FLUID HEAT
SYSTEMS
ENGINEERING HEAT TRANSFER DATA
A Design Guide For Engineering Low-Cost, Low-Pressure FIRE-RESISTANT HEAT TRANSFER SYSTEMS
0635221
TOWOLDMON0040338 WATER PCB-00024807
/
4
11
TABLE OP CONTENTS
Introduction.................................................................................................. Properties Important To Heat Transfer Design................................... Curves: Viscosity /Temperature; Density, Specific Gravity.............. Curves: Specific Heat; Thermal Conductivity...................................... Specific Heat of Therminol Fluids: Relationship To Density........... The Heater..................................................................................................... Therminol System Components..............................................................
Pumps, Piping, Valves, Rotary Joints, the Expansion Tank, etc. Testing, Cleaning, Filtering....................................................................... Controls for the Therminol System......................................................... Operation and Maintenance of the Therminol System....................... Typical Therminol Systems...................................................................... Therminol Engineering Data..................................................................... Resistance of Valves and Fittings To Flow of Fluids.......................... Pressure Drop: Heat Transfer Rate, Heat Exchangers........................ Viscosity Conversion Chart...................................................................... Engineering Conversion Factors.............................................................. Typical Applications for Therminol Systems....................................... Safety of Handling Therminol Fluids...................................................... Notes..............................................................................................................
Page
1 3 .4 .S .6 8 11
. 14 18 16 18 22 29 30 38 36 46 46 47
I
1
0635222
|
TOWOLDMON0040339 WATER_PCB-00024808
FR FLUID HEAT SYSTEMS...
Delivering High-Temperature Process Heat as a Liquid
As recently as 1941, process engineers were limited to two methods of delivering process heat: DIRECT FIRING or PRESSURIZED VAPOR. Each method had definite draw backs. Direct firing was often unsatisfactory because the heating waB uneven, the tempera tures difficult to control, and the processing of combustible materials extremely hazardous. Pressured-vapor, such as steam, required costly, high pressure piping, valves, and proc essing equipment--plus constant chemical "conditioning" of boiler water. Heat energy and temperature loss were common with presaured-vapor systems because of "blowdowns," condensation, and the inevitable pressure loss with long runs of piping.
Today, non-pressurized, high-temperature, fire-resistant heat transfer systems based on Monsanto's THERMINOL FR Heat Trans fer liquids overcome practically all the de
ficiencies and drawbacks of direct firing and pressurized-vapor heating. THERMINOL FR--a series of high-boiling, heat-stable organic liquids, delivers processing heat to single or multi-users as a liquid without pres surizing. THERMINOL fluids are safe and fire resistant. Heating is uniform; and tem perature control is accurate within a range of plus-or-minus 2F.
Heat transfer systems now in use for several years have proved THERMINOL fluid heat successful in a wide variety of process heating operations ... from food cooking to chemical processing, from distillations to drying ovens and in petroleum refining.
Design engineers and manufacturers have developed a variety of THERMINOL FR Fluid Systems ranging from small electrically heated units to giant gas or oil fired units-- all capable of delivering heat AS A LIQUID.
0635223
|
TOWOLDMON0040340 WATER_PCB-00024809
y
This manual explains and illustrates the fundamentals of THERMINOL fluid heat transfer systems design. It lists materials of construction and components for use with THERMINOL, and explains how each is ``designed in" to make the most efficient system for safe, economical and reliable opera tion. It shows how these systems can be adapted to a wide variety of heating and cooling processes. This engineering heat trans fer data has been compiled to aid the Process Engineer in designing a safe, minimum main tenance system for delivering heat to the points of use in practically any commercial or industrial process.
0
rhermJjl.oiikFR HEAT transfer liquids...
Monsanto THERMINOL FR heat transfer liquids are chlorinated biphenyls, manufac tured under exacting process control to pro duce fluids consistent in all properties impor tant to heat transfer. THERMINOL FR products are unique in that they are actually produced to rigid specifications for thermal stability, specific heat, thermal conductivity, vapor pressure, and viscosity.
There are three THERMINOL FR products, with a range of low temperature fluidity and boiling points that allows the user to select the best balance of fluid properties for a specific use:
THERMINOL PR I with lowest temperature fluidity -- excellent for processes requiring both heating and cooling
THERMINOL FR 2 with optimum balance of properties for use in most common industrial heating applications
THERMINOL FR 3 with highest boiling point for special proc essing equipment applications
J
063522*.
2 TOWOLDMON0040341 WATER_PCB-00024810
PROPB
IMPORTANT TO HEAT TRANSFER DESIGN ' . THIRMINOL FR-1
TmMritwftf. Knthalpy RvmMjiHwI s Thttms) Conduct F. rjw BTU/U. rortii-T. ITU/Ft!, Hr.,F./F(.
I:" ';
5J *. S7. s
MO* iMr<: *' W* '
*** ;-i **.,
. ' .
0.00098 0.06000 0.06021.
,*
` 0.09970
.* ' 0X5927
850^ 460*
^ 140* 17?
m *,-
, ms
* 748fcc> M.94?r irs5fc"
. uuMg Skf*!* 'awjl.v HR*ji
- 0.0687S 0.00819
0.08700 0,05097
80&W' S. - mk
w * S mif. *?
7W * w
v 48778 jitfC
r^vrS3B^fi IW m.*rv
f a *NJ
"
0.05690 0.05860 0.06467 0.05409
0.05329
*
Donalty Lb./Qal.
11.683 11.488 11.216 10.961 10.760 10.628 10.206 moos 9.833 ' 9.001 9.370 9.138 8.908 iins
-wf''-.-",. 1
' THIItMINOL FR-S
Vlacoaity Lb./Hr.-Ft.
745.36 56.144 15.972 8.2481
5.5270 3.4158 2.4753 1.8898 1.9028 1.2351 1.0428 0.90031 0.79188 0.70731
Vapor Pros. mm. Hg. Abaoluto
10 27 66 143 291886 %
18.8 ptla 31.9 pala
.
TampafAtur*- Knthalpy
f, k e.
BTU/U.
60 100/v 150.
200
260 300
360 400 460
500 550 600 050
700
10.0
37.6
68
98 '
121
149 , 177
204
232 260 288 316 343 371
4.89 17.91 31.09 48.11 59.43
74.14 89.29 10441 120.74 \StlW 158.86 . 170.99' 188.68 203.46
pwHIa Ht Tfiarmal Conduct
TU/LL-JT. Tll/Ftf, Hr..F./Ft
' 0.26? 0.286
0.05661 0.0B859
0.274
0.05801
0.2840
0.05788
0.2922
0.05748
0.3003
0.05703
0.8064*' 0.8180 0,8247
0.05655 0.05603 0.05548
04828.
- 0.05486
0441# \ *., 0.05424
. aamiA !jS
. 0.05387
o,smv' t - . 0.05286
tarn-*- ;v
0.06211
Donalty Lb./Gal.
12.225
12.000
11.750 11.525 11.293 11.082 10.830 10.598 10.367 10.135 9.903 9.672 9.440 9.208
Vlaeoalty Lb./Hr.-Ft
7090.8 151.01 27.83 11.971 6.949 4.631 3.201 2.399 1.831 1.529 1.2795 1.0971 0.9596 0.8536
Vapor Proa. mm. H9. Abaolulo
8
18 37 84 173 346 615 20.3 pala
THIRMINOL RR-3
Tamparfltura
F. c.
Knthalpy rmMrNwI Tharmat Conduct. Danalty
BTU/Lfe
BTU/Pt?f Hr.,*F./Ft Lb./Qal.
50 10.0 , 100 ' 37.8 150 ,, 66 200 93
250 . 121 300 149;''
350 177 400 ' '204'
480''-':" 282> > 500 BOO 850^ S88 500 316 t < 650 $4#V , 7Q0X 'l 871
4.28 - . ON*',' / 2 0448 \ *
f.0.2629
0.2714
,* ' 0.2799
' 0.2884
mi'' ^ 0.2969
113.96V
0.8084-
128.?%'
0.3130
144.73s-
0.8228
isr.ii
0.83M
177.92 ' 04888
192.24
0.8478
v''9.06700 "W 0.06680
0.06084 0.06620
0.06598 0.05558 0.05513 0.05468 0.06415 0.05360 0.05302 0.05241
0.08178 0.05107
13.002 12.760 , 12.534 . 12.292 12.061 : 11.829 11.597 11.366 11.134 10.902 10.671 10.439 10.207
9.976
Viacoaity
__Lb./Hr.-Ft.
1628.6 101.64 24.262
12.091 7.116 4.669 3.306 2.478 1.937 1.5699
1.3095 1.1168 0.97531
Vapor Proa. mm. Hfl. Abaoluta
3 9 24 55 114 223 413 735
0635225
I
TOWOLDMON0040342 WATEFLPCB-00024811
si TOWOLDMON0040343 WATER_PCB-00024812
0635227
I
TOWOLDMON0040344 WATER_PCB-00024813
SPECIFIC HEAT OF
ther
FR
Its Relationship to Density
Specific heal--the quantity of heat required to raise the temperature of a material one degree, compared to the heat required to raise a like mass of water one degree--compares the material with water, pound for pound.
