Document 2qZ8v57wZKr7ZRkdbOap3DEXb
uAJ'Oofg
F. R. Sunderland
B. H. Avashia, M.D. J. W. Barna W. L. Browning T. L. Collins M. R. Gandee C. P. Maxwell B. R. McMakin
RCJ Rnx R: 1 ' .Ut i I f I I <AR.
< -
-
October 13, 1986 HS&EA
Industrial Hygiene Asbestos Exposure Monitoring>
Attached are the results of the Asbestos monitoring done on three insulators and one laborer on October 8, 1986. They were monitored while removing approximately 50 linear feet of insulation from a 6-inch steam line. The work was done at the Institute plant's chlorine dock.
They were equipped with two pair of coveralls, head cover, boots, gloves, and an AO R57-A HEPA-half-face cartridge respirator. Their outer coverall was removed before leaving the barricaded area and the employees showered before going home. They indicated that they had not worked with asbestos materials before this monitoring period.
The monitoring results indicate that the sample collected on S. R.
exceeded the 0.20 fiber/cc Permissible Exposure Level (PEL),
established by OSHA for an 8-hour workday (TWAs). The sample collected on
was very close to the 0.10 fiber/cc Action Level, also
established by OSHA, and will be assumed to have been exceeded,
statistically.
; filter cassette was dropped into the river,
therefore her sample was voided.
sample, along with area
samples collected inside and outside of the barricaded area, were well below
permissible levels. This would indicate that the amount of area declared
off-limits was sufficient.
In the future, we recommend that a double check be made to assure that the steam has been cut off, if at all possible, and that the steam line and insulation has cooled down. Hopefully this will eliminate the evaporation of the wetting agent and help to contain the airborne fibers.
UCC 011301
ASBESTOS EXPOSURE MONITORINS
2- -
October 13, 1986
Please notify of their exposure monitoring results as soon as possible. Please
have them sign and date this report and return to M. A. Patel at Building
701-330.
If you have any questions or if we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
iTIaJuui A.
Manhar T..PIte'l-----------
VES:MAP:rab 1800P
UCC 011302
ASBESTOS EXPOSURE MONITORING
Carrp. Ref. W2047
Date
Sanple Type/ Employee Name
Job Classification
Sanpling Tine
Air Cone, fibers/cc
TWq
fibers/cc
COMMENTS
10-8-86 Area
-
5 hrs 9 min. 0.0106
- Collected inside of the barricaded
area beneath the pipe rack near the
on-rarrp.
10-8-86 Area
} 10-8-86
Insulator n
5 hrs 6 min. 0.0018
5 hrs.
0.152
-
0.095
Collected outside of the barricaded area near the barge.
Collected while stripping and bagging, at the point of removal, approx. 50 linear feet of asbestos with 2 other insulators.
io-6-es
m
Insulator
4 hrs 56 nrin. 0.827
0.510
Collected while stripping and bagging, at the point of removal, approx. 50 linear feet of asbestos with 2 other insulators.
Insulator
'
'
Voided - Filter cassette was dropped into river. She also was involved with stripping the 50 linear feet of asbestos.
10-8-86
Laborer
4 hrs 49 nrin. 0.0293
0.0176
Collected while cleaning up the asbestos dropped to the plastic, handling bags, etc.
ASBESTOS
Permissible Exposure Level TWft 0.02 ~Fibers/oc OSHA
UCC 011303
1800P