Document 2qw5G7zyg130OVNgRnDZE2nrN

SHELL OIL COMPANY ENGINEERING STANDARDS MATERIAL AND EQUIPMENT STANDARD 5-2 INSULATION AUGUST 1959 ABS-061224 SHELL OIL COMPANY ENGINEERING STANDARDS INDEX MATERIAL AND EQUIPMENT STANDARD 5-2.1 GENERAL 5-2.1.1 Scope 5-2.1.2 Material Requirements INSULATION MAE STANDARD 5-2 AUGUST 1959 PAGE I OF 2 PAGE NO. 1 1 1 5-2.2 HOT SERVICE 5-2.2.1 Piping .1 Insulation and Coating Materials .2 Final Coverings ,.3 Bandings .4 Accessories 5-2.2.2 Vessels .1 Insulation and Coating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.2.3 Exchangers .1 Insulation and Coating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.2.4 Tanks.. ' .1 Insulation and Coating Materials .2 Final Coverings .3 Accessories 5-2.2.5 Pumps, Compressors and Turbines .1 Insulation and Coating Materials .2 Final Coverings 3 Accessories 6-2.3 COLD SERVICE - 5-2.3.1 Piping .1 Insulation and Coating Materials .2 Final Coverings . 3 Bandings .4 Accessories 1 1 1 1 2 2 2 2 2 3 3 3 3 4 -4 4 4 4 4 4 5 5 5 5 ABS-061225 5 5 5 6 6 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M & E STANDARD 5-2 AUGUST 1959 PAGE 2 OF 2 IHDEX (CONTINUED) MATERIAL AND EQUIPMENT STANDARD 5-2.3.2 Vessels .1 Insulation and Coating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.3.2 Exchangers .1 Insulation andCoating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.3.4 Pumps and Compressors .1 Insulation andCoating Materials .2 Final Coverings .3 Accessories PAGE HO. 6 6 7 7 7 7 7 7 8 8 8 8' 8 8 CHARTS APPENDED CHART HO. 1 - Hot Service Insulation and Coating Materials CHART HOi 2 - Cold Service Insulation-and:Coating.Materials . ' ABS-081226 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION MCE STANDARD 6-2 AUGUST 1969 PAGE I OF 8 5-2.1 GENERAL 5-2.1.I SCOPE This standard covers the selection of materials for the insulation of piping, vessels, exchangers, tanks, pumps, compressors, and turbines in hot and cold services. It is intended to establish a standard of quality applicable to all in sulating materials. 5-2.I.2 MATERIAL REQUIREMENTS I Reference to a particular material or equal shall serve only as a precise identification of the type and quality of the material required. Alternate materials will be considered. Sufficient engineering data for evaluation of alternate materials shall accompany proposals. Shell shall be the sole judge of the equality, design, workmanship, and suitability of materials offered on an alternate basis. 2 All aluminum sheets and elbows used for final covering in hot services shall have an asphalt, polyethylene, or equal, protective barrier factoryapplied to-the under side when used with insulations which are chemically _. reactive with aluminum.' 5-2.2 HOT SERVICE 6-2.2.I PIPING . . .1 INSULATION AND COATING MATERIALS . Insulations and'coatings shall be in accord with. appended' Chart' No. 1. .2 FINAL COVERINGS V \ V; . ' .1 Final covering for piping insulation inside office'buildings shall be 8-' ounce canvas saturated with Aroboi Mfg. Co. Arobol, or equal.. 2 Final covering for straight piping' insulation inside,, unit areas shall be flat aluminum) sheets, 0.016 inch, utility grade, half hard)- mill finished, in cut and. machine rolled sections approximately 3 feet long. Pinal covering for welded elbow insulation inside unit areas shall be preformed aluminum elbows, Childers Mfg. Co', General Aluminum Supply Co., or equal. . 