Document 2j4Ok5YrQEqX96KBx9Xd3Z1dg

REPLACEMENT BAGHOUSE CONSTRUCTION PERMIT APPLICATION VISTA POLYMERS - ABERDEEN PARTICULATE EMISSIONS REFERENCE NUMBER SOURCE 1987 PERMIT APPLICATION AMOUNT (TON/YR) 1989 GUARANTEED AMOUNT WITH NEW BAGHOUSES (TON/YR) 1989 EXPECTED AMOUNT WITH NEW BAGHOUSES (TON/YR) 001 002 003 004 005 006 007 Vinyl Chloride Reaction and Storage Area PVC Drying Area PVC Storage and Handling Area Compound Production Dry Blend Production Plasticizer Product VCM TOTAL 0 123.4 5.54 0.70 2.01 131.65 0 55.7 5.54 0.70 2.01 63.95 0 22.1 5.54 0.70 2.01 30.35 * VAB.0001165149 r 1 DRYER HOMER 002-1 002-2 002-3 002-4 002-5 002-6 002-7 002-8 002-9 TOTAL 1988 BOOBS OPERATED PARTICULATE MISSIORS (LS/IBL) PARTICULATE BCISSiaaS (U/B) 1988 BOOtS OPERATED (LB/BR) 1064.5 0 3430.5 6789.5 7826.5 8043.0 7069.5 8244.5 0 7.0 0 7.0 7.0 7.0 7.0 7.0 .90 0 3.7 0 12.0 23.8 27.4 28.1 24.7 3.7 0 2176 0 6811 8029 6776 8196 7492 7557 0 * - 2.4 2.4 2.4 2.4 2.4 - 123.4 (TOn/TR) 8.2 9.6 8.1 9.8 9.0 - inai BAGBOUSB PARTICULATE MISSIORS BPIC1D (LB/HR) (T08S/TR) 0.6 0.6 0.6 0.6 0.6 - 2.0 2.4 2.0 2.5 2.2 - TOTAL PARTICULATE BMISSIOHS WITH KEH 1ACB0USBS IBCLUDED (TOn/YR) (TOBS/TR) (GQARAETEED) (EXPECTED) 7.6 0 8.2 9.6 8.1 9.8 9.0 3.4 0 7.6 0 2.0 2.4 2.0 2.5 2.2 3.4 0 55.7 22.1 VAB.0001165150 STATE OF MISSISSIPPI DEPARTMENT OF NATURAL RESOURCES BUREAU OF POLLUTION CONTROL P.O. BOX 10385 JACKSON, MISSISSIPPI 39209 For Agency Use FACILITY NUMBER Date Received APPLICATION FOR PERMIT TO CONSTRUCT AND/OR OPERATE AIR EMISSIONS EQUIPMENT - GENERAL FORM Month Day Year APPLICATION FOR: X CONSTRUCTION PERMIT RENEWAL - PLEASE CHECK APPROPRIATE BOX 1 Name, Address, Location, and Telephone Number A* Name Vista Polymers. A Division of Vista Chemical Comoan B. Mailing Address of Applicant .1. Street Address or P.O. Box 2 City Aberdeen 4- Zip Code 39730 P. 0. BOX 91 3. State MS 5. Telephone No. (601) 369-8111 C. Location of Facility .1. Street Highway 25 2 City Aberdeen 3. MS 4. Zip Code 39730. 5. Telephone No. (601) 369-8111 D. If the facility is located outside the City limits, please provide a sketch or description showing the approximate location and attach to this application. 2 SIC Code 2821 3. Number of Employees____2_4_8_______________________ 4. Principal Product PVC- Polyvinyl Chloride 5. Principal Raw Materials VCM - Vinyl Chloride Monomer 6 Principal Process Polymerization 7. M_a__x_im__u_m_ amount of principal product produced or raw material consumed per day 455 million pounds 8. (A) Check here if operation which generates air pollutant emissions occurs all year X or specify the months the operation occurs: _______________________________ (B) Specify how many days per week the operation occurs: 7 (C) Specify how many hours per day the operation occurs: 24 9 If this application is for existing facility permit renewal only, has the facility been modified in any way (including production rate, fuel, and/or raw material changes) during period covered by the Operating Permit Yes No or since 1972? Yes No If Yes, give year(s) in which modification(s) occurred. ALL APPLICATIONS MUST BE SIGNED BY THE APPLICANT. I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate, and that I am the owner or chief corporate officer, or his designated representative, responsible for complying with air pollution control laws and regulations. Frank G. Jeanson Printed Name or Person Signing Environmental Coordinator Title 3-3 Date Application Signed PLEASE COMPLETE