Document 2xN3wJqrJR85zyVr6p9gNx5r
*/
f.
*
'1*y .
* . *i*
__ (i
/ ' A
'.
*
/ j * fc hf
Uy.<!>
*Jj\
VV&stln0u. housc Electric CorpemUon
January 14, 1572
Bov )41 Bloamhptrca, Ini- 47*
1 *Dr. A. Pozefsky, Chairman j ' C-107 Capacitor Working Group .v>v General E le c tric Company
Engineering Department . * * Hudson Fai Is I New York .12339 .
.--V
>
,,,4 *
A ^:C r.D ear:Dr. Pozefsky:. A>1*S :` vA../-v..:
v:'--; * >' .
V: Y? .: *: `
* : : Attached 1s a copy o f my`f i r s t d ra ft o f th e "Capacitor Plant House-
keeping and Employee Safety" portion o f the proposed ANSI C-107 standard
H v / ^ 'o n . the use and disposal of PCB's. . ?
.. ..
4*'
.. t v
* / .
>.
' . . . ' ' . . * .* *
` r \- .
v"; In order to expedite consideration o f the various p arts o f the proi posed standard a t the next meeting o f the working group a t the H arlott ';7 ' Hotel in Chicaqo on February 8 and 9, I am also sending a copy to each
of the attached l i s t of addressees.
.
; .v
\
*. ,, .;v *
1:
>
i.y
* **.t ' " ,,V-
*,,
`-
i.`/#*
.***.
? .
7
/
( ;. V .
; Robert D. McClain, Manager . . .' Capacitor Unit.Engineering ; .
' 7 v -* RDMcC:kb ' Attacks.
*
**.. ' .... : - 5, '
.
' ......
I ..
? r v . uv
PLAINTJFF'S
EXHIBIT
SBRN003U70 906217
N. R. Clark Universal Manufacturing Company 902 Crescent Avenue Bridgeport, Connecticut 06607
J. F. Kuzela Engineering Manager . Power Capacitors Sangamo E lectric Company P. 0. Box 359 S pringfield, I llin o is 62705
*
Dr. E. M. Moore 2427 St. Vincent Avenue LaSalle, I llin o is 61301
W. P. Papageorge, Manager Environmental Control Monsanto Company 800 North Lindberg Blvd. S t. Louis, Missouri 63166
P. G. Benignus
Marketing Manager D ielectric Fluids Monsanto Company
800 North Lindberg Blvd. S t. Louis, Missouri 63166
E. G. Hammer McGraw Edison-Power Systems Division
P. 0. Box 1 6 0 . South Milwaukee, Wisconsin 53172
F. R. Lengefeld
E lectrical Engineering Department Code 450
Union E lectric Company
'
f P. 0. Box 149 '
S t. Louis, Missouri 63166
"
, Dr. T. K. SI oat
' Fluid Insulation Section
Transformer Division
Westinghouse E le c tric Corporation .
Sharon, Pennsylvania
;
Ann.riAM. Salazar
..
:
155 East 44th S tre e t
'
New York, .New York 10017' .
'.
. 4
* **? *
'
, ; ;
. . . . .
GBRN003M71 906218
. . "ANSI C-107 1st Draft Proposal fo r February 0 , 1972" CAPACITOR PLANT HOUSEKEEPING AND EMPLOYEE SAFETY
The following procedures and lim its are Intended to be minimum require-
ments to be met by manufacturers o f capacitors using polychlorinated biphenyl.
Handling, control and disposal procedures are given, together with exposure
:11m1ts and Indicated antidotes and cleanup procedures.
.'
1. . M aterlal. Chlorinated biphenyl for use In capacitors sh all consist o f
chlorinated homologues and Isomers o f biphenyl not exceeding the"tabulated values:
Pentachloro (and higher 1 chlorine) Tetrachloro
Trlchloro ( and lower 2 chlorine)
.403 15.003
(Balance)
Solvents Include benzene, kerosene, acetone, amyl alcohol, e th e r, and chloro
form. Other typical p roperties are:
Flash p o in t, Cleveland open cup: 177C, minimum
D istilla tio n Range: 10% below 323eC; 90S below 356C
Specific Gravity: 1.362 to 1.372, a t 25*C/15.5C
Vapor Pressure
0C * 0.001 rrcn 25C * 0.006 mm ( e s t.) 150C 4.3 mm 200C = 29.0 inn
i At 25C and 760 mm Hg pressure, Saturated a i r contains O.
