Document 2qkr0Z64B3G7Rea8BzxGX6XYN
wsm. --tteSTrJu T *<-> ri
CHESTNUT RUN LOCATION
November 9, 1966
TO: A. D'ALONZO, M. D. FROJiT 2. WALKER, JR., M. D.
The enclosed letter is in reply to your questionnaire on insulating practices at Chestnut Run.
CW:ef Enclosure
DUP 1110032
SETTER THINGS TOR SETTER LIVING . . . TMROUOH CHEMISTRY'
cc: H. K. Strange W. P. Carlon
E. I. du Pont de Nemours & Company Wilmington, Delaware 19898
CHESTNUT RUN LOCATION
Wilmington, Delaware November 9, 1966
TO:-------JHALKSR. JR.. FROM: L. B. WILSON, JR.
X
INSULATION PRACTICES - CHESTNUT RUN
Ref: Letter C. A. D'Alonzo, M.D., to all Plant Physicians, dated November 8, 1966
I discussed the questions in the subject letter with M. L. Bradley and obtained the following information:
A. How many full-time insulators do you have on your plant? Answer: None
B. How many employees do part-time insulating? Answer: 14
(1) What proportion of the time?
Answer: 5-10%
C. List the (three) most prevalent type of insulating material used.
Answer: The majority of insulation used is preformed fiber gollaseses. VMfd oatgcna ee^saia I "mud^" isa iutesed aa ft> ae1lbows hamnJd joints. Very little asbestos is used.
D. Are they doing any spraying of insulating materials? Answer: No
E. For your reply.
F. List briefly any preventive measures or safety equipment required in your location when:
(1) sawing Insulating materials Answer: safety glasses and gloves
(2) removing obsolete insulation Answer: safety glasses and gloves
(3) spraying insulating materials Answer: not done
LBW/bjd
DUP I|i0033 crrcn thinos row cttcp.livinq ... th*ouoh CHtmarmr