Document 2RL1pZgdELKXyeK79kd6qMdVN

8 CHAPTER 1 1957 Guide Resistor, Electric: A material used to produce heat by passing an electric current through it. Return, Dry: A return pipe in a steam heating system which carries both water of condensation and air. The dry return is above the level of the water line in the boiler in a gravity system. (See Return, Wei.) Return, Wet: That part of a return main of a steam heating system which is filled with water of condensation. The wet return usually is below the level of the water line in the boiler, although not necessarily so. (See Return, Dry.) Return Mains: Pipes or conduits which return the heating or cooling npedium from the heat transfer unit to the source of heat or refrigeration. Reversed-Retum System: A system in which the heating or cooling medium from several heat transfer units is returned along paths arranged so that all circuits com posing the system or composing a major sub-division of it are of practically equal Sabin: A unit of equivalent sound absorption equal to the equivalent absorption of one square foot of a surface of unit absorptivity (i.e., of one square foot of BUrface which absorbs all incident sound energy). Saturation: The condition for cc-existence in stable equilibrium of a vapor and liquid or a vapor and solid phase of the same substance. Example: Steam over the water from which it is being generated. Saturation, Degree of: The ratio of the weight of water vapor associated with a pound of dry air to the weight of water vapor associated with a pound of dry air saturated at the same temperature. Smoke: An air suspension (aerosol) of particles, usually but not necessarily solid, often originating in a solid nucleus, formed from combustion or sublimation. Also defined as carbon or soot particles less than 0.1 micron in size which result from the incomplete combustion of carbonaceous materials such as coal, oil, tar, and tobacco. Smokeless Arch: An inverted baffle placed in an up-draft furnace toward the rear to aid in mixing the gases of combustion, and thereby to reduce the smoke produced. Solar Constant: The solar intensity incident on a normal surface located outside the earth's atmosphere at a distance from the sun equal to the mean distance between the earth and the sun. Its value is 415, 445, or 430 Btu per (hr) (sq ft) as the July, January, or mean value, respectively. At sea level in July the solar intensity value is about 300 Btu per (sq ft) (hr) since about 28 percent is absorbed in the earth's at mosphere. Sorbent: A material which extracts one or moie substances present in an atmos phere or mixture of gases or liquids with which it is in contact, due to an affinity for such substances. Sorption: Adsorption or absorption. Split System: A system in which the heating is accomplished by means of radia tors or convectors supplemented by mechanical circulation of air (heated or un heated) from a central point. Ventilation may be provided by the same system. Square Foot of Heating Snrface (Equivalent): This term is synonymous with Equivalent Direct Radiation (EDR). Stack Height: The height of a gravity convector between the bottom of the heat ing unit and the top of the outlet opening. Steam: Water in the vapor phase. Dry Saturated Steam is steam at the satura tion temperature corresponding to the pressure, and containing no water in suspen sion. Wet Saturated Steam is steam at the saturation temperature corresponding to the pressure, and containing water particles in suspension. Superheated Steam is steam at a temperature higher than the saturation temperature corresponding to the pressure. Steam Heating System: A heating system in which heat is transferred from the boiler or other source of heat to the heating units by means of steam at, above, or below atmospheric pressure. Steam Trap: A device for allowing the passage of condensate, or air and con densate, and preventing the passage of steam. Supply Mains: The pipes through which the heating medium Sows from the boiler or source of supply to the run-outs and risers leading to the heating units. Surface, Heating: The exterior surface of a heating unit. Extended heating sur face (or extended surface): Heating surface consisting of fins, pins or ribs which re ceive heat by conduction from the prime surface. Prime Surface: Heating surface having the heating medium on one side and air (or extended surface) on the other. (See also Boiler Heating Surface.) Terminology 9 Temperature: The thermal state of matter with reference to its tendency to com.municate heat to