Document 2RZ1BvOOX40646wd0KnDQj7Zp

Boilers, Steel Lookout Boiler & Mfg. Company -- Successors to the HEGGIE SIMPLEX BOILER CO. Joliet. Illinois Chattanooga, Tennessee RCQ. U. S. PAT. OFFICE Represented in Principal Cities REG. U S. FAT. OFFICE . STANDARD SERIES LOOKOUT HEGGIE-SIMPLEX STEEL HEATING BOILERS 15-Lb. Steam Pressure Steel Plate Welded Joints A.S.M.E. Construction 30-Lb. Water Pressure JL Steam Boiler Assembly Smokeless Arch Type fFootr Burning Any Solid Fuel STANDARD SERIES SPECIFICATIONS Direct Draft Type Mechanical Fired Type Smokeless Direct Mechanical Arch Type Draft Type Fired Type Jl t Sii-b isz*s 53 Zo .SX S .sx l'o_e 2 'lljp? fcil l!Uvi fs aN Ocn Oco i* icjr S3 53-8g S*-S Lrs"s e if jc .*cq; Ir^ IJ V. I 3*5 tn< 134A 134C 134K 140A MOB I40D S40E 147A 147B 147C 152A 152B 152C 152D 157A 157C 157D 163A 163B 163C 163D 170A 170B 170C I7SA 1780 I84A 184C 184E 184G 1690 334A 2110 334C 2530 334E 1690] 734A 2)10 734C 2530 734E 2060 2570 3080 121 151 181 3110 340A 3500 340B 3110 740A 3500 740B 3770 4250 222 250 4120 340D 4120 740D 5000 294 4500 340E 5000 347A 4500 740E 5000 747A 5470 6080 322 358 5490; 347B 5960 347C 5490 747B 5960 747C 6660 7240 392 426 6500 352A 6500 752A 7890 464 7000, 352B 7000 752B 8500 500 7520 352C 7520 752C 9130 537 8040 352D 8040 752D 9760 574 9100 357A 9100 757A 11050 110420] 357C 10420 757C 12650 650 744 110701 357D 11070 757D 13450 791 12500 363A 12500 763A 15180 894 ,13360 363B 13360 763B 16220 954 114200 363C 14200 763C 17240 1014 15000 363D 15000 763D 18220 1074 16020 370A 16020 770A 19450 1144 ,17020 370B 17020 770B 20670 1216 18030 370C 18030 770C 21900 1288 20000 378A 20000 778A 24290 1429 22390 378C [22390 778C 27180 1599 25000 384A 25000 784A 30360 1786 28010 384C 28010 784C 34020 2001 31010 384E 31010 784E 37660 2215 34010 384G 340101 784G I 41290 2429 | 8.2 10.5 10.4 12.4 13.7 13.7 13.7 14.7 16.5 16.5 18.6 18.6 20.7 20.7 22.9 25.2 25.2 28.1 28.1 28.1 30.6 31.0 31.0 33.9 35.0 38.2 36.0 41.3 44.8 44.6 67% 79V, 911/4 80% 86% 98% 104% 101% 107% 113% 103% 109% 115% 21% 115% *27% *33% 123% 129% 135% 141% 129% BJB US'/. 147% Ml'/. !Sj* 177% 67% 9.8| 171 62>/4 12.3, 214 62% 14.8 257 69% 13.9 280 69% 15.3 308 69% 18.1 364 69% 19.5 392 22.3 476 24.0 514 72% 25.8 552 78% 23.3 551 nvi 25.1 596] 78% 26.9 641 78% 28.8 686 81% 130.9 753 81% 35.1 858 81% 37.2| 910 93 34.9, 953 93 37.1 1014 93 [39.31 1076 93 41.5 1137 96% 43.6 1269 96% 146.2 1347 96% 48.8 1423, 106% 47.9 1524 106% 53.9 175! 113 152.9 1831 113 58.9 20421 113 64.9 2255 113 70.9 24671 3 To determine S.H.B.I. Ratings of Hot Water Heating Boilere, add 60 per cent to corresponding steam boiler rating. 