Document 2mVZbBX2RQVx1GmGd549kn4L

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page @ Page 9 Page 10 Pace 11 BESTWALL GYPSUM COMPANY SEMI-ANNUAL RESEARCH AND DEVELOPMENT REPORT Jan., ltf 1964 to June 30, 1964 TABLE OF CONTENTS o * n ** ,, * eo i\o reword ''v Market Performance of New Products Patent Information 0**9 ebo Projects Completed Ready Mix Joint Compound - R k D 211 o s Ready Mix Joint Compound Picture 9009 Water Resistant Wallboard - R & D 20Fire Rated Columns - R & D 270 o oo 2=Hour Firestop Ceiling with Light o' Vent Openings - R & D 266 & Picture One~Hour Fire Rated Imcombustible Floor & Ceiling * R ca D 267 One Hour Wood Floor Ceiling - R k H 2St 2-Hour Rated Steel Corruform & Concfcnte Floor & Ceiling = R k D '2lT<St Co-operative Tests on liof-JCor Honeycomb Panels R & D 257 One-Hour Rated Dens-Cote Partition R & D 219 Co-ccerative Tests with Donn Products R & D 259 - Improved Sound Transmission Using the Combination of Insulation Board k Ovrsm Board R is D 260 *3 9 9 * 9 Projects Nearing Completion Joint System Textures ~ R k D 261 090 ' COOO (/ c a * o O C* C` Hammer System " R & T) 209 k Pic dure High Expansion Densite R k. D 13,2 Ram Process Densite - R & D 132 SGP 0014878 TABLE OP CONTENTS (CONT:D) J.u w * e r, -a * improve Flame Spread Hating of Eternawall - R a. D 215 2---Hour Fire Hated Wood Joisted Floor-Ceiling - R & D 273 Page 13 Dry Vinyl Topping Compound - R & L> 21j Page 13& 14 . ,, ,, . * Synthetic Gypsum - R & D 221 Page To * -* , Projects Underway Owens-Corning Projects - R & D 210 r>age J.o O 9 ti Dens^Cote System - R Q 219 Tooling Densite * R & D 132 Radiant Heating Panel - R & D 235 Calcination and Particle Size Studies R & D 263 Pa<*e 17 y a o n New Wood Grain Products - R a D 268 Gne~Hour Partition with Good Sound Properties R & D 271 Page 18 Page d r% OOUHOC Gypsum Acoustical Tile ~ R & D 278 Protein Joint Compound Formulations R & D 275 Sound Rated Constructions - R & D 2 VO* r**, -to 20 - P* S Cf-& 21 Dimensional Change of Gypsum Products at High Temper ntmrss -- R & D 277 Cooperative Research Program with Jehu Manviiie - R & D 278 Concrete & Ear Joist Ceiling with l/2M Firestop - R & D279 Summary SGP 0014879 .1 FOREWORD This report covers the activities and accomplishments of the Research Division for the first 6 months of 1964r There has been no personnel change in the Research Division during this period,, It was estimated last January that the total 1964 R&D expend!tures would approximate $150*000. The first half figures show that $65,895 has beenspent thus far. The Research Division had its third anniversary in June, h rundown of the last 6 months* market performance of products resulting from our efforts since that time follows Some of the accomplishments, such as fire ratings acquired, cannot be directly assessed However, the fact that our l/2M Firestop sales are up 106% and our 5/S" Firestop sales up 27% for the first 6 months cf 1964 over a like-period in 1963 is a good indication of the value of this effort. The major portion of this report is devoted to the progress made on the various projects during the past 6 months. It is divided into three sections, namely: 1 Projects Completed 2. Projects Nearing Completion 3. Projects Underway SGP 0014880 *MARKET PERFORMANCE OF NEW PRODUCTS JANUARY THRU JUNE 1964 PRODUCT Firestop 120 Ceiling Tile ,!Grabt,! Masonry Adhesive One Day Joint Compound Dens-Cote Plaster Dens-Cote Base (all) Dens-Cote Tape rfM Drywall Sc rev/s Ready Mix Joint Compound Water Resistant Board Model Densite High Expansion Densite SALES VOLUME MILL BASE SALES GROSS PV 306,000 sqt0 $ 42*371 $ 12,55? 22 Tons 264 Tons 718 Tons 4*211 46,633 38,908 /Cm * A- *_/ 1 ^ ^4r>* C'f'y f q l r>r-r>\ 3*82106 M.SqF 0 .161*337 OO,v^I 6*462 Rolls 6,305 ./ O f & 872 Gross 2,321 305 2,414 Pails 11,008 ' 1,617 23,700 Sq. Ft,, 1,684 1,046 1 Ton 07 Ton 35 14 31 rt? $314,894 $104,776 'Obtained from Paoii machine accounting records, PATENT INFORMATION Patents Issued - None Patent Applications Prepared *- Dens-Cate Plaster Dsns"Cote Base Patents Applied For - None Patent Applications Previously Submitted -- Processing of Synthetic Gy* One Day Joint Compound Grabit Adhesive SGP 0014881 PROJECTS COMPLETED READY MIX JOIN F COMPOUND - K & D 211 Objectives To develop a ready mixed or paste type joint compound to be competitive with other similar products on the market* Investigation: About two years ago, a basic ready mix formula was developed and successfully field tested* At that time, it was decided that the product would not be put into the line, because (1) the product was not economical due to the freight involved in shipping the pails of ready mix to the potentially good markets; the freight involved in shipping the dry premix from Acme to other plants for conversion to the paste compound; and the relatively high cost of the formula* (2) The question able market potential. Surveys indicate that the demand was spotty and confined to a few areas which would be least economical for us to ship. (3) The relatively large investment required for equipment to mix, fill pails, store and transfer emulsion, and provide storage for raw materials and finished products* The second phase of this investigation was begun because of renewed interest from certain parties in Sales, a second basic joint system plant put on stream at Akron, and our own reali zation that ready mix was becoming a product we would have to reckon with sooner or later* In order to overcome the necessity to purchase large tanks and provide warm storage for binder (PYA em&lsion), a ready mix formula which contained a dry binder was developed. This formula cost was Also high, but it did circum vent the large equipment expenditure. A small facility was