Document 2MkLVJYoeknojKBd2NQbOO86

TECHNICAL SPECIFICATIONS CertairileedlH SPECIFICATIONS CLASSIFICATION: ~ A/C Standard Purchasing Specification T.C.O. REF- NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group 1 supersedes: 564 1 DATE OF ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings 1.0 General The A/C Sewer Fittings described in this specification are of CertainTeed's design and are compatible with CertainTeed's A/C Sewer Pipe. They employ the same design criteria as CertainTeed's own fittings fabrication and use existing sewer rings and certa-spacers (also of CertainTeed's design). 2.0 Use The sewer fittings covered by this specification are designed for Use with A/C Sewer Pipe. Described are Couplings, Tees, Wyes, Elbows and various adaptors. 3.0 Materials 3.1 All fittings shall be made from material which meets the requirements of ASTM C644, or ASTM C428 and Federal Specification SS-P-331d (latest issues). This includes composition and all chemical and physical requirements. Vendors who purchase materials for fabrication shall assume the respon sibility of assuring that the materials they purchase meet these speci fications. A file of records or certifications of conformance to the above ASTM's and Federal specification, for materials made or purchased by the fabricator, shall be maintained for inspection upon request. 4.0 Lot Size For sampling and inspection purposes, a lot shall be defined as the quantity of all fittings shipped on one order, received at one time, and identified by a Purchase Order Number. PRCPARID BY: approved by: R *D MPG. 3*&. 2-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE Dll SALES I.E. CTD015213 Page 2 5.0 Requirements 5.1 Special After approval of this specification, no change in the design or dimensions shall be made without authorization, in writing, from the A/C Standards/Quality Control Department of P&PG. When such a change is authorized, the changes shall be recorded in a revision of the specification. The manufacturer shall notify P&PG's Purchasing Department when such an authorized change is actually placed into effect. 5.2 Manufacturers/Fabricators Inspection The vendor is responsible for removing damaged/defective fit tings from each shipment before shipment is made. All fittings are to be shipped on a first-in first-out basis, i.e. oldest fittings shipped first. 5.3 Manufacturers/Fabricators Control Data The manufacturer/Fabricator shall keep records on all aspects of his production including dimensional and physical tests on the fittings. 5.4 Appearance and Workmanship of Materials Prior to Fabrication The following definitions and requirements are applicable to finished product quality. They are significant due to a) difficulty in assembling, b) failure in service, c) require ments of outside agencies, d) for cosmetic reasons. All coup lings and fittings must conform to these requirements. 1. Damaged Pipe or Coupling Material Any outside surface irregularity that give an unsatisfactory appearance. Usually occurs from mishandling. Refers to the outside unmachined area. "Tray Damage", "Flats", and "Board Marks" are some varieties of Damaged Pipe or Coupling material, as are "Gouges" (depressions) on the outside surface. A. Reject if inside diameter at depression or protrusion varies by over 3/16" from adjacent diameter, or if from 1/16" to 3/32" and length of depression or pro trusion exceeds diameter. B. Reject if depression penetrates over 1/8" on outside surface. CTD015214 TECHNICAL SPECIFICATIONS CertainTeedlH CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O- REF. NO. 1 SPECIFICATION NO: 564 PAGE NO.: 3 SUPERSEDES: DATE OF ISSUE: MAR 8 13/3 DESCRIPTION: Outside Purchased A/C Sewer Fittings C. Examine for cracks, Reject if any cracks regardless of size. 2. Rough Bore A torn section on the inside surface; a portion of the inside surface with a rough texture. "Pulled Bore" is also grouped in this definition. The distinction is in the situation that caused the defect and in the direction of the roughness. A. Reject if depth exceeds 1/8" and/or area in square inches exceeds 2X pipe diameter in inches, or extends over 1/3 or more of circumference. B. Look also for delaminations 3. Cracks A break in any surface of the pipe or coupling material without separation, such that the length is determinable, the width is negligible, and the depth is not visibly ascertainable. A "hair line crack" is more difficult to observe. It resembles "crazing" in a coffee cup. A. Accept hairline cracks or crazing in water marked area. B. Reject any other crack at any location. 4. Delaminated A separation of one or more layers comprising the pipe or coupling material structure, usually visible at the ends. "Loose skin laminations" are visible on the outside surface. ("Cracks" are usually observed as extending in from surface of barrel or bore, while delaminated is usually observed as parallel with surface of barrel or bore.) CTD015215 PREPARED BY: APPROVED BY: * a> D 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO RE O^TIsS^TRIBUuTtK to uUNAUTHORIZED PERSONNEL. Page 4 A. Accept if delaminations are next to inside surface and within 1/16" of inside surface on sizes 6" or less; within 1/8" on sizes 8" and above. 5. Water Marks A discolored, marbled appearance on the inside surface of the pipe or coupling stock with slight and tiny cracks, fissures, or flaking, or visible material separation. A. Accept hairline cracks. B. Reject if marking covers entire diameter. C. Examine water-marked pipe or coupling to determine if any sub-surface delaminations, and reject if they exist. (Destroy one if necessary to determine this.) 6. Silica Spots Any non-homogenized portion of the cement-silica-fiber blend visible on the inside surface or on the machined area of the pipe. Sometimes called "white spots" or "lime spots". A. Acceptable on inside surface. B. Reject if any are found on outside surface in area from pipe end to within %" of inner edge of O.D.j^ zone. 7. Dents Smooth, externally caused bulges or recesses on the inside surface of the pipe or couplings. A. Reject if inside diameter at dented area varies by 3/16" or more from adjacent inside diameter on all sizes. B. On any dent look for cracks or structural failure and reject if noted. 8. Gouges A scooped out section on the barrel or bore of the pipe or on a machined surface of pipe or couplings. A. Reject if depth exceeds 3/16" or length exceeds diameter on all sizes. B. No gouge allowed on any machined surface. CTD015216 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertairileedlH CertainTeed Corporation Pipe and Plastics Group description: A/C Standard Purchasing Specification T.CO. REF. NO. 2 SPECIFICATION NO: 564 PAGE NO.: 5 SUPERSEDES: March 8, 1979 OATC OF ISSUE: JUL 1 7 19/9 Outside Purchased A/C Sewer Fittings 9. Not Machined Clean Surface irregularities on the machined surface that may adversely affect assembly, handling, or sealing, or are of poor appearance. , This definition applies also to "Bad Cut", "Chatter", "Chipped", and some "Flaking". These terms are more precisely descriptive. A. Reject if machined surface is not free of circumferential or helical grooves or scratches. 