Document 2yq5R8XQRB1ZN21eM7BoZbMN
Cardinal
k
is,
?.
X
DO A 122803 CONFTDFNTTAl
*****************************************************************
100 AREA BI-WEEKLY CHECKLIST
*****************************************************************
1. TEST LEVEL ALARMS ON UNIT-100 HIGH, MEDIUM, AND LOW PRESSURE BOILERS AND DEAERATOR.
2. TEST AUTO OPERATION OF UNIT-100 DC SEAL OIL PUMP.
3. TEST UNIT-100 GENERATOR LIQUID LEVEL ALARM.
4. TEST UNIT-100 STAND-BY VOLTAGE REGULATOR. (6 MONTHS)
5. TEST UNIT-100 GAS CONSOLE EXPLOSIMETER ALARM.
6. TEST ANNUNCIATOR ALARM PANELS FOR UNIT-100 TURBINE, GENERATOR AND 1000 COOLING TOWER
7. TEST FLAME DETECTOR ON UNIT-100 HOT END BEARING.
R. TEST UNIT-100 HYDROGEN CONTROL CABINET EXPLOSIMETER ALARM.
9. TEST AUTO OPERATION AND ALARMS ON UNIT-100 DC COOLING OIL PUMP, JACKING OIL PUMP, AND AUXILIARY LUBE OIL PUMP.
10. TEST EMERGENCY LIGHTS - BUILDINGS 3703 & 3704.
11. CHECK 0CB-100 AIR COMPRESSOR OPERATION.
12. CHECK UNIT-100 INVERTER. (S/S APPROVAL)
13. OPERATE GEN-100 NEUTRAL SWITCH.
14. PERFORM HYDROGEN LEAK TEST ON GEN-100.
15. SPRINKLER SUPERVISORY AIR SUPPLY PRKSKURK (10 OZ. MIN.)
07..
16. POSITION OF BLOCK VALVE TO THE SPRINKLER SYSTEM VALVE BOX.
17. SWAP CONDENSATE PUMPS 1220 A / B / C ON OR NEAR FIRST OF EACH MONTH.
ia. FLUSH EACH CONDUCTIVITY LINES ON THE CONDENSATE SYSTEM.
19. OPERATE MOV 1250 AND CV 1250 MONTHLY.
DO A 122804 CONFTDFNTIAl
DATE- MO/DA/YR.
SHIFT SUPERVISOR
*****************************************************************
200 AREA BI-WEEKLY CHECKLIST
*****************************************************************
1. TEST LEVEL ALARMS ON UNIT-200 HIGH, MEDIUM, AND LOW PRESSURE BOILERS AND DEAERATOR.
2. TEST AUTO OPERATION OF UNIT-200 DC SEAL OIL PUMP.
3. TEST UNIT-200 GENERATOR LIQUID LEVEL ALARM.
4. TEST UNIT-200 STAND-BY VOLTAGE REGULATOR. (6 MONTHS)
5. TEST UNIT-200 GAS CONSOLE EXPLOSIMETER ALARM.
6. TEST ANNUNCIATOR ALARM PANELS FOR UNIT-200 TURBINE, GENERATOR AND 900 COOLING TOWER
7. TEST FLAME DETECTOR ON UNIT-200 HOT END BEARING.
8. TEST UNIT-200 HYDROGEN CONTROL CABINET EXPLOSIMETER ALARM.
9. TEST AUTO OPERATION AND ALARMS ON UNIT-200 DC COOLING OIL PUMP, JACKING OIL PUMP, AND AUXILIARY LUBE OIL PUMP.
10. TEST EMERGENCY LIGHTS - BUILDING 3706 AND OUTSIDE.
11. CHECK 0CB-200 AIR COMPRESSOR OPERATION.
12. CHECK UNIT-200 INVERTER. (S/S APPROVAL)
13. OPERATE GEN-200 NEUTRAL SWITCH.
14. CHECK UNIT-200 CARDLOK.
15. PERFORM HYDROGEN LEAK TEST ON GEN-200.
16. SPRINKLER SUPERVISORY AIR SUPPLY PRESSURE02. (10 OZ. MIN.)
17. POSITION OF BLOCK VALVE TO THE SPRINKLER SYSTEM VALVE BOX.
18. SWAP CT PUMPS 1000 A/B ON OR NEAR FIRST OF EACH MONTH.
19. FLUSH PROCESS WATER BACK-UP UNTIL CLEAR.
20. TEST BUILDING 3709 EMERGENCY LIGHTS.
DO A 122805 CONFIDENTIAL
DATE- MO/DA/YR.