set up at Akron to furnish the requirements of a large high-rise job* The job never materialized; the ready mix froze and thawed several times during the subsequent winter; and it was obvious that the area serviced by Akron was not a good ready mix market, in view of the meager sales* In spite of this bad taste from ready mix, it had become apparent that ready mix was the preferred joint system in some markets, it is becoming a factor in other markets and is being used for touchup and by "do-it-yourselfers'* even in the areas where other joint system products are preferred. `Jur previously expanding joint system business has leveled off the past two years, and it is felt that lack of a ready mix product has been one cause. It was decided that ready mix should be available from Acme, Akron, Brunswick', Fort Dodge, and Wilmington* This constituted the third phase of the ready mix investigation. Result: Brunswick and Fort Dodge have already been put into operation, and Akron is continuing to furnish their own require ments as well as supplying Wilmington* Based on the performance of these operations, the other facilities at Acme and xmzngton will be installed* The cc-st of the equipment inciuaing mixer lid closer, pail filling ram & pump, accessories and installation of the equipment is about $6000 per plant* The pail filling device which is rather inexpensive has improved the capacity of these installations* Some economies in the formula have also been realized, so that the ready mix operation should be more profitable o3- SGP 0014882 than originally expectede Vv'e returned to the emulsion binder, in view of its lower cost and also because it gave a better end product than the dry resin binder# If the volume can justify the purchase of emulsion in large quantities, a furthe savings of up to 20d/pail can be realized* A photograph of a 5-gallon pail of ready mix is shown below: tin ^ SGP 0014883 2. WATER RESISTANT WALLBOARD - R & D 264 Objective: To develop a water resistant wallboard for use in moist areas. Investigation: This project was prompted by National & USG introducing special wallboard products for use in bathrooms and other moist areas. We decided to pattern our product after the USG W/R board, because it was decided that USG'sproaucb was more acceptable to the trade. This board consists of a special asphalt wax emulsion treated water resistant core and a special highly sized face paper to resist the effect water has on gypsura board. As a further precaution, a vinyl tape was found which is used to seal all cut edges and joints. USG recommends that a special sealer be used for the cut edges. It is felt that the tape is more foolproof and more practical. Ln order to use the sealer, brushes and thinner are needed; and the sealer must be applied before the board is installed. The tape overcomes these dis advantages. Result: Two successful runs of this board were made at Brunswick and Fort Dodge. Sales has processed a request to add this product to the line and have it available from those plants. Subsequently, Fort Dodge has made a run, but the water resistance was not satis factory. it is felt, however, that this product can be manufactured within the limits set and will be fully competitive with USG and National's water resistant wallboard products. 3. FIRE RATED COLUMNS - R & D 270 Objective: To find a means of encasing a steel column with wallboard so that 2 and 3 hour fire ratings can be obtained. investigation: An encasement was devised consisting of 3 layers of 5/8" irirestop attached to metal studs with a wire tie arcund the first 2 layers. The metal studs have two functions: They offer a secure attachment for the layers of *'irestop, and they enable 2 sides to be prefabricated, which greatly simplifies the installation. Result: The 3 layer 5/8" Firestop encasement protected the column ror 3' hours and 45 minutes. This success promoted us to quickly test the same construction with 2 layers of 5/8" Firestop and no wire ties. The desired 2 ho?ar rating -was easily achieved as the construction lasted for 2 hours and 20 minutes. A request is being made to Underwriters' that they give us the h ur rating for one layer and 4 hour rating for 4 layers, of 5/b Hreg top without runnir^ the tests. Designs of one layer and 4 layer applications nave oeeu orepared. These fire ratings give as a big advantage over our competition in this ares. The only company which has a 3-hour r layers of 5/8" Firestop is USG, and their protective o*. o *2 i-is, G i t & is considerably more difficult than curs to install. 5 s SGP 0014884 4. -HOUR FIRESTOP 120 CEILING WITH LI HUT & VENT OPENINGS ~ RS:D Objective: To incorporate light and' vent openings in our Firortc 120 Ceiling and retairf the 2 hour rating,, The test is to be con ducted at Underwriters*, in order to get the U* L,, label* Investigation: Quite a lot of time was devoted to the light protection system used, inasmuch as this would probably decide whether or not the test would pass* Adequate protection was only one objective* It was decided the 5/8" Firestop should be used for this light protective covering, and we wanted it to be easy to install, so that the relatively low cost of the installation could be promoted* Result: A 3-piece covering was devised that can be installed in a matter of few minutes* The construction passed the 2 hour test, so the U. U0 label and the economical light protecti* n should help sell the Firestop 120 Ceiling* A picture of the light protective method is shown below0 -6 - SGP 0014885 5,, ONE HOUR FIRE RATED INCOMBUSTIBLE FLOOR & CEILING R & D 267 Objective: To develop a one hour rating for a 2" concrete and steel bar joist deck protected with l/2" Firestop# Investigation: This