Document 2qX343okKEBJYM4ajmYrGr2yR

1985 3rd Quarter Housekeeping Inspection Emphasis Areas: Ladder Inspection JSA Training Program Bypassing Protective Devices o Grinding Wheel Tool Rests o Hurricane Procedures 0 Chlorine Cylinder Installations Review findings with group before leaving. This will take longer, but will Improve communications and speed up action items. Allow for some time in each area to sit down with supervisors and hourly personnel for an informal evaluation. During the Inspection: Ladder Inspection - Ladder must have a visible sticker at eye level -- "INSPECT LADDER BEFORE USING." Ask questions about the JSA Training Program (should be completed). Look for Bypassing Protective Devices a) Is procedure bulletin manual updated? b) Have revisions been communicated to personnel? c) Is current practice consistent with new guidelines? Grinding Wheel Tool Rests a) Gap between wheel and tool rest is to be no greater than 1/8" according to OSHA. b) Machinists should be set up to check grinders on a weekly basis. Hurricane Procedure a) Review present procedure for dealing with empty storage tanks when a hurricane warning is announced. b) At what flood level will tank begin to float? Chlorine Cylinder Installations -- inspect for: yellow painted lines cover goggle signs breathing air station safety shower Dates: Weeks of September 9 and 16 (inspection report out by September 25). Schedule at inspector's convenience. Inspection Teams: (attached) Inspection Report Feedback: By October 25. DAB/msd 8/26/85 sc 000265 LAM001462 GROUP I Units 13/14 15/16 *^51 ^ 48/56 ^44/45/46 Contact Rudy Willis Rudy Willis Hank Vanderford Vernon Fields Ken Gore Inspectors GS: -R-. L Ilammond CS: Pinky Cole HSC: Charles Anders - SHAC: Bob Hammann Jim Cavendar Phone 3632 3632 3348 3187 3779 Phone 3859 3756 Matl. Handl. (Glenn Vogtman 3927) 3234 3446 000266 LAM001463 CRAFTS Craft Instrument Painters Insulators Pipefitters Carpenters Boilermakers Machinists Electricians Operating Engrs. Contact Roger Mears Bob Bohmler Bob Bohmler Ed Dowden Bob Bohmler Bill Recknor I. W. Cole A. R. Mathison Bill Recknor GS: CS: HSC: SHAC: Inspectors Ray Forsthoffer Bill Wooley Steve Broom Rick Sharp Phone 3244 3723 3723 3280 3723 3331 3756 3329 3331 Phone 3833 3465 Dept. 51 (2523) 3211 LAM001464 SC 000267 GROUP II Units 513 53 50 Matl. Handl. 33 P2 HCN Contact Bill Wooley Vernon Fields Ken Gore Glenn Vogtman George Chesnut Dan Davidson George Chesnut GS: CS: HCS: Inspectors George Bostick Marvin Lee Donnie Lonsford SHAC: J. M. Gatewood Rich Coleman Phone 3465 3187 3779 3927 3574 3839 3574 Phone 3715 3514 Insulators (Bob Bohmler 3723) 3837 3545 SC 000268 LA/VI007465 LABS Research I Research II PETS Lab QA Lab Contact Charles Scott Diane Douglas Danny Gibbs Doug Hiser GS: OSC: TCSC: SHAC: Inspectors John Wilbeck Edwena Williams David Hanson Doug Barfoot Phone 3610 3548 3281 3064 Phone 3237 3640 3101 3496 SC 000269 LAMOO 7466 OFFICES/SERVICES Too many and too diverse to announce to any one person. Just go inspect. GS: OSC: TCSC: SHAC: Inspectors Bob Ceyanes Sue Villcox Frank Bryant B. J. Sanders Phone 3153 3911 3887 3270 SC 000270 LAM001467 OFFICES/SERVICES Fire Station Stores Zone I Warehouse Warehouses A, B, C, D, E, F, G Cafeteria Health Services Main Office 2nd Floor 3rd Floor Office Annex 1st Floor 2nd Floor Records & Benefits and Purchasing Locker Building No. 1 Guard House - Main Gate CED Offices CED Warehouse LAM001468 SC 000271