426 CHAPTER 17 1955 Guide and the amount of exposure to the outdoor air. Experimental data are not sufficiently complete to tabulate efficiencies that take into account all of these variables. However, recommended values of efficiency for several sizes of domestic chimneys of masonry materials and of metal have been selected from the literature6 8* and summarized in Table 1 for use with Fig. 8 in determining the available draft produced by short chimneys of 15 ft in height or lower, in parts A and B of Table 1 the value of efficiency chosen from the range cited should be increased as the chimney inlet temper ature increases over the applicable range. In part C of Table 1 the effi- Tablk 1. Efficiency of Short Chimneys A. Mabonby Chimnkyb "|" : " _c : Hi. Height A ft 5 to 15 Flue Gas Flow Rate lb/hr 90 200 315 Internal Liner Size, in. Dia. 7 7x7 7 x 11 and Dia. 10 Ef iciency, Penoent ' 75-82 83-84 75-89 65-76 67-85 67-86 65-8082-88 81-89 (Inlet Flue Gas Temp 260 to 1006) B. Uninsulated Mittal, Chimneys "y Height A ft Flue Gas Flow Rate lb/hr -c Internal Diameter, in. 6S J Efficiency , Percent 4 to 8 90 90-100 85-95 200 83-88 315 70-80 (Inlet Flue Gas T emp. 200 to 600 F) C. Metal Chimneys1* nr -C J-J| __ 1 Height A ft 8 to 14 Uninsulated 1-in. insulation with dead air space around chimney 1-in. insulation with 1-in. open air space around chimney Efficiency, Percent 76 | 85 | 81___ * Six-inch chimney not recommended for these flow rates. Internal dia. 6-in; flue fp flow rate 50 to 125 lb/hr; inlet flue gas temp. 200 to 1000 F. ciency values listed will yield the available draft for the range of ma flows, inlet flue gas temperatures, and chimney height shown within W percent. In the application of short chimneys, observance of the following Pre* cautions will assist in obtaining the highest practicable draft and may atfe unsatisfactory operation of the chimney and heating plant in certain in stances : 1. Use a minimum length of horizontal smokepipe between the heater and 2. Insulate the smokepipe and the chimney itself, if made of metal. flSe of the chimney liner in masonry chimneys reduces the heat loss from tne gases and the infiltration of cold air. renter 3. Do not use an oversized chimney because larger chimneys produce gr cooling of the flue gases. Chimneys and Draft Calculations 427 4. Avoid downdrafts by proper construction above the roof or by the use of a suitable chimney cap. 5. Avoid the use of barometric dampers in the smokepipe of natural-draft heat era since most barometric dampers permit enough cold air to leak into the chimney to reduce the draft appreciably. 6. Avoid air leaks in the smokepipe and chimneys 7. Avoid connecting more than one heating device to a single chimney. 8. Use construction materials of low heat capacity if the chimney draft must increase quickly for an intermittently-fired heating device. 9. Do not operate a kitchen exhaust fan unless an air intake of ample area is used to prevent lowering the house pressure. 10. Avoid tight utility closets so the chimney draft will not be required to do the added work of drawing combustion air into the closet from the surroundings. Fig. 9. Graphical Evaluation of Rate of Flue Gas Flow from Percent C02 and Fuel Rate" " Average density gas 0.0845 lb per cu ft, 62 F. Average weight oil 7.08 lb per gal, 60 F. . DETERMINING RESIDENTIAL CHIMNEY SIZES The flue sizes for small residential chimneys are governed by the National Building Code of the National Board of Fire Underwriters for gas-burning appliances. Chimney areas for liquid- and solid-fuel-buming devices are selected primarily to meet the requirements of local building codes, but these requirements are not determined by any rigorous formula based on physical principles. By calculating the available draft for the chimney in question, and comparing it with the performance values of the heating unit (either natural or forced draft type) at the desired output, it is possible to de termine whether the chimney is adequate in height for the particular heating unit it serves. For calculations where the fuel rate and the percentage C02 are the only snown factors, the flue-gas rate can easily be determined for coal, oil and 8as from Fig. 9. By entering Fig. 9 at the percentage C02, moving verti cally to the curve for the type of fuel, and then moving horizontally to the fuel ?ra^e' ^'e ue"8as ra^e *n pounds per hour may be determined for any Any of the described methods of determining available draft may be nsed, but a graphical solution to the problem may be had for the 8 X 8-in. chimney from Figs. 6, 7 and 9. This solution can be best explained by a umerical example.