8-96 S8-102 S8-108 S8-114 S8-120
120 70 3.9
4
160 95 5.0 5- 6
200 120 6.0 6- 7
240 145
7.0
8
280 170 8.1 9-10
320 190
9.1 10-11
360 215 10.2
12
400 240 11.2 13-14
440 265 12.3 14-15
480 290 13.3
16
520 310 14.4 16-18
560 335 15.4 18-19
600 360 16.5
20
640 385 17.5 20-22
680 410 18.6 22-23
720 430 19.6
24
760 455 | 20.7 24-26
27.40 32.20 37.00 41.80 46.40
50.60 53.80 57.00
D8-24 D8-30 D8-36 D8-42 D8-48 D8-54 D8-60 D8-66
240 145
7.7
8
320 190 9.9 8-11
400 240 11.9 11-14
480 290 14.0
16
560 335 16.1 16-19
640 385 18.2 19-21
720 430 20.3
24
800 480 22.4 24-27
41.80 50.60 57.00 63.40 69.80
76.20 82.60 89.00
60.20
D8-72
880 530 24.5 27-30
95.40
63.40
D8-78
960 575 26.6 32 101.80
66.60
D8-84
1040 625 28.7 32-35 108.20
69.80
D8-90
1120 670 30.8 35-38 114.60
73.00
D8-96
1200 720 32.9
40
121.00
76.20 D8-102 1280 770 35.0 40-43 127.40
79.40 D8-108 1360 815 37.1 43--46 133.80
82.60 D8-114 1440 865 39.2 48 140.20
85.80 D8-120 1520 910 40.3 48-51 146.60
SS6L-63-636maenadnsDSLi8n-g4l2e mroewanofLo6npgipTees r3m6i"nalolncgo.ilsDf8o-r4283mRebanosileDrso.uble rows of 8 pipes 42" IonsCapacity data and prices for SL and DL coils are same as for S and D coils of identical sizes
OvneTiinono oVi 25+ oa Bi| a
Short Terminal S6, D6, S8, D8 also DN coils are interchangeable in all boilers including 83R IX and 2X series Long Terminal SL, DL and QN, TN coils are interchangeable only in 83R boilers 3X series and later Instantaneous Tankless Flow DN and QN, TN coils listed on reverse side of sheet.
LARGE VOLUME UNITS
KEWANEE INDIRECT COIL FOR HEATING DOMESTIC HOT WATER.
1'nlt No.
2D8-66 2D8-78 2D8-84 2D8-90 2D8-96 2D8-102 2D8-103
RATED CAPACITY
Gallons Heated 40 io 140 in 3 Hrs.
In Boiler Water
212"F
I80"F
Number of Baths or Apart ments
1600 1800 2000 2200 2400
2600 2800
960 1080 1200 1320 1440 1560 1680
50-53 53-60 60-67 67-74
74-80 80-87 87-94
T rade Price Installed
$153.00 169.00 185.00 201.00 217.00 233.00 249.00
Note substantia) fittings and generous size piping.
Single and Double Hot Water Coll Assembly consists o< -- Copper tubing brazed Into bronze fittings, brass bolted, ends tapped standard pipe thread. Locknuts with ring gaskets. Boiler steel mount ing plate. Full face sheet rub ber gasket. Twelve cadmium plated cap screws. Pressed steel frame.
3D8-81 3D8-90 3D8-96 3D8-102 3D8-108 3D8-120
3000 3300 3600 3900 4200 4500
1800 1980 2160 2340 2520 2700
94-100 110 120 130 140 150
265.00 289.00 313.00 337.00 361.00 385.00
Any Coils shorter than the maximum lengths listed on rc verse side may be sub>.titute*l in each boiler where less hot water capacity is required.
Boiler ratings do not include allowance for heating domestic v/atcr by Indirect Coils. Allow % sq. ft. of steam radiation, or .8 sq. ft of water radiation for each gallon of water heated.
For GRAVITY CIRCULATION with STORAGE TANK, capacity as listed above is the number of gallons raised 100" from 40"
to 140" in 3 hrs.
For summer use, and with intermittently fired fuels, use capacity listed with 180" Boiler Water.
FOR MAXIMUM LENGTH AND NUMBER OF COILS WHICH CAN BE 'N'.TAI I Fri err rrwrocr- -, r,r-
---------------
TRADE PRICES
Effective January 18, 1937
Kewanee indirect hot water heating coils
For INSTANTANEOUS FLOW
FOR SQUARE TYPE "R" BOILERS ONLY
Coil * Mo.
RATED CAPACITY
Gallons Heated *<T-H0 in 130
Boiler Water
i
Surface Sq. Ft.
In 1 Hr. 1 In 1 Min. i
Number of Baths or Apart
ments
Trade Price Installed
DNl
185 i 3.1 ; 12.3
i
$54.60
Coll No.
TNI QN1
FOR 83R BOILERS ONLY
RATED CAPACITY Gallons Heated 40*-140 in 180* Boiler Wat^r
In 1 Hr. In I Min.
Surface Sq. Ft.
Number of! Bathe or Apart ments
s
Trade Price Installed
185 3.1 12.4 240 4.0 15.9
1 : $54.60 6 63.40
1 __
DN2 DN3
240 15.9
295 j
4-9 ! 19.5
6 12
63.40 72.20
TN2 QN2
TN3 QN3
240 4.0 15.8 310 5.2 20.5
290 4.8 19.2 375 6.3 25.0
6 63.40 12 74.60
12 71.40 20 i 85.00
DN4 i
350 i
5.8
23.1
18
81.00
TN4 QN4
350 5.8 22.7 445 7.4 29.6
18 28
81.00 96.20
DN7 ; DN8
400 450
1
; i
6.7 , 26.7 i
75 ! 30.3 !
23 28
89.00 97.00
00
in ! i
DN9 i 510
33.9 34 106.60
TN7 QN7
TN8 QN8
TN9 QN9
390 6.5 26.1 1 23
87.40
510
8.5
34.2 1 34
j 106.60
445 7.4 29.6 ! 28
96.20
580 9.7 38.8 | 40 ; 117.80
495
8.3
33.0 1 34
1 104.20
650 10.8 43.4
48 1 129.00
25 + .16 0*1-
2S + .1* gal.
r INSTANTANEOUS Flow, capacity as listed above is the number of gallons raised 100" from 40" to 140" in 1 hour with
iler water at 180.