deck was constructed in a similar maimer to that used in the 2^" deck protected by 5/3" Firestop, for which we already have a 2 hour rating# Furring channels were located on 24" centers and screw fasteners on 12" centers, as had been done on the 2 hour deck# Result: The assembly lasted for one hour, 45 minutes* and thereTore received a ijr hour rating# After our successful testNational Gypsum tested a similar deck with 2^" of concrete and received a 2 hour rating. This somewhat took the edge off our achievement, but we are still the only company to have 1-f hours for this lower cost construction# 6# ONE HOUR WOOD FLOOR CEILING - R & D 256 Objective; To test a wood joisted floor protected wit/1 1/2" Firestop attached to resilient channels for sound transmission# A fire rating of 1 hour has already been obtained# Investigation: A panel was constructed at Riverbank Acoustical Laboratories to be tested for airborne sound transmission# Result: An STC rating of 47 was obtained# This compares with 45 o National Gypsum Cush~N~Ciip system and provides us with a relative! inexpensive fire rated and sound rated wood floor as a means to promote our l/2" Firestop# 7 2-HOUR RATED STEEL CORRUEORM & CONCRETE FLOOR & CEILING - R & D 272 Objective: To have Underwriters1 make a study using their explora tory test equipment, comparing concrete and steel Corruforn versus concrete and steel bar joist construction# The objective is to permit them to allow us a 2 hour rating on the Corruform construc tion# Investigation: U- L# informed us that the steel deck construction developed'higher plenum temperatures during the coarse of the test, and therefore they could not extend the rating# ResuT Sales has requested we conduct the full scav.e tesr neces-- sary to gain the rating# American Gypsum Compan our licensee, has sold a job on which the insurance can be substantially reduced., if the 2 hour rating is obtained# The only possible difficulty may be the necessity to adhere to certain details of the construc tion, if they happen to be detrimental tc a good test construction. 8,, CO-OPERATIVE TESTS OH HOF-KOE HONEYCOMB PANELS * R t D 257 Objective: To test a partition of Hof-Kor prefab panels consisting of a paper honeycomb core and 5/3" Firestop Eternawall faces to achieve a one hour rating# Union Bag-Carap Corporation has shared in the cost of this test# SGP 0014886 Investigation: The fire endurance test was passed on the second, try, but three efforts to pass the hose stream test have been unsuccessfulc It is felt that the small headed Kolorpin fastener: required in this construction, and the tendency of the vinyl surfacing to act as a moisture barrier, caused the failure* Result: It has been decided to close the project with an unsuc cessful conclusion. Sales is requesting that another test be made with regular instead of Eternawall Firestop faces, but this will be handled as a separate project, if the test is approved* ONE HOUR RATED DENS-COTE PARTITION - R & D 219 Objective: To gain the one hour rating with a raetal stud part it icfaced with l/2" Firestop Dens-Cote Base and Dens-Cote Plaster. Investigation: Two previous partitions with Tigerskin arid- l/2" Firestop Dens-Cote Base had failed. The partitions were construct at Underwriters1 and l/8" of Dens-Cote applied. In the test of th first partition, a crack developed in the center board, and the te reached only 53 minutes. Thinking the board may have been pre cracked, the second partition was tested. This time one of the joints opened up and failure occurred at 55 minutes. The Dens-Cot obviously did not offer any protection in itself, and possibly did some harm by causing some unusual stresses. Result: No further efforts are planned, inasmuch as we appear to have exhausted ideas to allow us to pass. Mo competitor has passed one hour with this construction at U,, L. Pabco has passed the test at BeffKely, and this was one reason we were asksd to develop the rating. 0. CO-OPERATIVE TESTS WITH DONN PilODUCTS - R & D 259 SGP 0014887 Objective: To co-operate with Donn Products in a test of their Moaumaker partition using 5/$" Firestop Eternawall faces. Investigation: We were obligated to cooperate in this" test, 'beeause by error, 5/8" regular Eternawall was sent to Ohio State for Bonn's first attempt; and they failed at 53 minutes-. Result: With 5/8" Firestop Eternawall in the same construction, the endurance time was 72 minutes, indicating the difference in fire protection betiveen regular and Firestop boards. IMPROVED SOUND TRANSMISSION USING THE COMBINATION BOARD & GYPSUM BOARD - R & D 260 ULATXCN Objective: To assimilate th data from tests conducted by 4* *% K* i:... insulation Scard Inst it v/c e ana dispe.se them to our Sales, the use of our products i n these constructions. Investigation: The data was put into order showing our wal 1board and Joint system products and presented to Sales for use in proEiot cur products with these systems. Result The information was sent out in a sales bulletin. with a PROJECTS NEARIN'? COMPLETION , JOINT SYSTEM TEXTURES - R & D 261 Objective: To develop pre~aggregated textures for spray application* Specifically, these textures are: 1. Simulated Acoustic (coarse aggregate) 2, Sand Finish (fine aggregate) 3* Masonry (coarse aggregate with rust inhibition properties) A further object is to develop textures that can be used over surfaces where One Day Joint Compound has been used for the joint finishing, without the necessity of first using a primer* Investigation: The three products listed above were developed to the trial stage sometime ago* This was during the reorgani zation of the Sales Department, and the trials never materialized* In some instances the material was lost or used and never reported on. Additional trials were requested, and these were slow to be scheduled. In desperation, it was decided to make these textures available in the area served by the Fort Dodge plant. A quantity of each of the various textures, including a plain (non-aggregated) texture designed to cover One Day without a primer, was shipped to Fort Dodge. Wherever possible, the trials were witnessed by Laboratory personnel. The trials provided some differing opinions but, in general, some unfavorable characteristics prevented their acceptance. These were: 1. When dry, the textures developed a sheen that made the ceilings appear blotchy under severe lighting conditions. 