Document 2qp8RaNNwbYr4YgpqOV30av87

840 CHAPTER 37 i l9S3.,Guide sion.- 'Table 5 shows the tonnage capacity nonnally allowed'!or 'Freon1!2 liquid lines per foot equivalent length of pipe, ahd- Table 6 ..the mavimnm tonnage for suction and discharge Freon-12 lines. Table 7 presents suction-line capacity factors for equal pressure drop. i : i ACCESSORIES Dehydrators, oil separators, strainers, vibration eliminators, sight glasses, and various types of valves are accessories frequently needed for the proper /v.. . L. -* i> <. ; Refrigeration 841 in trater 'lines 'leading; to water' cooled condensers.; .Sight glasses - which permit-visual inspection of the condition'Of the refrigerant are sometimes installed on factory assembled commercial unit systems. It is particularly advisable to place such a fitting before the expansion valve, if the evaporator is located above the condenser. n Flexible vibration eliminators, usually consisting of. a bellows design covered with woven .copper wire, are sometimes installed in, copper lines where units such as compressors are installed on flexible mountings, Or where vibration is otherwise a problem. Packed or packless shut-off valves are necessary where it may be required to isolate portions of a system. Fio. 14. Performance Charactehistics of Compression Refrigeration . Machines at Constant, Speed , :. installation and operation of refrigeration systems.. Refrigerant-line-dehydratdrs or diyeis usually consist of copper containers fitted with tubing connections^ at either end, and contain a desiccant; such, as silica gel, acti7 yated alumina,; or calcium, chloride. ' The liquid refrigeranl'is. circulate(| thrqugh.the.dryer during operation' of the system, and the moisture content of. the Refrigerant charge is thus kept to a minimum. , . . , , ` Oil -separators are installed between the compressor and1 condenser'to prevent excessive oil removal from-the compressor crankcase and its passage into the condenser and evaporator. The oil is separated from the gaseous refrigerant by gravity^, during its passage through a chamber-Of sufficient size to reduce the velocity. A float-operated valve maintains a maximum oil level in the separator, and additional oil is forced by pressure, difference through'a line back to the crankcase. :. Screen strainers are; frequently, installed in the liquid line piping before solenoid valves and expansion valves, as well as before regulating valves Fig. 15. Performance Characteristics of Compression Refrigeration Machines at Constant Speed EQUIPMENT CHARACTERISTICS AND SELECTION The various types of compression systems have quite different charac teristics of capacity and power with varying evaporator and condenser temperatures, as may be noted from curves in Figs. 14 and 15. From Fig. 14 it may be observed that power requirements for the centrif ugal compressor increase much more rapidly than for the reciprocating compressor, with increase in evaporator temperature. Similarly, the ca pacities of-the steam ejector and centrifugal compressors increase more rapidly than those of the reciprocating compressor with increase in evapo rator temperature. Thus, both the steam jet and centrifugal machines tend to be more self-regulating than the reciprocating. It is also evident from Fig. 14 that the steam jet equipment is best suited for operation at high evaporator temperatures. The effect of condenser temperature upon the power and capacity of the different types of compressors is shown in Fig. 15. It may be noted