Boiler ratings do not include allowance for heating domestic water by Indirect Coils,
hen the INSTANTANEOUS Tankless hot water demand is added to the heating load for more than ten minutes in any hour,
allowance of 4 sq. ft. of steam radiation or 6.4 sq. ft. of water radiation must be added for each gallon of water heated,
ils for Gravity Circulation with Storage Tank listed on front side of sheet.
MAXIMUM LENGTH AND NUMBER OF COILS FOR KEWANEE BOILERS
TYPE "C" BOILERS
SQUARE TYPE "R" BOILERS
For
., ,r
773 774 775 776 777 T78 179
7te1o1
783 784 7S5 786 787 788 789 790
STORACE TANK Operation
INSTANTANEOUS Flow
Maximum Coll Length
Inches
Maximum No. of Coils
Per Boiler
Maximum Size and No.
Per Boiler
42 i 1--DN4 48 1 1--DN7
60 1 1--DN9
72 i 1--DN9
66 2
72 2
84 2
78 2
96 2 84 2
Balance
96 2 102 2
On
120 2 114 3
Application
120 3
120 3
120 3
120 3
For STORAGE TANK Operation
INSTANTANEOUS Flow
Boiler Number
742 743 745 746 747 748
Maximum Coll Length
Inches
36 42 42 48 54 60
Maximum No. of Colls Per Boiler
i i i i i i
Maximum Size and No.
Per Boiler
1--DN3 1--DN4 1--DN4 1--DN7 1--DNS 1--DN9
83R1 83R2 83R3 83R4 83R6 83R7 83R8 83R9
83R OIL OR GAS BOILERS
24 1 1--TNI, or QN1 30 1 1--TN2, QN2 36 1 1--TN3, QN3 42 1 1--TN4, QN4 42 1 1--TN4, QN4 48 1 1--TN7, QN7 54 1 1--TN8, QN8 60 1 1--TN9, QN9
fer to separate Type "R" price sheet for complete data on Coils for Square and Round Type "R" Boilers.
fer to Catalog 88h for Data and Measurements on Square "R" Boilers with Coil assemblies and to Catalog RG-92d and C-92b Coils in Round Type "R" Boilers. ces and Information on application for Coils which can be installed in other boiler series not covered by this sheeL
:en domestic hot water supply is furnished by Instantaneous type submerged heater, it usually advisable to use a mixing ve or other reliable equipment to control the maximum temperature of water at all outlets,
far to current General Boiler Price Sheets for: Terms, Claims,-Guarantee, etc. prices herein quoted supersede all prior quotations and are subject to change without notice.
KEWANEE, 9ILER (Q?RP9RAT|on KEWANEE, ILLINOIS
TRADE PRICES
Effective January 18, 1937
KEWANEE 15 Pounds Working Pressure Steel Heating Boilers Round and Square "R" Welded Boilers Indirect Hot Water Heating Coils
All prices herein quoted supersede all prior quotations and are subject to change without notice.
On occasion of any advance in the schedule of prices herein quoted, only orders actually mailed, to us or to Jobbers representing us, before such advance in price is made will be invoiced at the price effective prior to the advance.
Built to American Society of Mechanical Engineers Boiler Code
While this code is the latest ruling Issued by the A.S-M.E. Code Committee to govern the construction of boilers, it is used by Kewanee only as a minimum limit. In all our boilers the construction is above the code requirements, based on our 68 years experience as to what is required to make a boiler that will give long and satisfactory service.
ALL KEWANEE BOILERS ARE UNIFORMLY RATED
Ratings are in conformity with the Steel Heating Boiler Institute's Code for Rating Low Pressure Heating Boilers.
GENERAL TERMS, GUARANTEE, ETC.
TERMS: 5 per cent discount for cash within 15 days from date of invoice or 30 days net cash. On allpast-due accounts the legal rate of interest will be charged. Cash Discount on Trade Prices before addition of surcharge..
CLAIMS: As all goods are shipped at buyer's risk, they should be examined carefully before he signs railroad receipt. If transportation company tenders delivery of goods in bad order, buyer should insist on railroad agents making notation of con. dition on freight bills, thus enabling buyer to secure prompt payment of railroad claims which may be filed'by him for value of the damaged material.
The responsibility of this Corporation ceases upon delivery of goods in good order to transportation companies. All orders are acceoted subject to strikes, accidents, or other causes beyond our control.
GUARANTEE: Our goods are guaranteed only to the extent of furnishing by freight new parts for any found defective in manufacture. No claim will be allowed unless presented within 60 days after receipt of goods. Goods must not be returned except by special permission and when so returned will be subject to discount.
FREIGHT SURCHARGE FREIGHT TERMS: The following freight terms will apply on shipments of Kewanee Low Pressure Steel Heating Boilers:
F. O. B. Kewanee with the addition of freight surcharges outlined below In cents per hundred pounds, and with an allow ance of full freight to nearest railroad point of destination in zones listed.
SURCHARGE IN CENTS PER HUNDRED POUNDS
|
A.....................1 B..................... ' C................... D.....................1 E..................... 1 F..................... : G.............
LESS CARLOAD
Surcharge
Weight
$ .60 $ .95 $1.25 $1.70
$2.10 $2.45 $2.85
Listed Weights
Caution-- L.C.L. Surcharge Is Not to Exceed
the Minimum C L. Surcharge
Weight Limit for L.C.L. Surcharge
10000 lbs. 12630 lbs. 13400 lbs. 12700 lbs. 12570 lbs. 12730 lbs. 12630 lbs.
CARLOAD
Surcharge
Weight
$ .25 $ .50 $ .70 $ .90 $1.10 "1.30 $1.50
Listed Weights
But Not Less Than 24000 lbs.
STATE--Zone
ALABAMA ..............-.............. B
ARIZONA ................................ G
ARKANSAS ...............