When comparing specific heat values of THERMINOL FR liquids with correspond ing values of other heat transfer fluids, it is important to note that the density of THERMINOL is much higher than the den sity of Other fluids commonly used in heat transfer. In consequence, the heat capacity of THERMINOL fluids is greater than imme diately apparent from the specific heat values.
In transferring heat, a volume of fluid is circulated to give up or absorb heat and the heat capacity of that volume of fluid is the
When a comparison is made on a volume
basis (as illustrated below), THERMINOL liquids are comparable to other organic liq uids and superior to some:
SPECIFIC HEATS OF VARIOUS FLUIDS at ROOM TEMPERATURE
Pounds/ Gal.
Specific
Heat
Heat Capacity
(BTU/lb./ (BTU/gat./
F.) 6F.)
THERMINOL FR 2 Organic Fluid "A" Petroleum Oil
12.03 6.82 7.9
0.276 0,378 0,378 .
3.33 2.9B
D
0
THE FLUIDS
THERMINOL FK liquids are unique. They permit installation of a non-pressurized sys tem operating with a liquid which has no fire point, and will not support combustion, THERMINOL FR liquids are so fire-resist ant they have been listed with Underwriters' Laboratories!
Because of this extreme fire resistance and its recognition by insurance companies, impor tant savings can be made in designing a process heating system around THERMINOL FR fluids. The savings include not only the lower capital cost of non-pressurized equip ment, its simplified installation and lower maintenance; but also elimination of some of
the costly safety devices required in equip ment circulating a flammable fluid at or above its lire point. These economies show up both in the type of components needed and in the layout of the system.
Still another unique property of THEHM INOL fluids is their unusual chemical inert ness. They are among the most oxidationresistant compounds known. This inertness prevents the formation of oxidation sludges if the hot fluid comes in contact with air. This extends the useful service life of the heat transfer fluid; occasionally allows economies in design. However, THERMINOL FR fluids are not intended for use in open vessels but in properly vented, closed systems.
0635228
TOWOLDMON0040345 WATER_PCB-00024814
Chemically, THERMINOL FR fluids are resistant to strong acids, mild alkalies, and dilute solutions of strong alkalies.
THERMAL STABILITY
THERMINOL FR fluids are thermally stable. They are manufactured to meet strict thermal stability specifications. Each produc tion run is tested in Monsanto's laboratories with special equipment developed by Monsanto to assure that these fluids meet the high standards of thermal stability. Any material which does not meet these standards is rejected.
It is characteristic of almost all organic mate rials to undergo chemical change when ex posed to high temperatures for long periods of time. The type of chemical change depends upon the molecular structure of the fluid; the degree of change depends on the temperature, and the length of time of exposure.
THERMINOL FR fluids resist chemical change up to temperatures of 600F. and show no measurable change after years of exposure to such temperatures. Exposure to temperatures above 600F. --even localized overheating will only cause some formation of "high boilers'': molecules of THERMINOL FR will join together to form larger molecules quite similar to the original material, but higher in viscosity and in boiling point. These high boilers are soluble in the fluid up to reasonable concentrations: so overheating only increases the fluids' room temperature viscosity slightly. When a concentration of appioximately 5-10 percent "high boilers" has been formed, however, the viscosity begins to rise quite sharply.
With this change, small but measurable amounts of dry hydrogen chloride gas are evolved. This should be removed from the system by appropriate venting. When THERMINOL FR fluids operate at high bulk temperatures, or, where some local over heating may occur, the system should be designed to prevent moisture from condensing in the vapor spaces where this hydrogen chloride gas is being vented.
When the hydrogen chloride is dry, it has little or no effect on metals in the system. However, if the hydrogen chloride dissolves in moisture, an acid corrosive to certain metals is formed. A properly designed heater and distri bution system operated at or below 600F., will allow use of the same fluid for many years.
While THERMINOL FR fluids normally are operated to a maximum temperature of 600F. -- systems specially designed for operation at higher temperatures have proved successful. At higher temperatures--"high boiler" forma tion with attendant viscosity increase is, of course, accelerated and a shorter service life must be expected. However, side stream dis tillation can be employed to constantly re move higher boiling materials while the Bys tem is in operation. Periodic make-up is added to replace the quantity of the high boiler material removed.
An alternate procedure for higher tempera ture operation, which is sometimes more suitable for smaller installations, is periodic replacement of the THERMINOL charge, reclaiming the used fluid by straight take over distillation. (Monsanto should be con tacted for details regarding this procedure,) On systems containing only 50-100 gallons of THERMINOL, it is usually most economical to periodically discard the entire charge and replace it with new fluid.
THERMINOL SYSTEM DESIGN
When designing a THERMINOL FR system it is important to remember this fact: THE FLUID CAN BE NO BETTER THAN THE SYSTEM! THERMINOL FR liquids are ideally suited for high temperature preci sion heating and temperature control applica tions, but only if the heater and distribution system are properly designed, constructed and operated. While there is nothing profoundly different or complicated about a THERM INOL system, certain design parameters must be rigidly observed if the system is to operate trouble-free, efficiently, and with realization of the full benefits of heat de livered by a liquid.
0635229
|
TOWOLDMON0040346 WATER_PCB-00024815
1
THE HEATER The heater is the most critical component in a
THERMINOL system. Accordingly, the heater should be selected with great care!
Two basic heater designs for THERMINOL fluids are available: the liquid tube and fire tube types. In liquid tube heaters, the THERMINOL is pumped through the tubes at a definite flow rate as it is heated; in fire tube types, THERMINOL flows through the "shell" of the heater surrounding the fire tubes.
When operating temperatures of SOO^F. (or higher) are required, a liquid tube type heater is to be preferred ... unless a specific design is devised to force a steady flow over the heat donor surfaces.
Since THERMINOL fluids transfer heat in liquid form, they do not form vapor to ac celerate convection circulation. To avoid hot spots in a THERMINOL heater, the fluid should be pumped over the heating surfaces so that no area of stagnant fluid occurs.
Fluid velocities over the heat donor surfaces should be relatively high; generally 4 to 10 feet per second. This helps avoid both exces sive fluid film temperatures and also reduces the quantity of fluid in the high temperature film that is in direct contact with the heat donor surface.
The illustration shows the effect of fluid velocity on film temperature and indicates the importance of this design requirement,
EFFECT OF LIQUID VELOCITY ON FILM
TEMPERATURE DURING HEATING
High Liquid Velocity
Low Liquid Velocity
<5
Importance of Fluid Velocity and Film Tem perature through Heater
A bulk fluid temperature of 600F. and a maximum film temperature of 640F. assures long service life of THERMINOL FR fluids. Note the significance of "maximum" film temperature: heating is not uniform in fired
l
0635230
TOWOLDMON0040347 WATER_PCB-00024816
heaters, and maximum conditions--not aver age-must be used to determine the recom mended 640F. ceiling.
Example: The film coefficient for THERMINOL in a given heater is 250 BTU/hr. sq. ft., F., and the fluid temperature is 570F. The average radiant absorption rate is 9,000 BTU/eq. ft., hr. The maximum ra diant absorption rate is 17,000 BTU/sq. ft., hr.
The average film temperature is then
but the maxmium film temperature is
Past experience shows that when purchasing a heater, the buyer should insist that design and capacity provide optimum film tempera ture for the fluid. The method of Lobo and Evans^is useful in calculating film temperatures in radiant heaters. When electric heaters are used--heat flux is more even. However, it is important to re member that all of the heat from the electric element passes into the fluid. The watt-density on the surface of the heater tube and the fluid velocity past the tube should be in proper
balance to avoid excessive THERMINOL film temperatures. Watt-densities in the range of 8 to 10 watts per square inch with a minimum velocity of 4 feet per second are suggested. However, watt-densities in the 18 to 22 watt per square inch range have proved satisfactory in properly designed installations.
Heaters for THERMINOL should meet local code requirements. However, the fire resist ance of THERMINOL FR fluids will often permit important economies in the design and placement of fired heater equipment. With gas-fired heaters, the THERMINOL unit need not be placed outside of the building or isolated in a fireproof structure unless the use process requires such precaution. Steam or inert gas smothering devices can generally be eliminated and a vapor tight firebox to retain smothering gases is not necessary.