10. Damaged Ends Breaks, chips, or flaking in the beveled area of the pipe. A. Reject if any chips or flaking on outside edge that extend back over %" bevel from edge, or extend over V around the perimeter at any one location or are deeper than 1/8". B. Reject on inside edge for any chips of length or width of over 1" or of depth over 1/8". 11. Foreign Material Anything other than cement, silica, or fiber noticed on the surface of the pipe. A. Reject if found. 5.5 Dimensions The dimensions should be as shown on the following pages: t 6.0 Finished Fitting Requirements In addition to the material and dimensional requirements, finished-fittings shall be checked for the following: 1) Evidence of Fishmouth on those fittings which are prebelled. CTD015217 PREPARED BY: APPROVCO BY: ^3^ 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT R D MFG. SALES i.E. JA NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL OTHERS Page 6 2) Presence, location and straightness of Certa-spacer where applicable. 3) Correctness, completeness and legibility of markings. 4) The workmanship of the epoxy bond on fabricated fittings. 5) Finished fittings shall be free of loose or hanging chips and lace curtains. 6) There shall be no sharp edges 7.0 Acceptance and Rejection P&PG reserves the right to reject any lot. or lots found not conforming to the requirements of this specification. Such rejection shall be accomplished within a reasonable period following date of delivery. In the event of a rejection, the vendor shall be given the opportunity to inspect representative samples of the rejected material. The vendors must express his desire to inspect rejected material within seven (7) days after notification of the rejection, and the physical inspection must be performed within 30 days. 8.0 Packaging Fittings shall be shipped in cartons, crates, shrink wrap pallets, etc. of the vendors design, provided they are of suitable size and strength to prevent damage from normal shipping and handling and facilitate stacking. Package shall be labelled as per its contents. 9.0 Marking All markings shall be stamped or stencilled in Block letters in green ink. The ink shall be able to withstand weathering. The letters shall be large enough to be easily visible, and readable to the naked eye. A marking code letter has been assigned to each vendor which is to be part of each items marking. Also, each vendor shall stamp or stencil on each item the country in which it is manufactured. Couplings , At the approximate center around the coupling, the following shall be shown: CERTAINTEED SIZE - CUSS FLUID-TITE SEWER Note: The last line shall read FLUID-TITE CG-S Sewer for coupling markings on 15 and 21 inch until the new FLUID-TITE design change is made. CTD015218 TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. 1 SPECIFICATION NO: 564 PAOE NO.: 7 supersedes: date of issue: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings Fittings Fitting markings are shown on the individual pages along with the fitting. 10.0 Special Information 1) Rings and Certa-spacers as required will be supplied to the vendor via CertainTeed*s Ambler plant (only those fittings which are prebelled by the vendor or otherwise specified require rings and certa-spacers). 2) All fittings are to be shipped to the Ambler plant for inspection purposes. No fittings shall be shipped directly to a job without authorization from CertainTeed1s Marketing and Quality Control Departments. 3) This specification and the information it contains is the property of CertainTeed. Under no circumstancesshall this specification or dimensional details herein be released to any unauthorized persons. CTD015219 PREPARED BY: APPROVED by: "YML> * D 02-10-00*3 (R927) 12/76 CONFIO NTIAL DOCUMENT - NOT TO BE Of.TRli OTHERS 085 :d to unauthorized personnel Standard Pipe Page 8 Pipe lee. Mom. Inches I.D." O.D.i" O.D.?" 4 4.00 4.62 4.78 5 5.00 5.66 5.82 6 6.00 6.66 6.82 8 8.00 8.80 8.96 10 10.00 10.89 11.05 12 12.00 12.99 13.15 14 14.00 15.07 15.23 15 15.00 16.11 16.27 16 16.00 17.15 17.31 18 18.00 19.23 19.48 20 20.00 21.29 21.54 21 21.00 22.37 22.53 24 24.00 25.51 25.76 XH 11 Class .06" .06" Min. 1500 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.50 1.15 1.15 1.15 1.50 1.15 2.09 2.09 2.09 2.44 2.61 2.81 3.06 3.25 3.06 3.81 3.81 3.75 3.81 .20 4.81 .22 5.91 .24 6.91 .27 9.00 .30 11.14 .33 13.24 .36 15.32 .39 16.36 .41 17.42 .44 .48 .52 .56 B.O.D." Min. Class 2400 Class 3300 Class 4000 4.87 5.98 7.04 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 5.01 6.20 7.22 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.88 22.94 26.12 11.45 13.54 15.64 16.72 17.74 20.00 22.10 23.18 26.36 Class 5000 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 Class 6000 20.43 22.55 23.63 26.79 Class 7000 20.63 22.77 23.85 27.03 Tolerance: 0 .D.i" and 0.D.2M l through 16" + .02" 18" through 24" .03" Pipe Size, Inches 4. 5 and 6 8 10 and 12 0C 2 14 16 16 14 and 16 18, 20, & 24 15 21 18 20 15 18 pll .06" .50 .55 .62 .62 .75 1.00 1.00 <f-- < - SPACER Bend see^J Certa-spacer bands are to be applied to pips ends as shown above for t' e prebelled end of Wyes an Tees, and one end of each elbow. The band should b,e against the O.D2 shoulder. (Bands may be heated to ease placement.) CTD015220 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertainTeed IH A/C Standard Purchasing Specification T.C.O. REF- NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group 1 SUPERSEDES: 564 9 DATE OF ISSUE: MAR 8 197S description: Outside Purchased A/C Sewer Fittings Standard Coupling T~ actOr- 1-- AT e 15" and 21" Coupling Sizes only All Couplings except 15" and 21" NT'S R -- f -j - --6 -- Coupling Size. In. A" 4 5.24 5 6.26 6 7.28 8 9.55 10 11.64 12 13.74 14 15.87 15 16 17.95 18 20.48 20 22.54 21 24 26.70 A" 15 16.81 21 23.07 B" 4.71 5.75 6.75 8.89 11.00 13.10 15.19 17.27 19.36 21.42 25.64 Bi" 16.43 22.69 H" +.00" -.06" 3.50 3.50 3.50 4.00 4.75 4.75 5.25 7.13 5.25 6.50 6.50 8.13 6.50 B?" 16.24 22.50 Dimensions min. L" +.25" -.00" 4.75 4.75 4.75 5.75 6.50 6.50 7.00 8.-90 7.00 8.25 8.25 9.90 8.25 Class 1500 5.92 7.06 8.12 10.50 12.75 15.00 17.15 18.26 19.31 Class 2400 B.O.P." +.25" -.00" Class 3300 Class 4000 Class 5000 5.92 7.06 .12 10.50 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 6.00 7.14 8.20 10.59 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 13. 