3 Final covering for straight, piping insulation outside unit areas. shall be asbestos-asphalt felt in cut and rolled sections approximately 3 feet ' long, Johns-Manville Corp., Double-Coated Flexstone,'or equal. Final covering for welded elbow insulation outside unit areas shall be veatherproofing compound, Philip Carey Mfg. Co. Thermotex B, or equal. ABS-061227 INSULATION MAE STANDARD 5-2 AUGUST 1959 PAGE 2 OF B SHELL OIL COMPANY ENGINEERING STANDARDS .3 BAND I NOS I Banding shall not be applied on one-piece pipe insulation. 2 Banding on insulation under aluminum final covering shall be: I Piping 10 inches and smaller - 0.051 inch diameter, soft, type 18-8, stainless steel wire; 2 Piping 12 inches through l6 inches - 0.064 inch diameter, soft, type 18-8, stainless steel wire; . 3 Piping 18 inches and larger - 1/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands and seals. 3 Banding on insulation under asbestos-asphalt felt final covering and on asbestos-asphalt felt final covering shall be: I Piping 10 inches and smaller - 0.064 inch diameter, galvanized, soft, iron wire; 2 Piping 12 inches through 16 inches - 0.083 inch diameter, galvanized,' -- soft, iron wire; *3 Piping 18 inches and larger - l/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. 1 Banding on aluminum final covering shall be l/2 inch x 0.020 inch, soft aluminum bands and aluminum seals. .4 ACCESSORIES .1 Glass fabric shall be Twinsburg - Miller Co. Glasfab, 20 x 20 mesh> asphalt treated,- or equal. . ' /. 2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.2.2 VESSELS .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 1. .2 FINAL COVERINGS .I Final covering for vertical vessel shell insulation shall be corrugated aluminum roofing sheets, 1-1/4 inches x 1/4 inch corrugations, 0.019 inch, standard grade, half hard, mill finished. ABS-061228 i SHELL OIL COMPANY ENGINEERIN6 STANDARDS INSULATION M S E STANDARD 5-2 AUGUST 1959 PAGE 3 OF 8 .2 Final covering for horizontal vessel shell insulation shall be flat alu minum sheets,- 0.020 inch, utility grade, half hard, mill finished. .3 Final covering for vessel head insulation shall be weatherproofing com pound, Philip Carey Mfg. Co. Thermotex B, or equal.. .3 BANDINGS .I Banding on vessel shell insulation shall be: .1 Vessels 8 feet O.D. and smaller - 1/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands. .2 Vessels larger than 8 feet O.D. - 3/t inch x 0i020 inch, soft, type 18-8, stainless steel bands with A. J. Gerrard and Co. Expand-R-Strap, Techalloy Co. Breather Spring, or equal, expansion sections and stain less steel seals. .2 Banding on vessel head insulation shall be 1/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands anchored with lacing,wire hair pins to -- l/2 inch nut blanks welded to heads. 3 Banding on vessel shell final covering shall be: I Vessels 8 feet O.D. and smaller - 3/t inch x 0.025 inch, soft, alu minum bands with- aluminum seals. ,. 2 Vessels larger than 8 feet O.D., - J>/h inch x 0.020 inch,, soft, type 18-8, stainless steel bands with A. J. Gerrard and Co. Expand.-R-Strap, Techalloy Co. Breather Spring, or equal, expansion sections and'stain- ' - less steel seals. . .4 ACCESSORIES I Wire mesh shall be 1 inch hex mesh of O.Q32.inch diameter,: 3 twist,' soft,, type l8-8, stainless steel wire. . :: 2 Lacing wire shall be 0.051 inch diameter, soft/ type 18-8, stainless steel wire. 5-2.2.3 EXCHANGERS .