Document 2KV2Lj48EgKOG10OGE74kp2N

V-3 NON-PACKAGED ALL PURPOSE BOILER-BURNER UNITS Factory Crated and Assembled Oil Fired Steam or Water --Series 1B-J1 Complete Oil Boiler consists of the following: Section Sixes V-3 V-3 V-3 V-3 116/128 172/186 228/244 284/302 Section Assemblage--covered with half crate (see details next page)..... . 1 1 1 1 Canopy with insulation and cleanout cover plate instaDed on section assemblage....... ................. ..................._ __ ... 1111 Burner Plate---installed on section assemblage......... - -- ... -- 1 11 Built-in Tanldess Water Heater-- factory installed in Section assemblage when ordered........ .... .............. 222 226 232 445 Trim & Miscellaneous Box--see details next page according to Boiler Type 1 1 1 1 Jacket--Complete with oil burner pressure ring assembly________ ______ 1 1 1 1 ADDITIONAL BOXES REQUIRED FOR V-3 BOILER/BURNER UNITS Box OQ Burner Primary Control Control Set Regulator Contents 1--DH-F Arcoflame Ofl Burner l--Flame Detector w/Leads Installed 1--Light Sensing Relay... (if combina tion control not furnished) Controls (as required) 2--Burner Nordes (as required) I--Wiring Diagram 1--Draft Regulator (as required) ADDITIONAL BOXSHIPPED ON SPECIAL ORDER ONLY Box Contents Jacket Extension | 1--Jacket Extension Complete 26A PLAINTIFF'S EXHIBIT A5r- JLC*V 00116 V-3 NON-PACKAGED OIL-FIRED BOILER-BURNER UNITS SECTION ASSEMBLAGE Factory assembled with following sections as required Section F Front C Center B Back V-3 116/128 1 1 1 V-3 172/186 1 2 1 V-3 228/244 1 3 V-3 284/302 1 4 1 WATER TRIM & MISC. BOX Different for each size Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets H'xl* Hex Head Cap Screws Pressure & Temperature Gauge Va " Relief Valve Vi" Square Head Pipe Plug 1 Vi * Countersunk Pipe Plug Va" Drain Valve 1 lb. Can Boiler Putty Installation Manual Name & Rating Plate Water Unit Less Heater With Heatei 11 10 21 12 6 11 11 22 11 11 11 11 1 STEAM TRIM & MISC. BOX Different for each size Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets x 1* Hex Head Cap Screws Steam Gauge Water Column Trim Va " Pipe Siphon Va " x Va ' Hex Bushing Va " Pop Safety Valve 1 Vt" Countersunk Pipe Plug Va " Drain Valve 1 lb. Can BoBer Putty Installation Manual Name & Rating Plate Special Order Only: No. 67 Low Water Cut-off including: Vim Brass Close Nipple Vi" Brass Ground Joint Union Vi" \2Vi" Brass Pipe Nipple Vi" x 4Vi" Brass Pipe Nipple Steam Unit Less Heater With Heatei 11 10 21 12 6 11 11 11 11 11 11 11 11 11 11 11 i1 i1 11 1 26B 00117 V-3M NON-PACKAGED ALL PURPOSE OIL BOILER Factory Crated and Assembled 03 Fired Steam or Water -- Series 1B-J1 Complete Oil Boiler consists of the following: Section Sizes V-3M V-3M V-3M V-3M 92/110 138/156 184/202 230/248 Section Assemblage--covered with half crate {see details next page)-------- 1 1 1 1 Factory installed combustion chamber__________ ___ __________________ 1 1 1 Canopy w/lnsulation and cleanout cover plate Installed on section assemblage ................. ......... ....... .. ...... ...... 1 111 Burner Plate--installed on section assemblage---------- ---------- ---------------- 1 11 BuflMn Tankless Water Heater-- factory installed in section assemblage when ordered .............................. 222 226 232 445 Trim & Mfec. Box--see details next page according to Boiler Type............ 1 11 Jacket--Complete w/oil burner pressure ring assembly ........_................. 1 1 1 1 ADDITIONAL BOXSHIPPED ON SPECIAL ORDER ONLY Box Contents Jacket Extension 1--Jacket Extension Complete 26C 00118 I ! V-3M NON-PACKAGED OIL-FIRED BOILER SECTION ASSEMBLAGE Factory assembled with following sections as required Section F Front C Center B Back V-3M 92/110 I 1 1 V-3M 138/156 1 2 1 V-3M 184/202 1 3 1 V-3M 230/248 1 4 1 WATER TRIM & MISC. BOX Different for each (he Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets 44 " x 1" Hex Head Cap Screws Pressure & Temperature Gauge 44 " Relief Valve Vi * Square Head Pipe Plug 1V4* Countersunk Pipe Plug H ' Drain Valve 1 lb. Can Boiler Putty Installation Manual Name St Rating Plate Water Unit Less Heater With Heater 1 10 21 12 6 11 11 22 11 11 11 11 11 STEAM TRIM & MISC. BOX Different for each size Water Heater Opening Cover Plate Blank Cover Plate Cover Hate Gaskets H'xl' Hex Head Cap Screws Steam Gauge Water Column Trim V* " Pipe Siphon 44 * x V* " Hex Bushing 44 " Pop Safety Valve V/i" Countersunk Pipe Plug 44 ' Drain Valve 1 lb. Can Boiler Putty Installation Manual Name & Rating Plate Special Order Only: No. 67 Low Water Cut-off including: Vi" Brass Close Nipple V2' Brass Ground Joint Union '/2 ' xl':" Brass Pipe Nipple 1'- ^ J12 Brass Pipe Nipple Steam Unit Less Heater With Heater 11 10 21 12 6 11 11 11 11 11 11 1 11 11 11 11 1 1 11 1 26D 00119