The fuel for THERMINOL heaters is purely optional. Gas- or oil-fired heaters, and elec tric resistance heating are all used with success. Coal-fired heaters are generally not recommended because of their slow response to change of load at the heat source.
The over-all thermal efficiency of a fired heater will generally be comparable to steam boilers of similar size. Efficiencies of 75 to 80 percent can be expected when convection sections are added. Efficiencies of 60 to 70 percent are achieved with only a radiant section.
CO Lobo, W. E., and J. E. Evans, Trans. AlChE, 35, 743 (1939)
Several types of heaters which have operated successfully in THERMINOL syst ems are illustrated on the following page.
..... _
TOWOLDMON0040348 WATER_PCB-00024817
0635232
TOWOLDMON0040349 WATER_PCB-00024818
,'V
' \\
****.. .1
*,
'
PUMPS FOR THE fheri
FLUID HEAT SYSTEM..
In selecting pumps for a THERM1N0L system, it is important that the pump ca pacity and pressure head be sufficient to circulate the fluid at the rate demanded by the particular installation. For large flow rates, the fluid circulating pump should gen erally be the centrifugal type and any one of a number of brands of standard high tem perature centrifugal pumps designed for hot liquid service is suitable. Dean Brothers, Worthington, Ingersoll-Iland and Chempump for example, arc all used satisfactorily. For most THERM1NOL systems, cast steel pumps are best. Pump manufacturers usually specify that above 450F. fluid temperatures, a water jacketed, deep stuffing box or me chanical seal and water-cooled bearings be used. Mechanical seals are used widely today.
It is suggested that with a stuffing box, eight rings of packing be provided. Durametallic No. D-110, Garlock No. 736 and equivalent packings are satisfactory for the pump, and an open, non-overloading impeller is desirable to handle the cool, relatively viscous liquid at start up.
When a new system is first put into operation, a slight leakage may be noticed at the pump packing. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation.
Canned pumps such as Chempump Series T require no seal and have proved very service able in THERMINOL systems. Small gear
pumps are also used successfully in THERMINOL FR service because the fluids have good high temperature lubricating properties. However, gear pumps characteristically de crease in pumping capacity after extended use. When gear pumps are used, care should be taken in selecting the capacity so there is a margin that will assure adequate flow through the heater. Regardless of the type of pump selected, the flow rate should be checked regularly against its performance when new.
To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a way that avoids stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a control to switch off the burner in case of pump failure.
If expansion loops are used in the pump suction piping, they should be horizontal or vertically downward. They should not be vertically upward, for in such a position they form a trap which can collect air and non condensibles, and seriously hamper the pump's performance.
PIPING...
The most important factors in the piping layout for a THERM1NOL FR system are: (A) Proper sizing for the required flow rate and (B) minimizing pressure drop. Because the system will undergo temperature changes,
0635233
-I
TOWOLDMON0040350 WATER_PCB-00024819
adequate expansion joints and loops to relieve expansion and contraction stress are essential.
Generally, Schedule 40 seamless steel pipe is used with THERMINOL FR systems. It is characteristic of most organic fluids (includ ing THERMINOL) to have a tendency to leak through joints and fittings at high tem peratures unless these fittings are very tight. Therefore, flanged joints should be used sparingly to minimize potential leak points.
Threaded connections are used with THERMINOL FR up to a one-inch maxi mum size. Care is required in cutting the threads to assure a proper fit; a clean, new die is recommended. Careful attention to threading procedure should provide a good threaded connection. It is not wise to rely upon the use of pipe dope to eliminate leak age. However, pipe dope should be used. Q-seal (Quigley Company, Inc.); Flastiseal (Johns Manville); and Crane's No. 425 are all used successfully in THERMINOL FR systems.
In larger size pipes, welded connections should be used wherever practical. Careful layout and use of curved sections of pipe can mini mize the welded or flanged connections re quired. When a flanged connection is made, 150 pound raised face flanges are recom mended. The flange should be backwelded to the pipe and proper gasketing used. Spiral wound (Spiratalic or Flexitallic) asbestos and stainless steel gaskets are good. Small lip spiral wound gaskets are preferred over the wide lip type, because they allow better compression with the 150 pound flange. Garlock short fiber, pre-cut and cured as bestos gaskets have also proved satisfactory.
It is recommended that high temperature bolts, such as Crane Triplex steel bolts, which do not stretch, be used.
All high points in the piping system should be provided with vent valve connections.
VALVES...
One hundred and fifty pound cast steel valves with deep stuffing boxes are satisfactory for THERMINOL systems. Cast steel ball valves
designed for high temperature (such as offered by Hills McCanna have also proved very effec
tive, particularly where quick open-and-close action is desired.
ROTARY JOINTS...
It is wise to take particular care in the in stallation and maintenance of rotary joints in order to assure long service life and mini mum leakage, Install such joints with proper flexible connections to assure alignment at all times. Rotary joints should not be operated in a new system until the system has been thoroughly cleaned of abrasive particles which could score the sealing faces and cause leak age. Rotary joints such as those manufac tured by the Johnson Corp. and Perfecting Service Co. are satisfactory with THERM INOL FR.
THE EXPANSION TANK...
Proper design of the expansion tank for the THERMINOL system is quite simple, but is also very important to proper system operation.
Characteristic of most organic liquids, THERMINOL expands in volume about 4 percent for every 100F. temperature rise. In heating THERMINOL from room tem perature (70F). to 600F., the fluid in the system expands about 20 percent. Therefore, the expansion tank should be large enough to accommodate about 20 percent of the total volume of the entire system, including the fluid content of the heater, piping and all heat users. The tank should be sized so it is about one quarter full when the system is cooled to 70F. and three quarters full when the system is at a maximum operating temperature. The expansion tank should be fitted with a sight glass at the "full" range and with a float operated, low-level switch to shut off the burner in case of accidental fluid loss in the system.
Place the expansion tank in the circuit on the pump's suction side--above the highest point in the system.
The expansion tank also serves as the major venting point of most THERMINOL sys-
0i Oi
0635234
|
TOWOLDMON0040351 WATER_PCB-00024820
terns. The temperature of the fluid in the expansion tank is much lower than the bulk fluid temperature in the system. Connect the expansion tank to the system with a small diameter line to avoid thermal recirculation. However, make this line large enough to readily pass the flow caused by expansion and contraction in the system and to permit recirculation of fluid for moisture removal as explained below.
Because THERMINOL PR fluids are fire resistant, the vent need not be isolated from potential sources of ignition. However, the vent should be out of doors, particularly away from working areas, to eliminate pro longed or repeated contact with the vapors.
Care should be taken to prevent the entry of atmospheric moisture into the system as the expansion tank `breaths' air. The vent can be equipped with on air dryer, such as a calcium chloride pot or other desiccant.
An alternate procedure would be to blanket the expansion tank with nitrogen. However, if this is done, the THERMINOL system should be dried thoroughly before the system is sealed with nitrogen.
In systems using THERMINOL above 600F. (or in systems where accidental high film temperatures may occur in the heater) some provision must be made for venting any hydrogen chloride gas formed in the system and to assure that the system remains dry. Gas or water vapor will not escape readily through the "cold seal" connecting the ex pansion tank to the THERMINOL system. It is advisable to provide a pipe to feed a small side stream of hot THERMINOL through the expansion tank as illustrated at right to allow hydrogen chloride and water vapor to flash from the fluid. A small stream of hot THERMINOL from near the pump discharge should be piped directly into the vented expansion tank, so it enters the tank above the highest liquid level. A globe valve should be installed in the line to permit throttling the flow to the desired rate.
Experience shows this simple procedure to be extremely effective and completely satisfac
tory for removing hydrogen chloride and moisture from the THERMINOL system. Analysis of samples drawn from systems operating with such a device show that the THERMINOL fluid maintains minimum acidity and holds moisture at the low levels equivalent to newly manufactured fluid, even after prolonged periods of operation.
Provision should be made to prevent moisture from condensing in the vapor space above the liquid level in the expansion tank and in the vent. It iB advisable to trace and insulate the expansion tank and the vent so that any
moisture accidentally entering the system will remain as a vapor and will not condense. This will prevent corrosion of steel and elimi nate the need for higher cost alloys. The use of non-metallic vent pipe is also recom mended. Polyester piping (available from Fibercast), resin lined steel piping or other non-metallics resistant to THERMINOL vapors and to hydrogen chloride are com mercially available and have been used with great success.
MANUAL GLOBE
VALVE
,
IN ^"-1" LINE
DESICCANT POT ON VENT
NOTES... The expansion lank and vent should be traced and insulated. If steam is not available at the site, hot THERMINOL fluid can be passed through steel tracing tube.