FOLLOWING PAGES WHERE APPLICABLE VAB. I A FOR ALL APPLICANTS, WHETHER NEW CONSTRUCTICN, EXISTING FACILITY, OR RENEWL CONTROL EQUIPMENT COVERED UNDER THIS APPLICATION - PLEASE CHECK ALL APPLICABLE AND INDICATE NUMBER OF UNITS. PARTICULATE EMISSIONS CCNTROL EQUIPMENT 1. Cyclone (s) 2. Water Scrubber 3. Baghouse X-5 4. Electrostatic Precipitator GASEOUS EMISSIONS CONTROL EQUIPMENT 1. Water Scrubber 2. Activated Carbon Bed WASTE DISPOSAL SYSTEMS 1. Solid Waste Incinerator 2. Liquid Waste Incinerator 3. Wood or Other Waste Fuel Recovery Boiler 5. Venturi Scrubber 6. Cyclonic Baghouse 7. Cyclonic Scrubber 8. Other 3. Other 4. Gaseous Waste Flare 5. Liquid Waste Flare 6. Other Pneumatic Conveying System Other (please describe) FOR ALL APPLICANTS FUEL BURNING BQUIFfNT (Except for Refuse Disposal) This form has 3 pages; each is a continuation of the equipment information from the page before. Please fill in as completely as possible, listing all fuel burning equipment. Reasons should be given explaining arty data not filled in. PAGE 1 1. Fill in company name and address, plus year for which data is given (if existing facility) at top of page. Use data for most recent calendar year available. 2. Reference Number. Use an identifying number for each boiler, furnace, kiln, etc., and use the same reference number on each of the three pages to identify information for the same unit. 3. Manufacturer and Model Nmfcer. Nameplate data for boiler, furnace, kiln, etc. Waste gas flares and stationary internal combustion engines should also be included on this form. 4. Rated Capacity in Millions of BTU per hour. ** 5. Type of Burner Unit. Use Codes (1*) at bottom of form. If not listed put (11) and specify. 6. Usage. Type of fuel burning equipment. Use codes (2*) at bottom of form. If not listed put (5) and specify. 7 Heat Usage. Percent of heat used for process and percent for space heating. VAB.0001165152 MANUFACTURING PROCESS OPERATIONS PAGE 1 A- UMt 002 PVC Drying Area Capacity 86.7 Quantity Par Hour Quantity Pm Y 1.58xl05 1.39xl09 Number of Emianon Points To Air 9(2) Product Output* Quantity Pm Hour 51,940 4.55x10 NOTES: This is the reference number used on the last permit application for this area (June 23, 1987). Of these 9 emission points, five(5) baghouses will be replaced. *Soocifv Units of Maatura Uod r 001165153 1 11 Number 002 PAGE 3 MANUFACTURING PROCESS OPERATIONS 12 Partteulatss 14.6 lb/hr 64 ton/yr Sulfur Oxides 0 (Mmh (Specify by dieweb composition) for Estimetion (Apsnsy Comtcnti Odvl See Attache^ Calculation Pieces Express Emotions ss Tens per Veer and Pounds per Hour end Identify Units Setup Used. VAB.0001165154 A ADDITIONAL INFORMATION 1. Two copies of construction site plot plan. 2. Two copies of detailed equipment drawings. 3. Two copies of a detailed explanation of the process and control equipment. 4. Two copies of a flow diagram of the of the process or operation showing control devices. SIGNATURES; If for construction, the application must be submitted in duplicate and both copies should also be signed and stamped by an engineer registered in the State of Mississippi. If application is for Existing Facility or Renewal of Permit to Operate, registered engineer's signature not required All sianatures and stamos must be ori photocopies. James L. White 5609 TYPED NAEC & MISSISSIPPI REGISTRATION NUJ-BER GNATURE OF ENGINEER REGISTERED IN MISSISSIPPI Seal of Engineer Registered in Mississippi VAB.0001165155