Document 2jeOb1poRoDwgRNGLwRnee5o5

i> t OBJECTIVES 1. Progress report on laboratory biodegradation of PCBs. 2. Residue accumulation studies in fish, birds and mammals. 3. To show reduction in less biodegradable PCBs as a result of Monsanto actions on sales and products. 740515 WATER PCB-SD0000055165 MONSANTO PCB ACTIONS 1. Phase-out of PCB sales worldwide in all applications except Dielectrics. 2, Conversion of Dielectric Fluids to more bio degradable PCBs. NEV 027261 740516 WATER PCB-SD0000055166 DEGREE OP BIODEGRADATION OF PCBs Based on data presented: - Transition in biodegradation occurs around penta-/hexa-chlorobiphenyl. - Disappearance of all homologs below hexachlorobiphenyl observed. - Per.ta- and higher TCB determined by specific GLC/MS Test Method. NEV 027262 740517 WATER PCB-SD0000055167 MONSANTO PCB SALES IN U.S.A (Million Pounds) 1969 1970 1972 (Eot.) Dielectrics 37.0 40.5 32.0 All Others 30.0 33.5 - Total 67.O 74.0 32.0 NtV 027263 740518 WATER PCB-SD0000055168 EFFECT OF PHASE-OUT POLICY PCB sales reduced In U. S. A, by 30 to 33 million pounds, or 740519 NfcV 027264 WATER PCB-SD0000055169 PCB PRODUCT CHANGES IN DIELECTRICS CAPACITORS 97$ conversion to Aroclor 1016 TRANSFORMERS Elimination of Aroclor 1260 NtV 0Z72t>5 740520 WATER PCB-SD0000055170 PCBs USED IN CAPACITORS PCB Aroclor 1254 Aroclor 1242 Aroclor 1016 Major Use Period $> PCB (Penta- % PCB (Hexa- chloro- and chloro- and Higher Higher 1930-1952 77.0 23.0 1952-Sept. 1971 9.0- 1.0 Oct. 1971- 1.0 0.01 NEV 0272t>t> 740521 WATER PCB-SD0000055171 Capacitor Fluids Why Convert to Aroclor 1016? 1. 9-fold reduction in PCBs of pentachloro- and higher. 2. 100-fold reduction in PCBs of hexachloro- and higher. 3. Minimum industry testing required. NEV 02726? 740522 WATER PCB-SD0000055172 Capacitor Fluids Y/hat Is The Effect of Aroclor 10l6? u.s. Capacitor Fluid Sales (1972):*/ 20 lbs. If Aroclor Was 1254 12>!2 1015 $ Pentachloroand higher PCBs Would Be* 15,^00,000 pounds 1,800,000 200,000* Hexa chloroand Higher PCBs Would Be* ^,600,000 pounds 200,000 ' 2,000 *Thls does not mean amounts of PCB entering the environment. NEV 027268 740523 WATER PCB-SD0000055173 WHAT IS CAPACITOR FAILURE RATE? Industry Sources Cite : 0.02-0.2$ per Year NEV 027269 740524 WATER PCB-SD0000055174 IP CAPACITOR FAILURE RATE IS 0.2# PER YEAR {VffiST'UKSZJ PCB ESCAPE TO ENVIRONMENT* IS -- All PCB Homologs Penta Chloro- and higher Hexa Chloro- and higher Aroclor 1242 40,000 pounds 3,600 400 Aroclor 1016 40,000 pounds 400 4 ^Assumes U.S. Fluid Sales of 20 M Lb./Year nev OZ72 70 740525 WATER PCB-SD0000055175 PCBs PRESENT IN ASKAREL TRANSFORMER FLUIDS PCBs Pentachloro- and Higher Aroclor 1260 100 Aroclor 1254 77 Aroclor 1242 . 9 PCBs Hexachloroand Higher 70 23 1 Major Use Period 1930-1972 1959- 1968- NEV 0Zld.ll 740526 WATER PCB-SD0000055176 PCB CHANGES IN TRANSFORMER FLUID-APPLICATIONS 1. Aroclor 1260 being phased out now. 2. Aroclor 1016 cannot be used. 3. Incineration of scrap PCBs - 1971* Note: Askarel (PCB) transformers are tightly sealed units. NEV 0Z7172 740527 WATER PCB-SD0000055177 WHAT IS FAILURE RATE IN LIQUID TRANSFORMERS? Industry sources cite: Under 0.2% per year* * All liquid types - mineral oil and PCB. PCB failure could be less since they are inherently safer. NEV 02 72 73 740528 WATER PCB-SD0000055178 IF ASKAREL (PCB) TRANSFORMERS FAIL AT 0.2$/YEAR HOW MUCH PCB IS AFFECTED*? All PCB Homologs . Penta Chloro-and Higher Hexa Chloro-and Higher Aroclor 1254 24,000 lbs. 18,480 5,520 Aroclor 1242 24,000 lbs. 2,160 240 (Estimated PCB transformer fluid sales in U.S. 12 M lb./year) * With incineration facilities available, not all these amounts will enter environment. . NEV 02727** 740529 WATER PCB-SD0000055179 Monsanto's Present Program To Prevent Environmental Pollution By PCBs 1. No more sales world-wide except approved dielectric users. 2. Restrict over 97# capacitor l'luld sales to Aroclor 1016 only. . 3. Restrict PCBs in transformer fluids to Aroclor 1254 and 1242. 4. Continue incineration facilities for scrap PCBs. 5. Encourage dielectric industry through ANSI C-107 to enforce strict environmental control over PCBs. NtV 027275 740530 WATER PCB-SD0000055180