Document 2RZEEp2o8d88rNK6e2zv2aXR6
William R. Bradley and-Associates
ENVIRONMENTAL HEALTH CONSULTANTS 18 GREEN STREET NEWARK, N. J. 07102
201 622-4246
December 15# 1966
Sprayed Mineral Fiber Mfg. Assoc., Suite 2300 One Wall Street New York, New York 10005
Inc.
Attentions Technical Committee
Res Environmental Health Investigation
A study was made of airbom dusts in the# work area of operators spraying mineral^ fiber in the two new building' construction sites. Dust counts from microscopic examina tion of eight air samples were made. The dust counts include mineral wool particles and asbestos fiber of respirable size only. These dust particles are five microns in diameter or smaller and represent dusts that may penetrate deeply into lung tissue and that may be retained therein.
The first three dust samples were collected at a north ern New Jersey location that was completely enclosed. The skilled operator used a long, approximately twenty foot pipe, in order to reach high ceiling structures from the floor.
The first sample was collected in a sheltered comer of the outside walkway having a large overhead roof. The second and third samples were collected indoors.
The second series of five samples was collected at a midtown New York City construction site. Sample number four was collected on the platform at the nose level of the spray operator. The operator had his hand directly on the nozzle and was standing on a platform within a few feet of his work. The operator did not appear to be as skilled as the first operator# causing overspray# underspray and backspray. The location was a generally open area where the wind could blow
through and carry visible spray a considerable distance.. Samples one# three and four were collected at about one
foot distance from the operators head and nose level and represent operators potential exposure. It was noted that operators wore approved type respirators but that operators helpers or foreman did not. It was noted that the employee dumping bags into the feed hopper wore a respirator but that his supervisor in performing the same operation did not.
3
Analysis of Dust Samples
SamDle Number
Location New Jersey
Millions Particles per Cubic Ft. of Air
1. Outdoors in comer of shel tered walkway while spraying twenty foot high roof from
.ground area.
4.5
2. Inside enclosed building. Large open area. Sample collected six foot from hopper of product feed machine.
4.0
3. Spraying comer of enclosed
7.0
room, upper wall and ceiling,
operator at floor level, spray
area fifteen to twenty feet,
above floor.
New York Citv
o *
H
4.
On platform two to three feet
26.0
from nozzle and two to sfx feet
from area of application.
5.
Sample collected at head level
9.0
sixty feet from spray operator.
.6 Sample collected at head level
thirty feet from spray operator.
7.
Sample collected at head level
10.0
17 feet from spray operator.
.8
Sample collected two floors below
2.7
area of spray application and in
small enclosed service room.
-4
At the New Jersey location air temperature was 46F. and
relative humidity was 96% At the New York location air temp
erature was 42F. and the relative humidity was 96%.
Summary
The recommended threshold limit value for asbestos dust is five million particles per cubic feet of air. Inert or nuisance dusts have a recossnended threshold level of fifty million particles per cubic feet of air. Inert dusts have
less than 1% free silica. The threshold level value applies
to eight hours daily exposure, day in and da^ out, without damage to lung tissue likely'to result in illness.
Threshold limit values are exceeded under the conditions of sampling and spray application and show concern for use of respiratory protection and for employee health maintenance. Steps taken to reduce minus five mipron dust particles in the product are considered to be worthwhile.
WR3/dm
16^ 1? flnJUti
William R. Bradley