0635235
TOWOLDMON0040352 WATER_PCB-00024821
TESTING FOR LEsAKAGE ...
When a new system has been installed, it is important to test for leaks. Probably the most widely used technique is to check for leaks with ammonia gas.. In this method, the 6ystem must be relatively dry and sealed. All vent valves should be closed and a tem porary pipe cap or slip blank installed at the expansion tank vent and at other points where there is no valve.
Ammonia gas is fed into the sealed system followed by air under pressures up to ten pounds per square inch. Any leakage areas can be readily detected by the escape of ammonia, Tiny amounts of ammonia vapors can be made visible as white smoke by directing a small stream of hydrogen chloride gas over each joint or fitting, and around each welded connection. Any leakage points can be marked, tightened, and then the system purged free of ammonia with plenty of air.
A satisfactory alternate procedure is Halogen Testing: in this procedure, introduce one pound of Freon F-12 or Freon F-22 for each fifty cubic feet of volume of the system. Carefully introduce air not exceeding 10 psig of pressure. At this air pressure, the con centration of Freon will be sufficient to give a sensitive test.
Attach a halide torch to an acetylene tank and light it. Using the M inch flame as a probe, explore for leaks by passing the end of the flame along seams and joints. If a leak is present, the escaping Freon will be drawn
% minto the acetylene flame turning it green. A
large leak will produce a violet color.
Leak testing with water is not recommended. Though effective, it creates a problem of introducing a large amount of water into the THERM1NOL system which will be hard to remove.
CLEANING THE SYSTEM...
After testing for leaks and making any re quired adjustments, the system must be thoroughly cleaned.
A new system will contain dirt, weld and mill scale and other foreign particles. Unless re moved, these particles will be carried in sus pension by the circulating THERMINOL. They may "lodge" in valves, controls, mechancial seals, rotary joints and other mechan ical equipment, causing faulty operation or component failure.
When purchasing the heating equipment, the
supplier should be requested to clean the
equipment as thoroughly as possible using
brushes, wiping rags and suitable solvents, such as tri- or perchlorethylene.
e
When completed, fill the system with the operating charge of THERMINOL. Bring the system up slowly to approximately 200F. At this temperature, the viscosity of THERMINOL will be very low. The turbu lence from this low viscosity, plus the excel lent solvent action of THERMINOL fluid, will further clean the system. Circulate the warm THERMINOL through the system without operating rotary joints (if they are installed in the system).
FILTERING...
Install a strainer, made of ordinary fine mesh screen backed up with M" screen, in the pump suction of the new system. As foreign material collects, this screen should be peri odically removed and cleaned. When, after several days during which the strainer col lects no material, remove it permanently from the line. The system should be heated and cooled for a minimum of two cycles with the suction screen in place, since the resultant expansion and contraction will loosen mill
0'
0635236
|
TOWOLDMON0040353 WATER_PCB-00024822
mie q'he screen may be placed in the main stream line, gasketed between two flanges.
R is advisable, when operating where solids nnd contaminants might enter the system, to permanently install a high temperature filter on a by-pa^ line that can be isolated with valves for periodic cleaning.
CONTROLS...
Controls for heating systems using THERMINOL should be installed both on the heater itself and on the heat-using units. A wide variety of thermal-operating controls are available, and any reliable standard equip ment is satisfactory.
Install heater controls to regulate the firing mechanism in direct proportion to the re quired output. These controls should increase or decrease the heat in-put to maintain the THEKMINOL at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off" or "high-low" con trollers; larger units will operate more uni formly if equipped with modulating tem perature controls.
Install user controls to regulate the flow of the heat transfer fluid in proportion to the heat-consumption of the heat-using equip ment. In a multiple-user system, separate controls should be installed on each consum ing unit, to assure the proper heat-delivery.
Safety Controls. In addition to activating controls, the heater must also be fitted with the proper safety controls to meet the local code requirements. Safety controls should include:
a. High temperature cutoff at the heater outlet... to shut off the burner in the event of an excessive temperature rise.
b. High tube wall temperature cutoff. A thermocouple sensing element should be installed in contact with the radiant heated surface at the highest temperature point in the heater and protected as much as possible from direct or reflected radiation. Such a controller is usually of the on-off type with the switch wired into the flame
safety circuit so that the burner is shut down when the switch opens. Aside from protecting the tube bundle, this safety con trol protects the THEKMINOL fluid from overheating. c. Low flow cutoff. This control will shut down the burner should flow rate drop below design rates, or if a loss of flow occurs due to pump mal-function or failure. Equip burners with regular automatic ignition controls and flame failure controls. In wide range firing operations, an over-fire draft con trol will increase the economy of the opera tion. Electric power failure and instrument air failure safety controls are also desirable. In general, the practice of "fail-safe" instru mentation and control is essential: use good quality indicating and recording gauges, with scales calibrated for the particular limits of operation for best reading accuracy.
L:
0635237
|
TOWOLDMON0040354 WATER_PCB-00024823
OPERATION AND MAINTENANCE OF THE THERMINOL SYSTEM...
The following recommendations are intended only as guides. These suggestions are sup plemental to the equipment manufacturer's recommendations as they relate to the par ticular heater or the user equipment in the installation. The following comments on start-up, shut-down, power failure precau tions, and periodic fluid check-ups apply generally to all sizes and types of equipment.
NEW SYSTEM START-UP...
For a new installation, or an existing system that has been drained and is idle:
1. Check the safety and control devices. Check the safety and control devices for proper installation, proper range settings for the operation, and actual operation (by manually activating the instrument).
For protection of the over-all system and for predictable long fluid life, it is vital that all instruments and controls perform properly.
2. Check for leaks (see section on leak testing, page 14.)
3. Pull Vacuum on System.
a. The vacuum should be pulled from a point of high elevation in the system; usually at a point just below the expansion tank. Prior to drawing a vacuum, close all valves to the expansion tank; close all valves and vent connections to the atmos phere; close all valves to non-pressure equipment in the system (such vessels may collapse under vacuum) and open all valves in the interconnecting piping of the system.
b. Turn on vacuum equipment and evacu ate theentire system (including the "users") to 26-27 inches of mercury vacuum (if possible), or until the absolute pressure of the system has reached the limit of the available vacuum equipment.
c. Shut off vacuum equipment.
4. Charge the System with THERMINOL.
a. Fill the expansion tank with THERM INOL, and introduce the fluid slowly into
the system through the expansion tank valve until the tank is almost empty. Close the valve and again fill the tank. Open the valve allowing the fluid to enter the system and repeat until it no longer flows by gravity.
b. Open all valves then start the main circulating pump in accordance with the manufacturer's recommendations. Observe the liquid level in the expansion tank re peating "a" above until the Bystem has been filled. The thermal expansion of THERMINOL must be allowed for in determining the cold charge level. (A 20% expansion can be expected when heated to 600F.--as a guide, the expansion tank should be 70-76% full at the hot operating condition.)
c. Circulate the THERMINOL fluid through the system for about 3 to 4 hours to eliminate air pockets and to assure com plete fill of the system.
BEFORE FIRING HEATER, BE SURE THAT THERMINOL IS CIRCULATING FREELY.
5. Fire Heater.
a. On new installation start-up, or after prolonged shut-down, bring the system up to temperature slowly--about 100F. per hour. This will prevent thermal shock to heater tubes, tube/header joints, refrac tory materials, etc., and allow operators to check the functioning of instruments and controls and become familiar with the equipment's operation. The slow heat-up will also allow any moisture trapped in the system to escape as a vapor.
b. Bring system to operating temperature and put "users" on the line.
DAILY START-UP... when equipment has been shut down overnight or for week ends, follow this procedure:
1. Start the circulating pump and check the expansion tank level to see that the
WMmmmmmwwsmmm'mmm-m-Mmrnmmmm
0
>0
<1
<1
0635238
TOWOLDMON0040355 WATER_PCB-00024824
^ ' -9
THERMINOL is at the proper cold-start level (tf-full).
2. Start burner at the "low" flame setting and continue full circulation until the THERMINOL bulk temperature reaches 180*F.
3. Turn heater up to full heat.
SHUT-DOWN . . . should be performed as follows to avoid overheating:
1. Shut off burner completely with circulating pump still operating. Continue to run the pump at full capacity for at least 30 minutes to dissipate residual heat in the combustion chamber of the burner.
2. Shut off circulating pump after M hour, and switch off all heater electrical controls.
COLD WEATHER PRECAUTIONS...
When the THERMINOL system is exposed to low ambient temperatures, it is often most practical to leave the system "idling." Turn the burner to "low" position, and allow the fluid to circulate continuously at about 200F. The unit will then be "at ready" for imme diate high-temperature operation, and the viscosity of the fluid will remain low and workable.
IN CASE OF POWER FAILURE...
The burner circuit should be shut down by the heater controls. When the power comes on, run the circulating pump for a few moments to eliminate any vapor pockets that might have been formed by the fluid remain ing static in the hot combustion chamber. If there is no knocking in the piping system, full-fire may be resumed immediately if the fluid temperature is above 180F.
PERIODIC CHECK-UPS...
The regular maintenance inspection schedule should include the manufacturer's recom mendations, as well as inspection of the THERMINOL. Following is a listing of in spection check-points:
1. Lubrication of moving parts.
2. Operating fidelity and accuracy of readings
of safety controls and temperature limit controls.
3. Inspection of heater tubes, burner, refrac tory linings.
4. Periodic inspection of heater surfaces.
5. Inspection of water cooling at the circu lating pump.
6. Repacking of stuffing boxes (according to manufacturer's specifications).
7. Semi-annual or annual sampling and anal ysis of THERMINOL.
Under normal operating conditions, it should not be necessary to check on the condition of the fluid more than once or twice annually. The analysis for fluid condition is a simple test of fluid viscosity. The exact viscosity limits will be affected by the specific mode of operation and can vary somewhat from sys tem to system. Monsanto should be contacted to determine specific values for the intended operation. Most users do their own testing; some have the viscosity determination made by an outside laboratory. A simple test kit for in-plant testing of THERMINOL is available at a low cost.
Customers can have their fluid tested by Monsanto free of charge. For sampling con tainer and application data form, write to:
MONSANTO COMPANY FUNCTIONAL FLUIDS MARKETING ORGANIC CHEMICALS DIVISION ST. LOUIS, MISSOURI 63166
Analysis results will be returned to the cus tomer with complete recommendations for improving or continuing the performance of THERMINOL heat transfer liquid.
$
0635239
|
TOWOLDMON0040356
WATER_PCB-00024825
TYPICAL t h e r mirinJk FR
SYSTEMS
THE HEATING PLANT
Figure 1 above Illustrates a typical basic heating "plant*' for a THERMINOL FR system. Note the use of Instruments to control THERMINOL temperature leaving the heater and by-pass flow control to assure adequate flow through the heater regardless of "user" demands.
;j
>0 (
0633240
|
TOWOLDMON0040357 WATER_PCB-00024826
HEATING A SINGLE USER:
FIG. 2
FRC^FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER
Note that the user temperature can be controlled by either (a) rate of flow of THERMINOL to the user, or (b) temperature of THERMINOL, varied by fuel input fo the heater.
HEATING MULTIPLE USERS:
PIG. 3
PUMP
FRC=FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER
Note that each user can be controlled at a different temperature by control of the flow of THERMINOL and therefore the rate of flow of heat offered.
0635241
TOWOLDMON0040358 WATER_PCB-00024827
HRATINO OR COOUNO SEVERAL USERS SIMULTANEOUSLY
I <5)
ww- ;<? 0635242
TOWOLDMON0040359 WATER_PCB-00024828
,* ^^%!''rBMMIATURH CONTROL. BY BLBNOINO
FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER Single heater system provides varying THERMINOL temperatures to users ... finds application for processing heat-sensitive materials.
TOWOLDMON0040360 WATER_PCB-00024829
f l
thermljrLaik
FR ENGINEERING DATA
The design and installation of THERMINOL indirect heating systems requires a heat balance between the user(s) and the heater. The amount of heat which will be absorbed by the user in a given time depends upon the over-all heat transfer coefficient, the heat transfer area of the user, and the mean temperature difference between THERMINOL and the process or area being heated.
In processing most organic chemicals, oils, food cooking --the rate of heat transfer is usually dictated by the process and not by the heating medium. However, in designing a system --it is important to know the heat transfer coefficient of THERMINOL. This is affected by a number of variables, probably the most important of which is flow rate.
The following curves provide engineering data on THERMINOL heat transfer coefficients as a function of flow rate .. . and pressure drop as a function of flow rate ... in various common sizes of pipes and tubes.
NOTE: The following charts depicting heat transfer coefficients
and pressure drops for various sizes of pipes and tubes are
available in full page reproduction for greater accuracy in inter
pretation. Write to =
Monsanto Company
Organic Chemicals Div.
800 N. Lindbergh Blvd.
St. Louis, Mo. $3166
0635244
TOWOLDMON0040361 WATER_PCB-00024830
THERMINOL FR-1
HBAT TRANSFER COEFFICIENTS INSIDE TUBES
06352<t5
TOWOLDMON0040362 WATER_PCB-00024831
THERMINOL FR-2
HEAT TRANSFER COEFFICIENTS INSIDE SCHEDULE 40 PIPE
Ci
I
l
HEAT TRANSFER COEFFICIENT BTU/HR^ FT.* F.-4NTERNAL
10 20 30 40 50 70 100 200 300 500 1000 2000 4000 0000 FLOW-G.P.M.
HEAT TRANSFER COEFFICIENTS INSIDE TUBBS
i i,
HEAT TRANSFER COEFFICIENT BTU/HR* FT.*, CF--INTERNAL
f
I
0635246
24 _
TOWOLDMON0040363 WATER_PCB-00024832
_ THERMINOL FR-3
HBAT TRANSFER COEFFICIENTS INSIDE SCHEDULE 40 PIPE
HEAT TRANSFER COEFFICIENTS INSIDE TUBES
77L
5 7 10
18
FLOW--G.P.M.
40 50 70 00 100
0635247
TOWOLDMON0040364 WATER_PCB-00024833
PRESSURE DROP--P-S-l. PER 100 FEET
THERMINOL FR-1
PRESSURE DROP IN TUBBS
j O ,(1.
r. t 1
$ 0635248
TOWOLDMON0040365 WATER_PCB-00024834
PRESSURE DROP--P.SJ. PER 100 FEET
THERMINOL FR-2
M I.,,,-.......... 1------ i
-----l..............,,,J .1 ,1--------------- 1--------------- 1 ........ ---I-. J J
10 go 30 40 50 70 100 200 $00 500 1000 2000 4000 5000 8000
FLOW--G.P,M.
PRESSURE DROP IN TUBES
06352^9
TOWOLDMON0040366 WATER_PCB-00024835
RE DROP--P.S.I. PER KJOFET
THERMINOL FR-3
0J
10
20 30 40 00 TO 100
200 300 000 1000 200C . 4000 0000 8000
.. :
FLOW-G.P.M. ' .
'
... '
PRESSURE DROP IN TUBES
2R -- |
TOWOLDMON0040367 WATER_PCB-00024836
1
m: m:\w \ . VA.LVBi'SiMS.1 PITTINOB TO PLOW OP FLUIDS
/ , A simple way to account lor the resistance ' offered to flow by valves and fittings Is to add to tbs length of pipe in the line a length which will give a pressure drop
: equal, to, that which occurs In the valves * , and fittings In the line, , .
Example: The dotted line shows that'
8000 fde resistance of a 6-Inch Standard Elbow A,
; ^equivalent to appronlmately to feel of
2000 6-Inch Standard Steel Pipe. .
1
.food MO
48-4I.-SO 42--4
'fr'ii iJ
300 . 200
iOl.l CL #0 .
t-|
-S& 1-20 ISudden Enlargement1-.^ w ' d/D--Jf
d/D-X
Elfb-
Ordinary Entrance
Standard Elbpw or.,
M
j run pf Tee reduced X
F>
K V-s-LA ISudden Contraction d/D-KX
I \'--d/D-X'A
_ '-----d/D--XX
&
45 Elbow
fc
< 4 3X < 3i
i^ix-
X----t
fc
s <
5
Q <z/>
0635251
|
TOWOLDMON0040368 WATER_PCB-00024837
PRESSURE DROP AND HEAT TRANSFER RATE FOR HEAT EXCHANGERS
. Part I
PROCEDURE TO OBTAIN PRESSURE DROP SHELL SIDE OF TUBULAR EXCHANGERS WITH THERMINOL FR-2
1. Enter Chart No. 1 with GPM @ average flow ing temperature--read average shell side velocity.
2. Multiply average shell side velocity with baffle correction (Be--Chart No. 3) to obtain cor rected velocity.
3. Enter Chart No. 3 with corrected velocityread uncorrecfed pressure drop.
4. Correct pressure drop-3 above--for temper ature, tube diameter and tube length.
Example:
THERMINOL FR-2
400F,
20" Shell
*/t" Tubes on 15/16"
Baffles
12" Pitch
Tubes
16' Long
400 GPM
1. Chart No. 1 400 GPM--20" shell--2.7 ft/sec. average velocity.
2. Chart No. 3 12" Baffle Pitch--0.6 correction 2.7 ft/sec. x 0.6=1.62 ft/sec. corrected ve locity
3.1.62 ft/sec. In 20" Shell **4.1 PSI uncorrected pressure drop.