2. The textures would build up locally instead of flattening out as they were applied. This was not too detrimental for the simulated acoustic but caused the sand finish to be coarser than desired* 3.The plain texture covered the One Day satisfactorily in some cases but not in others, so it also failed to achieve our expectations. On the basis of this experience, it was decided to return all of this texture to Akron and rerun it at a later date. The texture project was brought back to the experimental stage, and means 'were sought to overcome the objections. It became evident at this time that we should develop the basic textures needed for addition to the line, without regard to their ability to cover applications of One Day Joint System. After reformulating the produ j on this basis, some trials were conducted in the bBrruunnsswwiick area. The trial of masonry texture did not materialize, but the sand finish and simulated acoustic products were found to be satisfactory and overcame the previous objections. The field testing will be continued with additional trials in Kansas City and Hartford, Conn. Trials previously conducted at these locations drew unfavorable comments, so this will confirm whether he necessary corrections to the formula have been made, If these trials are successful, we will consider SGP 0014888 approving the two products for release,. As yet, insufficient trials of the masonry texture have been conducted to determine whether this product is going to be acceptable* HUMMER SYSTEM - R & D 209 Objective: To develop improved laminated gypsum ribs for Hummer partition systems* Investigation: It was previously reported that a B^-M thick x 3" wide riS had..been developed, and field trials were being requested After some futile attempts to have trial partitions constructed with these ribs, one was finally found in Washington, i), C,, for approximately 100 linear ft, of partition. The advantages brought out in this trial were (1) the ease of installing electrical facilities, and (2) the increased stiffness of this partition. Concurrent with this development, Mr. Hummer modified the instalia tion procedures for the Hummer ''B'* System, so that the ribs could be set in metal U channels similar to the manner metal studs are set in place before the faces are applied. The new rib and the improved method of installation should overcome all of the advan tages previously held by metal stud systems. The next phase is to have one large trial job completed with the new ribs, so a more thorough evaluation will be possible, A picture of the new rib is shown below: - 10 SGP 0014889 3,, HIGH EXPANSION DENSITE - R &D 132 Objective; To develop a high expansion Densite suitable for U3e as a casting plaster for Kirksite dies used in the forma tion of automobile bodies. Investigation: A product was developed based on the use of a sugared land plaster accelerator which gave the desired expan sion in the required length of time* The presence of the sugar gave the formula resistance to ageings, which is very important in this product* The patterns cast from the plaster must expand l/S" per footc as this will counteract the same amount of shrinkaa in the Kirksite normally cast in such molds* If the expansion is insufficient, excessive machining of the Kirksite is necessry* The sugared land plaster formula was made up in a small quantity at Blue Rapids and sent to Clapman Pottery Shop in Detroit for trial* The trial was very successful on both large and smallscale molds* Hie sugared land plaster has been made by hand in the lab, and some more practical means of manufacturing this raw material was sought. It was finally decided to have Fort Dodge manufacture sugared accelerator blocks on their block machine. In a subsequent trial of the high expansion plaster using the Fort Dodge block, the formula was found to lose its expansion characteristics with age* It is theorised that casting large blocks permitted migration of the sugar and therefore loss of its anti-ageing effect. New means are being studied to make the sugared land plaster. Further trials have been called off and will not be resumed until this problem has been solved. 4. RAM PROCESS DENSITE - R & P 132 Objective: To develop a special pottery plaster for use in the kam Pottery making process. Investigation: The past history of this project has been one of repeated test failures* Partially this has been due to a lack of complete understanding of the problem. As a result of some recent cooperation from Phaitsgraff Pottery in York, ?a,,. it is felt this situation has changed,, Phaltsgraff recently loaned us two yokes into which we could pour experimental castings. Ure were able to subject these castings to the purging by as much as 100 psi air pressure, which is a part of the Ram Process making process* Heretofore, we were unable to similate this operation. The yokes were sent to Blue Rapids so that we could take full advantage of Phaltsgraff8s generosity* Ordinarily this work could have been conducted at the Laboratory but, in view of the building