00 15. 24 17. 48 18. 61 19. 68 22. 09 24. 15 25. 26 28. 69 13.00 15.24 17.48 18.61 19.68 22.09 24.15 25.26 28.69 Class 6000 22.47 24.67 25.81 29.15 Class 7000 22.47 24.67 25.81 29.15 Tolerance: A and B - 4" through 16" + 025" 18" through 24" +.040" A. Bi, and B2 - 15" +.050" -.020" 21" +.040" Coupling Size , In. 4". 5" 6 6" 8", 10", 12", 14", 16" 18", 20", 24" 15", 21" F" Min. .50 .75 .75 .76 C* + .04" -.00" .50 .62 1.00 i.n J"* + .03" -.00" .35 .50 .63 .42 R"* +.01" .156 V ,, +.02" OC +2 -.00" 13 B +2 .200 18 .250 12 .060 .18 45 CTD015221 * Tolerance 15" and 21" G" - +.03" J" - +.00" -.04" R" - Max. PREPARED BY: approved by: _ r0 _ MFO. SALES I.E. / otte OTHERS ED TO UNAUTHORIZED PERSONNEL Page 10 SLEEVE ADAPTOR Dimensions Pipe Size, Inches 4 5 6 I.D.2" .030" 5.45 6.50 7.50 B.O.D." Min. 6.42 7.50 8.67 Marking Example: CEKTAINTEED 4"SEWER SLEEVE ______ADPT. OTD015222 TECHNICAL SPECIFICATIONS CertainTeed El CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: FADE NO.: 1 SUPERSEDES: 564 11 DATE <yr issue: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings SLEEVE ADAPTOR (A/C ROUGH BARREL TO CLAY) t* i _ 6 +00-50 ** r 7 W., BOD ID Marking Example: CERTAINTEED SLEEVE ADPT. A.C. R.B. - CLAY 6" SEWER 15/24/3300 Pipe Size, Inches 4 6 Dimensions I.D." +.100". 6.00 8.50 B.O.D." Min. 7.00 9.50 CTD015223 PREPARED BY: approved by: * 1D MFO. SALES I.E. OTHERS S____________ Qt> 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO B( DISTRIBUTED TO UNAUTHORIZED PERSONNEL. Page 12 ADAPTOR BELL AND SPIGOT Pipe Size, Inches 4 5 6 Dimensions Nom. i-p-r 4.00 5.00 6.00 i.d.2" -.030" 5.45 6.50 7.50 b.o.d." Min. 6.42 7.50 8.67 Note: 1. Refer to standard pipe ends for O.D.^ and bevel machining. Marking Example: CERTAINTEED 5'SEWER ADPT. BELL AND SPIGOT CTD015224 TECHNICAL SPECIFICATIONS Page 14 DUPLEX ADAPTOR COUPLING CLAY SPIGOT TO A/C M.E. Pipe Size Inches 4 5 6 Dimensions Nom. i.D.r I.D.2" +.10" 4.00 5.00 6.00 6.25 7.25 8.50 B.O.D." Min. 7.19 8.23 9.54 Marking Example: CERTAINTEED DUPL. ADPT. CPLG. CLAY SPIGOT - A.C.M. 4" SEWER 15/24/3300 Note: 1. Refer to s tandard coupling for machined dimensions not shown. CTD015226 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertainTeed El CertainTeed Corporation Pipe and Plastics Group A/C Standard Purchasing Specification T.C.O. SEP. NO. SPECIFICATION NO: PAOE NO.: 1 SUPERSEDES: 564 15 OATS OF ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings DUPLEX ADAPTOR COUPLING CONCRETE TO F.T. SEWER Marking Example: CERTAINTEED DUPL. ADPT. CPLG. CONCRETE - FT. SEWER 6" SEWER 15/24/3300 Pipe Size, Inches 4 6 Dimensions Nom. I.D.i" 4.35 6.35 I.D.2" +.10" 6.35 8.98 B.O.D. Min. 7.29 10.02 Note: 1. Refer to standard coupling for machined dimensions not shown. CTD015227 PREPARED BY: APPROVED BY: R *O MFC. SALES I.E. 10-0023 (P927) USs 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE OISTRIBUTITd to unauthorized personnel OTHERS Page 16 DUPLEX ADAPTOR COUPLING CAST IRON TO SEWER Pipe Size, Inches 4 5 6 DimensIons Nom. I.D.i" I.D.2" 1.030" 4.35 5.35 6.35 5.45 6.50 7.50 B.O.D." Min. 6.42 7.50 8.67 Note: Refer to standard coupling for machined dimensions not shown. Marking Example: n CERTAINTEED 4 DUPLEX ADPT. CPLG. Cl TO A/C SEWER CTD015228 TECHNICAL SPECIFICATIONS CertairfleedH SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group 1 SUPERSEDES: 564 17 OATE OF ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings COUPLING END PLUG .375"A/C CIRCULAR DISC. 2-HOLES 50" Dia. ISO O.C. Marking Example: CERTAINTEED CPLG. END PLUG 4" SEWER 15/24/3300 Pipe Size, Inches 4 5 6 Nom. I.D." 4.00 5.00 6.00 B.O.D." Min. 4.87 5.98 7.04 A/C Circular Disc. .375" x 4.70" O.D. .375" x 5.75" O.D. .375" x 6.75" O.D. Note: i. Refer to standard pipe for O.D.i and bevel. 2. A/C1circular disc shall be supplied by the A/C plant. 3. Epoxy A/C disc in place. PREPARED BY: CTD015229 APPROVED BY: R *D MFG- 1 SALES t.E. Ot|s OTHERS Page 18 Sewer Tee Nipple For Field Cut Mains Nipple Size, Inches 4 5 6 Nom. I.D." 4.00 5.00 6.00 B.O.D." Min. 5.50 6.50 7.50 O.D.," +.02rt 4.62 5.66 6.66 0.D.2" 02" 5.12 6.12 7.12 Lc" .06" 5.00 5.00 5.00 Nipple Size, Inches 6 8 10 12 14 15 16 18 20 21 24 Contour Cut Diameter 4", 5" & 6" Branch Size (All Classes) 6.00 8.00 10.00 12.00 14.00 15.00 16.00 16.00 20.00 21.00 24.00 < Marking Example: CER1AINTEED SEWER IEE NIPPLE 4" SEWER x 12" CTD015230 TECHNICAL SPECIFICATIONS END CAP Page 20 Harking Example CERTAINTEED END CAP 10" 15/24/3300 S HVY.________ Pipe Size Inches I.D." Horn. 4 4.00 5 5.00 6 6.00 8 8.00 10 10.00 12 12.00 14 14.00 15 15.00 16 16.00 18 18.00 20 20.00 21 21.00 24 24.00 L" .13" 3.13 3.13 3.13 4.00 4.38 4.63 4.88 5.83 4.88 5.75 5.75 6.58 5.75 M" . 1.13" 2.38 2.38 2.38 3`.00 3.38 3.33 3.63 4.58 3.63 4.25 4.25 5.08 4.25 X" Min. .38 .38 .38 .50 .50 .63 .63 .63 .63 .75 .75 .75 .75 Hi" + .00" -.06" 1.63 1.63 1.63 1.88 2.26 2.38 2.63 3.08 2.63 3.00 3.00 3.71 3.00 B,,0.D. +.25" -.00" Class 2400 5.92 7.06 8.12 10.50 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 Heavy 6.00 7.14 8.20 10.59 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 Extra Heavy ... -- ---- -- 13.00 15.24 17.48 18.61 19.68 22.09 24.15 25.26 28.69 Class 6000/ 7000 A/C Circular Disc Thick Diam. -- -- -- -- ----- -- ------- 22.47 24.67 25.81 29.15 .375 .375 .375 .500 .500 .625 .625 .625 .625 .750 .750 .750 .750 4.60 5.65 6.65 8.79 10.90 13.00 15.09 16.15 17.17 19.26 21.32 22.40 25.54 Note: 1. Refer to standard coupling for machined dimensions not shown. 2. A/C circular disc shall be supplied by the A/C plant. 3. Epoxy A/C disc in place. CTD0^2# TECHNICAL SPECIFICATIONS CertainTeed Ef SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group 1 supersedes: 564 21 iDATE )F ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings DROP MANHOLE SECTION (------------------39.0v.0"-5*--------------------------- -- ^ i. j -i r. t T OD ID '* Marking Example: CERTAIN-TEED DROP MANHOLE SECTION 8" SEWER FOR VERTICAL USE ONLY Dimensions Pipe Size, Inches Norn. I.D. O.D." ,02" 6 5.80 6.66 8 7.80 8.80 10 9.55 10.89 12 11.45 12.99 14 13.60 15.07 15 14.45 16.11 CTD015233 16 15.50 17.15 Note: 1. This item for use in vertical position only. 2. Refer to standard pipe for bevel dimensions. PREPARED BY: fist! approved by: >Yv|& aO 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE MFO. SALES I.E. Ofe tTRIBUTEO TO UNAUTHORIZED PERSONNEL OTHERS MANHOLE STUB Page 22 Marking Example: Dimensions CERTAIN-TEED MANHOLE STUB 16" CLASS 2400 SEWER Pipe Size. Inches 6 8 10 12 14 15 16 18 20 21 2A Class Class 1500 2400 6.91 9.00 11.14 13.2A 15.32 16.36 17.A2 7.04 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 +.25" - .00" Class 3300 Class 4000 Class 5000 7.22 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.88 22.94 26.12 11.45 13.54 15.64 16.72 17.74 20.00 22.10 23.18 26.36 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 Class 6000 20.43 22.55 23.63 26.79 Class 7000 20.63 22.77 23.85 27.03 Note: 1. Refer to standard pipe for machined dimensions not shown. CTD015234 TECHNICAL SPECIFICATIONS ELBOWS 11%, 22%, 30. 