PCBs--Compliance Is/And Our Responsibility By R. H. Parrish, Member IEEE J. J. Kelly, Member IEEE Transformer Maintenance Institute . Dir. 8. 0. Myers, lac. ... .... ..... Akron, Ohio Abstract - Federal regulations do not rewire the re novel of PCBs lpolychlorinated biphenyls) from service 1A enciosea Industrial and earlier than normal. Many of the estimated 1^0,000 askarei-Hiled ana 35 million oil-filled units In service can and vlll be around for many years to come. sections of TSCA. The first "Disposal end Marking Rule" took effect on April 10, 1970, while the 1979 "PCB Ban Rule" took effect on July 2, 1979. This lat est regulation supercedes completely the 1970 version)* II. Unraveling the EPA PCB Regulation During the state of frustration that the PCB control Issue is in nov, the best route to go is to keep In formed of the latest state and local regulations, and to sake a "reasonable effort" to comply with existing U.S. regulations. At least seven chemical vaste landfills for non-liquid PCBs have been approved by the EPA (Environmental Protection Agency). On the other hand, until such time u EPA approved PCB liquid incineration becomes feasible--in terms of distance end backlog--don't panic! Hold on to the liquid la EPA approved containers, store In an EPA approved manner, and inspect weekly until incineration becomes practical. Don't contract for shipment to some facility that gyr have an approved incinerator as you may be subject to spill liability. I. Introduction Federal EFA regulation* do not require the removal of PCBs from service In totally enclosed Industrial and utility transformers earlier than normal. Therefore, many of the estismited 11*0,000 aakarel-filled end five million oil-filled power and 30 million distribution units in service can and vlll be around for many ' years to eome.l But 0.8. EPA regulations do control the use, maint enance, handling, labeling, storage, and disposal of polychlorinated biphenyls (PCBs) within those trans formers I large power capacitors. Even though PCB has been the wet listed item in U.8. regulations, it has not been totally banned nor is this anticipated in the future.2 PCBs, known gsnerlcally as "askartl", have been used*' for 30 years for cooling and insulating electrical equipment in situation* where high fire resistance was required. Another plus was PCB ehsalcal stability. But this sums characteristic of persistence that made PCBs useful for industrial purposes ha* made* them harm ful, especially their cumulative effect on-tb* food chain from plankton (the simplest plant or anInca) to fish, birds, and so on thru to the hvauui species.3 A 1973 attempt at voluntary control vaa unsuccessful. Therefore, subsequent stages have involved government al regulations. The first step vae the adoption of the Toxic Substances Control Act (Public Lav #9U-1*69 known as TSCA) which vent Into effect January 1, 1977. The Intent of TSCA has been to protect In a reasonable and prudent manner the public health and the environ ment from further contamination from toxic chemical substances and mixtures. PCB Is only on* of tho chem icals to bs regulated. Congress also mandated that detailed regulations be published to Implement certain The law is clear -- choosing to keep PCB transformers in service requires proper identification; choosing to dispose of units requires the same Identification plus proper storage end disposal procedures. Either option requires accurate recordkeeping. A. Definitions Notable among the PCB associated terminology defined In Table I is a PCB item. A PCB Item is any PCB associated thing that deliberately or unintentionally contains or has as a part of it any PCB or PCBs at a concentration of $0 parts per million or more (0.005 per cent on e dry weight basis) and is therefor* subject to EPA regulations. Both askarsl and PCB are rarely found on a transformer nameplate. Many people are more familiar with one of the Insulating fluid tradenames, as Pyranol*, Insrteen*, AroclorB, and so on. As a matter of record, PCB was invented In 1929 by Swann Chemical, later bought out by Monsanto Chemical. The late Dr. P. M. Clark patent ed its application for uss as an insulating fluid for the General Electric Co. in 1931.3 Someone has illustrated the meaning of quantity In parts per million (PPM) using this analogy: One (l) part In a million is comparable to on* (1) minute in 1.9 years! The definition of PCB mixture includes transformer oil and other liquid coolents that hart been inadver tently contaminated. Major transformer manufacturers have acknowledged that "some