rennovations, it was done at Blue Rapids,, The tests at Blue Rapids indicated that a fast setting time was necessary to develop the greenstrength quickly, and. this fact, rathe? than porosity, would enable the castings to 'withstand the purging. A formula which held up under 148 psi was selected, and a sample sent to Phaltsgraff. However, cur troubles continued to haunt us, and another unsatisfactory trial was recorded. This time, accelerator lumps formed during the soaking period and caused the slurry to set before it could be used. It is - 11 <&> SGP 0014890 felt that this was due to low solubility of the K2.SO4 accelerator used* An evaluation of various other accelerators is nov; under way, to turn up one which will perform in the manner required* IMPROVE FLAME SPREAD RATIMO OF ETERNAWALL - R & D 215 Objective: To achieve a flame spread rating of 25 or less. Investigation: The flame spise&d rating was previously reduced lro"50 to 35 by using a Borden flame retardant adhesive and the regular vinyl film used for Sternawall* This rating is acceptable in most cases* but there are certain instances where the code requires a rating of 25 The Border. Company was unable to control the quality of their adhesive so that it could be used in our laminating process* Therefore* even though we ha'/e the rating, we cannot use it* The search for a new adhesive resulted in one from Monumental Adhesive Company, which performed satisfactorily* In order to confirm this, a larger trial was conducted, and again the results were excellent* At the same time, a thinner vinyl film was suggested, and some trial runs of 6 and 8 mil vinyl were compared with the regular 10 mil vinyl* It was decided that the 8 rail seemed to be satisfactory in every respect, and in addition, it is felt that the thinner vinyl might yield a better flame spread* There is also a potential savings of about 05d/sq,, ft. in the cost of the vinyl film. A flame spread test of the 8 mil vinyl laminated with Monumental flame retardant adhesive will be made at U. L*, as soon as the necessary arrangements can be made* TIVO HOUR FIRE liATED WOOD JOISTED FLOOR-CEILING - R & D 273 Objective: To test a double layer 5/3" Firestop ceiling beneath wood joists in order to obtain a 2~hour rating. Investigation: There are apparently certain codes which require a 2 hour rating for this construction, but they are not enforced because no one has such a rating* Sales has requested that we seek the rating, because they feel that it will give us a promo tional advantage over our competitors^ particularly in areas where this 2 hour code requirement exists. Before spending the $5000 or so, which the large scale test costs, two exploration tests were run in Ohio State's small (4'x7?) furnace* The first test was identical in detail to the one hour construction we have with resilient channels and l/2,f Firestop under wood joists. This was for comparison purposes. The construction tested in the small furnace consisted or ..a layer ro\f 5/8" Firestop nailed to wood joists, resilient channels, and another layer of 5/8" Firestop,. in rirst test la; or aoout 60 minutes and performed much like the same const action ested at U. L The second test was stopped at 1 hour 5 we felt was near the end; but we wanted to be able to see the condition of the joists at this point. After our examination, it was felt that the construction probably would not have lasted too much longerp which means that it would probably have been a couple minutes short 01 ILoa-rs in a large test* if our cor re- lation is that close* - 12 - SGP 0014891 We believe that if the face layer of 5/8" Firestop can be held in place longer, there will be a good chance of making the 2 hours. On this basis* the large scale test was recommended. Certain changes in fastening will be made to hold the face layer on longer. The AFE has been approved* and the construction and test are scheduled for late July or early August. DRY VINYL TOPPING COMPOUND R & P 211 Objective: To formulate a topping compound with a vinyl binder instead of a casein binder. It is intended that the t'inyl top ping will be a superior product. Investigation: The investigation was originally directed to the development of a dry vinyl joint compound. Bonding difficulties at low temperatures caused us to direct our efforts to a topping; compound, in which the bond is less critical,* The advantages of a vinyl formula are: 1. Longer wet life, since it is not subject to putrefaction to the extent that casein topping is. 2. Offers better control from the plant standpoint because of simpler formula and more uniformity of the binder. 3. Requires less mixing water so there is less shrinkage. 4. Offers better working properties than its casein counter part . 5* Is compatible with One Day, whereas casein topping is not. Field trials of the vinyl topping were conducted in Nashville. Tenn. and Hartford, Conn. The comments were favorable, and its performance was satisfactory. Also, this product was used for some of the joint finishing in the Laboratory during the rennovation of the building. Most applicators commented that it works like ready mix. It was hoped that the vinyl formula would not be significantly higher in cost than regular topping, but this did not prove to be the case. The vinyl topping has a raw material cost of $; 84/ton as opposed to $6/ton for the regular topping. In view of the advantages of this topping, the Laboratory will propose that the product be released and sold at a premium price. 