SHIFT SUPERVISOR
**********************************************************************
300 AREA
BI-WEEKLY CHECKLIST
************************************************4^*******************
1- TEST LEVEL ALARMS ON UNIT-300, HIGH, MEDIUM, AND LOW PRESSURE BOILERS.
2. TEST OPERATION OF UNIT-300 DC SEAL OIL PUMP.
3. TEST UNIT-300 GENERATOR LIQUID LEVEL ALARM.
4. TEST UNIT-300 TURBINE HOUSE EXPLOSIMETER ALARMS.
5. TEST UNIT-300 HYDROGEN CONTROL CABINET EXPLOSIMETER ALARM.
6. TEST ANNUNCIATOR ALARM PANELS FOR UNIT-300 TURBINE, GENERATOR, AND BOILER.
7. TEST UNIT-300 ELECTRICAL ALARM PANEL AND SYNCH BUS ALARM PANEL.
8. TEST OPERATION OF UNIT-300 DC LUBE OIL PUMP.
9. TEST AUTO OPERATION OF AND SWITCH UNIT-300 LUBE OIL PUMPS.
10. TEST EMERGENCY LIGHTS - BUILDING 3707 - 300 ELECTRICAL PACKAGE - 300 MECHANICAL PACKAGE.
11. TEST OPERATION OF ALL MOTOR OPERATED VALVES ON UNIT-300 BOILER FEEDWATER SYSTEM.
12. PERFORM HYDROGEN LEAK TEST ON GENERATOR 300.
13. TEST FLAME DETECTOR ON UNIT-300 HOT END BEARING.
14. CHECK MECHANICAL PACKAGE AIR FILTER; CHANGE IF NEEDED.
15. SWAP EVAPORATIVE COOLER PUMPS.
(DATE- MO/DA/YR)
SHIFT SUPERVISOR'S SIGNATURE
00 A 122806 CONFIDENTIAL
*********************************************************************
400 AREA BI-WEEKLY CHECKLIST
*********************************************************************
1. TEST LEVEL ALARMS ON UNIT-400, HIGH, MEDIUM, AND LOW PRESSURE BOILERS.
2. TEST OPERATION OF UNIT-400 DC SEAL OIL PUMP.
3. TEST UNIT-400 GENERATOR LIQUID LEVEL ALARM.
4. TEST UNIT-400 TURBINE HOUSE EXPLOSIMETER ALARMS.
5. TEST UNIT-400 HYDROGEN CONTROL CABINET EXPLOSIMETER ALARM.
6. TEST ANNUNCIATOR ALARM PANELS FOR UNIT-400 TURBINE, GENERATOR, AND BOILER.
7. TEST UNIT-400 ELECTRICAL ALARM PANEL AND SYNCH BUS ALARM PANEL.
8. TEST OPERATION OF UNIT-400 DC LUBE OIL PUMP.
9. TEST AUTO OPERATION OF AND SWITCH UNIT-400 LUBE OIL PUMPS.
10. TEST EMERGENCY LIGHTS - BUILDING 3708 - 400 ELECTRICAL PACKAGE - 400 MECHANICAL PACKAGE.
11. TEST OPERATION OF ALL MOTOR OPERATED VALVES IN UNIT-400 BOILER FEEDWATER SYSTEM.
12. PERFORM HYDROGEN LEAK TEST ON GENERATOR 400.
13. TEST FLAME DETECTOR ON UNIT-400 HOT END BEARING.
14. SWAP E-H PUMPS.
15. CHECK MECHANICAL PACKAGE AIR FILTERS; CHANGE IF NEEDED.
16. SWAP EVAPORATIVE COOLER PUMPS.
(DATE- MO/DA/YR)
SHIFT SUPERVISOR'S SIGNATURE
DO A 1.72807 COIsIFTDFNT T At.