922 83 ,?ar Icq of 66 78 89 92 98 110 116 125 133 ^ 141 136 144 152 160 167 184 193 197 206 215 224 230 240 250 258 281 291 314 337 361 Lookout Boiler & Mfg. Co. Boilers, Steel RESIDENCE SERIES LOOKOUT HEGGIE-SIMPLEX STEEL HEATING BOILERS Steel Plate Welded Joints 15-Lb. Steam Working Pressure A.S.M.E. Construction 30-Lb. Water Working Pressure Direct Draft Type for Hand Firing any Solid Fuel Mechanical Fired Type for Oil, Gas, or Stoker Steam Boiler AteemUy mti Jacket p,, Buminy Any Solid Fuel RESIDENCE SERIES (Double Pass--2 In. Tubes) SPECIFICATIONS Jacketed and without Jacket Direct Draft Type Mechanical Fired Type Direct Draft Type Mechanical Fired Type Catalog Number Steam Boiler Steam Rating Sq. F t. (S.H.B.I.) 1 Catalog Number Steam Boiler Steam Rating i Sq. Ft. (S .R B .l.) Heating Surface Sq. Ft. (S.H.B.I.) Grate Area Square Feet Width of Boiler, Inches Length of Boiler. Overall. Inches Height of Bate, Inches Height of Boiler on Bate. Inches Height of Water Line, on Bate, Inches Steam Liberating Area. Sq. Ft. Water Capacity Full, Gallons Steam Space Cu. Ft. Size of Steam Outlet, Inches Size of Return Opening, Inches Size of Water Heater Openings Diameter of Stack, Inches 'J h 2SJ1 2SJ2 2SJ3 2SJ4 2SJ5 2SJ6 2SJ7 2SJ8 2SJ9 2SJ10 370 2SCJ1 510 2SCJ2 670 2SCJ3 800 2SCJ4 950 2SCJ5 11IH 2SCJ6 1300 2SCJ7 1480 2SCJ8 167(1 2SCJ9 1830 2SCJI0 540 32 7 6 68C 4(1 3.5 8711 48 4.3 9711 57 5.1 1160 M 5.4 134(1 79 6.0 1580 93 7.0 1800 106 7.8 197(1 116 7.9 2230 131 9.0 24 34% 12 56 48 3.8 37 1.8 3 3 '% 10 30 24 m 12 56 48 4.8 48 2.3 3 3 % 10 30 24 45% 12 56 48 5.8 60 2.8 3 3 >% 10 30 24 53% 12 56 48 6.8 71 3.3 3 3 i% 10 30 27 47% 12 65 55% 6.6 103 3.8 4 4 % 12 40 27 53% 12 65 55% 7.7 122 4.5 4 4 % 12 40 27 WU 12 65 55% 8.9 143 5.1 4 4 1% 12 40 27 66% 12 65 55% 10.0 163 5.8 4 4 % 12 40 30 60% 12 72 61 10.1 175 6.7 5 5 1% 14 50 30 66% 12 72 61 11.3 199 7.6 5 5 i% 14 50 To determine 8.H.B.I. Ratings of Hot Water Heating Boilers, add 60 per cent to corresponding steam boiler ratings. In addition to the STANDARD SERIES and RESIDENCE SERIES of Steel Heating Boilers, we make the following: HIGH FIREBOX SERIES--Mechanical Fired Type. Specifications given in Bulletin No. 112. P, 0. SERIES PORTABLE FIRE BOX BOILERS--(Single Pass)--Down-draft Wafer-Grate Type--Direct Draft Type- Mechanical Fired Type. Specifications given in Bulletin No. 117. F.P.O. SERIES PORTABLE FIREBOX BOILERS--(Double Pass)--Down-draft Water-Grate Type--Direct Draft Type--Mechanical Fired Type. Specifications given in Bulletin No. 118. REFUSE BURNING WATER HEATERS--Direct Draft Type. Specifications given in Bulletin No. 119 923