1 m q/l1ter * 98.8 ppm)
(l ppm
0.010 m g/l1ter)
m h/H ter.
2. Bulk flu id shipment, receiving, and tra n sfe r: Shipment o f polychlorlnate biphenyl from point of manufacture to point o f receiving sh a ll be done 1n closed containers: ra il tank c a rs; truck tanks; marine or barge tanks; o r sealed drums. Containers shall be lab elled as to contents, and carry a precautionary label again loss of fluid to the open environment. Containers used fo r transport of poly-
906219
BBRN003H72
2
chlorinated biphenyl shall not be used for storage or tran sp o rt of other material without being completely cleaned of a ll traces of PCB. (Cleaning procedures must
0
take cognizance o f precautions against excessive exposure and o f the need for pro* per disposal o f contaminated cleansing solvents and m aterials s e t forth below.) Transfer from shipping container to processing system sh all be through closed piping or tubing with appropriate valves, pumps, e tc . Provision shall be made fbr. trapping and disposing of flu id s lo s t by leakage or s p ills from the tra n sfe r system and from the storage containers.
Drums to be re tire d from use shall be cleaned before crushing, delivery to scrap dealers, or other dlposal. Contaminated cleaning flu id s and m aterials shall be disposed of as indicated below.
3. Handling during manufacturing operations: I t 1s generally accepted th a exposure to 'c a p a c ito r PCB is not hazardous, provided simple precautions are taken.
(a). Vapors. Maximum atmospheric concentration lim it (8 hours) recownended: one milligram of capacitor PCB per cubic meter o f a ir .
Breathing vapor or fume from heated PCB should be avoided. Provision of adequate v en tilatio n and regulation o f manufacturing operations to avoid open exposure of hot PCB (j5.*C, or higher) shall be made. The gases produced when askarel 1s decomposed by very high temperatures (such as th a t o f an e le c tric arc) 1n the presence o f a ir or organic Insulating m aterials contains a high percentage o f hydrogen chloride, and small percentages o f carbon dioxide, carbon monoxide, and oxygen. Minute concentrations of th is combination o f gases are very unpleasai and i r r i ta t in g , thus giving ample warning of th e ir presence. When necessary, under emergency conditions, to en ter a space containing a high concentration of PCB vapor or decomposition products, a hose mask with blower, or breathing equip ment with a self-contained a ir supply should be used. [(Gas mask,: a ir H-
906220
GBRN003U73
3
resp irato r, o r hose mask without blower nay be used i f there is no danger o f oxygen deficiency, (considered to be a breathing atmosphere o f a t le a s t 192 oxygen and not more than 25 PCB)]. I f the odor o f PCB 1s detected by the person wearing protective equipment, he should Immediately go Into fresh' a ir . All gas masks, resp irato rs and replacement parts sh all hive Bureau of Hines approval, and be maintained on a regular schedule In accordance with the manufacturers re commendation.
(b). Fluid. Unlike insulating o i l , there is v irtu a lly no fire hazard
in handling PCB. A lim ited solvent action (sim ilar to th a t for paint thinner)
on the fats and o ils o f the skin with prolonged contact may lead to drying and
chapping of the skin. As with Insulating o i l , some people are a lle rg ic to PCB
and continued exposure may re su lt 1n skin ir r i ta t io n . Both the liq u id and vapor
are moderately ir r ita tin g to eye tis s u e s .
Operating procedures should avoid contact with hot flu id s (about 55C).
Use of eye protection 1s recoirmended. The use of gloves 1s not recommended. Contaminated clothing must be changed and laundered. Use o f enclosed tra n sfe r and handling equipment, processing equipment and the use o f mechanical washers
CD
g rroo
reduces direct contact.
Medicinal washes or detergents followed by an application of cold cream
w ill eliminate any ir r ita tio n resu ltin g from askarel coming Into contact with
an open cut or abrasion. Eye exposure to liq u id PCB should be Irrig a te d immediate
with large q u an tities of running water from an approved eye wash source for f lf te i
minutes and then be examined by a physician. Persons developing a skin I rr ita tio r
or respiratory tr a c t ir r ita tio n apparently due to contact with PCB should be place
under the supervision of a physician. (A drop of casto r o il has b>en found to
neutralize any ir r ita tio n caused by contact of PCD with the eyes.) eBRN0 0 3H7
4
Ingestion or swallowing o f PCB's 1s not generally regarded as a problem
of the industry,. PCB's are regarded as being moderately to x ic i f taken in tern al!:
Swallowing several ounces could cause ir r ita tio n o f the*digestive tr a c t and in
ternal reactio n s, and should be referred to a physician.