C
CALIFORNIA ...................... G
COLORADO .................... -...... F CONNECTICUT ..............--. A
DELAWARE .......................... A DIST. OF COLUMBIA .... A
FLORIDA ........................... C
GEORGIA ............................... B
IDAHO ....................................... G
ILLINOIS ..........
A
STATE--Zone
INDIANA.......... .................... A
IOWA ....
B
KANSAS ............
D
KENTUCKY ................. -- A
LOUISIANA........ ..... ..... .... - C MAINE.............. ......... -......... A MARYLAND ........................ A
MASSACHUSETTS ........... A
MICHIGAN .....
A
MINNESOTA ... ..................... B
MISSISSIPPI ....................... B
MISSOURI
............-- B
STATE--Zone
MONTANA ............................ G
NEBRASKA ......
D
NEVADA .................................. G
NEW HAMPSHIRE ............ A
NEW JERSEY _____ ______ A
NEW MEXICO .....
F
NEW YORK ........................... A
NORTH CAROLINA .......... B
NORTH DAKOTA .......
D
OHIO ...............
A
OKLAHOMA ........................... D
OREGON .........-..................... G
STATE--
Zone
PENNSYLVANIA __
A
RHODE ISLAND ................ A
SOUTH CAROLINA ............ B
SOUTH DAKOTA .............. D
TENNESSEE ............
A
TEXAS .......__......................... E
UTAH ....................................... G
VERMONT ____
A
VIRGINIA .........
A
WASHINGTON ____
G
WEST VIRGINIA ................ A
WISCONSIN ....................... A
WYOMING ............................... F
Kewanee. biler Corporation
division of American Radiator and Standard Sanitary Corporation
KEWANEE, ILLINOIS
TRADE PRICES
KEWANE6. ROUND TYPE "R" STEEL HEATING BOILER
15 lbs. Steam W. P., 90 lbs. Water W. P., 135 lbs. Hydrostatic Test
This Round "R" Boiler for homes and smaller buildings is a real vanee, strongly built of Steel for Long Life of heavy duty performance.
High Class Kewanee workmanship is reflected thruout. The refractory hated doors are smooth ground to a gas-tight finish on the heavy nes. The Two-Pass tubes give higher efficiencies, 80% and up. Addially for oil, gas or stoker the Spinner Blades and self-actuated Draft uster have a big plus value. There is no extra charge for these.
Accessibility for cleaning permits keeping the Efficiency high. The neat and pleasing Jacket which houses these dependable Type "R" lcrs may well be a deciding factor which will influence the owner to ct one of our heating units for his modern basement or for wherever rt exterior trim is considered an essential. Kewanee offers 4 styles. First there is our Round Jacket, a snug fitted sheathing of insulated 1. Takes up less room than any other Jacket. Exactly the thing for id Firing or where equipment for Mechanical Firing is to be completely .ssible. With the new Smartline Regal Jackets complete enclosure is red for Any Gun Type burner with our boiler. The Square-Regal ket is a choice for Rotary Burners, also will enclose foreshortened i Types. Or in outside assemblies, either front or rear fired, whichever referred, the Smartline Rex Square Jacket is available. Only with Kewanee is this wide range of choice in Regal, Square and ind Jackets available. Its low purchase price, low installation cost and upkeep, make the vanee cheaper to buy and operate than any other on the market. First t includes regular Hot Water Heating Coil for Domestic Tank Supply,
a Big Coil may be ordered. And for Instantaneous Flow without rage Tank, there is the Kewanee Instantaneous Coil.
All Kewanee Copper Coils fit inside the boiler and are interchangeable.
ROUND TYPE "R" BOILER FOR BURNING COAL.
FOR BURNING COAL
BITUMINOUS COAL 735-736 SERIES ANTHRACITE COAL OR COKE 2735-2736 SERIES
[RATED CAPACITY RECOMMENT*ED
oiler 1 So
!
Steam 1 W.tfr
1
SQ. FT EDR Steam | Water
J5 I 410 | 660 !! 320 56 j 550 1 880 I 423
512 6"7
TRADE PRICE uni be Added
Stum Water
Weight
upon which Surcharge la based
Safety Vain
DEDUCTIONS FOR OMITTING REGULAR PAR-TS
Steam or Altitude Gauge
Regulator 1 aod Gauge Cocks
COMPLETE TRIMS Steam 1 Water
CRATES Prlct | Weight
BASE Price E Weight
$121. 143.
-UNJACKETED
$118. ; 1040 ; $1.00 $2.00 $3.00 140. | 1280 | 1.00 2.00 3;00
$2.00 2.00
$8.00 $5.00 $3.50 | 75 $6.50 145 8.00 , 5.00 4.50 | 100 7.00 | 155
--WITH ROUND JACKET
55-J 1 410 | 660 J6-J 550 880
320 512 i $136. $133. ! 1230 ; $100 $2 00 $3.00
423 677 161. 158. 1495
1.00 2.00 3.00
$2.00 2.00
$8.00 , $5.00 $3.50 j 75 8.00 : 5.00 4.50 100
SEE FIRST PAGE FOR SURCHARGE WHICH MUST ALWAYS BE ADDED TO TRADE PRICE. Tools furnished with Boilers for Coal consist of Poker, Soot Scraper, and Flue Brush. If omitted deduct $1.00.
$6.50 | 145 7.00 : 155
KE.WANEL INDIRECT HOT WATER HEATING COILS
oiler inlier
734
735 & 736 736
For STORAGE TANK Operation
Coll St2e
F-34 B-34
F B DB-35 DB-36
RATED CAPACITY
Gallons Heated 40* to 140* In 3 Hra.
In Boiler Water
212* F 1
1 65
95 l 11
75 1 no | 170 ' 200
180* F
40 60
45 65
100
123
| | '
Surface S< i. Ft.
2.0 3.0
24 3.5 5.6 6.6
Add to Trade Price
Is Regular Equipment $ 5.00
Is Regular Equipment $ 6.00 $10.00
$12.00
Coll Size
For INSTANTANEOUS Flow
RATED CAPACITY Gallons Heated 40*-140* in 180 Boiler Water
In T Hr In l Min.