4. Correct for temperature, tube size and length. Pressure Drop = 4.1 x 1.2 x 1.0 x 1.33 = 6.54 Ans.
Part II
PROCEDURE TO OBTAIN HEAT TRANSFER RATE SHELL SIDE OF TUBULAR EXCHANGERS WITH THERMINOL FR-2
1. Enter Chart No. 1 with GPM at average flow ing temperature-read average shell side velocity.
2. Multiply average shell side velocity with baffle correction (Bel, Chart No. 2) to obtain cor rected velocity.
3. Enter Chart No. 2 with corrected velocityread uncorrected h.
4. Correct h--(3 above)--for temperature and tube diameter.
Example:
THERMINOL FR-2
20" Shell 1" on IX"
Baffles
ID" Pitch
300
350 GPM
1. Chart No. 1 350 GPM--20" Shell =2.35 ft/sec. average velocity.
2. Chart No. 2 10" Baffle Pitch--0.875 correction 2.35 ft./sec. x 0.875-2.06 ft./sec. corrected velocity
3. 2.06 ft./sec. Chart No. 2 = 225 uncorrected h.
4. Correct h for temperature and tube diameter. 225 x 0.61 x 0.88" = 121 Ans.
Part III
NOTES:
a. Tubes to be on triangular pitch %" on '51s"; %" on 'Ms"; 1" on 1#".
b. All baffles cut 1 row of tubes past horizontal centerline.
c. Charts have base condition--on Baffles at 8" pitch. THERMINOL FR-2 at 550F.
Data on shell side pressure drop and coefficients Courtesy of Struthers Welts Corporation.
1
*1
0
| I |
I
t
0635252
80
TOWOLDMON0040369 WATER_PCB-00024838
TOWOLDMON0040370 WATER_PCB-00024839
CHART No. I AVERAGE SHELL SIDE VELOCITY
0
G.PJA @ AVERAGE FLOWING TEMPERATURE
0635254
|
TOWOLDMON0040371 WATER_PCB-00024840
BAFFLE PITCH--INCHES CORRECTED SHELL SIDE VELOCITY--FT.fSEC.
CHART No. 2
0635255
TOWOLDMON0040372 WATEFLPCB-00024841
UNCORRECTED PRESSURE DROP-PSI
CHART No. 3 PRE88UR6 DROP SHELL. SIDE
1.0 8.0 2.5 3.0 4.0 5 5 7 3 0 10 CORRECTED SHELL SIDE VELOCITY-FT./SEC,
0635256
TOWOLDMON0040373 WATER PCB-00024842
KINEMATIC VISCOSITY, IN CENTISTOKES
. VISCOSITY CONVERSION CHART (Converting Kinematic and Saybolt Viscosity to Absolute Viscosity) 2,000 -10,000
1,800 HT
* 1,000 J- 750 W
11,000 - 000 -wo -700 1-600 - 500
400
- 300
100 , JO I- 80
70 M
C5O
0. p 2 W
<0 20 >
0
-10
-30 " -> -40 fc
> w2 60 0 70
0635257
TOWOLDMON0040374 WATER_PCB-00024843
ENGINEERING CONVERSION FACTORS
MULTIPLY
ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES British thermal units British thermal units British thermal units British thermal units British thermal units British thermal units British thermal units Btu/cu, ft. Btu/hr. Btu/hr. sq. ft. Btu/(hr. sq. It. F.) Btu/(hr. sq. ft. 0 F.) Btu/(hr. sq. ft. F.) Btu/(hr. sq. ft. 0 F.) Btu/(hr, sq. It. F.) (Btu/hr. sq. ft.)/( F./in.) (Btu/hr. sq. ft.)/( F./in.) (Btu/hr. sq. t.)/( F./ft.) (Btu/hr. sq. ft.)/( F./ft.) (Btu/hr. sq. .)/(" F./lt.) Btu/miri. Btu/min. Btu/miri. Btu/lb. Btu/lb. mol. Btu/lb. F.
BY
14.70 2116.8 760 29.92 33.90 1.033 x I04 778.2 107.6 1055 0.2520 3.930 IO-4 2.930 I0-1 0.5556 8.90 3.927 10-' 2.712 4.882 1.0 1.356 x I0-4 5.68 x I0-4 2.035 * 1012.4 3.445 x 104.13 x I0-3 0.0173 14.88 12.97 0.02358 0.01758 0.556 0.556 1.0
TO OBTAIN
Ib./sq. In. Ib./sq. ft. mm. Hg. in. Hg. ft. of water kg./sq. meter ft. ib. kg.-meters joules kg.-cal. hp. hr. kw. hr. P.C.U.* kg.-cal./cu. meter hp. kg.-cal./hr. sq. meter kg.-cal./(hr. sq. meter 0.) P.c.u.*/(hr. sq. ft. C.) gram-cal./sec. cm.1 0 C. watt$/cm.2 0 C. watts/sq. in. 0 F. (kg.-cal./hr. sq, meter)/( C./cm.) (gram-cal./sec. cm.'J)/{ C./cm.) (gram-cal./sec. cm.*)/( C./cm.) (watts/cm.*)/(0 C./cm.) (gram-cal./hr. cm.s)/( C./cm.) ft. Ib./sec. hp. kw. gram-cal./gram gram-cal./gram mol. gram-cal./gram 0 C.
wmmmmammmammumv i.| i .si i p
Pound-Centigrad Unit
i n mil iiw 0635258
TOWOLDMON0040375 WATER_PCB-00024844
MULTIPLY
Btu/sec. Btu/sec. Btu/sec.
Btu/sec. Btu/sq. ft. Btu/*q. ft. CALORIES CENTIMETERS CENTIMETERS cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm./0 C. cm./sec. cm./sec. cm./sec. cm./sec. cm./sec. CENTIPOISES CENTIPOISES CENTIPOISES CENTIPOISES cubic centimeters cubic centimeters cubic centimeters cm.8/sec. cm.s/sec. cm.8/sec. cm.*/sec. cm.'/gram cm.8/gram mol.
CUBIC FEET CUBIC FEET
ENGINEERING CONVERSION FACTORS
BY
778.2 1.4147
1.0549 107.6
0.2712 2.712 See gram-cel. 0.3937 0.0328
0.01316 0.1934 27.85 136.0 5.353 0.4461 0.2187 1.969 0.03261 0.036 0.60 0.02237 0.01 2.42 6.72 x 10 3.60 0.06102 3.531 x 10 - 2.642 x 10 * 2.119 x I0-8 0.0864 O.OI58S 3.6 0.01602 0.01602
0.02832 7.481
TO OBTAIN
ft, Ib./sec.
bp. kw, fcg.-meter/sec.
gram-cab/cro* kg..cal./iq. mC'W
in. ft. atm. fc./ft *" lb. /sq. fi kg./t- me'e' in. of water ft. of water in./0 Fft./m'm. ft./see. km. Ar* meters/min. mph poises
Ib./ft. FrIb./ft. see, kg./meter hr. cu. in* cu. . gal. cu. ft./mln. cu. meter/dy gai./n,inliter/hr.
cu. /> . cu. ft./lb. ** cu. meters gat.
0635259
TOWOLDMON0040376 WATER_PCB-00024845
ENGINEERING CONVERSION FACTORS
m
MULTIPLY BY TO OBTAIN
CUBIC: FEET
28.32
liters
i
CUBIC: FEET cu. ft. gat (60 F. at 1 atm)
62.43 2.636 x I0*
lb. of water lb. mol.
eu. ft./lb.
62.43
cm.*/gram
i
cu. ft./min.
472.0
cm.8/sec.
cu. ft./mln.
0.1247
gal./sec.
cu. ft./sec.
448.8
gal./mfn.
cu. ft./sec. $q. It.
0.0305
literx/iee. cm.'
CUBIC INCHES
16.34
cm.*
CUBIC INCHES
5.787 * 10-
cu. ft.
CUBIC INCHES
0.01634
liters
CUBIC INCHES
4.324 x I0-*
gal.
CUBIC METERS
35.31
cu. ft.
CUBIC METERS
264.2
gal.
cu. meters/day
11.57
cm.*/sec.
degree:/sec.
2.778 x IO->
rev./sec.
degrees/sec. ERGS FEET FEET It. of water It. of water
0.1667 1.0 x I0~T 30.48 0.3048 0.0295 2.242
rpm joules cm.
meters atm. cm. Hg.