_____
4. Manufacturing control of lo sse s; Manufacturing equipment and operating
procedures must safeguard against excessive loss of PCB to the environment througt
close control and disposal procedures.
Enclosed systems o f sealed piping, properly gasketed jo in ts , valves, con
ta in e rs , and processing chambers are to be used fo r any portion of the operation
where PCB temperatures may exceedS > C , Enclosure sh all preferably extend to
all other portions of the system insofar as practicable.
Drains"shall be plugged and curbs in sta lle d around a ll "open" portions
of the PCB processing area, to assure against inadvertent loss to sewer systems
by sp illa g e , leakage, or other uncontrolled lo ss.
V entilation of the area and exhaust of pump and systems gases shall be
directed through f i l t e r entrapment capable of restrain in g vapor losses to the
atmosphere o f . _ m g /lite r, peak and
kg per day.
S p ills of PCB shall be removed promptly by use o f absorptive m aterial, pre
ferably sawdust, or trapped and removed by pumping, o r by other su itab le means.
Waste fluids containing PCB and not su ita b le fo r reconditioning or reuse
shall be collected (by means o f tra p s , drip pans, tr a y s , e tc .) from the various
parts of the manufacturing and processing area (including washers or other clean
ing devices).
Wiper rags, clothing and other extraneous m aterials saturated with PCB's
shall be collected within the curbed area.
906222
BBRN003M75
s 5
5. Disposal of PCB w astes: Methods fo r disposal of liq u ids and saturated
soltds generated by the manufacturing operation shall be 1n accordance with those
outlined 1n subsquent portions o f th is standard and sh all Include (but not
be lim ited to ) the following:
A) Liquid PCB contaminated by a lip h a tic m aterials and other sub-
stances such as to make i t unsuitable fo r reclaiming as a d ie le c tric flu id .
Liquid PCB from solvent operations or w ater/detergent type washers. Saturated earth or other absorbent media from f ilte r in g operations. Saturated sawdust o r other absorptive m aterial from s p ills . E) Saturated f i l t e r s from vapor control devices and other f i l t e r s . Fj Saturated wastes (paper, rags, e tc .) ^ G) Saturated, spent gasket m aterials, v'' H) PCB contaminated vacuum pump o ils . I) PCB contaminated steam j e t vacuum pump condensates.
6. Miscellaneous Procedures: A) S p ills by leakage from sealed, finished capacitors should be clean
ed up promptly by use of absorbent sawdust, which should then be moved to con tain ers for th a t purpose within the curbed or drained area, and la te r disposed of properly.
B) PCB wastes should never be disposed o f, deliberately, down efflu en t drains or sewers. The utmost care must be excerised to prevent accidental loss by these means.
C) Capacitors fa ilin g t e s t or otherwise designated fo r disposal must be controlled and handled 1n accordance with the in te n t o f the procedures above, fin a lly being disposed of by one o f the means outlined below.
7. References:
A) Monsanto Company, Organic Chemicals Division: Tech. B ulletin #PL-306 Aroclor P lasticizers (December 1960).
B) American Conference of Governmental Industrial Hygienists:
Threshold Limit Values for 1964. AMA Arch. Environ. Health.
9 : 545 (1964).
6BRN0031176
906223
6
C) Treon, J . F . , F. P. Cleveland, J . Cappel, and R. W. Atchley: The Toxicity of the Vapors o f Aroclor 1242 and Aroclor 1254. Amer. Ind. Hyg. -Assoc. Quart. 17: 204 (1556}.
0) Elkins,. H. B.: The Chemistry o f Industrial Toxicology. John Wiley and Sons, In c ., New York (1959).
E) Drinker, C. K., M. F. Warren, and 6. A. Bennet: The Problem of Possible Systemic Effects from Certain Chlorinated Hydrocarbons. J . Ind. Hyg. Toxicol. 19: 283 (1937).'
F) Drinker, C. K.: Further Observations on the Possible Systemic Toxicity o f Certain o f th e Chlorinated Hydrocarbons. J . Ind. Hyg. Toxicol. 21: 155 (1939).
6) Greenburg, L ., M. R. Mayers, and A. R. Smith: The Systemic Effects Resulting from Exposure to Certain Chlorinated Hydrocarbons. J . Ind. Hyg. Toxicol. 21: 29 (1939).
H) Hygienic Guide Series "Chlorodiphenyls" by the American Industrial Hygiene Association, 14125 Prevost, D etro it, Michigan.
906224