oil-filled transformer* may contain varying concentrations of PCB." In this regard It is illegal to deliberately dilute PCBs. This recludea toppingpit a mineral-oil filled transformer fbat's contaminated vita rew. At the same time, ITTCBBrrTyTIksoo xt level has dropped over the passage of time below the transformer core, the addition of mlnaral oil as a maintenance step only should not violate the intent of the PCB regulation. This paper will first cover changes that took placs In the 1979 rule end also oentldar other PCB related legislation -- both existing and forthcoming. Current PCB regulations apply to all persons who manu facture, process, distribute la commerce, use, or dis pose of PCBs. Our focus will be upon those who usa end dispose of PCBs. B. In Service Units ' - .. Existing totally enclosed transformers can continue in definitely in service. Proper labeling, recordkeeping, end voluntary inspection are the only necessary guide lines. However, free breathers may be phased out by 190$. These 0 S. D. livers, Inc. 19Y9 1 M0NS 000148 TDN PCB, PCBS PCB Transformer PCB Contaminated Transformer** . PCB Article PCB Container PCB Article Container PCB Equipment PCB Item Table 1 Envlronmental Protection Agency PCB Regulation Terminology* DBTNITIOH Any ehealcal substance containing only a biphenyl molecule that has been chlorinated to varying degrees or any combination of substances, which .contain such substance. -1--------1- EXAMPLES PCB liquids and non-liquids. Any transformer that contains 500 ppm PCB or grsatsr. Aakartl filled, rvtre filled unit, or mloeraloil filled unit an found from testing. Any transforaer that contains 50 ppa or greatsr of PCB but less than 500 ppa PCB. Typical oll-fllled transformer or PCB retrefilled unit. . Any manufactured Item, other than a PCB container that contains PCBs and whose surface(s) has been in direct contact with PCBs. Large high or low voltage capacitors, transfoiasrs, PCB cooled meters. Any device used to contain PCBs, or PCB articles, and whose surfaos(s) has been In contact with PCBs. Bottle, barrel, Anns or box. Any device used to contain PCB articles or PCB equipment, and whose surfaos(s) has not been In contact with PCBs. Shipping or storsg* carton for capacitors. Any manufactured item other than a PCB container or PCB article container that contains a PCB article or other PCB equipment. Industrial television receiver, alcrowavs oven, fluorescent light ing fixture. Any PCB article, PCB article container, PCB container or PCB equipment, that deliberately or unintentionally eontalns or has a part of it aay PCB or PCBa at a concentration of 50 parte per million (ppa) or more. Aroclorjj, Inerteen^, Pyranol , contaalnated tran*former, (mineral) oil, or coolants retrofilled to transformers forasrly containing PCB. Boh PCB Transforaer - Any trensforaer that contains less than 50 ppa PCB - tern not formally dsflnsd lo this regulation. 9-MUST H LftL4P V _______________ Requirements for Labeling PCB-Related Items* {For PCB Items of 50 ppm or more only) K trmfonwr f.'ur unltaSSOO ?ic onlv) Large FOB high-voltage capacitor or capacitors mouat>|d la i protected location euch as on a pole, struc ture, or behind a fence, only one label need be posted on the pole, structure or fenoe. A telephone number Is sufficient owner contact Identification. Other FOB artlclee-PCB cooled electric aotors, PCB hydraulic equipment and systems, PCB heat-transfer equipment and systems not associated with transforaer and capacitor cooling. FOB equipment (containing a PCB transforaer or PCB larse hlah-voltaae capacitor). PCB storage areas, PCB containers, and PCB article containers. PCB transport vshiclss (motor vehicle or railcar) carrying more than L5 kg (99.fa lbs) of PCB's. *8ee Figure 1 for required label fornat LASCUNC, *V**\ if <-SOOff*w A.\9i 2 Figure 1 TSCA requires that PCB iteas be Identified at spe cifically prescribed with the largest PCB nark practical for a PCB item. When a PCB article or PCB equipaent la too taall to aecoaodate the smallest permissible size of Hark M^, Mark Mg aay be used. Detailed requirements for siss, color and durability arc siren in the Federal Beslster. Part VI , P.31556. CAUTION CONTAINS PCBs IPehwMsrlnsisd Blphsnvlil US. I_______ Afincy AmeMimnieOCPR Til. Ssr O'wwtf Mrtenitmmft mmm mi *mtm U4. IM one*. Iwwwe* wAi>iall,iiil n` !... 1me*eUS.Csmi OtrtfS eeesMseoi HONS 000149 [CAUTION i CONTAINS j PCBs | | (PNvcMsriflftse Biehsftvhl | | FOR PROPER DISPOSAL | I INFORMATION CONTACT I | UJ. ENVIRONMENTAL j | FROTSCTION AGENCY j MS units consist of railroad transferaera, primarily, with few industrial unit* involved. 