Electrical Hazards The receiver slots are arranged to prevent reversal of polarity if the grounding plug is moved from one side of the duplex receptacle to the other Each opening is different in size or shape to prevent accidental misalign ment of either the polanzed or standard blades Misalignment could energize the grounding equipment so that the current would enter the frame of the tool For complete continuity of the ground cir cuit, three-conductor extension cables with properly attached polanzed plugs and recep tacles should be available These extensions can then be used to continue the ground path when tool cables are too short to reach the grounding receptacle Fig 33-5 --Standard receptacle and plug recom mended by the National Electrical Manufacturers Association The receptacle is designed to receive a plug having three blades --a U-shaped or round grounding blade with two standard parallel polar ized blades This type of fixture also permits use of the nonpolarized standard plug receptacles The workman neglected to attach the ground wire of his adapter and, when the tool case became charged, he was electrocuted Since an early lack of standardization in the design of plugs and receptacles and m their application led to confusion, ASI Standard C73, Dimensions of Caps, Plugs, and Recep tacles, was set up This standard specifies that a receptacle similar in size and shape to the ordinary two-hole type be designed to re ceive a plug having three blades, a U-shaped or round grounding blade and two standard parallel polarizing blades (Fig 33-5) A receptacle of this type will permit use of the polarized or nonpolarized standard plug for such tools as soldering irons, timers, test ing equipment, and others that do not require grounding 988 Maintenance of grounds. Only qualified persons should install or repair receptacles and plugs They should make sure that the green-covered ground wire is attached to the hexagonal green binding screw so that the frame will not be energized by improper wir ing Good maintenance will ensure a complete electrical ground path from the portable equipment through the line cord, plug, recep tacle, grounding system, and ground clamp, terminating m a good earth ground conductor Portable ground-testing instruments, such as a megger ground tester (not the same as the megger insulation tester), ground ohmer, groundometer, or a low-range ohmmeter, provide the most convenient and satisfactory means for measuring the resistances of ground They are self-contained and easv to operate, and resistance is indicated directly on the instrument's dial When a program of ground testing is planned, use of one or more of these instru ments is recommended, since the whole op eration can be handled by one man A test lamp is not recommended for checking resist ances of grounds because it may not light when the ground resistances are higher than those specified in the codes Driven ground rods should be given spe cial tests because of variance in resistance resulting from soil conditions They should be checked for corrosion, damage, and separ ation of the ground wire from the clamp Continuity of the circuit can be checked with a simple low-voltage test unit having an indicating light bulb (Fig 33-6) This