45. and 90 ELBOWS Page 24 Refer to standard coupling for machining not shown. For fabrication of 90 elbows, add fillet to 45 elbow. (Tolerance on 90 elbows 5) Epoxy all adjoining surfaces. Remove excess on inside for smooth surface. N=2.00" +.062" All Pipe Sites - 1500, 2400. and 3300 00 0*2 030*50 ll*t Elbowe 22\s Elbows 30 Elbows 45 Elbows 90 Elbows 5 5/8 11 1/4 15 22 1/2 22 1/2 11 1/4 22 1/20 30 45 45 Pipo S1 z o , Inches 4 5 6 Nom. T.D." 4.60 5.M b.60 B.O.D." +.25" -.00" 5.92 7.06 8.12 < + .25" L" -.00" L/2" 10.75 10.75 10.75 5.375 5.375 5.375 LC" 5.375 5.375 5.375 Marking Examples CERTAIN-TEED 300 EL 6" Sewer 15/24/3300 +.125" Y" -.000" 2.915 2.455 2.015 + .125 X" -.000 7.835 8.295 8.735 CTD015236 TECHNICAL SPECIFICATIONS Certairileed El SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group DESCRIPTION: 1 SUPERSEDES: 564 25 OATE OF ISSUE! MAR 8 1979 Outside Purchased A/C Sewer Fittings 45 WYE FITTING Hirfctcg Buapl.i COTAIN-TEED 45 WYE 4"S.4"S. 15/24/3300 Itduelnt N" 2.00" 4 .041* Pipe Sice, Inche Nod, S.O.D-i" <r Nod. +.25" B.O.D..** +.030** I.D.l" -.o<r Kin. -.020" 5x4 5.60 4.00 7.06 4.87 4.89 6x4 6.60 4.00 8.12 4.87 4.89 6x5 6.60 3.00 8.12 5.98 6.00 Pltn.lon. Jl. 7.63 8.50 8.50 r" 12.25 13.00 13.75 t.A." 11.16 12.56 12.56 , L" +.00" -.50" 15.25 17.00 17.00 L.C." 4.06" 11.25 11.30 12.40 L.B." .06" (.38 6.43 5.42 L+D." .06" 4.18 3.05 4.27 L.E." .06" 11.08 11.93 12.73 Non-Reducing Pipe Sice, Norn. Inche l.Dl*' 4x4 4.60 5x5 5.60 6x6 6.60 Nod. 4.00 5.00 6.00 I.O.D.i* +.25" -.00" B.O.D.j" Hln. rm 5.92 7.06 6.12 4.87 5.98 7.04 11.50 12.75 14.25 V 6.88 7.63 8.50 L.A." 9.84 11.16 12.56 LH + .00*' .50" 13.75 15.25 17.00 L.C." *.06" 9.80 10.70 u.88 L.B." 4.06" 4.93 4.72 4.84 L.D." .06" 3.43 3.40 3.51 L. E." .06" 10.33 11.86 13.49 Noter 1. Refer Co standard coupling Mchlnlng for Min Mchlnlng. 2. Refer to standard pipe for Mchlnlng diaenalon not shown. CTD015237 pbcabio by: fa# APPROVED by: B ,D MFO. 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE Dl SALES I.E. 0^ UNAUTHORIZED PERSONNEL OTHERS Page 26 5x4 5.60 4.00 7.06 4.67 4.89 7.65 12.25 11.16 6x4 6.60 4.00 6.12 4.87 4.89 8.50 13.00 12.56 6x5 6.60 5.00 6.12 5.98 6.00 8.50 13.75 12.56 Hon-Reducing Pipe Sice, Non Inches I.D. Hob. LS.-JT I.O.D..1 +.25" -.00*' R.O.D., Min. L.A.* 4x4 4.60 4.00 5.92 4.87 11.50 6.86 9.94 5x5 5.60 5.00 7.06 5.98 12.75 7.63 11.16 6x6 6.60 6.00 8.12 7.04 14.25 8.50 12.56 Roce; 1. Refer to standard coupling neehlnlng for main machining. 2. Refer to standard pipe for machining dimensions not shown. 3. game branch both sides of main. 4. Brandies to be 110 apart. L" +.00" -.50" 13.75 15.25 17.00 15.25 17.00 17.00 L.C." A. 06" 9.80 10.70 11.68 11.23 11.30 12.40 L.B." *.06" 4.93 4.72 4.84 6.36 6.43 5.42 L.D." ,06" 3.43 3.40 3.51 4.18 5.05 4.27 L.E." ,06" 10.33 11.66 13.49 11.08 11.95 12.73 TECHNICAL SPECIFICATIONS CertairifeedH SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAOE NO.: CertainTeed Corporation Pipe and Plastics Group 1 SUPERSEDES: 564 27 OATE OF ISSUE: MAR 8 1979 DIKRimON: Outside Purchased A/C Sewer Fittings 60 WIE FITTING Pipe Size Inches 6xh 6x5 6x6 Nom. I.D.-," 6.60 6.60 6.60 Non. I.D.2,,-" h.00 5.00 B.O.D.j" +.25" -*qq B.O.D.," Min. 8.12 L .87 8.12 5.98 6.008.12 7.OU G" L" +.03" +.00" -.02" -.50" La" F" li.89 17.00 10.9lt 10.75 6.00 17.00 11.h2 12.00 7.06 17.00 11.88 12.75 v +.06" 9.37 10.1U 10.77 LP" 8.60 9.08 9.5U Notet Refer to Standard Pipe and Coupling for machining dimensions not shown. prepareo by: 02-1 approved mr: " .o MFO. ( SALES I.E. CM OTHERS TEE FITTING Page 28 Harking Exanple: CERTAIN-TEED TEE 4S.x4"S. 15/24/3300 Inducing R" . i.oo" + <062.. ripe Sice, Inches 5x4 6x4 6x5 Norn. h*-ll 5.60 6.60 6.60 Ron. l-p-z" 4.00 4.00 5.00 B.O.D., +.25" -.00" 7.06 8.12 8.12 on-Reducina Pipe Sire, Inches 4x4 5x5 6x6 Nom. I.D.i" 4.60 5.60 6.60 Near. I.D.2" 4.00 5.00 6.00 B.O.D. +.25" -.00" 5.92 7.06 8.12 B.O.D.," Min. 4.87 4.87 5.98 L" +.00" -.50" 12.75 13.75 13.75 C" +.030" -.020" 4.89 4.89 6.00 B.O.D.,*' Min. 4.87 5.98 7.04 L" +.00" -.50" 11.50 12.75 13.75 F" 8.20 8.77 9.30 .IMat 1. War to atandard pipe for Machining dinanalona not shown, 2 lafar to atandard coupling for aachinlng dinanaiona not ahown. P" 8.77 9.30 9.30 C" +.030" -.020" 4.89 6.00 7.06 L.C.* +.06" 5.97 6.00 6.00 La" 6.375 6.875 6.875 L.C." A*06" 5.90 5.97 6.00 mi 5.75 6.375 6.875 CTD015240 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertainleedEI CertainTeed Corporation Pipe and Plastics Group A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: 2 564 29 SUPERSEDES: March 8, 1979 DATE OF ISSUE: JUL 1 7 1a/9 description: Outside Purchased A/C Sewer Fittings 1U. 22%, 30. 45, and 90 Elbows Plmcnslon* All Fire Sizes - All Classes 0C 2 2 0C 5 Non. E l\>ws 5-5/8 22* Elbows m 30<> Elbows 15 45 Elbows 224 90 Elbows 224 m 224 3CK> 45 45 Pipe SUe, Inches 6 10 12 14 15 16 18 20 21 2A 9o'* Elbovs Vlth Fillet NVorn. V +.?5"-. 00" All Classc* $,50 $.50 $.50 $.50 $.25 9.25 16.50 18.25 18.25 18.00 5.75 A.75 3.75 3.50 2.25 2.00 10.00 $.00 8.50 7.00 X" +.25" 2400 . Htfsv*/ Extra ! 13.25 1A.00 14.75 16.25 16.00 16.50 26.25 27.00 27.25 28.50 14.25 15.00 16.50 16.25 16.75 26.75 27.50 27.75 2$.00 27.00 27.75 2e.25 29.25 Harking Exao^le: CERTAIKTEED 12" 30 fx BVY. SEWTK Pipe Size, Inches 8 10 12 14 15 It 18 20 21 24 1.0. Norn, All Classes 6.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 L" 4.00" -.50" 19.50 19.50 19.50 19.50 19.50 19.50 39.00 39.00 39,00 39.00 2400 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 B.O.fc." Min. Extra Heavy 9.24 11.30 13.46 15.50 16.56 . 17.60 19.60 21.68 22.94 26.12 11.58 13.70 15.84 16.54 17.98 20.20 22.32 23.40 26.60 Vote: 1. Refer to standard pipe ends for machining dimensions not shown. ______ 6000/ 7000 --- 2, Epoxy all adjoining surfaces. Remove excess on Inside for smooth surfjcc. 3. For fabrication of 90 elbows, add fillet to center of 45 elbow. A. Epoxy fillet on *11 outside adjoining piece*. --- .5. Tolerance on 90 elbows i5. ........................ 20.63 72.77 23.85 27.03 6. Certa-spacer required on one end. PREPARED BY: /*2T APPROVED SY: R aO MFG. .-I SALES M =377 t.E. cuts 10-0023 (P927) 12/76 CONFIDENTIAL DOCUN.N1 - NOT TO BE DfSTVtlBUT ED TO UNA UTHORI2ED PERSONNEL OTHERS CTD015241 45 Wye Fitting Page 30 Main Pipe Site. Inches 8x8 10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 16 x 16 20 x 20 21 x 21 24 x 24 Non. I.D.i" All Clashes 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 26 00 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 B.O.D.l" Min. Heavy Extra Heaw 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.68 22.94 26.12 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 fc0r'0.' 