1. Transformer Identification indicated that very little mineral oil dielectric fluid will b contaminated vlth PCS beyond 503 ppm. EPA thus anticipates that most transferrer ovn-r/ operators will make such an assumption. Under the latest PCB regulation, all items listed In Table XX should now display the appropriate PCB label* (Figure 1). .... *. , 2. Requirements for PCB Recordkeeping a. Who Must Comply Bines July 2, 19TB* an inventory must be kept concern ing the status of your PCB items. The requirements apply to eaeh facility owner or operator who has on his premises! . One or more PCB transformers and/or 2. Schedule over a period of time, as the budget ptrmits. a one tine PCB analyeli test on each mineral . ,11-rfn.i trtUiWH or unknown rt concentra tion bqginnTngwiththe noet crlticai-ualta -- by location (near a waterway^ and by disposition (near the end of life expectancy). First, thos* units tested and found below the 50 ppm PCB standard would thus be exempt from all disposal requirements and any PCB spill issoclsted problems. Secondly, testing would serve ae a preventive maintenance tool. Since there is evidence that over 100 ppm PCB in mineral oil reduces the impulse strength of oil,testing would indicate suspect units,9 . $0 cr more PCB large high or low voltage capacitors (Set Table XIX) and/or . At laaat b5 kilograms (99.W lbs) of PCBs. These records will form ths basis for a required an nual document prepared by eaeh facility. It should bs avsilable on July 1, 19T9 and each aucceedlng July 1 thereafter. For multiplant companies in scat ters! locations, one record for the entire corporation could bs maintained at a central location. Current law requires that records are to be maintained in ths individual companies' own file, subject to re quest of copies or on-sits EPA inspection upon the preeeatetlon of appropriate credentials, along vlth written notice of the facility to be lnepected. b. What Data Required q Total weight in kllogreme of PCBt end PCB Items In containers including identification of container contents, such as liquids or capacitors (total weight means excluding the weight of the containers). I Total number of PCB transformers and total weight in kilograms of any PCB liquids contained in the transformer. * Total number of PCB isrgs high or low voltage capa citors. As Table I shows, a distinction has now been made be tween PCB transformers, those containing 500 or more ppm, and PCB contaminated units, those containing be tween 50 and b99 ppm, and non-PCB transformers, those with lass than 50 ppm PCB. Those units that contain lss_than 500 war do not requlM IIBIi.1, However, special Identification of "PCB contaminated wits" (50-1*99 ppm) may be the best way to assure special treatment. Obviously, such action necessitates scheduled one-time PCB analysis, but it facilitates compliance with the lav. Thus, these two suggested steps provide: . Immediate identification for ongoing inspection of units and recordkeeping. . Minimise future disposal costs. . Meet probable testing prerequisite prior to any con tracted transformer maintenance work. Consider this typical laboratory data (about 1000 samples of mineral oil): ` " PCB Concentration Percentage of Samples Tested g location of PCB item. 1. > b99 ppm 10* Use nameplate information to determine PCB weight re quirements. Your annual reporta must be kept for at*. least five (5) years after a facility ceaeea to own or operate PCB related items In the prescribed quantities. Failure to keep proper records le a violation of the law. Civil penalty of up to 125,000 could be Imposed for violation of T8CA| eaeh day the violation con tinues Is consldtred a separate violation. c. How Accpetable Records Oenerated (To test or not to test!) Testing for PCB concentration in transformer mineral 1 oil is not required in the latest PCB ruling. There fore, consider tvo^^ossiblsogtioijs. (l.e, do not test ). Ihj^es^thereii^ -> reason to bafc lv has more than 500 r-------- f|)- **" *n e EPA Information has 2. 50 - 1*99 ppm 3. < 50 b. 0 ppm (Pure mineral 0il)> . 2b* 265 b0* Two out of every three units tested will likely con tain less than 50 ppm PCB. As transformer oils are tested for PCB-content, based on the 50 ppm EPA standard for PCB item, units can then be properly labeled, where benericlsl. 3. Voluntary Periodic Inspection Consider all possible precautions that can prevent s spill. a. Establish a checklist for periodic inspections. 