Document 2jBJamRBn3rr55rVzQ4RKD1gb
+
Therminol 77
Preliminary Technical Data Sheet
DEVELOPMENTAL SYNTHETIC FLUIDS
Therminol 77 is a clear, amber fluid with exceptionally high thermal and oxidative stability. It was especially designed for use as a liquidphase heat transfer fluid at temperatures above 600F. Following are some fluid properties.
Temp. F.
Vapor Pressure (mm Hg)
Viscosity
(cs)
Lbs/Ft-Hr
Density (GMS/cc (Lbs/Gal)
100 210 300 400 500 600 700 800
Temp. F.
100 200 300 400 500 600 700 800
--
0. 27 1. 03 9. 2 44 168 530
181 7. 78
--
1.50 0. 96 0.66 0. 46*
--
505 20. 8
--
3. 74 2. 28 1. 49 0.99
--
1. 152 1. 106
--
1. 029 0.981 0.931 0. 885
--- .
9.60 9. 22
--
8. 5 8 8. 16 7. 76 7. 38
--
Specific Heat (BTU/Lb)
Thermal Conductivity (Cal/cm. UC, sec) (BTU/"F , Ft-Hr)
0.350 0. 385 0. 420 0. 455 0. 495 0.530 0. 565 0. 600
32. 25x10"^ 31. 40xl0"5 30. 50xl0"5 29. 65xl0`5 28. 80xl0'5
--
--
--
0. 0781 0. 0760 0. 0739 0. 0719 0. 0698
--
--
--
^Extrapolation
Temperature, F 100*F 300F 500F 700F
Coefficient of Thermal Expansion, cc/F
0.00034 0. 00037 0. 00049 0. 00062
MONSANTO COMPANY 800 NORTH LINDBERGH BLVD. ST. LOUIS, MO. 63166
TO ASSIST YOU IN THE {VALUATION Of THE AAOVC PRODUCT. Y*F HAV{ OBTAINtO IHC INTORMATlON CON TAINED IN THIS RUIIOIN IR0M LITERATURE SOURCES AND PREllMINARy INVESTIGATION IN OUR OWN
LA00RAIOKIIS WHILE WE IHI'IVI ltlf 'MI1KMA1I0N is ACCUPATE WE ASSUME NO RESPONSIBILITY AND 0ISCLAIM ANY WAEIIIITV INCUHRL0 IN USING THESE DATA OR SUGGESTIONS ONLY QUA|lN[!) TECHNICAL
PERSONNEL SHOULD WORK WITH THIS PRODUCT UNTIL SUBSEQUENT STUUlfS IllSlKY US USE IN YOUR PROD UCTS OR PROCESSES OBVIOUSLY NOTHING IN This BuufllN SHOULD BE CONSIRUID as ftKOMMSN
0085792
WATER PCB-00034807
Refractive Index Pour Point Flash Point Fire Point A. I. T. Thermal Decomposition*
1.6413 +45F 46QF 540F
1115F 800F
Electrical Properties
60 Cycle
1000 Cycle
Dielectric Constant at 100C
3.77
3.54
Power Factor at 100C> % Resistivity, ohm-cm
19. 3 at 100C 29 x 109
1. 21
Oxidation-Corrosion Test (48 hrs. 450F, Air, MIL-L-9236A Method)
% Viscosity Increase at 100F at 210F
2 Metal Weight Loss, mg/cnri
37 13
Cu -1.56 Fe +0. 01 Mg +0. 02 Ag -0. 99 Ti 0. 0 A1 0. 0
Toxicity and Safe Handling:
Appropriate animal toxicity studies indicate that TherminoJ 77 is "practically non-toxic" from the standpoint of accidental swallowing or single massive skin exposures. Irritation potential studies indicate that it should not be irritating to the skin and only slightly irritating to the eyes if there is accidental contact. Animals survived a single four-hour exposure to an atmosphere saturated with vapors at room temperature. It appears that no particular safety precautions are necessary during the handling of this fluid at room temperature.
* Thermal decomposition was determined by the isoteniscope method as described in the "Journal of Chemical and Engineering Data, " January 1961* Volume 6, No. 1. It is defined as the temperature at which dp/dt = 0. 014 mm. Hg per second or 500 mm. Hg per 10 hours.
0065792*01
WATER_PCB-00034808