matter in contact with it. If no heat flows upon contact, there is no difference in temperature. Temperature, Absolute: Temperature expressed in degrees above absolute zero. Temperature, Dew-Point: The temperature at which the condensation of water vapor in a space begins for a given state of humidity and pressure as the temperature of the vapor is reduced. The temperature corresponding to saturation (100 percent relative humidity) for a given absolute humidity at constant pressure. Temperature, Dry-Bulb: The temperature of a gas or mixture of gases indicated by an accurate thermometer after correction for radiation. Temperature, Effective: An arbitrary index which combines into a single value the effect of temperature, humidity, and air movement on the sensation of warmth or cold felt by the human body. The numerical value is that of the temperature of still, saturated air which would induce an identical sensation. Temperature, Mean Radiant (MRT): The temperature of a uniform black en closure in which a solid body or occupant would exchange the same amount of radi ant heat as in the existing nonuniform environment. Temperature Scales. Three temperature scales, Centigrade, Fahrenheit, and Reaumur, derive their degree values by dividing the difference between the ice point and steam points of water as follows: Centigrade 100, Fahrenheit 180, and Reaumur 80. Only the first two are important in the United States. The value of a Fahren heit degree is therefore 5/9 of a Centigrade degree. The Kelvin scale, sometimes called Centigrade absolute, has its zero point at the loyrest attainable temperature 273.16 Centigrade degrees below the triple-point temperature of water and exactly 273.15 below the zero of the Centigrade scale. The Rankine scale, sometimes called Fahrenheit absolute, has its zero at the lowest attainable temperature 459.688 Fahrenheit degrees below the triple-point temperature of water and exactly 459.67 F deg below the zero of the Fahrenheit scale. degT. o convert Centigrade to Kelvin temperature (generally designated K) add 273.15 To convert Fahrenheit to Rankine temperature (generally designated R) add 459.67 deg. Temperature, Wet-Bulb: Thermodynamic wet-bulb temperature is the tempera ture at which liquid or solid water, by evaporating into air, can bring the air to satu ration" adiabatically at the same temperature. Wet-bulb temperature (without qualification) is the temperature indicated by a wet-bulb psychrometer constructed and used according to specifications. (ASMS Power Test Codes, Series 1932, In struments and Apparatus, Part 18.) Therm: A quantity of heat equivalent to 100,000 Btu. Thermodynamics, Laws of: Two laws upon which rest the classical theory of thermodynamics. These laws have been stated in many different, but equivalent ways. The First Law: (1) When work is expended in generating heat, the quantity of heat produced is proportional to the work expended; and conversely, when heat is employed in the performance of work, the quantity of heat which disappears is pro portional to the work done. (Joule)* (G.P.)*>; (2) If a system is caused to change Irom an initial state to a final state by adiabatic means only, the work done is the ssime for all adiabatic paths connecting the two states. (Zemansky); (3) In any power cycle or refrigeration cycle the net heat absorbed by the working substance is exactly equal to the net work done. The Second Law: (1) It is impossible for a self acting machine, unaided by any external agency, to convey heat from a body of lower to one of higher temperature. (Clausius) (G.P.); (2) It is impossible to derive mechanical work from heat taken from a body unless there is available a body of lower temperature into which the residue not so used may be discharged (Kelvin) (G-P); (3) It is impossible to construct an engine that, operating in a cycle, will pro duce no effect other than the extraction of heat from a reservoir and the performance of an equivalent amount of work (Zemansky). Thermostat: An instrument which responds to changes in temperature, and which directly or indirectly controls temperature. Transmittance, Thermal: The time rate of heat flow, from the fluid on the wann Bide to the fluid on the cold side, per (square foot) (degree temperature difference be tween the two fluids). Sometimes called Overall Coefficient of Heat Transfer. Common unit is ptu per (hour) (square foot) (Fahrenheit degree). Symbol 17. 6 Fromffl<L^?SSp?'o firSK *"wb are given in parentheees. Olouary of Phynet, by LeRoy Dougherty WeldtMcGinw-Hil], 1937].