Document 2RZ1BvOOX40646wd0KnDQj7Zp
Boilers, Steel
Lookout Boiler & Mfg. Company
-- Successors to the
HEGGIE SIMPLEX BOILER CO.
Joliet. Illinois
Chattanooga, Tennessee
RCQ. U. S. PAT. OFFICE
Represented in Principal Cities
REG. U S. FAT. OFFICE
. STANDARD SERIES LOOKOUT HEGGIE-SIMPLEX STEEL HEATING BOILERS
15-Lb. Steam Pressure
Steel Plate
Welded Joints
A.S.M.E. Construction
30-Lb. Water Pressure
JL
Steam Boiler Assembly Smokeless Arch Type
fFootr Burning Any Solid Fuel STANDARD SERIES SPECIFICATIONS
Direct Draft Type
Mechanical Fired Type
Smokeless
Direct
Mechanical
Arch Type Draft Type Fired Type
Jl t
Sii-b
isz*s
53
Zo
.SX
S .sx
l'o_e 2
'lljp? fcil
l!Uvi
fs aN Ocn
Oco
i*
icjr
S3 53-8g S*-S
Lrs"s
e if
jc
.*cq; Ir^ IJ
V. I 3*5
tn<
134A 134C
134K 140A MOB I40D S40E 147A 147B
147C 152A 152B 152C 152D 157A 157C 157D 163A 163B 163C 163D 170A 170B 170C I7SA 1780 I84A 184C 184E 184G
1690 334A 2110 334C 2530 334E
1690] 734A 2)10 734C 2530 734E
2060
2570 3080
121
151 181
3110 340A 3500 340B
3110 740A 3500 740B
3770 4250
222 250
4120 340D 4120 740D 5000 294
4500 340E 5000 347A
4500 740E 5000 747A
5470 6080
322 358
5490; 347B 5960 347C
5490 747B 5960 747C
6660 7240
392 426
6500 352A 6500 752A 7890 464
7000, 352B 7000 752B 8500 500
7520 352C 7520 752C 9130 537
8040 352D 8040 752D 9760 574
9100 357A 9100 757A 11050 110420] 357C 10420 757C 12650
650 744
110701 357D 11070 757D 13450 791
12500 363A 12500 763A 15180 894
,13360 363B 13360 763B 16220 954
114200 363C 14200 763C 17240 1014
15000 363D 15000 763D 18220 1074
16020 370A 16020 770A 19450 1144
,17020 370B 17020 770B 20670 1216
18030 370C 18030 770C 21900 1288
20000 378A 20000 778A 24290 1429
22390 378C [22390 778C 27180 1599
25000 384A 25000 784A 30360 1786
28010 384C 28010 784C 34020 2001
31010 384E 31010 784E 37660 2215 34010 384G 340101 784G I 41290 2429 |
8.2 10.5 10.4 12.4
13.7
13.7 13.7
14.7 16.5
16.5 18.6 18.6 20.7
20.7 22.9
25.2
25.2 28.1
28.1 28.1
30.6 31.0
31.0 33.9
35.0 38.2
36.0 41.3
44.8 44.6
67% 79V, 911/4 80% 86% 98% 104% 101% 107% 113% 103% 109%
115% 21% 115% *27% *33% 123% 129%
135% 141% 129%
BJB
US'/.
147% Ml'/.
!Sj*
177%
67% 9.8| 171 62>/4 12.3, 214 62% 14.8 257 69% 13.9 280 69% 15.3 308 69% 18.1 364 69% 19.5 392
22.3 476 24.0 514 72% 25.8 552 78% 23.3 551 nvi 25.1 596] 78% 26.9 641 78% 28.8 686 81% 130.9 753 81% 35.1 858 81% 37.2| 910 93 34.9, 953 93 37.1 1014 93 [39.31 1076 93 41.5 1137 96% 43.6 1269 96% 146.2 1347 96% 48.8 1423, 106% 47.9 1524 106% 53.9 175! 113 152.9 1831 113 58.9 20421 113 64.9 2255 113 70.9 24671
3
To determine S.H.B.I. Ratings of Hot Water Heating Boilere, add 60 per cent to corresponding steam boiler rating.