1. Insure that units are structurally sound. Labels for PCB items containing 50 **99 ppn are not required before October 1, 1979* 3 MGNS 000150 ?. Cheek for fgaket leak* (cortn, hand-hole or buehlnge). equipment. It will probably be several years before sufficient incineration capacity will be available. 3. Cheek sampling valves and other fitting*. it. Check pumps and cooling radiators for leaks. b. Establish a eoaslstaat schedule for such laspection (monthly minimum). e, Consider diking and curbing for units nsar water- ST--------------------------------------------------------- - d. Begin to establish a spill prevention Plan - a .rl*l of QPTitlom proc.aur.. to b. follov.a In ths psrforwanot of a PCa activity.(operating or teatlns apparatus-L.Q ~ . Basin to Prepare a control and countermeasure plan-to ba followed when a release of PCBs occurs at"a use or servicing operation^ It. Maintenance Bautin. --l-l.--g lull t.itliu. Mid o forth),by th ovntr or nut.lj. cnntrictar of all-unit. la paraltt.ri. Ifow.v.r. . contractor p.rfomlnc IriMtomr [.rrlclne n r.a'ilr.d to obtain . iltllil nnu.l EFA authorisation. Until eueh time as EPA approved PCB liquid incinera tion becomes feasible, hang loosel Even now, prac tical logistics -- distance and backlog -- make Immediate incineration difficult. Therefore, hold on to the liquid in ZPA-DOT approved containers. Store properly and Inspect it weekly until disposal is practical. Fortunately, the EPA recognites the limitations of technical and economic feasibility to incinerate 11 PCB Item.. Tliertfor. til, l.v umlti cno.l r.r PCB solids,contaminated liquids (fn-ioo -- ^ frf approved chemical vasts landfills or high efficiency chemical boilers. At least summit! UHHTm waste landfills are now "open". The boiler rating must bs at least 50 million 8TU per hour and must meet certain stack gas characteristics. Since disposal in landfill* will not result In PCB destruction, other new approaches now in the prototype stage may become available; e.g., the use of micro wave radiation. PCB trimforwri. notbir, can b. p.ncn.ntly Jispoi.a of in a chemical wastelandflll If all these conditions are met: " " *1 PCB contaminated transformers (50-1*99 ppm PCB) may be topped off, refilled or rebuilt vlth dielectric fluids containing laaa than $00 ppm PCB. Existing askarel filled units may ba topped off vlth PCB die lectric fluid. However transformer repair. Including rewinding of colls,lsnotpemltted on unit* of 500 or ore ppm PCB. But, PCB transformers retro- filled to PCB contaminated units may then be rebuilt. { The unit must be drained of all free-flowing liquid, and the liquid munt be treated in the manner pre scribed for PCB liquids in Teble III. <*. It must then be filled vlth a suitable solvent (such as kerosene, xylene, toluene) In which PCBs are readily soluble. (Some of these liquids are also hazardous.) . During the next five years, EPA vlU be examining the use of substitute insulating fluids in older units to dstsrmlne the feasibility of phasing out all usa of PCBs. . C. Out-of-Strvlce Units All out-of-servlce PCB Items (Table II) must also be properly labeled, whether spare unite or those await ing disposal. The solvent must be left in the unit for et least 18 hours, and the unit must then be drained thor oughly. e The drained solvent -- which la now a PCB Item -- must bs treated in the manner prescribed for PCB liquids in Table III. vf* jto *> Any PCB contaminated transformer (50-1*99 ppm PCB) requires only bhese steps: ~ Sines April lB, 19T0, PCB liquids ( 500 ppm) must be disposed of In only an EPA approved incinerator. All non-liquid PCBs can be disposed of in an EPA approved chemical vasts landfill. g Transformer drained of all free flowing liquid. f The dielectric fluid may be disposed of in a chemical waste landfill or high efficiency boiler. | The various PCB items suit be labeled and stored at " * | ivamrlMd In T,bl III for PC lta cont.lnlna aore | uni*** otherwise stated. A transformer declared ae a spare can remain In a substation. If the unit Is declared for disposal, then It must be moved to an EPA approved storage faolllty pending appropriate disposal. ' 1. Permanent Disposal The only known way to permanently remove PCBe from the environment Is high temperature (at lea:<t 120QC) In-, dneratlon with proper dwell time. EPA regulations ro longer permit storage of PCB liquid* 539 ppm. How ever, at present only two approved incinerators are open.* Several other companies have applied. One was approv ed, but local ordlna-.* ah it the facility down. Bschus* of this delay in obtaining permits and delivery of q Drained transformer carcass may then be disposed of in a municipal landfill or sold for salvage. 