Document 2KV2Lj48EgKOG10OGE74kp2N
V-3 NON-PACKAGED ALL PURPOSE
BOILER-BURNER UNITS
Factory Crated and Assembled
Oil Fired
Steam or Water --Series 1B-J1
Complete Oil Boiler consists of the following:
Section Sixes
V-3 V-3 V-3 V-3 116/128 172/186 228/244 284/302
Section Assemblage--covered with half crate (see details next page)..... .
1
1
1
1
Canopy with insulation and cleanout cover plate instaDed on section assemblage....... ................. ..................._ __ ...
1111
Burner Plate---installed on section assemblage......... - -- ... --
1
11
Built-in Tanldess Water Heater-- factory installed in Section assemblage when ordered........ .... .............. 222 226 232 445
Trim & Miscellaneous Box--see details next page according to Boiler Type
1
1
1
1
Jacket--Complete with oil burner pressure ring assembly________ ______
1
1
1
1
ADDITIONAL BOXES REQUIRED FOR V-3 BOILER/BURNER UNITS
Box OQ Burner Primary Control Control Set
Regulator
Contents
1--DH-F Arcoflame Ofl Burner l--Flame Detector w/Leads Installed
1--Light Sensing Relay... (if combina tion control not furnished)
Controls (as required) 2--Burner Nordes (as required) I--Wiring Diagram
1--Draft Regulator (as required)
ADDITIONAL BOXSHIPPED ON SPECIAL ORDER ONLY Box Contents Jacket Extension | 1--Jacket Extension Complete
26A
PLAINTIFF'S EXHIBIT
A5r- JLC*V
00116
V-3 NON-PACKAGED OIL-FIRED
BOILER-BURNER UNITS
SECTION ASSEMBLAGE Factory assembled with following sections as required
Section
F Front C Center B Back
V-3 116/128
1 1 1
V-3 172/186
1 2 1
V-3 228/244
1 3
V-3 284/302
1 4 1
WATER TRIM & MISC. BOX Different for each size
Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets H'xl* Hex Head Cap Screws Pressure & Temperature Gauge Va " Relief Valve Vi" Square Head Pipe Plug 1 Vi * Countersunk Pipe Plug Va" Drain Valve 1 lb. Can Boiler Putty Installation Manual Name & Rating Plate
Water Unit
Less Heater With Heatei
11 10 21 12 6 11 11 22 11 11 11 11
1
STEAM TRIM & MISC. BOX Different for each size
Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets
x 1* Hex Head Cap Screws Steam Gauge Water Column Trim Va " Pipe Siphon Va " x Va ' Hex Bushing Va " Pop Safety Valve 1 Vt" Countersunk Pipe Plug Va " Drain Valve 1 lb. Can BoBer Putty Installation Manual Name & Rating Plate
Special Order Only:
No. 67 Low Water Cut-off including: Vim Brass Close Nipple Vi" Brass Ground Joint Union Vi" \2Vi" Brass Pipe Nipple Vi" x 4Vi" Brass Pipe Nipple
Steam Unit
Less Heater With Heatei
11 10 21 12 6 11 11 11 11 11 11 11 11 11 11
11
i1 i1 11
1
26B
00117
V-3M NON-PACKAGED ALL PURPOSE OIL BOILER
Factory Crated and Assembled
03 Fired
Steam or Water -- Series 1B-J1
Complete Oil Boiler consists of the following:
Section Sizes
V-3M V-3M V-3M V-3M 92/110 138/156 184/202 230/248
Section Assemblage--covered with half crate {see details next page)--------
1
1
1
1
Factory installed combustion chamber__________ ___ __________________
1
1
1
Canopy w/lnsulation and cleanout cover plate Installed on section assemblage ................. ......... ....... .. ...... ......
1 111
Burner Plate--installed on section assemblage---------- ---------- ----------------
1
11
BuflMn Tankless Water Heater-- factory installed in section assemblage when ordered .............................. 222 226 232 445
Trim & Mfec. Box--see details next page according to Boiler Type............
1
11
Jacket--Complete w/oil burner pressure ring assembly ........_.................
1
1
1
1
ADDITIONAL BOXSHIPPED ON SPECIAL ORDER ONLY
Box Contents
Jacket Extension
1--Jacket Extension Complete
26C 00118
I !
V-3M NON-PACKAGED OIL-FIRED BOILER
SECTION ASSEMBLAGE Factory assembled with following sections as required
Section
F Front C Center B Back
V-3M 92/110
I 1 1
V-3M 138/156
1 2 1
V-3M 184/202
1 3 1
V-3M 230/248
1 4 1
WATER TRIM & MISC. BOX Different for each (he
Water Heater Opening Cover Plate Blank Cover Plate Cover Plate Gaskets 44 " x 1" Hex Head Cap Screws Pressure & Temperature Gauge 44 " Relief Valve Vi * Square Head Pipe Plug 1V4* Countersunk Pipe Plug H ' Drain Valve 1 lb. Can Boiler Putty Installation Manual Name St Rating Plate
Water Unit
Less Heater With Heater
1 10 21 12 6 11 11 22 11 11 11 11 11
STEAM TRIM & MISC. BOX Different for each size
Water Heater Opening Cover Plate Blank Cover Plate Cover Hate Gaskets H'xl' Hex Head Cap Screws Steam Gauge Water Column Trim V* " Pipe Siphon 44 * x V* " Hex Bushing 44 " Pop Safety Valve V/i" Countersunk Pipe Plug 44 ' Drain Valve 1 lb. Can Boiler Putty Installation Manual Name & Rating Plate
Special Order Only:
No. 67 Low Water Cut-off including: Vi" Brass Close Nipple V2' Brass Ground Joint Union '/2 ' xl':" Brass Pipe Nipple 1'- ^ J12 Brass Pipe Nipple
Steam Unit
Less Heater With Heater
11 10 21 12 6 11 11 11 11 11 11
1 11 11 11
11
1 1 11 1
26D
00119