Document 2R7OZy1Lj52o8RzOv032JjnNb
C E NTRAL^
Engineering PARTMENT
CEA NO.
2132 PRODUCT
PROGRESS REPORT #8
ar no.1800|date
^
1430.1452 /^fl/20/69\
/------------- -------------- \---------
Elec t r icarT^G^cade Aroolors
T.TLE
/
/
Ar/Dclor ]>urification /
_( V________ J..
DIVISION
\
Organ ibv.
Anni55Sh\
DISTRIBUTION
ceo section manager ced project manager
R. M. Kountz R. C. Herman
division representative R. A. Haydel
0. R. Bailey
J. M. Depp M. Dmytryszyn
R. E. Emling F- W. Enoch J. R. Fair F. J. Holzapfel R. W. Kaltenrieder F. P. LaBelle R. E. Lenz Russell L. Miller
C. L. Parish
L. H. Todd
(2)
L. R. Burchfield R. R. Cook R. E. Howard R. W. Peterson J. L. Mathews W. C. Geil R. Q. Brown
Organic Division
. W. A. Kuhn D. A. Olson W. R. Richard
V"
Anniston Plant
N. B. Papageorge H. L. Williams V. Haupt J. C. Landwehr H. E. Waldrep
SCOPE:
Purification (Porocel) columns and auxiliary equipment for improving the quality of electrical grade aroclors are being provided by this project.
DSW 199809
C O N FI O E N T I A L
I N F O R M A T 1-0 N
/A
THIS DOCUMENT IS THE PROPERTY OF MONSANTO COMPANY AND THE RECIPIENT IS RESPONSIBLE FOR ITS SAFEKEEPING AND DIS POSITION IT CONTAINS CONFIDENTIAL INFORMATION WHICH MUST NOT BE REPRODUCED. REVEALED TO UNAUTHORIZED PERSONS
OR SENT OUTSIDE THE COMPANY WITHOUT PROPER AUTHORIZATION.
!W-
ei_ < 2 A O t-n
0 /Q
STLCOPCB4057873
Product Electrical Grade Aroclors_________
i nrarinn Anniston
T'tie Aroclor Purification______________________
Data Tabulated As Of _
10/31/69
CEANn.
2132
AR No. 1800/1430/1452
Appreciation Current Estimate Date of Estimate Expended & Committed Soent This Month Scheduled Completion On Schedule?
MS * MS 250
11/8/69 MS 245 MS 7
9/1/69 In Operation
Process Design, % Complete Mechanical Design, % Complete Construction, % Complete % Expended & Committed Design Manpower Construction Manpower
Last Month
100 100
99 85
1, 2;
100 100 100
96
o o
*This project is being funded by a variance to the omnibus.
TCB & TTCB Columns (North Structure)
These columns have been iii operation since 9/19/69.
Aroclor Columns (South Structure)
These columns have been in operation since 10/30/69. (The start-up of these columns was suspended during the recent plant strike). The product quality resulting from treatment in the new columns is within acceptable limits.
The existing power factor instrument has not operated properly since the new columns were, placed in service. The problem is thought to be due to contamination in the new instrument supply system. The Plant is taking samples at various points in the supply system to locate the origin of the contamination.
Final closure of the project is planned for December 1969.
RCH/bl
'L - Cl
. v w^r vv
R. C. Herman
DSW 199810
STLCOPCB4057874