3. SYNTHETIC GYPSUM - R & D 221 SGP 0014892 Objective: To confirm the results of the initial trial run which indicated that synthetic gypsum could be successfully utilized for wallboard and plaster manufacture. This process involves conversion of the synthetic gypsum by product of the manuxacture of phosphroic acid to a useable form. Investigation: The basic operations of this conversion orocess for which a patent has been applied are as follows: I.Drying of the synthetic gypsum as received. The latest shipment containeo 20fo.free water. 2, Neutralization with precipitated chalk or finely ground limestone, 3, Calcination by the continuous calcination method., 4o Tube milling to impart sufficient plasticity, 5. Manufacture into wallboard by reducing the belt speed and shutting off the first section of the kiln. The slow hydration.rate of the synthetic stucco makes these steps necessary. The board produced from this run is considered to be very satisfactory and equal in all respects to wallboard made from conventional stucco. Board made by this process 6 months ago (first trial) shows no effect of deteriora tion or degeneration. The better than 20,000 sq. ft- of board from this latest trial run was shipped and presumably has been used without comment from the trade. No announce ment or distinction of any kind was made when this board was shipped. Advantages of synthetic gypsum^oyer natural gypsum are: 1. Unlimited source of raw bvpsuib. 2* It is presumed that the synthetic will cost less than natural gypsum, providing there is little or vm freight involved in transferring it to our facilities 3, No investment in mining or quarrying equipment would be required. The next logical step would appear to be a run of some duration, perhaps a week or so, in order to make a full and final assessment of the process successfully tried on the two previous occasions. - iA -- SGP 0014893 ROJECTS underway OtfEKS-CORNIW? PROJECTS - R & D 210 Objective: To evaluate a glass fiber roving with finer filaments Investigation: Por some time ive have been using a type glass Tiber with about 12% DE filaments (.00026" dia.) and 83% G filare (.00038" dia,,). This fiber, called 799, is furnished by Owens Corning. A short time ago, Owens Corning advised that they are now in a position to regulate the proportions of the two differon diameter filaments. Since there are twice as many individual filaments per pound of the finer.fiber, we naturally asked to be furnished with 100% finer filament DE fiber.. They stated that this could be done and are furnishing us with sample spools which we can evaluate. Tneorticaily, our fiber requirement should be able to be reduced by one-half for regular board (not Pirestop) if -we eass use this fiber. Our objective is to realize the potential savings from this fiber. DBHS-COTB SYSTEM - R & D 219 Objective: To evaluate Dens-Cote for application over radiant heating cables. This was requested by Sales. Investigation: Both the smooth and texture finish Dens-Cote formulas were applied over a 4* x 8* panel to which a length of radiant heating cable had been stapled. This panel was energized and has been kept under surveillance for several months. After the initial observations showed no adverse reaction, it was agreed to approve a trial application on one unit of an apartment in Syracuse, N. Y. Texture finish Dens-Cote was specified, since thermal cracks which might occur would be less likely to be visible. The trial applicat iOTl proceeded without difficulty, and the contractor expressed a desire to put radiant ceilings with our Dens-Cote on the res:a.indr of the apartments. One further 1200 sq. ft. apartment has be sr.i agreed to, but nothing beyond this*>i!.t.smuch as we want to v;aa until the installation has gone through a complete heating re before giving it cur final approval. DENS-COTE SYSTEM - R & D 219 Objective: To modify our Dens-Cote so that it will meet the requirements of the Chicago Housing Authority. Investigation: The Port Dodge Dens-Cote smooth finish formula was revised by incorporating a lower T. C. tubed stucco, in ore to increase the compressive strength. This change enabled the compressive strength to be increased from 2500 psi to 2300 per. eouirement of the C.K.A. is an abrasion test. Tne :ec ic at ions for rest have ist been received and call .1 ^ i. Taber abrasion test, life are looking into the possibility of having these abrasion tests made for us, 15 SGP 0014894 TOOLING DBNSITE - R & D 132 Objective; To develop a tooling plaster which will meet the requirements of the aircraft industry* Investigation: Our efforts have been directed to the development of a formula which would meet the requirements of Lockheed Aircrai The specifications were met and passed* as witnessed by Pittsburgh Testing Laboratory. This report was submitted to Sales* and they subsequently reported back that Lockheed had changed their specix; cations and that a very fine grind is needed which we could not pass with our present grinding equipment. It would seem cations of Lockheed to meet* it may be possible to develop a better product; so this is the approach being taken, RADIANT HEATING PANEL - R S D 235 Objective; To develop a gypsum wallboard panel with electric radiant heating properties. Investigation; It was last reported that a gallonrof-.Electronics biscoyery OorpQrat ion* s ''Aplotheria" conductive coatirrg material had been ordered. We were charged $100 for this gallon of materia after several outlandish proposals of theirs were rejected by us, A 4* x 8f panel was fabricated, consisting of a layer of "Apiother between a piece of 3/8" wallboard and a piece of 1/4" wallboard. The l/4" board is on the face side to allow the least possible thickness for the heat to pass through. The QApiothern" was applied in five roller coater applications and serves as the laminating adhesive as well as the heating element. Flat braided conductive 3trips are located in the depressions