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended "Chart No. 1. ABS-061229 IHSULATI OH M & E STANDARD 6-2 AUGUST I 959 PAGE I OF 8 SHELL OIL COMPANY ENG INEERI NO STANDARDS .2 FINAL COVERINGS I Final covering for exchanger shell and channel insulation shall be flat aluminum sheets, 0.020 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. .2 Final covering for exchanger shell head and channel head insulation shall be weatherproofing compound, Philip Carey Mfg. Co. Thermotex B, or equal. .3 BANDINGS I Banding on exchanger shell and channel insulation shall be l/2 inch x 0.015 inch, soft, type l8-8, stainless steel bands with stainless steel seals. . .2 Banding on exchanger shell and channel final covering shall be 3/4 inch, x 0.025 inch, soft, aluminum bands with aluminum seals. .4 ACCESSORIES . I Wire mesh shall be 1 inch hex mesh of 0.032 inch diameter, 3 twist, soft, type 18-8, stainless steel wire. .2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 6-2.2.1 TANKS .) INSULATION AND COATINGS MATERIALS ; Insulations and coatings shall be in accord with the appended Chart No. 1. .2 FINAL COVERINGS AND BANDING . I Tanks 12 feet O.D. and smaller.- Final covering and banding for tank in sulation shall be in accord with section 5-2.2.2 for hot service vessels. .2 Tanks larger than 12 feet O.D. - Final covering for tank insulation shall be flat asbestos-cement sheets, 4 feet x 8 feet x 3/16 inch thick, Johns- Manvilie Corp. Asbestocite, or equal. .3 ACCESSORIES . I Tanks 12 feet O.D. and smaller - Accessories shall be in accord with section 5-2.2.2. for hot service vessels. ABS-061230 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION MAE STANDARD 5-2 AUGUST 1959 PAGE 5 OF 8 .2 Tanks larger than 12 feet O.D. - Accessories shall be In accord with appended drawing No. B-1235. 5-2.2.& PUMPS, COMPRESSORS AND TURBINES .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be In accord with appended Chart No. 1. .2 FINAL COVERINGS Final covering for insulation shall be weatherproofing compound, Philip Carey Mfg. Co. Thermotex B, or equal. .3 ACCESSORIES .1 Wire mesh shall be 1 inch hex mesh of 0.032 inch diameter, 3 twist, soft, type 18-8, stainless steel wire. ` .2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.3 COLD SERVICE 5-2.3.1: PIPING ,I INSULATION AND COATING MATERIALS . , Insulation and coatings shall, be in accord with appended Chart No. 2. . ' .2/: FINAL COVERINGS : .| Final coverings for piping insulation inside office buildings shall be 8-ounce canvas saturated with Arobol Mfg. Co. Arobol, or equal.' 2 Final covering for straight piping insulation inside unit areas shall be flat aluminum sheets, 0.016 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. .3 Final covering for straight piping insulation outside Qnit areas shall be asbestos-asphalt felt in cut and rolled sections approximately 3 feet -long, Johns-Manville Corp. Double Coated Flexstone, or equal. .4 Final covering for welded elbow insulation inside unit areas shall bepre' formed aluminum elbows, Childers Mfg. Co., General Aluminum Supply Co., or equal. ABS-061231 INSULATION MAE STANDARD 5-2 AUGUST 1959 PAGE 6 OF 8 SHELL OIL COMPANY ENGINEERING STANDARDS .5 Final covering for welded elbows outside unit areas shall be weather proofing compound, Pittsburgh Corning Corp. Pittcote 300, or equal. . .3 BANDINGS . . I Banding on insulation under aluminum final covering shall be: .1 Piping 10 inches and smaller - 0.051 inch diameter, soft, type 18-8, stainless steel wire; .2 Piping 12 inches through l6 inches - 0.064 inch diameter, soft, type 16-8, stainless steel wire. .3 Piping 18 inches and larger - 1/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands with stainless steel seals. . 