American Society of Heating and Ventilating Engineers Guide, 1929 Table 1. Corresponding Pressures and Velocities of Dry Air at 70 Deg. and 29.92 In. Barometer Inches of Water 0.05 0.10 0.20 0.25 0.30 0.40 0.43 0.50 0.60 0.70 0.75 0.80 0.87 0.90 1.00 1.25 1.30 1.50 1.73 1.75 2.00 2.17 2.25 2.50 2.60 2.75 3.00 3.03 3.25 3.47 3.50 3.75 3.90 4.00 4.25 4.34 4.50 4.75 Ounces per Sq. In. 0.0289 0.577 0.1154 0.1443 0.1730 0.2308 0.2500 0.2884 0.3460 0.4037 0.4326 0.4614 0.5000 0.5190 0.5768 0.7209 0.7500 0.8650 1.0000 1.0092 1.1535 1.2500 1.2975 1.4418 1.5000 1.5860 1.7300 1.7500 1.8740 2.0000 2.0185 2.1630 . 2.2500 2.3070 2.4510 2.5000 2.5950 2.7395 Velocity Ft. per Min. 896 1266 1791 2003 2193 2533 2637 2832 3102 3351 3468 3582 3729 3800 4005 4478 4566 4905 5273 5298 5664 5895 6007 6332 6457 6641 6937 6976 7220 7457 7492 7756 7910 8010 8256 . 8337 8496 8729 Inches of Water 4.77 5.00 5.20 5.50 6.00 6.07 6:50 6.94 7.00 7.50 7.80 8.00 8.67 9.00 9.54 10.00 10.40 11.00 11.27 12.00 12.14 13.00 13.87 .14.00 15.00 15.61 16.00 17.00 17.34 18.00 19.00 19.07 20.00 20.81 22.54 24.28 26.01 27.74 Ounces per Sq. In. 2.750 2.884 3.000 3.172 3.460 3.500 3.749 4.000 4.037 4.326 4.500 4.614 5.000 5.190 5.500 5.768 6.000 6.344 6.500 6.921 7.000 7.497 -8.000 8.074 8.650 9.000 9.227 9.805 10.000 10.380 10.960 11.000 11.535 12.000 13.000 14.000 15.000 16.000 Velocity . Ft. per Min. 8745 8943 9134 9392 9810 9864 10210 10545 10595 10968 11187 11328 11792 12015 12367 12665 12915 13282 13445 13875 13950 14440 14913 14985 15510 15820 16020 16513 16675 16990 17456 17488 17910 18265 19012 19730 20120 21090 Corresponding Velocity for Dry Air at Various Pressures and Temperatures and 29.92 In. Barometer \ PreSSURB Inches 0.25 0.5 0.75 1.00 1.25 1.50 1.75 2.00 2.25 Ounces 0.1443 0.2884 0.4326 0:5768 0.7209 0.8650 1.0092 1.1535 1.2975 60 60 70 1965 2778 . 3402 3929 4393 4812 5197 5556 5892 1986 2808 3439 3971. 4440 4864 5254. 5616 5956 2003 2832 3468 4005 4478 4905 5298 5664 6007 100 2059 2911 3565 4117 4602 5042 5446 5822 6174 150 2149 3038 3720 4296 4804 5262 5683 6076 6443 300 2399 3391 4153 4796 5362 5874 6344 6783 7193 600 2696 3812 4668 5390 6027 6602 7131 7624 8085 650 2895 4095 5020 5795 6470 7100 7655 8195 8690 422 Chapter XXVIII--Air Duct Design and Construction Standard velocities of air in public buildings are as follows: 1. Through the outside air intakes 1000 ft. per minute. 2. Through connections to and from heater 1000 to 1200 ft. per minute. 3. Through the main discharge duct from 900 to 1200 ft. per minute. 4. In branch ducts 600 to 1000 and vertical flues 400 to 800 ft. per minute: 5. In registers or grilles 200 to 400 ft. per minute depending upon the size and location. : 6. If diffusers of proper design are used, 25 per cent higher air velocities may be permitted. It is customary in proportioning ducts for heating and ventilating work to follow either of two methods: 1. Arbitrarily select sizes from assumed velocities, depending upon velocity of air at fan outlet. 2. Determining the velocity which will give an assumed resistance within fan capacity at noiseless operating speed. By decreasing the velocity in main duct as air is delivered through branch outlets: (1) more uniform air delivery through outlets is accom plished, (2) friction in smaller pipes is reduced, (3) portion of velocity head is converted into static pressure. FRICTION LOSSES IN PIPES . The two greatest losses in duct systems are dynamic losses and friction losses. The former are chiefly caused by changes in direction or in velocity of air flow and are expressed as pressure in inches of water gage-- see Table 1. The loss of head caused by friction, which is numerically equal to the pressure required to._ maintain a given velocity, may be most easily expressed by the modification of the Fanning formula, when, dealing with round pipe and standard air (70 deg. fahr. -- 29.92 Bar). h=f L / V> CD \4005) When dealing with rectangular ducts and standard air, where Vh =f L / + 6\ h = L_ (a+b\ ( V \ 2ab ) v C \ 2ab J V.4005/ k -- loss of head in inches of water. V -- velocity of air in feet per minute. L = length of pipe. \ D = diameter of pipe. a = one side of rectangular duct. All in feet or inches. b -- other side of rectangular duct, j f = coefficient of friction,which varies from about 0.01 to 0.03. C *= length of pipe in diameters for one head loss. For most calculations it will simplify, matters to consider that the value of f and C vary only with the nature of the pipe surface. Thus, C may be taken as about 60 for smooth piping, such as used in planing mill exhaust systems; C = 50 for ordinary galvanized iron heating and ventilating 423