Document 2R7OZy1Lj52o8RzOv032JjnNb

C E NTRAL^ Engineering PARTMENT CEA NO. 2132 PRODUCT PROGRESS REPORT #8 ar no.1800|date ^ 1430.1452 /^fl/20/69\ /------------- -------------- \--------- Elec t r icarT^G^cade Aroolors T.TLE / / Ar/Dclor ]>urification / _( V________ J.. DIVISION \ Organ ibv. Anni55Sh\ DISTRIBUTION ceo section manager ced project manager R. M. Kountz R. C. Herman division representative R. A. Haydel 0. R. Bailey J. M. Depp M. Dmytryszyn R. E. Emling F- W. Enoch J. R. Fair F. J. Holzapfel R. W. Kaltenrieder F. P. LaBelle R. E. Lenz Russell L. Miller C. L. Parish L. H. Todd (2) L. R. Burchfield R. R. Cook R. E. Howard R. W. Peterson J. L. Mathews W. C. Geil R. Q. Brown Organic Division . W. A. Kuhn D. A. Olson W. R. Richard V" Anniston Plant N. B. Papageorge H. L. Williams V. Haupt J. C. Landwehr H. E. Waldrep SCOPE: Purification (Porocel) columns and auxiliary equipment for improving the quality of electrical grade aroclors are being provided by this project. DSW 199809 C O N FI O E N T I A L I N F O R M A T 1-0 N /A THIS DOCUMENT IS THE PROPERTY OF MONSANTO COMPANY AND THE RECIPIENT IS RESPONSIBLE FOR ITS SAFEKEEPING AND DIS POSITION IT CONTAINS CONFIDENTIAL INFORMATION WHICH MUST NOT BE REPRODUCED. REVEALED TO UNAUTHORIZED PERSONS OR SENT OUTSIDE THE COMPANY WITHOUT PROPER AUTHORIZATION. !W- ei_ < 2 A O t-n 0 /Q STLCOPCB4057873 Product Electrical Grade Aroclors_________ i nrarinn Anniston T'tie Aroclor Purification______________________ Data Tabulated As Of _ 10/31/69 CEANn. 2132 AR No. 1800/1430/1452 Appreciation Current Estimate Date of Estimate Expended & Committed Soent This Month Scheduled Completion On Schedule? MS * MS 250 11/8/69 MS 245 MS 7 9/1/69 In Operation Process Design, % Complete Mechanical Design, % Complete Construction, % Complete % Expended & Committed Design Manpower Construction Manpower Last Month 100 100 99 85 1, 2; 100 100 100 96 o o *This project is being funded by a variance to the omnibus. TCB & TTCB Columns (North Structure) These columns have been iii operation since 9/19/69. Aroclor Columns (South Structure) These columns have been in operation since 10/30/69. (The start-up of these columns was suspended during the recent plant strike). The product quality resulting from treatment in the new columns is within acceptable limits. The existing power factor instrument has not operated properly since the new columns were, placed in service. The problem is thought to be due to contamination in the new instrument supply system. The Plant is taking samples at various points in the supply system to locate the origin of the contamination. Final closure of the project is planned for December 1969. RCH/bl 'L - Cl . v w^r vv R. C. Herman DSW 199810 STLCOPCB4057874