7 300 _ _ _ _ 20.63 22.77 23.85 27.03 Branch ripe Site. Inches 4 5 6 6 10 12 14 15 16 18 * 20 21 24 Kon, I,D.*>" All Classes 4.00 5.00 6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 2400 4.87 5.98 7.04 9.06 11.14 13.24 15.3216.36 17.42 19.60 21.66 22.74 25.88 Heavy 4.67 5.98 7.04 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.68 22.94 26.12 B.O.D.?" Min. Extra Heavy --- 11.58 13.70 15.84 16.94 17.98 20.20 22.22 23.40 26.60 6000/7000 _ __ _ _ ___ 20.63 22.77 23. ?5 27.03 I*--- - *3.00*' 2400. tlcaw. Ext ra He*vyand 6000/7000 Main Pipe site, :Inches ft X 8 10 X 10 iz X 12 14 X 14 15 X IS 16 X 16 18 X 16 20 X 20 51 X 2k 24 X 24 Mf j __4 _5 _6 Branch Sire, InJ.rx J_0 12 j,Jt xi ll IS 20 21 24 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 59 39 39 39 39 39 39 39 39 39 39 39 39 39 39 53 52 52 52 39 39 39 39 39 39 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 78 1. roc wln .nil brooch tv.chining dlaren'lona, rclcr to elnn<iar<] ftp,, cn(), Z. Hll;ht oo-l of r-.iin ahowi. above la to bo pi obc1lod (with cert(i-.p-cor. be tore ehlpetenc. 1 or) branch Slrtj Iru Z/.00 4 4.89 5 6.00 6 7.06 9.08 10 11.16 12 13-26 14 15.34 15 16.38 16 17.44 18 19.62 20 21,68 21 22.76 C" +.0V1 -.Of *------------------------- Heavy tv. Heavy 6000/7000 4.89 6.00 7,06 9.08 * 11 32 13.48 15.52 16.58 17.62 19.62 21.90 23.05 11.60 13.72 15.86 16.96 18.00 20.72 22.34 23.63 ____ ____ -- -- ____ 20.22 22.34 * 23.68 * CTD015242 TECHNICAL SPECIFICATIONS CertainTeed H SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group DESCRIPTION: 2 SUPERSEDES: March 8, 1979 564 31 DATE OF ISSUE: JUL 1 7 1979 Kilo Site, Inches Outside Purchased A/C Sewer Fittings U" +.00" -.35" All cutset _________ ____________________ Branch Site, Inches 4 5 6 8 10 17 14 15 16 18 20 21 24 6xB 10 x 10 12 x 12 16 x 14 15 x 15 -16 x 16 IB x IB 20 x 20 .21 x 21 24 x 24 11.9 11.8 12.2 12.2 13.4 12.1 13.2 13.6 14.0 13.7 11.9 11.8 12.2 12.2 14.2 12.1 13.2 13.8 14.8 13.7 11.9 11.8 12.2 12.2 14.9 12.1 13.2 13.e 15.6 13.7 13.4 14.3 15.7 17.7 16.7 19.6 71.9 23.S 17.3 25.7 15.8 15.7 17.7 ie.2 19.6 21.9 23.6 18.8 25.7 17.2 17.7 19.6 19.6 21.9 23.8 20.4 25.7 19.2 21.3 19.6 21.9 23.8 22.0 25.7 22.1 19.6 21.9 23.8 22.7 25.7 21.1 21.9 23.6 23.5 25.7 23.9 23.8 25.1 25.7- 25.3 26.6 25.7 27.5 25.7 28.7 9 .00" tfl* -1.07" All Clcsscs 4 10.75 5 11.50 6 14.25 8 17.25 10 19.75 12 20.75 14 25.00 IS 27.50 16 27.50 18 30.50 20 34.00 21 35.00 Kiln Size, Inches 8x8 10 x 10 12 X 12 14 x 14 15 x 15 16 x 16 IB x 18 20 x 20 21 x 21 24 x 24 U" - All Classes Branch Sire. Inches 4 5 6 8 10 12 14 15 16 IS 20 21 24 16.5 17.5 19.0 20.0 21.7 21.0 24.0 25.0 25.5 27.0 16.5 17.5 19.0 20.0 22.5 21.0 24.0 25.0 26.3 27.0 16.5 17.5 19.0 20.0 23.2 21.0 24.0 25.0 27.1 27.0 19.0 20.0 22.5 25.5 25.0 23.5 32.0 35.0 28.6 37.0 22.0 22.5 25.5 26.5 28.5 32.0 35.0 30.3 37.0 23.5 25.5 28.1 28.5 32.0 35.0 31.9 37.0 27.5 29.6 28.5 32.0 35.0 33.5 39.0 30.4 28.5 32.0 35.0 34.3 39.0 31.5 32.0 35.0 35.0 39.0 34.5 35.0 36.6 39.0 37.5 38.2 39.0 39.0 39.0 42.0 In" + .00" -.06' 2400 Heavy Ex. Heavy 6000/7000 8.06 7.93 ... 10 8.55 8.36 8.02 12 7.52 7.25 6.96 14 9.01 8.79 6.38 15 10.53 10.39 10.12 16 10.47 10.25 9.80 18 10.84 10.60 10.12 20 11.35 11.09 10.56 21 11.42 11-28 10.95 24 10.76 10.47 9.89 ... ... ... 9.31 9.20 10.64 9.59 . Main Size, Inch** 6X8 10 X 10 12 X 12 14 X 14 15 X 15 16 X 16 16 r. 18 20 X 20 21 X 21 24 X 24 r" - All Classes Branch Sire, Inches 4 5 6 8 10 12 IA IS 16 16 20 21 24 2400 In" + .00" -.06 Heavy Ex. Heavy 6000/7000 14.00 15.25 16.75 18.25 21.40 19.50 21.00 14.00 16.25 19,00 15.50 17.75 19.50 21.75 17.75 19.00 20.75 22.75 23..50 18.25 20.50 23.25 24.00 25..75 27..25 21.90 22.30 24.60 26.30 28..20 79..70 29..70 19.75 22.00 23.75 25.25 25..00 2S,.50 29..50 31..25 21.00 23.25 25.03 26.75 26..50 29..75 29..75 31..25 34..25 8 20.88 21.00 10 24.31 24.34 u 26.42 26.29 14 30.66 30.71 15 33.67 33.81 16 35.11 35.15 16 38.56 38.60 22.25 22.50 24.75 26.50 23.25 27..75 31.,25 31..25 32..75 35..25 37..25 20 41.99 42.03 25.70 26.10 26.60 29.00 30.50 32..50 33..90 34..20 35,.10 36..60 37..80 38.,10 21 43.58 43.72 25.25 25.50 27.50 29.50 31.00 30,.75 34..00 34..00 35,.50 37,.50 39..75 39..00 41.75 24 46.71 47.41 24.40 26.34 30.78 34.08 35.24 38.69 42.13 44.05 47.51 _ _...... 38.49 41.40 44.36 47.81 2400 hr" f .25" llCCVY' F,x. Heavy 6000/7000 8 17.06 17.06 10 19.42 19.42 12 20.73 20.73 14 24.07 24.07 15 26.20 26.20 16 28.63 28.63 18 30.15 30.15 20 32.69 32.69 21 33.40 33.40 24 36.31 36.31 ... 19.36 20.76 24.04 26.20 27.60 30.05 32.63 33.40 36.25 -- -- ... ----- --- 30.05 32.65 33.40 36.25 If* ' + .25" 2400 Heavy Ex. Heavy 8 7.85 10 8.30 12 7.52 14 6.76 15 9.64 16 10.22 18 10.59 20 11.10 21 10.66 24 10.51 7.73 6.18 7.40 8.61 9.64 10.10 10.35 10.84 10.46 10.22 7.77 6.99 8.15 9.26 9.64 9.87 10.31 10.00 $.64 6000/7000 -- -- -- -- -- 9.42 9.88 $.55 $.22 PREPARED BY: ^3^ APPROVED BY: 02-10-002 3 { P92 7 ) 12/76 CONFIDENTIAL DOCUMENT R aD MFG. SALES / M j.e a I.E. Ofc HOI m BE distributed to UNA UTHORIZ ED PERSONNEL OTHERS CCTTDD0O1I5W24*3^ Haiti Pipe Size. Inches 8x6 10 x 10 12 x 12 14 x 14 IS x IS 16 x 16 IB x 18 20 x 20 21 x 21 24 x 24 Non. I.D.t" All Classes 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 2400 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 Hcaw 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.88 22.94 26.12 B.O.D.l" Min. ixtra H^avy ... 11.58 13.70 15.64 16.94 17.98 20.20 22.32 23.40 26.60 6o:c/?o:-o ... _-- ... __ ... ... 20.63 22.77 23.85 27.03 Brench Pipe Size. Inches 4 S 6 8 10 12 14 15 16 16 20 21 24 Non. T.D.i" All Classes 4.00 5.00 6.CO 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 ` 2400 4.87 5.98 7.04 9.06 11.14 17.24 15.32 16.36 17.42 19.CO 21.66 22.74 25.88 Heavy 4.87 5.98 7.04 9.24 11.30 13.46 15.50 16.56 17.60 19.30 21.88 22.94 26.12 B.O.D.?" Min. Extra H"av/ ... -- __ __ 11.58 13.70 15.64 16.94 17.93 20.20 22.32 23.40 26.60 6300/7020 ... -- ... ... ... ... ... ... ... 20.03 22.77 23. S3 27.03 L" 40,00" >3.00" 2400. Heavy. Extra Heavy and 6000/7000 KaIo Upc Site. 1Inches 8x8 10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 16 x 1C 20 x 20 21 x 21 24 x 24 _4 -1 Branch Sire. Inches _8 15 J2. U* 11 U. 70 21 24 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 78 c. i 1 1'or \iln mi i.i brunch Ing dimensionsi, refer to stemlard pipe ends. bofoJc'.M^nt!" 'l,OUn ">"vc 15 t0 be prrbcllcJ (with ccrt.