Surface Sn. Ft.
Add to Trade Price
JDN-35 DN-36
i | 170 i 2.9
11 11 1 190 1 3.2
11.4 12.9
$21.00
$23.00
TRADE PRICES
KE.WAN&& ROUND TYPE "R" STEEL HEATING BOILER
15 lbs. Steam W. P., 90 lbs. Water W. P., 135 lbs. Hydrostatic Test
SMARTLINE SQUARE-REGAL JACKET
PROVIDES COMPLETE ENCLOSURE WITH ANY ROTARY BURNER, AND WITH ANY FORESHORTENED GUN TYPE BURNER,
SMARTLINE REX SQUARE JACKET
FOR ANY BURNER.
WITH EXTENSION PANEL, PROVIDES COMPLETE ENCLOSURE FOR ANY GUN TYPE BURNER.
FOR OIL, GAS OR STOKER
boiler
No.
OIL OR GAS 1734-1735-1736 SERIES
K\TEH CAPACITY
! 1Steam
1
Water
RECOMMENDED
NET LOAD
l. SQ. FT. EDR. 1 |Water
TRAOE PRICE
t> lhkb Surcharge
max W Added Strut | Water
Weight opoo wbkb Surcharge
is based
STOKER 0735-0736 SERIES
DEDUCTIONS
Si/et; Valve
Steam or Altitude Gauge
FOR OMITTING REGULAR
Water Gauge
and Cauge Corks
COMPLETE TRIMS
Steam |
Water
PARTS BASE
Priee
Weight
1734 1735 1736
400 540 680
, ,
640 860 1090
It 400 i; 540
ii 680
640 ||
860 ,|
1090 ||
$ 93. 110. 132.
--UNJACKETED
$ 90.
800
107.
920
129. | 1130
1 $1.00 | $2.00 l 1.00 | 2.00 1 1.00 | 2.00 |
$2.00 2.00 2.00
$5.00
5 00
| 5.00
$2.00 $3.50
2.00 6.50
2.00 | 7.00
50 145 155
l735-J 1736-J
1734- M 1735- M 1736-M
-WITH ROUND JACKET
540
860 540 860 ; $125.
$122.
1110 i $1.00 | $2.00
$2.00
$5.00 $2.00 $6.50 145
680
1090
680 1090 . 150.
147. 1 1345 i 1.00 | 2.00 1
2.00
| 5.00
2.00 | 7.00 155
--WITH REX SQUARE JACKET
400 540 680
640 860 1090
|! 400 1 640 ;,
'i 540 | 860
ii 680 i 1090 ,,
$110. 130. 155.
$107. | 1000 i 1.00 |
127. | 1130 L 1.00 | 152. i 1370 i 1.00 |
2.00 2.00 2.00
| |
i
$2.00 2.00 2.00
| $5.00 | 5.00 | 5.00
$2.00 | $3.50 2.00 6.50 2.00 7.00
50 145 155
--WITH SQUARE-REGAL JACKET
1734-MQ 1735-MQ 1736-MQ 1
400 540 6e0
1734-MG , 1735-MG 1 (1736-MG |
400 540 680
640 860 1090
ti 400 640 , 540 : 860 ,
i' 680 j 1090 ;
64 C 860 1090
400 540 1 680
640 860 1050 |
$120. 140. 165.
$130. 150. 175.
$117. i 1100 137. ; 1200 162. | 1450
i $1.00 t $2.00
, 1.00 1 2.00
i 1.00 | 2.00
-WITH REGAL JACKET
$127. , 1200 147. , 1300 172. ' 1500
I $1.00 | $2.00 I 1 00 1 2.00 i 1.00 | 2.00
1 | |
$2.00 2.00 2.00
$2.0C 2.00 2.00
$5.00 5.00 5.00
$2.00 2.00 2.00
$3.50 6.50 7.00
50 145 155
$5.00 5.00 5.00
$2.00 | $3.50 2.00 6.50 2.00 7.00
50 145 155
SEE FIRST PAGE FOR SURCHARGE WHICH MUST ALWAYS BE ADDED TO TRADE PRICE.
rt
~ -1
-l.j ,VJ*U OaIUf *fsr Oi? Ga
Trimmlnf nr
TRADE PRICES
KEWANtE, SQUARE TYPE "R" WELDED BOILER
ED CAPACITY .
I' tin Water j
RECOMMENDED so. rr EDL
Slum Water
)0 1260 || 605 [ 968 10 1600 H 770 | 1232 >0 2160 |, 1035 j 1656 >0 2560 1230 | 1968 :0 2850 |; 1370 | 2192 10 3140 1515 | 2424
BITUMINOUS COAL 742- 748 SERIES ANTHRACITE COAL OR COKE 2742-2748 SERIES
Boiler Nft.
TRADE PRICE I* riudi Sarcfcargt
aulNiiM
Steam Water
Weight upoo which Surcharge
is based
I
BoUer No.
|
trade price
ta which Surcharge mut be Added
1 Steam ^ Water
upon
Surcharge is based
DEDUCTIONS FOR OMITTING
COMPLETE TRIMS
Steam
irittf
GRATES t CAST IRON' BASE
1| Price |n>l(ht t Prtr* ^ Wright
--UNJACKETED
742 $255. |$252. | 2150 743 272. | 269. | 2360 745 300. | 296. | 2800 746 321. | 317. j 3050 747 335. | 331. | 3300 748 384. | 380. | 3550
--JACKETED
742-J | $290. | $287. 743-J 1 309. | 306. 745-J ; 340. | 336. 746-J , 362. | 358. 747-J , 378. | 374. 748-J 1 429. | 425.
2355 2585 2975 3240 3500 3775
$10.00 10.00 11.00 11.00 11.00 11.00
$7.00 7.00 7.00 7.00 7.00 7.00
$7.00 165 , $15.00 7-335" 8.00 | 200 , 16.00 , 360 9.00 | 215 , 17.00 ; 370
10.00 , 250 | 19.00 j 415 11.00 , 285 ; 20.00 i 440 12.00 . 320 , 22.00 ,485
OIL OR GAS 1742-1748 SERIES STOKER 0742-0748 SERIES
.D CAPACITY , RECOMMENDED
SCt. FT. EDI.