2. Temporary Storage for Disposal Storage for disposal means temporary storage of PCBs that have been designated for disposal. 'JjblelV lists the provisions for tsmporary storage of Eiir* articles, equipment or container^. When storage Is desired prior to disposal, contamin ated PCB liquids (50-1*99 ppm) and non-liquid PCBs must be stored in.JUL.EPA approved.storage facility. An EPA approved storage facility has been defined as a roofed, walled and diked enclosure with an imper meable floor, such as Portland cement concrete or steel. Ho storage facility may be loeated at a site which Is below the 100 year flood water elevation (that is, % flood that has an average frequency of occurrence in the order of once in 100 years). Thsre- *Tht first Incinerator still any not be EPA approved until Septonber 1, 19T9. )i HONS 000151 Table III Permanent Disposal or Dong Tern Storage of PCB'e Pending Disposal (ForPCB ltsme of 50 ppm or mare, unless otherwise stated) Disposal neana the Intentional or accidental discharging or ether completion or terninatien of the useful life of an object or substance* -- __--__ . - . . TERN DISPOSAL PROVISIONS PCI liquid* (> 500 pja) Disposal In EPA approved hl-temp. incinerator. No storage penitted. PCB contaminated aineral oil dielectric fluid {50--h99 ppm) Disposal in EPA approved hl-temp. incinerator; EPA approved ehemical vaate landfill or an high efficiency boiler.* PCB contaminated vasts liquid (50-1*99 ppm) such as hydrau lic or heat transfer fluids. Disposal In EPA approved hl-temp. incinerator; EPA approved chemical vasts landfill or an EPA approved high efficiency boiler.* Non-liquid PCBs; contam inated toil* rags* or other debris froe uncontrolled spill ltrash, trees, lumber). Disposal In EPA approved hl-temp. Incinerator; or EPA approved chemical vasts landfill.* However, Items may be considered to have been disposed of if they vere deposited in a chemical vasts Isndflll before */l6/T8. Non-liquid PCB vaate; dredge spoils, municipal sevagetreatnent sludges. Disposal In EPA approved hl-temp. incinerator. EPA approved chemical waste landfill, or by other EPA approved method.* The digging up of debris snd other items disposed of in e landfill prior to A/18/78 is not required but the Intent of the rule is that you can't add to an existing site and let it sit. PCB transformers (> 500 ppm) Disposal in EPA approved hl-temp. incinerator or EPA approved chemical waste landfill, folloving procedure given in article text.* PCB contaminated trans former (50-**99 ppm) Disposal In municipal landfill or sold for salvage folloving procedure given in article text. ' PCB large high or low voltage capacitors (more than 3 pounds or 1 quart of PCB liquid) , Disposal in EPA approved hl-temp. incinerator; disposal permitted until 1/1/60 in EPA approved chemical waste landfill.* ' PCB small capacitors (less than 3 pounds or 1 quart of PCB liquid) Capacitors owned by capacitor manufacturers or PCB article manufacturers (production quality-control rejects, etc.) to be disposed of In hl-temp. Incinerator; disposal permitted in EPA approved chemical waste landfill until 1/1/80. All other small capacitors may be disposed of as muncipal solid vasts. PCB hydraullo machine (dle-castlng) Disposal as municipal solid waste or sold for salvage following procedures given in artlclq. text. Other PCB articles ' PCB container ( 500 ppm) Disposal In EPA approved hl-temp Incinerator, EPA approved chemical waits landfill; following thorough draining snd proper disposal of PCB liquid.* i Disposal in EPA approved hl-temp. incinerator or EPA approved chemical waste landfill (folloving temporary storage at tn EPA approved facility until-properly drained and PCB liquid has been properly disposed of)** PCB container (50-1*99 ppm) Disposal as municipal solid waste, folloving proper draining and disposal of PCB contaminated liquid. Lone tens storage of this itea is permitted In IXA-DOT approved container:) and/or located In an EPA-approvod facility until l/l/BU. MONS Q0G152 5 r Table IV Temporary Storage of PCB Items Pending Disposal XTD4 ' STORAGE PROVISIONS* Non-leaking PCB article or equipment. . Storage in temporary area up to 30 days instead of standard EPA dtflnsd ,, . facility. Check weekly for leaks. Long term storage required after 30 ' days In roofed and diked enclosure with Impermeable floor until l/i/Ok. Check at least once every 30 days for leaks.