-.poc.r) Brandi Sire. In. 2400 4 4.69 5 6.00 6 7.06 8 9.03 10 11.16 12 n.26 14 15.34 15 16.30 16 17.44 16 19. C2 20 21.68 n 22.76 Heavy 4.89 6.00 7.06 9.03 * 11.32 13.48 15.52 16.56 17.62 19.82 21.90 23.05 E>:. Heavy __ --- -- 11.60 13.72 15.66 16.96 13.00 20.72 22.34 23.68 6000/7^00 . . _ 20.72 * 22.3-* * 23.68 * brnch tnl oy h*vc t0 bo wv-,dtincd to (It. CTD015244 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertairileedEI A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO. : CertainTeed Corporation Pipe and Plastics Group description: 2 SUPERSEDES: March 8, 1979 564 33 DATE OF ISSUE: JUL 1 7 1979 Outside Purchased A/C Sewer Fittings KsIq Sire, Inches 4 8x8 10 x 10 12 x n 14 r. 14 15 * 15 16 x 16 is x ie 10 X 20 21.x 21 24 x 24 9.9 10.2 10.2 10.5 11.4 10.5 11.2 n.2 12.0 11.3 Lp" + .00" -.25" AU Classes Branch Sire, lncl.cs 5 6 6 10 n U 15 16 15 70 71 24 9.9 10.2 10.2 10.5 12.1 10.5 11.2 11.2 12.6 11.3 9.9 10.2 10.2 10.5 12.7 10.5 11.2 11.2 13.3 11.3 11.4 11.7 13.1 14.5 14.1 16.4 IC.2 19.6 14.7 21.3 13.2 13.1 14.5 15.4 16.4 18.2 19.6 15.9 21.3 14.6 14.5 16.7 16.4 18.2 19.6 17.2 21.3 16.0 17.9 16.4 16.2 19.6 18.5 21.3 18.6 16.4 IS.2 19.6 19.1 21.3 17.4 18.2 19.6 19.7 21.3 19.2 19.6 21.1 21-3 21.1 22.3 23.0 21.3 21.3 23.8 Lr" 4.OCT -1.C7 All Classes 4 9.75 5 9.75 6 9.75 8 11.75 10 12.50 12 14.75 14 16.75 15 19.75 16 18.75 18 20.25 20 21.00 21 24.50 tUla Size, Inches 8X8 10 X 10 12 X 12 14 X 14 15 X 15 16 X 16 18 X 16 20 X 20 21 X 21 24 X 24 L 12.5 13.5 14.0 15.0 16.2 15.5 17.0 17.5 18.6 19.0 !*1 - AU Classes Branch Sir e. Tnchrc 5 6 8 10 12 14 15 16 18 20 21 24 12.5 13.5 14.0 15.0 16.9 15.5 17.0 17.5 19.3 19.0 12.5 13.5 14.0 15.0 17.5 15.5 17.0 17.5 19.9 19.0 14.0 15.0 17.0 19.0 18.9 21.5 24.0 26.0 21.3 29.0 16.5 17.0 19.0 20.1 21.5 24.0 26.0 22.6 29.0 18.5 19.0 21.4 21.5 24.0 26.0 23.9 29.0 20.5 27.7 21.5 24.0 26.0 25.1 29.0 23.3 21.5 24.0 20.0 25.8 29.0 22.5 24.0 26.0 26.4 29.0 25.5 26.0 27.7 29.0 27.5 29.0 29.6 29.0 29.0 31.0 ld" + .00" -.06" 2400 Heavy Ex. Heavy 6000/7000 6 6.15 6.07 10 6.85 6.71 12 7.03 6.64 14 7.23 7.08 15 9.15 9.04 16 7.41 7.26 IS 8.53 8.35 20 8.74 8.55 21 9.R7 9.76 24 8.59 6.38 6.47 6.64 6.78 8.82 6.93 8.01 8.17 9.49 7.96 7.79 7.95 9.23 8.19 r* - All Classes 1 5 6 8 10 1? 14 15 ,, 10 . 20 21 24 13 00 14 00 15 25 16 50 17 30 17 50 18 75 20 00 20 .70 22 75 12. 75 12.75 14.00 13. 75 13.50 14.75 15. 00 14.75 IS.00 16. 00 13.75 17.25 17. 70 IS.70 19.80 17. 25 17.00 18.25 IS. 50 18.00 19.50 19. 50 19.75 20.<0 21. 10 21.60 23.70 22. 00 21.50 23.00 16 25 16 25 18.25 17 25 19.00 20 70 22.10 1? 50 20.00 19 60 21.75 20 75 22.25 2.-. 10 25.50 23 00 24.75 20.25 23.30 21.50 72.50 23.75 26.70 26.00 23. 30 22. 00 22. 00 2- . 25 27. 10 26. 50 23 25 24 00 lri 25 27 60 27 50 25.25 26.00 28.90 28.50 27 50 29 30 29.60 23 50 27.50 31.00 8 10 12 14 15 16 18 20 21 24 Lr" +.00" -.06" 2400 Heavy Ex. Heavv 15.63 19.72 22.32 24.92 28.05 27.53 31.16 33.75 36.13 38.47 16. 73 19 .76 22 .39 24 .97 28 .16 27 .58 31 24 33 .82 36 .24 3S 54 19 84 22 45 25 07 23 38 27 69 31 35 33 94 36 51 38. 68 6000/700C ___ 31 61 34 25 36 77 39 41 ripe Site. In. s 10 12 14 15 18 20 21 24 k:" t .25" 7400 Hoaw n.34 13. (V* 14.43 15.83 18.40 18.72 19.39 21.25 23.00 23.33 11.30 13.00 14.40 15.89 18.60 1R. 19 19.55 21.19 23.00 23.46 Extra Heavy - -12 .91 14 .30 15 .69 18 .60 18 .09 19 21 .06 23 .00 23 .32 6000/ 7000 -- -- -- -- 19.42 21.06 23.00 23.32 Pipe Site. In. 8 10 12 14 15 16 18 20 21 24 If" t .25" 2400 6.00 6.(0 6.73 6.98 9.15 8.17 8.28 8.74 9.(7 (.39 Hcaw 5.92 6.52 6.73 6.88 9.04 8.08 8.10 8.55 9.76 8.38 Heavy 6.22 6.40 6.55 8.62 7.75 7.76 >. 9.49 7.97 6000/ 7000 __ _ __ 7.51 7 91 9.23 7.71 . PREPARED BY: /^T 10-0023 IpWT) APPROVED by: 8.0 MFG. SALES I.E. j.e a. cmg i^/76 CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL OTHERS CTD015245 Kaln Pipe Site. Inches 8x8 10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 18 x 18 20 x 20 21 x 21 24 x 24 Horn. I.D.i" All Classes 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 2400 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 Heavy 9.24 11.30 13.46 15.50 16.56 17.60 19.80 21.88 22.94 26.12 B.O.D.t" Kin. Extra Heavy ... 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 6000/7000 .................. 20.63 22.77 23.85 27.03 Brunch Pipe Sire. Inches 4 5 6 8 10 12 14 15 16 18 20 21 24 Nom. 1 .D. V All Classes 4.00 5.00 6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 ' 2400 4.87 5.98 7.04 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 Heavy 4.67 5.98 7.04 9.24 11.30 13.46 15.50 16.56 17.60 '19.80 21.6S 22.94 26.12 B.O.n.-)" Min. Extra Heavy 6000/7000 _...._.. 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 ........................ 20.63 22.7 ? 23.85 27.03 V 40,00" -3,00*' 7**00, Heavy. Extra Heavy and 6000/7000 Branch Size. Inches Sire., Indies _4 _5 _6 -2 JO 11 J4 J5 J6 21 20 21 24 8X8 10 X 10 12 X 12 u X 14 15 X 15 16 X 16 18 X 18 20 X 20 21 X 21 36 X 24 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 39 39 39 39 39 39 52 52 52 52 52 52 78 Hot.i l. Tor Min and branch machining dimension#, refer to standard pipe enda. 1. Kirht end of main shown above la to bo prebcHrd (with ccrta-spacer) before shipment. Branch Site. In. 2400 4 4.89 5 6.00 6 7.06 8 9.08 10 11.16 17. 13.36 14 15.34 15 16.38 1C 17.44 18 19.63 30 21.68 21 32.76 C* +,04" .or* Heavy 4.89 6.00 7.06 9.08 t 11.32 13.48 15.52 16.58 17.62 19.82 21.90 23.05 Ex. Heavy -- 11.60 13.72 15.86 16.96 18.00 20.72 22.34 23.68 6000/7000 ... 20.22 * 22.34 * 23.68 * Branch end nnv have Co be unditnnd to fit- CTD015246 TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T-C.O. REF. NO. 2 SPECIFICATION NO: 564 PAGE NO.: 35 SUPERSEDES: March 8, 1979 DATE OF ISSUE: JUL 1 7 1979 description: Outside Purchased A/C Sewer Fittings Pipe Size, Inches 8x8 10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 18 x 18 20 x 20 21 x 21 24 x 24 tc +.000" -0.500" - All Classes 4 5 6 8 10 4.75 5.00 5.00 5.00 7.00 5.00 5.25 5.25 7.40 5.50 4.75 5.00 5.00 5.00 7.00 5.00 5.25 5.25 7.40 5.50 6.25 6.50 6.50 6.50 7.00 6.50 6.75 6.75 7.40 6.75 6.50 6.50 6.50 8.10 6.50 6.75 6.75 8.50 7.00 6.75 7.00 8.10 7.00 7.25 7.25 8.50 7.50 Branch Size., Inches 12 14 15 16 18 20 7.00 8.60 7.00 7.25 7.25 9.00 7.50 9.10 7.25 7.50 7.50 9.50 7.50 7.00 7.25 7.50 9.50 7.-50 7.50 7.50 9.50 7.50 8.25 10.00 8.25 10.00 8.25 21 8.25 Main Sire, Inches 4 5 '6 r' - All Classes Branch Size, Inches 8 10 12 14 15 16 18 20 21 24 8x8 10 x 10 12 X 12 14 x 14 15 x 15 16 x 16 18 x 18 20 x 20 21 X 21 24 x 24 8.75 10.00 11.00 12.00 14.50 13.00 14.25 15.25 17.90 17.50 8.75 10.00 11.00 12.00 14.50 13.00 14.25 15.25 17.90 17.50 10.25 11.50 12.50 13.50 14.50 14.50 15.75 16.75 17.90 18.75 10.25 11.50 12.50 13.50 15.60 14.50 15.75 16.75 19.00 19.00 ii .75 12 .75 14 .00 15 .60 15 .00 16 .25 17 .25 19 .00 19 .50 12.75 14.00 16.10 15.00 16.25 17.25 19.50 19.50 14.25 16.60 15.25 16.50 17.50 20.00 19.50 16.60 15.00 16.25 L7.50 >0.00 L9.50 15.25 16.50 17.50 20.00 19.50 17.25 18.25 20.50 20.25 18.25 20.50 20.25 20.50 20.25 20.25 La" + .25" - All Classes 8 X 8x4 10 xlO x 4 12 xl2 x 4 14 x!4 x 4 15 xl5 x 4 16 xI6 x 4 18 xl8 x 4 20 xl 0x4 20 x20 x 14 21 x?1 x 4 21 x2 l x 14 21 x.21 x 21 24 x24 x 4 24 x24 x 14 24 x2 4 x 24 through through through through through through through through through through through through through 8x8x8 10 xlO x 10 12 x!2 x 12 14 xl4 x 14 13 xlS x 15 10 xl6 x 16 13 x!3 X 18 20 x20 x 12 20 x20 x 20 21 x21 x 12 21 x21 x 20 24 x24 X 12 24 x24 x 21 11. 