Document 2jZ9m5pqr8DykLwZxZDGbdnGr
V
Interoffice Communication
To DISTRIBUTION
From C. R- Miller
Date January 21, 1980
subject
D-400 REACTOR RELIEF VALVE DISCHARGE
The following are the list of steps that were discussed in this mornings meeting:
The operating procedures were revised immediately after the D-400 release to help determine when a reactor was empty. This procedure needs to be formalized and instructions given to lead operators. - MPB JEB
An investigation into a possible level device to prevent reactor overfilling is to be done by MPB.
3. Expedite delivery of amp meter for D-400. - JAD
4. Investigate relocation of remote camera or revision to swirl piping to allow monitoring by lead operator. - JAD
5. Estimate cost to install amperage recorder^ on each reactor to serve as backup. - JAD
6. Determine quantity of VCM emmission from available data. - RAF
Obtain all data necessary for EPA report. - RAF
f& A detailed investigation and write-up is to be done by CRM, JEB and MPB. Make recommendations of possible solution to prevent reoccurance. ALL
C. R. Miller
jf
DISTRIBUTION: (MPJEB, RAF, JAD, AHS