** Non-leaking structurally undamaged large high voltage PCB capacitor , PCB contan- inated tranaforner Long term storage on skids next to an EPA defined storage facility until 1/1/83. This makes a facility lsnediately available If a leak should develop. Reason: In case of delay in the construction of proper incineration facilities or for new capacitors to be used at a construction site; check weekly for leaks. Leaking PCB articles and eouloment Stored in non-leaking SPA-DOT approved containers for up to 30 days (contalninc sufficient sorbent materials to absorb lloulds PCBs) PCB containers containing nonllquld PCBs (soil, rags) or liould PCB* (5M99 ppm).*" Storage in temporary ares up to 30 days instead of standard EPA defined facility, provided a spill prevention control and counter measure plan oreoared. Lsak, leakage or leaking means any Instance In which a PCB article, container or equipment has any PCB on any portion of its exterior surface. Date PCB item rsnored froa service noted on the PCB itea. It is no longer permissible to store drums of liquid PCBs ( 500 PPM). fore. Immediately contact your regional office of U.S. Oeologloal Survey for a hydrological map that docu ments whether or not your present site is adequate or should be relocated. 3. Pecordheeplng In conjunction with disposal requlreaents, the trana- fontr oxn.r/op.rhtormult m th. follnvlM tott XflOlJlt-llinU*1 mpowL dnaumentlnx the Status of PCB ltsas slatsd for disposal: t Data removed froa service. Date placed Into storage pending disposal. Ignoring or attempting to conceal a leak, a spill, or other uncontrolled discharge of PCB is sngaglng In un - lawful disposal and-subject to criminal prosecution. 1. Preventive Action Weekly inspection for all items temporarily stored In non-BTA approved nr mi i.Hh 30 <Uy mlnl- -- ioia.ctlop for All Itm it.nr.ii In p EPi .pprnv.d facility. Exp.rl.nc. has already ahovn that In.ptc- tlon for leakage should be made more often than every 30 days -- even with new PCB containers. In antici pation of possible rules for hasardoua spills, spill prevention Is the only sure way to treat a spill sit uation. Data placed In transport for disposal. 2. Corrective Action 4 Total walght (in kilograms) and identification of PCBs in PCB containers. a Total number of PCB transformers and total weight (in kilograms) of any PCBs contalnsd In tha trana~ formers. 4 Total number of large high or low-voltage PCB eapaeltore. 4 Location and name of owner of Initial storage or disposal facility (Bill of lading). It Is permissible to determine the weight of PCB by calculation (using valid assumptions of ths density of the PCB chemical substance or mixture) if the volume of the container or transformer is known. Failure to keep these proper records la a civil vio lation of the PCB law. D. PCB Spills 1 Spills and other uncontrolled discharges of liquid PCBs are defined as disposal; therefore, proper procedures must be undertaken. a. In the Event of Minor PCB Leakage Proper actions to be taken conslet of: . Transfer leaking containers and articles, and their contents, to properly marked, nonleaking containers. . Uce sorbents such as imbiber beade to clean up any epilled or leaked material Immediately. . Dispose of (or store for future disposal) residue as ladlcatsd in Tabls III or IV. b. In the Event of a Major Spill A PCB spill is any discharge of sufficient magnitude to give reason to suspect that It has produced, at any point In the surrounding soil, gravel, sludge, fill, rubble, or other land-baaed substances, a PCB contam ination level. excaedine 50 PBm. The following " cures must be taken in the event of a spill. w. Transfer leaking containers and articles, and their contents to properly marked, nonleakln* containers. _, Use sorbents to clean up any spilled or leaked mate rial immediately. 6 MONS 000X53 Dispose of (or store) residue at indicated in Tablo III or IV. , Conduct tests, using EPA-approved sampling techni ques and laboratory methods, to detenslne if PCB conctntration in toil, ate., excatdt $0 ppa. _. Decontaminate area* containing aora than 50 ppa.of PCB in accordanca with EPA regulations. Several companies hava alraady aatabliahad their own tptcial taaat that art cant out to handla PCB spills and elaan up. Contraotad elaanup aarvieaa eartainly eould alto bt an option. IZI. EPA Approved Methodt of Tatting for PCB Concentration Implerasntation of the foregoing guidelinat requires firat a procedure to readily identify tranefonaera containing PCB mixtures. Although tatting for PCB content in oil by electron capture gat chromatogrdpby (OC) la the meet prevalent laboratory method,? the Beilateln field teat can be a preliminary teat to detect PCBa at