922
83
,?ar Icq of
66 78 89
92 98 110 116 125 133 ^ 141 136 144 152 160 167 184 193 197 206 215 224 230 240 250 258 281 291 314 337 361
Lookout Boiler & Mfg. Co.
Boilers, Steel
RESIDENCE SERIES LOOKOUT HEGGIE-SIMPLEX STEEL HEATING BOILERS
Steel Plate
Welded Joints
15-Lb. Steam Working Pressure
A.S.M.E. Construction 30-Lb. Water Working Pressure
Direct Draft Type for Hand Firing any Solid Fuel Mechanical Fired Type for Oil, Gas, or Stoker
Steam Boiler AteemUy mti Jacket
p,, Buminy Any Solid Fuel
RESIDENCE SERIES (Double Pass--2 In. Tubes) SPECIFICATIONS
Jacketed and without Jacket
Direct Draft Type
Mechanical Fired Type
Direct Draft Type
Mechanical Fired Type
Catalog Number Steam Boiler Steam Rating
Sq. F t. (S.H.B.I.) 1
Catalog Number Steam Boiler Steam Rating i
Sq. Ft. (S .R B .l.) Heating Surface Sq. Ft. (S.H.B.I.) Grate Area
Square Feet Width of Boiler, Inches Length of Boiler. Overall. Inches Height of Bate, Inches Height of Boiler on Bate. Inches Height of Water Line, on Bate, Inches Steam Liberating Area. Sq. Ft. Water Capacity Full, Gallons Steam Space Cu. Ft. Size of Steam Outlet, Inches Size of Return Opening, Inches Size of Water Heater Openings Diameter of Stack, Inches
'J h
2SJ1 2SJ2
2SJ3 2SJ4 2SJ5 2SJ6
2SJ7 2SJ8
2SJ9 2SJ10
370 2SCJ1 510 2SCJ2 670 2SCJ3 800 2SCJ4
950 2SCJ5 11IH 2SCJ6 1300 2SCJ7 1480 2SCJ8 167(1 2SCJ9
1830 2SCJI0
540 32 7 6 68C 4(1 3.5 8711 48 4.3 9711 57 5.1 1160 M 5.4
134(1 79 6.0 1580 93 7.0 1800 106 7.8
197(1 116 7.9 2230 131 9.0
24 34% 12 56 48 3.8 37 1.8 3 3 '% 10 30 24 m 12 56 48 4.8 48 2.3 3 3 % 10 30 24 45% 12 56 48 5.8 60 2.8 3 3 >% 10 30 24 53% 12 56 48 6.8 71 3.3 3 3 i% 10 30 27 47% 12 65 55% 6.6 103 3.8 4 4 % 12 40 27 53% 12 65 55% 7.7 122 4.5 4 4 % 12 40 27 WU 12 65 55% 8.9 143 5.1 4 4 1% 12 40 27 66% 12 65 55% 10.0 163 5.8 4 4 % 12 40 30 60% 12 72 61 10.1 175 6.7 5 5 1% 14 50 30 66% 12 72 61 11.3 199 7.6 5 5 i% 14 50
To determine 8.H.B.I. Ratings of Hot Water Heating Boilers, add 60 per cent to corresponding steam boiler ratings.
In addition to the STANDARD SERIES and RESIDENCE SERIES of Steel Heating Boilers, we make the following: HIGH FIREBOX SERIES--Mechanical Fired Type. Specifications given in Bulletin No. 112. P, 0. SERIES PORTABLE FIRE BOX BOILERS--(Single Pass)--Down-draft Wafer-Grate Type--Direct Draft Type-
Mechanical Fired Type. Specifications given in Bulletin No. 117. F.P.O. SERIES PORTABLE FIREBOX BOILERS--(Double Pass)--Down-draft Water-Grate Type--Direct Draft
Type--Mechanical Fired Type. Specifications given in Bulletin No. 118. REFUSE BURNING WATER HEATERS--Direct Draft Type. Specifications given in Bulletin No. 119
923