Document 2jexZL03z98ybkj3yOGb48Lqr
A IRBORNE DUST COUNTS
for
We Ico Manufacturing Company Dallas, Texas
December 28, 1972
Personnel Present: A. H. Golladay
Welco Mfg. Company K. Lasziow Welco Mfg. Company G. L. Dickson Union Carbide Corporation E. J. Kleber Union Carbide Corporation
UNION CARBIDE CORPORATION Mining and Metals Division Niagara Falls, New York
X 4 1 073 1
DESCRIPTION OF PLANT AND TESTS
Tests were conducted October 20, 1972 at Welco Manufacturing Company, Dallas, Texas, manufacturers of tape joint compounds.
Samples were collected from work areas which appeared to be the most likely sources of airborne asbestos. Heavy traffic areas were also monitored. Three main areas of the plant were monitored:
1) Bagging of dry mix 2) Make-up of a I I purpose tape joint compound 3) Make-up of ready-mix Sampling and dust counting were carried out in accordance with OSHA Regulation 1910. 93a, using the Bayer, Zummalde and Brown method for counting asbestos fibers by phase contrast microscopy (Bureau of Occupational Safety and Health, Feb. 1969).
Battery powered air pumps (M.S.A. type) calibrated to 2 liters per minute were used to collect personal breathing zone and environmental samples on millipore membrane filters of 0.8 micron porosity.
Fiber counting was performed on a Leitz microscope utilizing phase contrast illumi nation at 400X and a Patterson Globe and Circle reticle.
Total dust was determined by light field microscopy at 100X.
TEST RESULTS Two figures have been reported for each sample. They are:
1) Total Fiber - Any material 5 microns of longer having an aspect ratio of 3 or greater. Reported as fibers per milliliter.
2) Total Dust - Any fiber or particle present. Reported as million particles per cubic foot.
INTERPRETATION The regulations have been established with the 5 fiber limit on a time-weighted average This essentially means the figures must be arranged to show an employee's average intake of fibers per milliliter on an 8-hour day. For example, the highest reading In the test was 6.7 fibers/ml. If this was the only contact with asbestos that day, the 29-minute sample would be extrapolated to 8 hours, giving a time-weighted average of less than 0.5 fibers/ml.
X410732
SUMMARY OF DUST COUNTS
N.B. No. 1929-60-1
Description
Environmental - 1 ft. from general process bagger
(II min.)
operator, Duo-Cote product. 5-1/2
ft. above floor.
Asbestos Count r ibers/m! r 5/*
Tota 1 Dust
mppcf
3.4 5.4
1929-60-2
Environmental - Background next to "A" powder blender
(14 min.)
prior to dump. 4 ft. from blender tc
electrical panel, 5-1/2 ft. above
floor.
Note: Rather high fiber count probably due
to activity in area, such as bagging
and other powder blenders being used
3.6
8.9
1929-60-3 Environmental - Same position as above, during dump. (29 min.)
6.7
7.2
1929-60-4 Persona 1 (26 min.)
Operator making-up all purpose tape joint compound. Dumping CaC03, Canadian 7TF8 asbestos, starch, cellulose, preservative and mica
4.5
6.8
1929-60-5
Env[ronmenta1 - 6 ft. from "C" ready mix charge hole
(12 min.)
on ready mix tank, during dump.
4.3
9. 1
1929-60-6 Persona 1
Operator dumping CaC03, SG-210,
(12 min.)
Methocel and mica into "C" ready
mix machine.
5.0 9.7
>: 41 0733