a level of five (5) per cent (50,000 ppn)& or greater. Very fev unite are thle groealy contaminated. Since evidence hae thovn that more than 100 ppm PCB In mineral oil tendt to reduce the Impulse strength of oil, testing vould Indicate tutptet units. The technology to remove PCBe from mineral oil It being actively developed to assure the transformers max imum design lightning strike capability.9 IV. Other PCB Assoclatad federal and 8tata Lavs Implementation of the foregoing present and projected regulations In no way precludes compliance under other regulatory rulings. In fact the intent of the various statutes Is integrating all facets of the PCB problem yet without doing so at crosi-purpodee. The tvo most important rCB associated docinents are (1) The Resource Conservation and Recovery Act (RCRAP.L. #9**--3B0, 1976), Involving hatardous vasts manage ment and (9) Section 311 of the Federal Water Pollu tion Control Aot (FWPCA-P.L. #92-500, 1972). Even though detailed rules of RCRA may not be pub lished until mid-1980 and Section 311 la under a court Injunction declaring It void, existing state lavs indicate that the prudent vay to go vould be to prepare even nov for inevitable U.S. regulations. In " * one form or another.10 Suggested steps that should be taken Include: 1. Inventory of PCB Items - In service units,-spares or units pending disposal (Required under current PCB rule). . a. One-time PCB In oil analysis (best vay to assure proper transformer treatment). 3. Tracing of PCB wastes (manifest system). Several states already require a manifest system ("credle-to-grave" paperwork) for off-slte dis posal. The manifest is defined as the form used for Identifying the quantity, composition, origin, routing, and destination of PCB liquids and solids, during transit from the point of generetion to the point of storage or disposal. Therefore, begin a bound logbook containing this data (compliance under RCRA and/or state lav). I*. Assigned clear responalbilitleell a. Make sure that specific technical and legal people are Involved in day-to-day decisions on PCB storage and disposal. b. Inform other company personnel as to the latest information on how to make a "reasonable effort" to comply with all regulations. 5. Transportation for disposal.*2 a. Train shipping personnel. 1) Proper packaging and labelingi Per EPA-Pepartment of Transportation (DOT) specified containers for PCB liquids or non liquid PCBe. Mineral oil dielectric fluids of unknown concentration may be shipped via > United Parvel Service (UPS), but ag&arel liquid should be shipped with a Class TTpoison GSel. Biertl'Ml. IBAlfil lannul be sliluued by UPS. 2) Response control and countermeasure plan when PCB release occurs. b. Provide truck drivers with complete bill of lading and current response information in case of anaccldental spill. Zncluds phone numbers of'slte destination point and reg4 ionel EPA. Start reporting now harmful * quantity discharges near waterways to the Rational Response Center: (800) l2k-8802 (under FVPCA, Section 311). 4 6. Keeping abreast of state legislation - transit of hatardous wastes; both home state and thoee thru vhioh shipping liksly will go. 7. Renew of ofr site disposal agreements. Wrlttsn contract should spell out in detail what you aa PCB generator will do and what dispose contractor will do. When do title, ownership and risks transfer from the PCB generator to dispose con tractor? 8. CAUTION: You cannot assume PCBe are being proper ly disposed of. You should follow thru - make regular checks of waste contractor and routine on site inspections. Evaluate the facility in terms of competence, staffing, permits, problem history and general suitability,for PCB disposal. Has fa cility received U.S., 8tate end local approval for dispoalTl3 < V. Other Options Available to Owners of PCB Transformers Retrofllling or replacing a PCB transformer are also alternatives, in addition to retaining PCB units. (Xp Retrofill Askarel-Fllled Unit With Hon-PCB Alternative Coolant1** '' ~ Pit residual mixture should be tested at lent an nually lpreferably more frequently) to determine Its exact PCB content , aT It'vill fluciiate as It seeks equillbrum. IJ.lng r.troflll rroc.dur.. only on. tin. .Ill prob.blr 7 HONS 000154 r.uit lfl .eontmn.tta triaifamr.tlitt Haula' r to t. mm . unit In til 9. E. 1. Raab, 0. 11, 197V. , Aucust 3, 1978 am* April' ...nr Therefore, retrof111 In actuality ftroflm and/or subsequent Iflterina with Mttmid carbon. 