2 Banding on insulation under asbestos -asphalt felt final covering and on asbestos-asphalt felt final covering shall be: .1 Piping 10 inches and smaller - 0.064 inch diameter, galvanized, soft, iron wire; 2 Piping 12 inches through l6 inches - O.O83 inch diameter, galvanized, soft, iron wire. 3 Piping 18 inches and larger - 1/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. 3 Banding on aluminum final covering shall be l/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. ' .4 ACCESSORIES . . I Glass fabric shall be TwLnsburg-Miller Co. Glasfab, 20 x 20 mesh, asphalt treated, or equal. 2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.3.2 VESSELS ,| INSULATION AND COATING MATERIALS - Insulations and coatings shall be in accord with appended Chart Ho. 2. ABS-061232 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION MAE STANDARD 5-2 AUGUST 1959 PAGE 7 OF 8 2. FINAL COVERINGS I Final covering for vertical vessel shell insolation shall be corrugated aluminum roofing sheets, 1-1/4 inches x l/4 inch corrugations, 0,019 inch, standard grade, half hard, mill finished. 2 Final covering for horizontal vessel shell insulation shall be flat al uminum sheets, 0.020 inch, utility grade, half hard, mill finished. .3 Final covering for vessel head insulation shall be weatherproofing com pound, Pittsburgh Corning Corp. Pittcote 300, or equal. .3 BANDINGS .1 Banding on vessel shell insulation shall be: .1 Vessels 8 feet O.D. and smaller - 1/2 x 0.015 inch, soft, type 18-8, stainless steel bands with stainless steel seals; .2 Vessels larger than 8 feet O.D. - 3/4 inch x 0.020 inch, soft, type 18-8, stainless steel bands with stainless steel seals. .2 Banding on vessel head insulation shall be l/2 inch x 0.015 inch soft, type 18-8, stainless steel bands anchored with lacing wire hair pins to l/2 nut blanks welded to heads. .3 Banding on vessel shell final covering shall be 3/4 inch x 0.025 inch, soft, aluminum bands with aluminum Beals. .4 ACCESSORIES .. :. . /! .1 Glass fabric shall be 5*vinaburg-Miller Co. Glasfab, 20 x 20 mesh,. asphalt treated, or equal. . . " .. , ; :'v- - .2 Lacing wire shall be 0.051 inch diameter, soft,' .type 18-8, stainless ' . . steel wire. V.' 5-2.3.3 EXCHANGERS .1 INSUUATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 2. .2 FINAL COVERINGS .I Final covering for exchanger shell and channel insulation shall be flat aluminum sheets, 0.020 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. ABS-081233 insulation MAE STANDARD 5-2 AUGUST 1959 PAGE 8 OF 8 shell oil company ENGINEERING STANDARDS .2 Final covering for exchanger shell head and channel head insulation';' shall be weatherproofing compound, Pittsburgh Corning Corp. Pittcote 300, or equal. . .3 BANDINGS .f Banding on exchanger shell and channel insulation shall be l/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands with stainless steel sealB. . 2 Banding on exchanger shell and channel final covering shall be ~i/h inch x 0.025 inch, soft, aluminum bands with aluminum seals. .N ACCESSORIES .I' Glass fabric shall be Twinsburg-Miller Co. Glasfab 20 x 20 mesh, asphalt treated, or equal. . 5-2.3.1 PUMPS AND COMPRESSORS .1 INSULATION AND COATING MATERIALS Insulation and coatings shall be in accord with appended Chart Ho. 2. .2 FINAL COVERINGS Final covering for insulation shall be weatherproofing compound, Pittsburgh Coming Corp. Pittcote 300, or equal. .3 ACCESSORIES Glass fabric shall be Tvinsburg-Miller Co. Glasfab, 20 x 20 mesh, asphalt treated, or equal. - ABS-061234 1 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M & E STANDARD 5-2 AUGUST 1959 CHART NO. I ABS-06123 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M & E STANDARD 5-2 AUGUST 1959 CHART NO. 2 ABS-061236