Document 2jq5q9vp6La6vneaLJJd2YpnL

8 Q American Society of Heating and Ventilating Engineers. Guide, 1937 Chapter 27--Fuels and Combustion Table 3. Commercial Standard Fuel Oil Specifications'* A. Detailed Requirements for Domestic Fuel Oils on a new set of specifications providing for definite limits for each grade. When these specifications are adopted, it is expected that the National Board, of Fire Underwriters will retest all burners using oils of the maximum specifications for the grade so that if a burner is approved for a certain Grade of Oil No. 1 Domestic Fuel Oil A light distillate oil for use in burners requir ing a high grade fueL Approx. Btu per Gal.* Flash Min. Point Max. Water and Sediment, Maximum Pour Point.* Maximum Distillation Test Viscosity Maximum 139,000 110 F 165 F 0.05% or legal 16 F 10% point, End point, maximum maximum 420 F 600 F No. 2 Domestic Fuel Oil A medium distil late oil for use in burners re quiring a high grade fuel. 141,000 125 F 190 F or legal 0.05% 15 F 10% point, 90% point, maximum maximum 440 F 620 F grade it will burn any oil meeting the specifications for that particular grade. Several burners adapted to industrial use have recently been listed for automatic operation with No. 5 oil. Usually oils No. 5 or 6 require preheating for proper operation, but where conditions are favorable, No. 5 can be used without the equipment that this entails. There are two reasons for the trend to lower grades of oil. While the lighter oils contain slightly more heat units per pound, the weight per ' gallon increases more rapidly than the decrease in heat units per pound, and oil is bought by the gallon. As a consequence, while a No. 1 oil may contain 139,000 Btu per gallon, oil No. 5 may test 146,000 Btu per gallon, or 6 per cent more. Usually there is a differential of 3 to 4 cents between the No. 1 and No. 5 oils, so that the economy of buying the heavier fuels j I j j| ; j ;j No. 3 Domestic Fuel Oil A distillate fuel oil for use in burners where a low viscosity oil is required. 143,400 150 F 200 F or legal 0.1% 15 F 10% point, 90% point, Saybolt maximum maximum Universal at 100 F 460 F 675 F 55 seconds. is apparent; there remains the economic utilization of the heat content of the heavier oils. The cost of oil fuel is dependent also upon the amount that can be delivered at one time, and the method of delivery. Common practice has split the tank of the truck delivering oils for domestic use into compart- ! [ \ ments of 150 to 500-gal capacity, and these unit dumps are made the basis of price. Where a truck can be connected to a storage-tank fill and B. Detailed Requirements for Industrial Fuel Oils quickly discharge its oil by pump, the price obviously can be less than where a smaller quantity must be drawn off in 5-gal cans and poured. ; Grade of Oil No. 4. Industrial Fuel Oil An oil kdown to the trade as a light fuel oil for use in burners where a low vis cosity industrial fuel oil is required. Approx. Btu per Gal.* Flash Point, Min. Max. Water . AND Sediment, Maximum Pour Point, Maximum Viscosity, Maximum 144,500 150 F. See Note* 1.0% See Note* Saybolt Universal . at 100 F 125 seconds For similar reasons an installation that can be supplied from a tank car on a siding provides for a lower unit fuel cost than one where the oil must be trucked, even in the large trucks holding 2,000 gal or more that are used for distributing the heavier- oils. GAS CLASSIFICATION > No. 5 Industrial Fuel Oil Same as Federal Specifications Board specification for bunker oil "B" for burners adapted to the use of indus trial fuel oil of medium viscosity. 146,000 No. 6 Industrial Fuel Oil Same as Federal Specifications Board 150,000 specification for bunker oil "C" for burners adapted to oil of high viscosity. 150 F ~ 150 F 1.0% Water sediment 1.75% 0.25% Saybolt . Furol at 122 F 100 seconds Saybolt Furol at 122 F 300 seconds ; ? '% 1 Gas is'broadly classified as being either natural or manufactured. Natural gas is a mechanical mixture of several combustible and inert gases rather than a chemical compound. Manufactured gas as dis tributed is usually a combination of certain proportions of gases produced by two or more processes, and is often designated as city gas. When gas is burned a large amount of water vapor is produced as one of the products of combustion. This ordinarily escapes up the chimney, carrying away with it a certain amount of heat. However, when the heat value of gas is determined in an ordinary calorimeter, this water vapor j `Adapted from "Fuel Oils," p. 2, U. S. Department of Commerce, Bureau of Standards, Commercial Standard CS12SS, Washington, 1933. is condensed and the latent heat of vaporization that is given up during the condensation is reported as a portion of the heat value of the gas. j j Government specifications do not give Btu per gallon, but they are noted here for information only. The heat value so determined is termed the gross or higher heat value and `Lower or higher pom points may be specified whenever required by conditions of storage and use. However, these specifications shall not require a pour point less than 0 F under any conditions. this is what is ordinarily meant when the heat value of gas is specified. ^Whenever required, as for example in burners with automatic ignition, a maximum flash point may The heat that is reclaimed by the condensation, of the water vapor l be speafied. However, these specifications shall not require a flash point less than 250 F under any conditions. amounts to about 10 per cent of the total heat value. It is impractical j ; 1 *.0ur. P0^11 l nSay ** .whenever required by conditions of storage and use- However, these specifications shall not require a pour point less than 15 F under any conditions. to utilize the entire higher heat value of the gas in any house-heating appliance, because to do so it would be necessary to cool the products of ! ; 492 493 i li