10a. R. S. Glaublnger, "A Guide to the Resource Con servation and Recovery Act, Chemical foalneerlna -- Magazine, McOraw-tftll, New- York,' R.Y., January 29, 1979, pp 79-81. Even then the unit still might be treated aa a PCS Hem, depending upon concentration; hovever, the po tential eeonoaic liability becomes conelderably leas b. Richard Sobtl (Allied Chemical Corporation), "How Industry Can Prepare for RCRA," Ibid, pp. 82-85. ------- than the coat of decontamination In the event of a c. T. H. Maugh II, "Toxic Waite Disposal a Crowing pill Involving a concentrated PCB. Problem." Science.American Association for ths Disposal of both existing PCB liquid and flushing liquid requires Incineration. So long as disposal Advancement of Science (AAAS), Volume 20k, 25 May 1979, p. 819. 11. V. D. Beebe (Potomac Electric Power Company) thru Incineration remains a problem* the beat lo cation for PCBa la the transformer Itself. "Asksrel/Polyehlorinsted Biphenyl (PCB) Pro cedures," Minutes of the k6th Annual International Hovever* vhen sufficient facilities do become approved, Conference of Doble Clients, 1979, Doble Engi neering Co.; Watertown, Mass., Section 10B-1. rctrofill may be the primary vehlclt In preparing for 12. Ken Snow (Flying Tiger Line) "Shipping Hatardou* ultimata disposal of PCB transformers and thus phasing out of askarel-fllled transformers. Material," Chemical Engineering Magazine, McOrsw Hill, New Yort.N.Y., November b, 19T6, pp 102 B. Replace the Aaharel-Pllled Unit 108 (Discussion of Dept, of Transportation DOT regulations.) . 13. Allan Hall, "Waste sites may be major liability If a transformer la located near a drainage canal, for CPI" Chemical Week. May 2, 1979, p 18. stream* or vatervay the only safe option la to replace Ik. T. OVJell A J. J. Kelly, "Silicone RetrofUl of the unit with one containing a non-FCB coolant, gas Askarel Transformers',' Minutes of the 13th dielectric or an air-cooled, dry unit. Electrical/Electronic Insulation Conference, Chicago, IL Sept. 29, 1977. p. 167. location* use and nameplate capacity required would 15a. John Walsh, "EPA and Toxic Substance* Law: Deal determine this final choice. ing with Uncertainty,'1 Science. Volume 202, 10 November 1976, p 396. VI. Conclusion b. Bruce H. Ames (Professor of Biochemistry, U. of Much criticism has been directed toward the expense of California, Berkeley),"Identifying Environmental EPA regulation. It is a fact that tha long term effect Chemicals Causing Mutations and Cancar."Science. of PCB on the food chain may not be known for years.15 Vol. 20k, 11 May 1979, p 587. Yet public support for costly environmental protection 16. Luther J. Carter, "Public Support for Environ remains strong.1* That's because of the high coat of mental Protection Remains Strong," Science. Volume the alternative -- not regulating.!7 203, 12 January 1979, p 15k. IT. Nicholas A. Ashford (Associated Professor of In any event, while the laaue of PCB control continues Technology A Policy, Massachusetts Institute or In a state of frustration* the beat route to go la to Technology), "A pies for a new kind of realism," keep Informed of the latest state and local regulations The Hew York Times. Business Section, December and to maka a "reasonable effort" to comply with exist 17, 1978. ing fedtrai regulations (required marking, record- kteplng,voluntary Inspection, and suggested one-time PCB analysis of transformer mineral oils). VII. References 1. Microeconomic Impacts of the Proposed PCB Ban Reg ulations. Vtrsar. Inc. (EPA *5pO/6-77-35. May 1978. p.7,37-38. 2. D. 2. Hutchinson, American Electric Power Service Corporation "Regulatory 8tatus of the PCB Sub stitutes," 19T9 Vinter Meeting, Hew York,Raw York? IEEE Power Engineering Society, February 6, 1979, pp 6-7. 3. Edvard L. Raab (Retired, General Electric Co.,Pitts field, Meat.) In conversation hold at Transformer Consultants, Dlv. S. D. Myers, Inc. Akron,-Ohio, August 3, 1978, and April 11, 1979. . k, R. K. Parrish A J. J. Kelly "Warning! TSCA May be Hazardous to Your Professional Health," Plant EnalneerlngR. May 11, 1979, p. 133. The 1978 law la found In ths federal Register. Februery 17, 1978, Vol. 1*3* Ho. 31*, Port V, pp 7150-T16V. Tho 197, "PCB Ban" Rule published May 31, 1979, Is located In the Federal Reelster. Vol. tlo. 106, Part VI, pp 315lk-31558. 3. E. L. Raab,_op. clt., August 3, 1978. 6. Steps d A e may be required under Section 311 of the Water Control Act. Some states already have sueh 7. 0. Hutiinger, S. Safe, V. Zltko, The Chemistry of PCB's.CRC Prees, Cleveland, Ohio 197k, pp 207, 210-112. 6. U.S. Navy NEPSS {Naval Environmental Protection Support Berv. information Bulletin,! July 1978. HONS 000155 8