0 12. 5 13. 5 14. 5 16. 6 16. 5 18. 5 13. 0 19. 5 15. 5 19. 9 20. 5 13. 0 19. 3 21. 5 Pipe Size* In. 8 10 12 14 15 16 IS 20 21 24 1c" i ..25" 2400 Heavy 5.63 * 6.18 6.13 6.59 8.40 6.54 7.45 7.42 9.13 7.31 5.72 6.13 6.08 6.53 8.40 6.49 7.35 7.31 9.03 7.19 Extra Heavy mm -- 5.96 5.91 6.34 8.40 6.30 7.15 7.09 3.80 6.95 Ldm + .00" -.06" Pipe Site. In. 2400 Hew Extra llcaw 6000/ 7000 Pipe Sire. In. Le" < .00" -.06" 2400 Heavy Extra Heavy 8 10 12 14 15 16 18 20 21 24 *AREO by: (.47 (.93 6.88 (.6'. 8.47 7.79 8.70 8.(7 9.13 8.5( 6.38 (.85 6.27 6.75 8.32 - 7.70 8.60 8.56 9.03 8.44 6.71 6.65 6.58 8.13 7.51 8.40 8.34 8.80 8.20 APPROVED BY: _ _ _ _ 8 .19 8 .12 8 .58 7 .99 R aD 8 15.53 15.62 10 16.07 18.15 18.29 12 20.12 20.23 20.35 14 22.16 22.25 22.42 15 24.78 24.88 25.07 16 25.21 25.30 25.49 18 28.30 28.40 28.60 20 30.33 30.44 30.66 21 31.87 31.97 32.20 24 34.44 34.56 34.80 'yirv'ilii wf J4A 2 12/7602-10-0023 (P9 7) confidential DOCUMENT - NOT TO be distributed to unauthorized personnel 6000/ 7000 ... ___ 6.94 6.87 8.53 6.74 6000/ 7000 mmm -- -- --- __ -- 28.82 30.89 32.43 35.02 CTD015247 A/C Manhole Adaptors for PSM PVC Sewer Pipe 70*25-00 *------2.75-------- 1 f*W-J : v. . ' \\ Ln-TU ' S3 T B2 -------- r BI A X X" - .25 + 1/8" -1/16" Y" - .375 Typ. Z" *= .20 + 1/16" -1/8" Y Page 36 Marking: CERTAINTEED (SIZE) PSM PVC MANHOLE ADFT. Size In. 4 6 8 10 12 15 A" Bi" B2" B3" Type +.025" +.025" +.025" +.025" PSM 5.04 4.47 4.37 4.86 PSM 7.10 6.53 6.36 6.92 PSM 9.03 8.65 8.48 9.04 PSM 11.32 10.75 10.58 11.14 PSM 13.32 12.75 12.58 13.14 PSM 16.22 15.55 15.38 15.94 C" J" +.03" +.00" -.01" -.04' .92 . .92 .92 .92 .92 .92 .42 .42 .42 .42 .42 .42 Jl" R" V" -.02" F" +.032" +.03" ..00" Min. -.000" -.00" .18 .76 .18 .76 .18 .76 .18 .76 .18 .76 .18 .76 .093 .093 .093 .093 .093 .093 .80 .80 .80 .80 .80 .80 B.O.D.' +.25" -.00" 6.11 8.33 10.59 12.75 15.00 18.26 CTD015248 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertainTeed El A/C Standard Purchasing Specification SPECIFICATION NO: CertainTeed Corporation Pipe and Plastics Group 564 DESCRIPTION: Outside Purchased A/C Sewer Fittings Fittings Fitting markings are shown on the individual pages along with the fitting. 10.0 Special Information 1) Rings and Certa-spacers as required will be supplied to the vendor via CertainTeed's Ambler plant (only those fittings which are prebelled by the vendor or otherwise specified require rings and certa-spacers). 2) All fittings are to be shipped to the Ambler plant for inspection purposes. No fittings shall be shipped directly to a job without authorization from CertainTeed's Marketing and Quality Control Departments. 3) This specification and the information it contains is the property of CertainTeed. Under no circumstancesshall this specification or dimensional details herein be released to any unauthorized persons. CTD015249 PREPARED BY: APPROVED by: R AO MFG. a>tr m m t.E. OTHERS ('AS' 02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL Standard Pipe Pipe Size, Nora. Indies I.D." O.D.t" O.D.V' 4 4.00 4.62 4.78 5 5.00 5.66 5.82 6 6.00 6.66 6.82 8 8.00 8.80 8.96 10 10.00 10.89 11.05 12 12.00 12.99 13.15 14 14.00 15.07 15.23 15 15.00 16.11 16.27 16 16.00 17.15 17.31 18 18.00 19.23 19.48 20 20.00 21.29 21.54 21 21.00 22.37 22.53 24 24.00 25.51 25.76 ___________ B.O.D." Min. X" C" t" Class + .06" + .06" Min. 1500 Class 2400 Class 3300 Class 4000 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 2.09 2.09 2.09 2.44 2.81 2.81 3.19 3.19 3.19 3.81 3.81 3.81 3.81 .20 4.81 .22 5.91 .24 6.91 .27 9.00 .30 11.14 .33 13.24 .36 15.32 .39 16.36 .41 17.42 .44 .48 .52 .56 4.87 5.98 7.04 9.06 11.14 13.24 15.32 16.36 17.42 19.60 21.66 22.74 25.88 5.01 6.20 7.22 9.24 11.30 13.46 15.50 16.56 17.60 19.CO 21.88 22.94 26.12 11.45 13.54 15.64 16.72 17.74 20.00 2? T1Q 23.1R 26.36 Class 5000 11.58 13.70 15.84 16.94 17.98 20.20 22.32 23.40 26.60 Class 6000 Class 7000 20.43 22.55 23.63 26.79 20.63 22.77 23.8, 27.03 Tolerance; O.D.i" and 0.D.2" 4" through 16" +.02" 18" through 24" +.03" Pipe Size, Inches 4,5 and 6 8 10 and 12 QC 2 14 16 16 14,15 & 16 18,20, 21 & 24 18 20 p"+.06" .50 .50 .62 .68 .75 { CCRTA - JPaCCR Band Certa-spacer bands are to be applied to pipe ends as shown above for t. e prebelled end of Wyes a Tees, and one end of each elbow. The band shouxd e against the O.D.2 shoulder. (Bands may be heated to ease placement.) CTD015250 TECHNICAL SPECIFICATIONS Old Design Page 9 A 14" and 16" Fluld-Tlte Sewer and 15" and 21" CG Sewer Couplings All Couplings except 15" and 21" B 15" and 21" Coupling Sizes only Dimensions Coupling Site, In. 14 15 16 21 A" 15.87 16.81 17.95 23.07 B" or Bj" * 15.19 16.43 17.27 22.69 H" b2" +.00" * -.06" 16.24 22.50 5.25 7.13 5.25 8.13 L" +.25" -.00" 7.00 8.90 7.00 9.90 C 1A S S 1500 17.15 18.26 19.31 Class 2400 17.15 18.26 19.31 24.96 B.O.D. Class 3300 +.25" -.00" Clas6 Class 4000 5000 17.15 18.26 19.31 24.96 17.48 18.61 19.68 25.26 17.48 18.61 19.68 25.26 Class 6000 25.81 Class 7000 25.81 *Tulerance: A and D A, B^and B, 14" and 16" +.025" 15" + .050" -.020" 21" + .040" Coupling Size, In. 14 and 16 15 and 21 F" Min. .75 .76 cn** +.04" -. 00" .62 1.11 +.03" -.00" .50 .42 R"+* :.ov .20 .06 **Tolcranco 15" and 21" C" - 1.03" J" - +.00" -.04" R" - Max. 0C + 20 18 V +.02" -.00" .18 B Hr 2O 45 CTD015252 TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertairileedlH A/C Standard Purchasing Specification SPECIFICATION NO: PAOC NO.: CertainTeed Corporation Pipe and Plastics Group 564 description: Outside Purchased A/C Sewer Fittings Standard Coupling 4b 2 h-F. ling , In. A" 4 5.24 5 6.28 6 7.28 8 9.55 10 11.64 12 13.74 14 16.07 15 17.11 16 18.15 18 20.48 20 22.54 21 23.62 24 26.70 B" 4.71 5.75 6.75 8.89 11.00 13.10 15.19 16.23 17.27 19.36 21.42 22.50 25.64 +.00" -.06" 3.50 3.50 3.50 4.00 4.75 4.75 5.51 5.51 5.51 6.50 6.50 6.50 6.50 Dimensions L" +.25" -.00" Class 1500 4.75 4.75 4.75 5.92 7.06 8.12 5.75 10.50 6.50 12.75 6.50 15.00 7.25 17.15 7.25 18.26 7.25 19.31 8.25 8.25 8.25 8.25 Class 2400 5.92 7.06 8.12 10.50 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 B.O.D." +.25" -.00" Class 3300 6.00 7.14 8.20 10.59 12.75 15.00 17.15 18.26 19.31 21.63 23.81 24.96 28.22 Class 4000 13.00 15.24 17.48 18.61 19.68 22.09 24.15 25.26 28.69 Class 5000 13.00 15.24 17.48 18.61 19.68 22.09 24.15 25.26 28.69 Class 6000 Class 7000 22.47 24.67 25.81 29.15 22.47 24.67 25.81 29.15 Tolerance: A and B - 4" through 16" +.025" 18" through 24" +.040" Coupling Size, In. 4". 