.a
Water ;'t I
Steam
1 Water
i TRADE PRICE
Boiler No.
ta which Surcharge mast be Added
Steam | Water
Weight upoo vbKb Surcharge Is based
Boiler No.
TRADE PRICE to which Surcharge
must be Added
Steam j Water
i | Weight [ upon | Surcharge
Is based
DEDUCTIONS FOR OMITTING
COMPLETE TRIMS
CAST IRON BASE
Steam
| Water
Fnce
i Wrigbl
0 1340 ,, 645 | 1032
:o 1790 u 860 | 1376
'0 2350 |, 1130 1 1808 )0 , 3040 |, 1500 , 2400 ;o 3460 n 1670 | 2672 so 3810 ,| 1843 ! 2949
--UNJACKETED
1742 1743 1745
$226. |$223. 24b. | 243. 270. \ 266.
1900 2060 2500
1746 300. | 296. 2730
CO
CO
4*
CO
1747
2920
1748 350. { 346. 3125
--JACKETED
1742-J 1743-J 1745-J
$261. | $258. | 2105 283. | 280. | 2285 310. | 306. | 2675
1746-J 341. | 33/. | 2920
1747-J 361. | 357. | 3120
1748-J 395. | 391. | 3345
$5.00 1 $2.00
$15.00 | 335
5.00 1
*-oo
16.00 | 360
6.00 |
2.00 j
17.00 | 370
6.00 |
2.00
19.00 | 415
6.00 |
2.00
20.00 | 440
6.00
1
2.00 |
22.00 | 485
EE FIRST PAGE FOR SURCHARGE WHICH MUST ALWAYS BE ADDED TO TRADE PRICE.
deductions:
Safety Valve, Boilers 742-3....$1.00 745-8....$2.00 Damper Regulator....$5.00
Water Gauge and Gauge Cocks....$2.00
Steam or Altitude Gauge....$2.00
IMMINGS--for Coal: Steam Trimmings consist of Safety Valve, Steam Gauge, Damper Regulator, Water Gauge, Glass and Gauge Cocks.
Hot Water Boiler trimmings consist of Combination Altitude Gauge and Thermometer, also Damper Regulator. --for Oil, Gas or Stoker:
Steam Trimmings consist of Safety Valve, Steam Gauge, Water Gauge, Glass and Gauge Cocks. Combination Altitude Gauge and Thermometer only trimming furnished with Hot Water Boilers.
DLS-- --for Coal:
Tools furnished consist of Hoe, Poker, Soot Scraper and Flue Brush. If omitted deduct $2.00.
--for Oil, Gas or Stoker: A Flue Brush is only tool furnished.
All Jacketed Boilers have indestructible baked enamel steel jacket, lined with multi-ply improved asbestocel insulation. Knock-out discs are provided in Jackets opposite boiler openings. Additions for Extra Equipment listed on back page 8.
SQUARE TYPE "RM BOILERS FOR ALL FUELS
TWO-PASS TUBES AND CAST IRON BASE. TWO-WAY SMOKEHOOD FOR BURNING COAL.
FOR OIL, GAS OR STOKER, SPINNER BLADES INCLUDED. STEEL BASE MAY BE SUBSTITUTED FOR CAST IRON. TWO-WAY DRAFT ADJUSTER, REVERSIBLE FOR TOP OR END OUTLET, HAS 1-5,16" DIAMETER STACKSTAT OPENING. TAPPED OPENING EITHER SIDE OF SHELL CAN BE USED FOR AQUASTAT.
KEWANEE INDIRECT HOT
WATER HEATING COIL
t.. I'urn'-h. d on all Soi.arv
H ' Dollars ai extra ruxl, h>tvd
page
All have coil opening,
and a. .apped each side for Ex-
c. I... .iter heater
TRADE PRICES
KE.WANEE. | SQUARE "R" OIL OR 6AS BOILER
83 "IT OIL OR GAS SERIES
RATED capacitt Steam Water
RECOMMENDED
NET LOAD SQ. FT. EDIL
Stum
Water
Boiler No.
TRADE PRICE tt trtich Surcharge
ttdbtRddtf
Steam Water
Weight upoo which
Surcharge is based
Boiler No.
TRADE PRICE to which Sirtharyc
Weight
at to AIM
upon
which
Surcharge
Steam Water is based
Boiler No.
TRADE PRICE __ , te ubicb Surcharge ,*jbc
DEDITT FOR OMITTINC
amt to Added .
COMPLETE TKIMSj STEEL
j < Steam
Surrharge Water ' is based
Mllpr Prii-f OVtc!
--UNJACKETED
--JACKETED
-REGAL JACKET
901 1441 i| 901 1441 |83R1 |S161. |$158. 1135 83R1-J $198. ($195. 1300 83R1-G |$218. ,$215. 1300 S5.00 $2.00 $7.00 145
1105 1768 || 1105 1768 83R2 1 182. 1 179. 1175 83R2-J | 219. , 216. 1350 83R2-G 1 241. 238. 1350 5.00 , 2.00 ; 7.50 15C
1226 2121 || 1326 2121 83R3 | 204. 1 201. 1320 83R3-J 1 250. | 247. 1520 83R3-G | 275. 272. 1520 5.00 | 2.00 | 8.00 16C
1513 2420 || 1513 2420 83R4 | 231. 1 228. 1430 83R4-J | 277. | 274. 1650 83R4-G i 305. 302. 1650 5.00 | 2.00 j 8.50 170
2091 3345 || 2091 3345 83R6 | 269. 1 265. 2030 83R6-J | 315. | 311. 2300
6.00 | 2.00 | 8.50,175
2363 3780 || 2363 ] 3780 83R7 | 348. 1 344. 2430 83R7-J 1 394. | 390. 2700
> 2652 4243 || 2652 4243 83 R8 | 368. 1 364. 2610 83R8-J i 414. | 410. 2900 2924 4678 1! 2924 4678 83R9 { 386. 1 382. 2990 83R9-J 432. ; 428. 3300
6.00 l 2.00 | 9.00 | 185 6.00 : 2.00 | 9.50 195 6.00. 2.00 10.00 200
SEE FIRST PAGE FOR SURCHARGE WHICH MUST ALWAYS BE ADDED TO TRADE PRICE.
DEDUCTIONS: Safety Valve, Boilers 83R1-83R4 $1.00. Safety Valve, Boilers 83R6-83R9..... $2.00.
Water Gauge and Gauge Cocks, Boilers 83R1-83R9....... $2.00.
Steam or Altitude Gauge,
Boilers 83R1-83R9........$2.00.
TRIMMINGS--for Oil or Gas: Steam Trimmings consist of Safety Valve, Steam Gauge, Water Gauge, Glass and Gauge Cocks. Combination Altitude Gauge and Thermometer only trimming furnished with Hot Water Boilers.
TOOLS
J
--for Oil or Gas: A Flue Brush is only tool furnished.
All Jacketed Boilers have indestructible baked enamel steel jacket, lined with multi-ply improved asbestocel insulation. Knock-out discs are provided in Jackets opposite boiler openings. Additions for Extra Equipment listed on back page 8.
I
)
SQUARE "R" OIL OR GAS JACKETED STEEL BOILER 83 "R" SERIES
TWO-PASS TUBES AND STEEL BASE. ARE INCLUDED.
SPINNER BLADES
TWO-WAY DRAFT ADJUSTER, REVERSIBLE FOR TOP OR END OUTLET, HAS 1-5/16" DIAMETER STACKSTAT OPENING. TAPPED OPENING EITHER SIDE OF SHELL CAN BE USED FOR AQUASTAT.
Tapered Sides on 83R1-83R4 also 742-743. Straight sides on 83R6-83R9 also 745-748.
with Regal Jacket for complete enclosure with any burner,
four sizes only 83R1 to 83R4
Photos of Front and Rear view unretouched
KEWANEE INDIRECT HOT WATER HEATING COIL
may In- furnished on ail Squar*' R ' Koik-r? at extra coct Ii'-icd pagp S. AM have cull opening, ami arc lupprd t-ucli side fur Exodso water heater.
TRADE PRICES
KE.WANEE. ROUND
Hot Water Working Pressure 90 lbs. per sq. in
TYPE
t
"R" STEEL; WATER NEATER KEWANEE STEEL TANKS FOR STORAGE WATER
HydroMJflC Test, 135 lbs. per sq in
(EWANEE ROUND "R" HEATER
w ^ Drain
STEEL MVETED TE$ ADO WELDEO TANKS
STAN DA R P'-lEXTR A HEAVY
Working Pressures: 751b*. sq. In.1 100 lbs. sq. in '
CAPACITIES: Welded Tanks 66 .gals..to 525 gals. Riveted Tanks 66 gals, to .13,000 gals, and up.
For thebest operation In' practice,;.the Storage Water Tank should have a capacity not less* than the 3-h'our1 capacity of,'the 'Heater.';
Prices on black Hot ,Water Storage. Tanks, Riveted
or Welded, and. on' Galvanized Tanks furnished ori
application.
`.
FOR SOFT COAL, HARO COAL OR CORE Copper Tubes, Heavy Rocking Grates and Two-Way Smokehood
OR FOR Oil, GAS OR STOKER Copper Tubes with Spinner Blades Self-Actuated Draft Adjuster
HIGH EFFICIENCY and HOT WATER FOR DOMESTIC- SERVICE AND larger Storage tank supplies
THE Kewajnee ,ROUND *: R"! ;DIRECi WATER HEATER . and STORAGE TANK :
KEWANEE ROUND "R" STEEL WATER HEATER
FOR BURNING COAL --WITH ROUND JACKET
Heater No.
CAPACITY Gals, per 3 hrs.
100 deg. raise
i
Trade
Price to which Surcharge I must be 1 1 Added |
735-HJ | 736-HJ |
700 800
$181. 201.
Weight upon which Sur
charge is based
1230 .1495 ;r
DEDUCTIONS I* OR OMITTING
Grates
Base
1
Price
Weight 1 Price Weight
$3.50 75 $6.50 145
4.50 y 100
7.00 155
735-H 736-H
UNJACKETED
| 700
$166.
1040 $3.50
75 $6.50
! 800 1 183. , 1280 4.50 100 7.00
2735-HJ, 2736-HJ prices same as 735-HJ, 736-HJ
1457 155
FOR OIL, GAS OR STOKER -- WITH ROUND JACKET
1735-HJ 1736-HJ
750 | $173. 1110 900 193. 1345
$6.50 145. 7.00 155
1 -UNJACKETED *
1734-H 1735-H 11736-H
550 j $121. 750 1 158.
900 i 175.
800 |
920 1 1130 1
! 1
! $3.50 50 ! '6.50 145' 1 '. 7.00 ! 155
0735-HJ, 0736-HJ prices same as 1735-HJ, 1736-HJ
See page 7 for specifications of Equipment on Water Heaters for any fuel.
This high quality all-steel/ equipment with copper-fire, tubes serves splendidly for volume heating and storage insuring . continuous service / p piping hot water. Capaci ties 550-900 gallons ;raised; 100 in 3 hours.. ( ,, , ;
735-H, 736-H heaters are for Bituminous'Coal:
2735-H, 2736-H; heaters are: for Anthracite Coal or Colte.
1734-H,1735-H,1736-H heat ers, are for Oil or Gas.
0735-H, 0736-H heaters | are for Stoker.
t Round ,"R" Direct.' Water Heaters Have; copper1 tubes' Nq coil is furnished. '///.if
SEE FIRST'PAGE FOR SURCHARGE* WHICH MU AT ALWAYS BE ADDED TO trade PRICE. j)
J J
-- SPECIFICATIONS and MEASUREMENTS --
KE.WAN&E. ROUND TYPE "R" DIRECT WATER HEATER K&WANLE, ROUND TYPE "R" STEEL HEATING BOILER
For Heating with--
| |jBituminous Coa'l
Oil, Gas, or Stoker
With Hot Water H< ating Coil
Boiler or Heater Number.............-......
735 2735
2773366 11
1734
1735 0735
1736 0736
Boiler Rating--Steam ...................... _sq. ft. --Water ...............................q. ft.
410 660
550 1 880 |
400 640
540 680 860 1090
Heater Rating--Gallons per 3 hr*. 100 raise
Heating Surface ............................................sq. U. Grate Area ............................... ...................sq. ft. Furnace Volume ..................... -........-......... cu. ft.
700
32 2.9
800 , 40 '
3.7 --
550 24
3.7
750 32
5.4
900 40
7.4
Boiler or Heater Shell Diameter.....................In. Boiler or Heater Shell Height--------- ---------In. Inside Diameter ............. -...... -..... -..................in.
27'/, 43 23
30' '> 47 26
23% 42'/,
20
27'/,
43 23
30'/,
47 26
Smoke Outlet Diameter...................................In.
Chimney Size ------------- ---------------------------------In. Chimney Height ........ -................. --............. ft.
Flow Outlet Size ______ ____--..... ......... ......--In.
Return Inlet Size .
.................................... -In.
Safety Valve Size .................. ............................--in.
Water Heater Pipe Connection.......................In.
A--Height Over-All ...................................... in. B--Base Diameter ................................. .......... n.
--Water Line ...................................................... in.
9 8x12
30
4 4
1 1 55'/. 32>/g 44
9 8x12 ,
35
4; 4 1 1
59* - l
35 46
7 8x8
M. 4 4
% i. 54%
26>/ 44
9 8x12
30
4 4
i .A 55'/. 32'/*
44
9 8x12
35
4 4 1 1
59'/35 46
D--Smoke Outlet Height, End.................... In. E Smoke Outlet Height. Top................. .......in.
--Water Heater Connection from Floor..In.
G--Floor to Furnace Door Opening............in. Clear Opening in Base. Front........................ In. Clear Opening in Base, Rear...........................in.
42'A 49
32%
44'/, 51
34%
20 20%
10x15/2 ,10x15'/2 8x10'- 8x 10'/2 j
43% 42*/,
_
10%x15
--
42'A 48
44'A
20 10x15'/, 8x10'/,
44'/? 50
46'/,
20% 10x15Vz 8x10'/*
Outside Surface to Cover. Unjacketed, sq. ft. Shipping Weight. Unjacketed.... ..................lbs.
33 1040
40 1280 1
24 800
33 40 920 1130
The Kewanee Round Type *'R Steel
Heater and Boiler conform to the Con
struction Code of A. S. M. E. for low pressure heating boilers. Rated capacity of the Boiler is in accordance with thi* Steel Heating Boiler Institute Code.
For Oil and Gas only.
EQUIPMENT for Heater or Boiler--Burning Coal: Base assembled with ash door and rear pouch with primary draft damper: heavy
rocking grates, each bar removable: shaker arm. handle. Fire and flue cleanout doors with frames. 2-Way smokehood assembled with
check and choke dampers; cleanout cover plates: l*-in. washout plugs. And for Boiler, hot water coil.
--For Oil. Gas or Stoker: Base assembled; flue doors with frame; integral furnace door-frame is removable, has inspection shutter with
pyrex window. Self-controlling draft adjuster, spinner blades, and cleanout cover plates;
washout plugs.
And for Boiler, hot water coil.
TRIMMINGS for Steam Boiler--Burning Coal: Steam gauge; water gauge glass, chromium trimmings, two compression gauge cocks; safety valve. Arco damper regulator, weight, rod and lever.
. . . for Water Boiler--Burning Coal: Combination altitude gauge and Thermometer; Arco damper regulator, weight, rod and lever.
. . . for Steam Boilei--Oil, Gas or Stoker: Steam gauge; water gauge glass, chromium trimmings, two compression gauge cocks; safety valve. The extra 1%-in. tapping in top of Boiler may be used for oil burner control.
. . . for Water Boiler--Oil, Gas or Stoker: Combination altitude gauge and Thermometer.
The only Trimming furnished for Water Heaters is Damper Regulator Rod. TOOLS for Heater or Boiler--Burning Coal: Poker. Soot Scraper and Flue Brush.
--For OH. Gas or Stoker: Flue Brush only.
TYPICAL PIPING CONNECTING VERTICAL OR HORIZONTAL TANK TO HOT WATER COIL ON ROUND "R" BOILER
KEWANEE ROUND "R" STEEL
HEATING BOILER WITH
KEWANEE COPPER COIL.
FOR HOT WATER HEATING COIL SPECIFICATIONS
AND PRICES
SEE PAGE 2.
7 >
J^tWAJN&t Indirect Hot Water Heating Coils jn Square "R" Boilers
Type "R" Boiler ratings do not include allowance for" heatihg^pln^a^
Coils.! With STOR AGE
TANK operation, allow sq. ft. steam radiation for each gallon capacity of Coil. For INSTANTANEOUS, flow,
allow 4 sq. ft. per gal. if hot water demand is added to the heating.load for more.,than 10 minutes in any hour. '
TABLE OF COIL PHICES AND MAXIMUM SIZE WHICH CAN BE INSTALLED.
f , -j;'
j For STORAGE TANK Operation
Bolter j No.
Coll No.
and
Size
i* ._ -
RATED CAPACITY Gallon* Heated
In Boiler Water
212*F 180*F
1' Surface Sq: Ft.
Number of Trade
Baths or ' Apartments
Price ' Installed
1 S6i24 S8-24
1 D6-24
j D8-24 I ! S6-30
S8-30
D6-30 ; D8-30
| 742
1
S6-36 S8-36 D6-36 D8-36
S6-42 743 S8-42 745 D6-42
D8-42
746
` ,
|
S6-48 S8-48 D6-48 D8-48
S6-54
747
|
j
S8-54 D6-54
! . D8-54
S6-60 S8-60 748 D6-60 D8-60
!3R1
SL6-24 SL8-24 DL6-24 DL8-24
1
i3R2* : | |
SL6-30 SL8-30 DL6*30 DL8-30
1
:3R3
1 1
SL6-36 SL8-36
DL6-36 DL8-36
i SL.6-42 3R4 i SL8-42 3R6 ' DL6-42
i ; DL8-42
1
3R7
SL6-48 SL8-48 DL6-48 DL.8-48
3R8
| 1
|
SL6-54 SL8-54 DL6-54 DL8-54
3R9 l.