It. of water
0.8826
in. Hg.
ft. of water ft. of water
304.8 62.43
kg./sq, meter Ib./sq. ft.
ft. of water
0.4335
Ib./sq. in.
ft./mln. ft./min.
0.508 0.01667
cm./sec. ft./sec.
ft./mln.
0.01829
km./hr.
ft./mln.
0.01136
mph
ft./sec.
1.097
km./hr.
ft./sec. ft./sec.
18.24 0.6818
meters/min. mph
FOOT POUNDS
1.285 x I0's
Btu
FOOT POUNDS
3.234 x 10-
kg.-cal.
FOOT POUNDS FOOT POUNDS
3.766 x 10-' 5.05 x 10-'
kw. hr. hp. hr.
*Pound-C*i\tigrd Unit 38
0635260
TOWOLDMON0040377 WATER_PCB-00024846
ENGINEERING CONVERSION FACTORS
MULTIPLY
BY
ft. Ib./min. ft. Ib./mtn. ft. Ib./sec. ft. Ib./soc.
ft. Ib./sec. ft. Ib./sec. GALLONS (imperial)
gal. (U.S.) gal. (U.S.j
gal. (U.S.) gal. (U.S.) gal./hr. gal./min. gal./min. gal./min. gal./min. of water GRAMS GRAMS gram mole gas granvcal. gram-cal./grarn gram-cal./grarn mol. gram-cal./gram C. gram-cal./cm.* (gram-cal./cm.*)/cm. granvcal./(sec. cm.8 C.) (gram-cat./sec. cm.2)/( C./cm.) gram-cm. gram-cm. gram-cm. gram-cm. grams/cm. grams/cm.1 grams/cm.# grams/cm.* grams/cm.* grams/cm.s grams/cm.8
3.03 x I0"B 2.26 x I0-6 0.0771 1.818 x 10-' 0.01943 1.356 * I0-8
1.201
231 0.1337 3785 3.785 3.71 x I0'5 2.228 x I0-* 0.227 0.06309 500.6 980.7 2.205 x I0-3 2.24 x 10' 3.968 x I0-" 1.8 1.8
1.0
3.687 1.452 7.373 x 10* 2.903 x 10s 9.294 x I0"8 980.6 7.233 x 10- 2.342 x I0-8 5.60 x 10"8
1.0 62.43 0.07355 10 0.394 0.03281
TO OBTAIN
hp. kw. Btu/min. bp. kg.-cal./min. kw.
gal. (U.S.) cu. in. cu. ft. cm.8 liters cu. ft./sec. cu. ft./sec. cu. meters/br. liters/sec, Ib./Kr. of water dynes lb. cm.8 gas (0 C. and 760 mm. Btu Btu/lb. Btu/lb. mol. Btu/lb. 0 F. Btu/sq. ft. (Btu/sq. ft.)/in. Btu/|hr. iq. ft. 0 F.) (Btu/hr. .q. .)/(" F./in.) Btu ergs . ib. kg.-cai. Ib./in. specific gravity et 4 C. (b./cu. ft. cm. Hg. kg./sq. meter in. of water ft. of water
0635261
TOWOLDMON0040378 WATER_PCB-00024847
ENGINEERING CONVERSION FACTORS
MULTIPLY
grarm/cm.s grams/cm.* grams/cm.* HORSEPOWER I HORSEPOWER HORSEPOWER HORSEPOWER HORSEPOWER hp. (boiler) hp. (boiler) hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. INCHES in. Hg. in. Hg. in. Hg. in. Hg. in. Hg. in. of water in. of water in. of water In. of water in. of water in. of water in./ F. KILOGRAMS KILOGRAMS KILOGRAMS KILOGRAMS kg.-meters kg.-meters kg.-meters kg.-meters
Pcund-Centlgrad* Unit
40
BY
9.678 * 100.01422 2.048 42.41 3.3 x 10* 550 10.7 0.7457 3.347? x 10* 9.804 2.545 x 10s 1.98 x 10' 2.684 x 10* Ml.2 2.737 x 10s 0.7457 1.414 x 10* 2.54 0.03342 1.133 0.4912 70.73 345.3 2.458 x 100.07355 0.1869 25.40 0.03613 5.202 4.572 9.807 x 10* 70.93 2.205 1.102 x 109.302 x 10-' 7.233 2.344 x 102.724 x 10'*
TO OBTAIN
atm. Ib./sq. in. Ib./tq. ft. Btu/min. ft. Ib./min. ft. Ib./sec. kg.-cal./min. kw. Btu/hr. kw. Btu ft. ib. joules kg.-cal. kg.-meters kw. hr. P.C.U.* cm. atm. ft. of water Ib./sq. in. Ib./sq. ft. kg./sq. meter atm. in. Hg. cm. Hg. kg./sq. meter Ib./sq. in. Ib./sq. ft. cm./0 C. dynes poundals ib. tons (short) Btu ft. ib. kg.-cal. kw. hr.
g
*
0635262
TOWOLDMON0040379 WATER_PCB-00024848
MULTIPLY
kg.-meters kg./cu. meter kg./cu. meter kg./meter kg./sq. meter kg./sq. meter kg./sq. meter kg./sq. meter kg./sq. meter kg./sq. meter KILOMETER!. KILOMETERSkm./hr. km./hr. km./Kr. km./hr. KILOWAHS KILOWATTS KILOWATTS KILOWAHS KILOWAHS KILOWAHS lew. hr. kw. hr. kw. hr. kw. hr. kw. hr. kw. hr. LITERS LITERS LITERS LITERS LITERS liters/gram mol. liters/hr. liters/kg. liters/min. Ilters/mln.
ENGINEERING CONVERSION FACTORS
BY
5.165 x 101.0 X I0~s 0.06243 0.6720 9.678 x 107.355 x 10-' 3.281 x 10-' 2.896 x 100.2048 1.422 x 103.281 x 10' 0.6214 27.78 54.68 0.9113
16.67 56.92 4.425 x 10' 737.6 1.341 14.34 1 X 10s 3.413 x 10' 2.655 x 10' 1.341 3.6 x 10' 860.5 1.895 x 10' 1 x I03 0.0353 61.02
0.2642 1.057 16.02 0.2778 0.01602 6.0 x 10' 5.885 x 10 J
.
70 OBI
P.C.U.* gram/cm.# Ib./cu. ft. Ib./ft, atm. cm. Hg. ft, of water in. Hg. ib./|. (. Ib./sq. in. ft. mi. cm./sec. ft./min. ft./sec. meters/min. Btu/min. ft. Ib./min. ft. Ib./sec. bp. kg.-eal./min. watts Btu ft. ib. hp. hr. joules kg.-cal. P.C.U.* cm,3 cu. ft. cu. in. gal. (U.S.) qt. (liq.) cu. ft./lb. mol. cm.3/$ec. cu. ft./lb. cm.3/hr.
cu. ft/sec.
*Pound>Cnttgrad* Unit
0635263
|
TOWOLDMON0040380 WATER_PCB-00024849
ENGINEERING CONVERSION FACTORS
MULTIPLY
llters/mln. liters/min. liters/snc. cm.* METERS METERS meters/0 C. meters/min. meters/min. meter$/min. meter*/min. meters/sec. meters/tec. meters/sec. OUNCES OUNCES OUNCES (fluid) OUNCES (fluid) oi./sq. in. POISES POUNDS POUNDS POUNDS lb. mols gas lb. of water lb. of water lb. of water/hr. lb. of water/hr. Ib./cu. ft. Ib./cu. ft. Ib./cu. In. ib./ft. Ib./ft. hr. Ib./ft. hr. Ib./gal. Ib./in. Ib./sq. ft. Ib./sq. ft.
iWEfi %jr** -r/ /A*.>-.
BY
TO OBTAIN" ^ ' '
15.851 4.403 x I0-S 32.8 3.281 39.37 1.824 1.667 0.05468 0.06
0.03728 196.8 3.6 2.237 28.35 0.0625 1.805 0.02957 1.732 I4.448 x I05 453.6 32.17 379.4 0.01602 0.1198 2.669 x 101.997 x IO-> 0.01602 16.02 27.68 1.488
4.13 x I0~3 0.413 0.1198 178.6 0.01602 4.882
gal./hr. gal./sec. cu. ft./sec. sq. ft. ft. in. ft./ F. cm./sec. ft./sec. km./hr. mph ft./min. km./hr. mph
grams ib. cu. in. liters in. of water gram/cm. sec. dynes grams poundals cu. ft. gas (60 F. at 1 atm.) cu. ft. gai.
cu. ft./min. gal./min. grams/cm.3 kg./cu. meter grams/cm.3 kg./meter grams/cm. sec. centipoises grams/cm.3 grams/cm. ft. of water kg./sq. meter
: I
,
Ah | ^'
i j
t ' * :
f
0635264
TOWOLDMON0040381 WATER_PCB-00024850
ENGINEERING CONVERSION FACTORS
%
H'
MULTIPLY
BY
TO OBTAIN
Ib./sq. ft.