provided by the tapered edges. Tnis panel has been energized and provided a surface temperature of 90 - iOQF. for several months. The next step will be to actually heat a space with these panels. This will be done after we get into the new building. Calcination and Particle Size Studies - R &. D 263 Objective: To increase our knowledge of processing gypsum for ;ie manu'f acture of wallboard and piaster. Investigation: A new method of analysis, utilizing a vacuum was 'founci^nc'T to be dependable A modification of this method. v;.?j worked out in conjunction with Mr. Kuntze of the Ontario Research Foundation. This method involves exposing the samples to 90% relative humidity in order to hydrate the soluble anhydrite. Samples cf kettle calcined and continuous calcined stuc co have been analyzed by the revised method, and the result re reason. reproducible. Differentia,1 thermal analyses prepared e n these same samples by the Cntari o Research Foundation agree f airly wai1 with the chemical analyses . The revised analysis methe d is ores en being considered in Commit tee C-ii of AS7M. - 16 - SGP 0014895 The second phase of this investigation deals with the study of particle size gradation, A Coulter Counter was purchased to enable us to determine the particle size distribution, which is finer than 325 mesh or 44 microns. Quite a lot of time was spent in familiarization with the Coulter Counter and tracking down and eliminating various discrepancies that occurred. This work had been completed when Mr. Hinkel, who was doing this work, had an extended illness. He has now returned and the particle anaysis has been resumed. Samples of three different grind stuccos were obtained from Blue Rapids and submitted for Coulter Counter analysis as samples 1, 2 and 3. Sieve analyses had been made, but these results were not revealed to Mr. Hinkel. The subsequent Coulter Counter analysis picked out the samples in the proper order and gave us some information that heretofore had not been available. For example, we found that 85% of the Blue Rapids tubed stucco sample was finer than 4 microns. It will take an accessory piece of equipment to measure particles finer than 4 microns, so this is now under consideration. Other testing will be done to give a more comprehensive evaluation or the equipment, but it appears that it will enable us to increase our knowledge substantially in this area. NEW WOOD CRAIN PRODUCTS - R & P 268 Objective: To develop new grainboard patterns, competitive with USG's Ultrawall. Investigation: Sample boards of Masonite grainboard, l-SO UItrawallg and large samples of wood grain paper from Di-Noc were displayed alongside one another for comparative purposes. It was decided that the Di-Noc paper appeared to be very satis factory, but that we would require the depressed striations similar to those in the Us1* and Masonite products. It has net yet been decided how many new patterns will be offered# whether they will have a vinyl covering, or whether we will striate sos of our present grainboard patterns. The equipment to perform the striating is presently under investigation at Fort Dodge. ONE HOUR PARTITION WITH 000D SOUND PROPERTIES - R is D 2'\ Objective: To develop a wood stud partition which can be promoted along with the one hour wood ceiling which has a sound rating of 47 STC. Investigation: Our first thought was to build and test a partition"simi1ar to the one hour ceiling construction, i.s,, resilient furring channels attached to the studs and 1/2" Firestop, screw attached to the channels on each side. Tills partition was tested and failed miserably. lifter our sound :stmg program :.s completed, some stter sound isolation constructions will be considered for mother firs test. - 17 SGP 0014896 9,, OYPSUM ACOUSTICAL TILE - R k D 274 Objective: To develop a gypsum acoustical tile using the resin reinforced foam idea* Investigation: Some previous work directed toward the develop ment of a lightweight board confirmed a theory regarding the reinforced foams. The theory is that a foam cell containing some resin or other reinforcing material surrounding the cell will act as an aggregate in a gypsum matrix. This would provide greater strength than normally expected of a foam gypsum struc ture. This theory was confirmed, but the economics of its use in board were not favorable. It was felt that this theory might be applied to a product for which the additional cost could be justified. With the knowledge that acoustical tile, particularly when fire rated, sells for 15 - 25 per sq. ft., some exploratory work was done. Sample 2* x 2* tiles at 15 - 17 Ibs/cu. ft. density were made, using reinforced foam and glass fibers to provide sufficient compressive and transverse strength. Sound absorption tests conducted by an outside laboratory indicate that our product is just about as good acoustically as Armstrong's 2 hour rated Fire-Card tile. A fire test in our small scale furnace indicates that it performs better than either our Firestop 120 or Armstrong's Fire-Card, both of which have 2 hour ratings. The estimated raw material cost, excluding paint, is per square foot for 3/4*' thickness, allowing 25% for waste. This acoustical tile appears to offer good potential and when presented to Sales, it was suggested that we assign a project to proceed with its development. This all occurred during the building renovation, and there was no space to set up for casting full size slabs. As soon as the new building is ready, the necessary foaming, mixing and casting equipment will be installed. In the meantime, our old .Standing Wave equipment for testing sound absorption has been sent out for repair so that it can be used to test the sample tiles which ivill eventually be made. 0. PROTEIN JOINT COMPOUND FORMULATIONS - R & D 275 Objective: To make improvements where advisable or necessary to ouf~JoTnt System products. Investigation: A water retention agen t from the hydrox yethyIcellulose family has been found which offers improved q a si 2. t res and cost savings for our line of Joint System products, iillS product, called N&trosol, will be used as a substitute for Kelsise, which is a Kelp product. In conjunction with this substitution.one of the preservatives will be eliminated . This preservative was necessary because of the degenerative effects the Kelsize The improvements in quality expected are: X. uasier mixing 2. Better working 3. Greater insurance against staining problems which stem from preservatives. 