,
ii
SL6-60 SL8-60 DL6-60 DL8-60
90 120 180 240
120 160 240 320
150 200 300 400
180 240 360 480
210 280 420 560
240 320 480 640
270 360 540 , 720 1
90 120 180 240
120 160 240 320
160 200 300 400
180 240 360 480
210 280 420 560
240 320 480 640
270 360 540 720
55 70 110 145
70 , 95 145 ! 190
90 120 180 240
110 145 215 290
125 170 250 335
145 190 290 385
160 . 215 325 , 430 ;
55 1 70 110 145
70 95 145 190
90 120 180 240
110 145 215 290
125 170 250 335
145 190 290 385
160 215 325 430
3.0 3.9 6.0 7.7
3.8 ! 5.0 I 7.6 1 9.9
; 4.6 6.0
91 11.9
5.4 j 7.0 10.7 14.0
6.2 i 8.1 12.3 16.1
6.9 9.1 13.9 18.2
7.7 10.2 15.4 2i 0.3
:i3.0 13.9. 6.0 7.7
3.8 5.0 7.6 9.9
14.6 6.0
i 9.1 11.9
5.4 j 7.0 10.7 14.0
16.2 8.1 12.3 1.6.1
6.9 9.1 13.9 18.2
7.7 10.2 15.4 20.3
1-3 4 6 8
4 5- 6
8 8-11
5 6- 7 10 11-14
6 8 12 16
7 9-10 14 16-19
8 10-11
16 19-21
9 12 18 24
1-3 4 6 8
4 5-6
8 8-11
5 6-7 10 11-14
6 8 12 16
7 9-10
14 16-19
S 10-11
16 19-21
9 12 18 24
. 823.80 27.40 34.60 41.80
27.40 32.20 41.80 50.60
31.00 37.00 49.00 57.00
34.60. 41.80 1 . 53.80 . 63.40
38.20 46.60 58.60 69.80
41.80 SO.gft
63.40 t 76.20
45.40 53.80 ' 68.20 82.60
$23.80 27.40 34.60 41.80
27.40 32.20 41.80 50.60
31.00 37.00 49.00 57.00
34.60 ; 41.80 -
53.80 t : 63.40
,, 38.20 46.60 58.60 69.80
41.80 50.60 63.40 76.20
45.40 53.80 68.20 82.60
>.J <r'` : !,r v'
Coll N1o. ' ;> ' '
DN1 - >
DN2
'-i. DN3
DN4,
DN7 ..j t
DN8
DN9
TN-1 QN-1
TN-2 QNr2
TN-3 QN-3.
*
TN-4 'l QNr4
: '1 : ' '
TN-7 i. QN.-7
TN-8 QN-8
' r"' "
TN-9 : i QN-9 J
For INSTANtANEOUS Flow
RATED CAPACITY
. Gallons .Heated -nr in
Boiler Water
,
! Number of Surface ! Baths or'. . Sq. Ft. -"'Apart-:-
In 1 Hr. in 1 Min.
| ments ,
v' .. ^
Trade ! ? Price Installed
185
'1 * 240
.r,
. 3.1 v *"r . -
. 4.0 - / . ,
'
12.3
i $54.60
;,U .-r - ** 1 ' r- -J
!n " 15.9
*+ ", 63.40
,r 1, / 'a "\ . i i > 41
295 4.9 .19.5
12 ( 1 : 72.20
! ' : I- i. , /, ,
.350
5.8
,'
23-7 f 18
8i.oo;
/ j. <* ^ Vw
400 6.7 ... 26.7 ,>1,23": 89.00
,' h
., j `; s.
- : *v
450 7.5 30.3
28 !
97.00
510
185 240
...
,
8.5
-j !
339
"V" "
3.1 .12.4 4 0 15l9
34 ` 106.60 :
l` t,l, .':
-6`S :
1 ' ' .
$54.60 63.40
240 ' 4.0 .. 15.8 ' 310 'vI;l'5.2.*:1 20.5
6 12 .
63.40 74.60
A
290 375
350 445
4.8 ,6.3 ;
5.8 7.4'.. 1
19.2 25.0
.
22.7 29.6
lT2 i 20
.1 }` ,
f
: 71.40
, 85.00
!
18 28
``4
`.
'1
'
.. . -
; 81.00 96.20
390 510.
' -A _ .
'y
6.5 , 815
f.
26.1 34.2
' ` i-
.i
23 , 34
*.' "a
|
. ' 87.40 .106.60
445 580
'/ * '
7.4 " 9.7
29.6 38.8
* ; v - '
? 28 .. ,46
? ! -
.`
96^0 117.80
, .**
.495 , -. 8.3
'650 -
10.8
v>
33.0 43.4
; $,
34 ' .48 : :
, - ;" i
104.20 '129.00
0--300 gal. 13 + .1I gat. Oyer 300 gal. 23+.08 gal. ' Coils snorter than the maximum lengths listed above may be siituted in each boiler where less hot water capacity Is required. I> are interchangeable in boilers of same Series only.
Additions for Extras--
Only When Furnished With Type "R" Boilers
using these prices do not make any deductions for narts ueuallv furnished as regular eouinment.
-V,' . Boilers Number:
Vapor Damper Regulator Sleeves, ` per' Inch' Tapped Openings, per Inch Observation Doors Garbage, Incinerator, Front.
.v". ;*;; l ;V 2BTf*l6 gal.
734-735-736 . 742
83R14 83R2 83R3 *
743 - 745 - 746 747 - 748
83R4-83R6 83R7-83R8-33R9
$20.00 1.25 1.25 6.00
i| 1 1 -v
i,
$20.00, 1^5 1.25 6.00'
40.00.
.
Q<
<
/(