6.944 x I0-3
Ib./sq. in.
Ib./sq. in. Ib./sq. in.
0.06804 2.307
atm. ft. of water
.
Ib./sq. in.
2.036
in. Hg.
Ib./sq. in.
51.7 mm. Hg.
Ib./sq. in.
703.1
kg./sq. meter
Ib./sq. in.
144 Ib./sq. ft.
REFRIGERATION--STD. TON
200
Btu/min.
SQUARE CENTIMETERS
1.076 I0-"
sq. ft.
SQUARE CENTIMETERS
0.1550
sq. in.
SQUARE FEET 929 sq. cm.
SQUARE FEET 144 sq. in.
SQUARE FEET
0.0929
sq. meters
SQUARE INCHES
6.452
cm.2
SQUARE INCHES
6.944 I0~3
sq. ft.
SQUARE INCHES
6.452 x 10-'
sq. meters
SQUARE KILOMETERS
1.076 10'
sq. ft.
ft
SQUARE KILOMETERS
0.3861
V SQUARE METERS 10.76
sq. mi. sq. ft.
temperature 0 G. 273
1.0
abs. temp. K.
temperature 0 C. 17.8
1.8
temp. 0 F.
temperature 0 F. 460
1.0
abs. temp. R.
temperature 0 F. --32
0.5555
temp. 0 C.
TONS (long)
1.016 x HP
kg.
TONS (long)
2.24 x I0l
lb.
tons (metric)
\ x 10*
kg.
tons (metric)
2.205 x 10*
lb.
tons (short)
907.2
kg.
tons (short)
2 x I0:<
ib.
tons (shortj/sq. ft.
9.765 x I0J
kg./sq. meter
tons (short)/sq. tt.
1389
Ib./sq. in.
tons (short)/sq. in.
1.406 x 10"
kg./sq. meter
tons (short)/sq. in.
2 x 10*
Ib./sq. in.
tons of refrigeration
See refrigeration
WATTS
0.05692
8tu/min.
WATTS
1 x I07
ergs/sec.
WATTS
44.26
ft. Ib./min.
HHBBIBKfwmsm ' ~
0635265
TOWOLDMON0040382 WATER_PCB-00024851
n
ENGINEERING CONVERSION FACTORS
MULTIPLY
WATTS WATTS WATTS WATTS WATT HOURS WATT HOURS
WATT HOURS WATT HOURS WATT HOURS WEEK WEEK WEEK YEARS (common)
-
' 4 ^ -f*Y> \ * BY
TO OBTAIN
0.7376 1.341 10-' 0.01434 1.0 x I0-3 3.413 2.655 x 103 1.341 x I0-3 0.6605 367.1 168 1.008 x I0` 6.048 x 10s 8.76 x 10s
ft. Ib./sec. hp. kg.-cal./min. kw. Btu ft. lb. hp. hr. kg.-cal. kg.-meter hr. min. sec. hr.
STEEL PIPE DIMENSIONS--CAPACITIES AND WEIGHTS'
Nominal Outside
Well
pipe dlam. Schedule thick
size, In.
In.
No. ness, In.
K
0.340
40
H
0.67i*
40
W
C.84('
40
V.
1.050
40
1
1.311-
40
1/.
1.66(i
40
m
1.990
40
2
2.375
40
2A
2.87!'
40
3
3.500
40
3* 4.000 40
4
4.50(i
40
5
5.563
40
S
6.625
40
6
8.62!.
40
10 10.75 40
12 12.75 40
.088 .091 .109 .113 .133 .140 .145 .154 .203 .216 .226 .237 .258 .280 .322 .365 .406
Based on A. S. A. Standards B30.10
Inside dlam.,
in.
Cresssectional
erea metal, sq. In.
Inside sectional
sq. ft.
.364 .493 .622 .624 1.04S 1.360 1.610 2.067 2.469 3.066 3.548 4.026 5.047 6.065 7.981 10020 11.938
.125 .167 .250 .333 .494 .669 .799 1.075 1.704 2.228 2.680 3.173 4.304 5584 8.396 11.90 1577
.00072 .00133 .00211 .00371
.00600 .01040 .01414 .02330 .03322 .05130 .06870 .08840 .1390 .2005 .3474 .5475 .7773
Circumference, ft., or surface sq ft. per ft , ol
length
Outside Inside
Capacity at 1 ft. per sec. velocity U. S. Lb. per br. gal. per water min.
.141 .177 .220 .275 .344 .435 .496 .622 .753 .917 1.047 1.178 1.456 1.734 2.258 2814 3.338
.0954 .1293 .1630 .2158 .2745 .362 .422
.542 .647 .804 .930 1.055 1.322 1.599 2.090 2.620 3.13
.323 .596 .945 1665 2.690 4.57 6.34 10.45 14.92 23.00 30.80 39.6 62.3 90.0 165 7 246.0 349 0
161.5 298.0 472.5 832.5 1,345.0 2,285.0 3,170.0 5.225.0 7,460.0 11,500.0 15.400.0 19,800.0 31,1500 45.000.0 77,850.0 123.0000 174,5000
Weight ol pTpe per It.
lb
.43 .57 .85 1.13 1.68 2.28 272 3.66 5.80 7.58 9.11 108 147 190 28 6 405 536
t
0635266
TOWOLDMON0040383 WATER_PCB-00024852
TYPICAL APPLICATIONS FOR ------fhOT LIQUID HEATING SYSTEMS.
Indirect liquid heating with THERMINOL FK systems is recommended wherever lowpressure, high-temperature proc essing-requiring safe, uniform delivery of heat--is needed. Here are a few typical applications.
CHEMICAL PROCESSING . . . especially where flammable materials are handled.
VARNISHES AND RESINS PROCESSING ... where a single "circuit" with multiple users and varying temperatures is desirable.
PLASTICS AND RUBBER MOLDING . . . where uniform heating, rapid temperature flux, and pin-point control is essential.
BITUMINOUS MATERIALS HEATING ... for maximum safety where explosive gases and volatile fumes occur.
FOOD PROCESSING ... for controlled, quality "cooking" of potato chips, pre-cooked soups, other foodstuffs.
MATERIALS CONVERSION ... to heat corrugating rolls, crimping presses, calenders,
METALS TREATING OVENS ... for heat-treating metals such as titanium and vanadium; for "seasoning" weldments, castings and forgings.
MALT COOKING AND LIQUID DISTILLATION . . . for efficient indirect heating of distillation equipment.
0635267
|
TOWOLDMON0040384 WATER_PCB-00024853
V
i
^hermljriLaJs, fr
SAFETY OF HANDLING
J
On the basis of animal toxicity studies,
THERMINOL FR may be considered only
I slightly toxic from the standpoint of acci dental massive skin exposure or accidental j ingestion. Similarly, single exposures to high 1 concentrations of vapors (when heated suffi;! ciently to volatilize) or high concentrations j of decomposition products (if the fluid is j accidentally discharged into the fire chamber) 1 are not serious hazards because the irritating i character of such concentrations preclude vol* j untary exposure.
s Repeated or prolonged skin exposure should j be avoided since THERMINOL FR acts as ). a solvent for fats and oils of the skin. Re't moval of these natural, protective barriers can lead to drying and chapping such as j occurs with exposures to paint thinners. More \ important, THERMINOL FR may be ab1 sorbed if it is allowed to remain on the unbroken skin. For these reasons, we recom7 mend that the skin be washed with soap and i water if there is contact, A skin burn resulting 1 from accidental contact with hot fluid should ' be treated in the normal manner for any
thermal burn due to hot oils.
j Because of its low vapor pressure, there is no
. significant vapor inhalation hazard when J THERMINOL FR is at room temperature. ; For example, there is no vapor exposure prob lem while transferring the fluid from its ship : ping container to the heat transfer system. * On the other hand, the vapors emitted by
THERMINOL FR heated to elevated temi peratures are injurious on prolonged exposure. * It is indicated that the "threshold limit value" ' or atmospheric vapor concentration which ` cannot be safely exceeded (on a daily basis)
is 0.5--1.0 milligrams of THERMINOL FR ; vapor per cubic meter of air in the workroom. S In heat transfer installations, the fluid must * be used in a closed system free from leaks 1 with the expansion tank vented to the out\ doors. Accordingly, there should be little or ` no opportunity for workers to come in con