Document 2qrbQJde4arQyzXmJ3Xn6eg2a
Inspection ID
Class I and II Well Inspection Form
US Environmental Protection Agency - Region 4 Underground Injection Control Program
61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424
Inspector(s):
Anthony Shelton Carol Chen
_ (lead), ,
EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1 - 1 8
EPA Permit # (or RA): Carl Weller
Page 1 Of 2 Start Time: 12:50 pm End Time: 12:59 pm
Facility Contact Information
Facility Name:
PETRO HARVESTER OPERATING COMPANY, LLC
Street Address: 1107 W 6th St (office address)
City:
Laurel
County:
Jones
Nature of Business: Oil and gas extraction industry
Facility Owner/Operator: PETRO HARVESTER OPERATING COMPANY, LLC
Email:
kerry.allen@rockallenergy.com
Facility Contact (if different): Kerry Allen, Sr. Operations Manager
O/O Mailing Address: 1107 W 6th St (office address)
City:
Laurel
County:
Jones
State: MS Zip: 39440 Phone: 601-651-2100 Phone: 601-651-2105
State: MS Zip: 39440
Well Data from File
Well Name & #: Well Type (see table): Latitude (N):
City of Laurel (COL) 6-3 #3
Produced Fluid Disposal, UIC Class II
31.69637
Longitude (W):
State Permit: API#2306720449-00-00
-89.14133
Elevation (ft): 281'(Gr)
Injection Method (check applicable): Casing Injector; X Tubing & Packer; Cemented Injection Tubing
PBDT CIBP 3,595, 10' cement Other:
Total Depth (ft): 4,616' Inner Casing Size (in): Inj. Zone: Open Hole; X Perforated; Top(ft) 3,247'
7" Tubing Size (in): 3 "
Packer Depth (ft): 3,202'
Bottom(ft): 3,536'
Max. Injection Pressure (psig): 746 psi
Latitude (N):
31.69636
Longitude (W):
-89.14133
Elevation (ft):
EPA GPS ID: SX8123 Well Status (see table): AC If not Active, Reported Date Last Active:
Nature of Injected Fluid(s) if any: Produced fluids
General Condition of the Well Site:
NA
Field Measurements and Observations
Notes & Comments (include discrepancies from database values): Tubing gauge reads: 425 psi, Annulus gauge reads: 425 psi
Perforations provided by field hand on-site: Team's observations:
3,247' to 3,265'
Well, City of Laurel 6-3 #3 was injecting at 425 PSI and we noticed that the
3,315' to 3,325'
Annulus was also at 425 PSI (which could show a Mechanical Failure), so
3,368' to 3,400'
we asked if the Annulus could be bleed off, to watch for a pressurization
3,523' to 3,536'
of the Annulus. The Annulus did not pressurize in the time we were at that location.
See reverse for additional observations, comments and photo log
Owner/Operator Representative (Optional)
UIC Inspector
Name: Signature:
Inspector Carl Weller's signature:
Name: Signature:
Anthony Shelton
ANTHONY SHELTON
Digitally signed by ANTHONY SHELTON Date: 2022.01.19 14:43:18 -05'00'
Version 2018-04-18
Digitally signed by CAROL
CAROL CHEN Date: 2022.01.19 13:36:44 CHEN
Inspector Carol Chen's signature:
-05'00'
Inspection ID
Field Measurements and Observations (Cont.)
Class I and II Well Inspection Form
US Environmental Protection Agency - Region 4 Underground Injection Control Program
61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424
(Cont) City of Laurel (COL) 6-3 #3
EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1 - 1 8
EPA Permit # (or RA): Page 2 Of 2
Team's comments on Petro Harvester's on-site operations: We Inspected 8 wells that day, with a total of 9 people. 4 from Petro Harvester, 2 from MSOGB and 3 EPA. All inspected wells were located in areas that were fenced and gated. All the Pumping Units and Injection Pumps were of high quality and operated almost silently. Locations seemed to be kept clean and organized.
(TA status: inactive 2 years or more. IN status: inactive less than 2 years. PBTD: Plug back total depth - not total well depth)
Photo Log
Photographer: Photo ID: Description: Photo ID: Description:
Carl Weller
EPA Camera ID:
111
Time: 12:58 pm Lat (N):
31.69636
At the well site, the annulus gauge reads 425 psi.
112
Time: 12:59 pm Lat (N):
31.69635
The tubing gauge reads 425 psi showing injection pressure.
SX8123
Long (W)
-89.14124
Altitude 121
Long (W)
-89.14127
Altitude 121
Photo ID:
Time:
Lat (N):
Long (W)
Description:
Photo ID:
Time:
Lat (N):
Long (W)
Description:
Photo ID:
Time:
Lat (N):
Long (W)
Description: Photo ID:
Time:
Lat (N):
Long (W)
Description:
Owner/Operator Representative (Optional)
UIC Inspector
Name: Signature:
Inspector Carl Weller's signature:
Name: Signature:
Anthony Shelton
ANTHONY SHELTON
Digitally signed by ANTHONY SHELTON Date: 2022.01.19 14:43:44 -05'00'
Version 2018-04-18
Inspector Carol Chen's signature:
Digitally signed by CAROL
CAROL CHEN Date: 2022.01.19 13:37:23 CHEN
-05'00'