18 SGP 0014897 The savings vary with the formula? butfcased on the last six months* sales. the anticipated annual savings would be 522,300,. Tile savings do not include ready mix in which we have already incorporated Natrosol. A slow changeover to Natrosol in all products is already underway and should be completed by the end of the year* SOUND RATED CONSTRUCTIONS - R D 276 Objective: To conduct a sound test program to establish sound ratings for various partition and floor & ceiling assemblies. Most of this is being done at Donn Products* Ohio Research facilities. Investigation: A rather complete group of sound ratings has been attained with sound transmission Class (STC) values of 5D or better for wood stud, metal stud, and laminated gypsum partition constructions. Other partitions of each type attained ratings in the 45 - 50 STC range. Two new constructions were originated in the course of the testing, i ne is a metal stud partition with an STC of 52 and the other is a 2-|" x 3" gypsum stud partition with an STC of 50. Th'-'se can be promoted as firsts for bestwsll. All of the data recently developed is being put into shape for distribution to the trade and to our sales papple. Some further tests are planned, and tills data will be added at a later date. Our problem in dispersing this information will be to present it in such a manner that it will be under stood by ail. On the basis of some Of the sound ratings obtained, fire tests will be proposed for identical construc tions. It is felt that sound and fire ratings go hand in hand and wherever one is needed, so is the other. DIMENSIONAL CHANCE OF OYPSUM PRODUCTS AT HIOII TEMPERATURES R & D 277 Objective: To measure the dimensional changes which occur m gypsum -products at temperatures up to 2000F. and assess the significance of the data obtained. A Oaertner Dilatoraeter was purchased to make these determinations. Investigation: Our initial work will involve fire rat ed board with-the idea that we may be able to predict what happ ens to this board in an actual fire test. During the calibra tion of the instrument, the element burned out, so it has been returns for repair. COOPERATIVE RESEARCH PROCRAM ul fOUNS-MANVILLR - R :i D 278 Objective: To enter into such cooperative ventures as are considered to be of interest to both companies. The first venture agreed upon is a fire test of Soundike-Firestop installation. SGP 0014898 ~- Investigation: The fire test has been planned and will be heid at OnTio State in the near future. The sound rating of the partition is 45 STC, and if the test is passed,, Bestwall and Johns-Manvilie will be the only ones to have a one hour rating for this partition,, Two tests by the Insulation Board Institute failed to achieve the desired one hour* Other projects were discussed in a meeting with the JohnsManvilie people, but there has been no firm commitment regarding any other cooperative ventures at this time* CONCRETE & BAR JOIST CEILING WITH l/2Tt FIRESTQP - R k 0 27? Objective: To develop a 2 hour rating for this construction using 2^'* of concrete* One and a half hours was attained on the same construction with 2" of concrete* investigation; The A.P*E. is being processed, as Sales has indicated a strong interest in this test. National Gypsum Company already has a 2 hour rating for this construction. 20 * SGP 0014899 SUMMARY The highlie'hts of the Research Acitiviiries for the Dast si;: months have been: lo The introduction of a ready mix joint compound; 2. The development of a water resistant wallboard; 3<> The second successful trial in the manufacturing of wallboard from synthetic gypsum; 4o The 2 and 3 hour fire ratings for columns; 5a The 2-hour rating for the Firestop 120 Ceiling with light & vent openings; 6. The if- hour rating for the concrete ceiling with 1/2" Fi restoo underneath; and 7* The sound ted:data attained thus far for the various partitions tested. Our efforts in certain areas have been retarded, since our shop facilities were removed during the renovation of the building. These facilities will be restored in the new building which is under construction. The installation of certain new equipment, the remodeling of some of the old equipment, and the additional space available will enhance our ability to provide information and conduct project investigations^ Our present'plans for the last half of 1964 call for; 1. The continuation of our fire and sound testing progr 2. Attempts to complete the aggregated textures- new grainboard, and industrial gypsum product developmeu 3* The pursuit of potential cost savings in conjunction with the finer filament glass fiber and new water retention agent for joint system; and 4'0 Embarking on aew projects such as the development of a gypsum acoustical tile. It is also hoped that we can devote a certain amount of time to the search for knowledge, which is not necessarily directed to present objectives but which may serve as a basis for future developments n SGP 0014900