5" 6 8", 10", 12", 14",15", 6 16" 18",20", 21" 6 24" F" Min, .50 .75 .75 .75 C + .04" .=*22^ .50 .62 .75 1.00 r +.03" -.00" .35 .50 .50 .63 R" + .01" .156 .20 .20 .25 0C . 13 18 16 12 CTD015253 PREPARED BY: 02-10-0023 (P927) APPROVED BY: >wV^> confidential document NOT TO MFO. SALES I.E. OTHERS J4 A m. UTEO TO UNAUTHORIZED PERSONNEL Page 10 SLEEVE ADAPTOR Dimensions Pipe Size, Inches 4 5 6 I.D.2" +.030" 5.45 6.50 7.50 B.O.D." Min. 6.42 7.50 8.67 Marking Example: CERTAINTEED 4"SEWER SLEEVE _____ ADPT. TECHNICAL SPECIFICATIONS CertairileedlSI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. 1 SPECIFICATION NO: 564 PAOE NO.: 37 supersedes: DATE OF ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings A/C Manhole Adaptors for 18" thru 27" PVC Sewer Pipe 7 BOD BA X" - .25 + 1/8" -1/16" Y" = .375 Typ. Z" .25 + 1/16" -1/8" Marking: CERTAINTEED (SIZE) PVC SEWER MANHOLE ADPT. Size, In. PVC + A" +vB" 3" G" J" B.O.D." +.04" +.03" F" R" CC +.25" Use Z.040" +.040" .040" 1.040" -.00" -.00" Min. +.01" +2o -.00" 18 PSM Sewer 19.95 18.83 19.33 19.83 1.00 21 PSM Sewer 23.31 22.19 22.69 23.19 1.00 24 PSM Sewer 26.08 24.96 25.46 25.96 1.00 27 PSM Sewer 29.25 28.13 28.63 29.13 1.00 .50 1.00 .25 .50 1.00 .25 .50 1.00 .25 .50 1.00 .25 12 21.80 12 25.40 12 28.30 12 31.70 CTD015255 FRPARKO BY: approved by: B 4O \ QftS 02-10-0023 P927 1^/76( ) CONFIDENTIAL DOCUMENT - NOT TO BE P^IBTTlUUlBBilr/TrEBDP TO uUNNAALUfTTMUOMa JlTrfnQ *r>AM OTHERB Page 38 This page left intentionally blank CTD015256 TECHNICAL SPECIFICATIONS CertainTeedGI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: 1 SUPERSEDES: 564 Addendum 1 DATE OF ISSUE: MAR 8 1979 DESCRIPTION: Outside Purchased A/C Sewer Fittings NOT TO BE DISTRIBUTED TO VENDORS 1.0 General This addendum is designed to show the sampling plan to be used for incoming inspection of fittings and other information that is considered to be pertinent. 2.0 Sampling A lot is defined as the quantity of all fittings shipped on one order, received at one time and identified by a Purchase Order Number. A sub-lot shall be defined as the number of fittings of a given type and size within the lot. A lot may contain one or many sub-lots. 2.1 In a shipment where the sample size exceeds the number of specimens in the sub-lot, then that sub-lot shall be sampled on the next order. 2.2 Where possible each specimen of a sub-lot shall be taken from a separate container.Where there are a considerable number in the container, more than one may be taken. 2.3 On sampling, if any individual sub-lot exceeds the reject number of the plan, that sub-lot shall be rejected. All other sub-lots may be accepted provided they are found to be within the sample plan. For example, if on a shipment there are tees, wyes, end caps and increasers, and the sample consists of specimens of the tees, wyes, and end caps and if the tees have a reject number exceeding the plan, the tees shall be rejected, the wyes, end caps and reducer shall be accepted. On the next shipment, the increasers .must be sampled. 2.4 If any vendor has three (3) consecutive rejections (lots or sub-lots) they shall be placed on tightened inspection, and Valley Forge, A/C Q.C. Manager notified. CTD015257 PREPARED BY: jLdOj 02-10-0023 (P927) APPROVED BY: R *D MFO. 12/76 CONFIDENTIAL DOCUMENT - NOT TO < IsdL SALES I.E. OTHERS Gtfte PERSONNEL TECHNICAL SPECIFICATIONS CertainTeed H CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAOE NO.: 1 564 Addendum 2 supersedes: DATE OF ISSUE: MAR 8 1979 description: Outside Purchased A/C Sewer Fittings NOT TO BE DISTRIBUTED TO VENDORS 2.5 All dimensions and workmanship shall be checked, however, some requirements are more critical than others. If a defect is found in any of the critical requirements, the sub-lot shall be rejected regardless of the reject number. 2.5.1 Critical Requirements a) Any reject in the sealing area, i.e. cracks, dimensions, etc. 3.0 Sampling Plan 3.1 Normal Inspection Sampling for normal inspection procedure shall be carried out according to the sampling plan in Table 1 which represents a 97.5 percent quality level. No. of Fittings In Sub-lot Table 1 Sample Size Acceptable Defectives Defectives Constituting Rejection 0 - 150 151 - 1200 1201 - 3200 3201 - 10,000 3 8 13 20 0 0 0 1 1 1 1 2 3.2 Tightened Inspection Table 2 No. of Fittings Sample Acceptable in Sub-lot Size Defectives 0 - 150 151 - 1200 1200 - 3200 3201 - 10,000 8 13 20 32 0 0 0 1 Defectives Constituting Rejection 1 1 1 2 CTD015258 PREPAREO BY: 4*0/ approved by: v~^ R ft D < MFO. SALES I.E. 00 tributed to unauthorized personnel OTHER* TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CertairifeedH CertainTeed Corporation Pipe and Plastics Group A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: 1 564 Addendum 3 supersedes: DATE DF issue: MAR 8 1979 description: Outside Purchased A/C Sewer Fittings NOT TO BE DISTRIBUTED TO VENDORS 4.0 Rejection The following procedure shall be followed on all rejected shipments: 4.1 The Headquarters Purchasing Department shall be notified. They will issue instructions on when and how the shipment is to be returned. 4.2 Quality Control Headquarters (A/C) shall be notified. If requested, defective.samples shall be forwarded to the Quality Control Manager. 5.0 Approved Vendors JNC Limited Ontario, Toronto, Canada Special Note to the Ambler Plant - JNC fabricates fittings from pipe pur chased from Canadian JM. They will be shipped to Ambler on pallets with shrink wrap covering. When placing an order with JNC the plant should determine the rings*, certa-spacers , and A/C discs required and ship them to JNC. Fittings may be stored and shipped as packaged by JNC. Those packages opened for sampling purposes shall be repackaged by Ambler. *JNC needs rings for only those fittings which are prebelled. CTD015259 PREPARED BY: d>M/ 2-10-0023 (P927) APPROVED by: R *D Qfe 12/76 confidential DOCUMENT - not to be distributed to unauthorized personnel OTHERS TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. 3 SPECIFICATION NO: #564 Addendum PAGE NO.: 4 SUPERSEDES: DATE OF ISSUE: JUL 1 7 1979 DCICRimON: Outside Purchased A/C Sewer Fittings NOT TO BE DISTRIBUTED TO VENDORS 6.0 Waiver on 6" B.O.D.? Dimension Ref: Letter dated 3/23/79 from Mr. Marvin R. Streepy to Mr. John Clinton (JNC Limited). It has been agreed upon to accept the B.O.D.2 dimension of 6" Branches for Tees and Wyes at 7.00" minimum as an alternate to the 7.04" minimum specified in Purchasing Spec. #564. This action permits the use of a core cutter more suited to the 7.00" dimension. All other properties and dimension shall remain in effect. NOTE: Waiver is only temporary. PREPAREO BY: APPROVED BY: R *O MFO. BALES I.C fat Jt.A 02-10-0023 {P927) 12/76 CONFIDENTIAL. OOCUMCNT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL